Oil Analysis File (OAN)
Oil Analysis File (OAN)
(OAN)
~ FILE VERIFICATION
# (Information in this section is Assigned by the AER, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM [CHAR 13] AER WTC Tracking ID Will not be Blank, system will input AER-WTC Unique Certification number:
WTCDAT [YYYY MM DD HHHH] Submission/Acceptance Date Will not be Blank, system will input Date of WTC Verification & Acceptance
WTCSUB [CHAR 60] Submitter Will not be Blank, system will input Company whom Submitted Specific Well Test Data
COMP. [CHAR 60] Licensee Name Will not be Blank, system will input Based on Licensee
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
PASTYPE. [CHAR 7] DIGITAL DATA - OIL ANALYSIS PAS-OAN Oil Analysis test, format
UNIT. [CHAR 1] UNITS FLAG (M)etric Metric Units for AER submission
VERS. [NUMB 5,2] AER DIGITAL WELL TEST DATA 4.00 Current AER version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
FORM. [CHAR 20] FORMATION NAME Name of the geological formation/zone
WSFL. [NUMB 2] WELL FLUID TYPE AT TEST DATE Mandatory, must have a valid AER fluid code = Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
(01) Oil, (02) Gas, (06) Water, or (17) Crude
Bitumen
SDAT.DAY [YYYY MM DD] DATE SAMPLED Must be >= Spud Date and <= Abandoned Date Date sample gathered
and <= Submission Date
IDENT. [CHAR 12] CONTAINER IDENTITY Identification code of container
SPNT. [NUMB 2] SAMPLE POINT CODE Mandatory, must be Valid AER Sample Point Code Sample gathering point
(See Footnote).
SPNTN. [CHAR 100] SAMPLE POINT NAME Laboratories Unique Text Description of Sample Gathering Point
ADAT.DAY [YYYY MM DD] DATE ANALYZED Must be >= [SDAT] (Sample Date) and <= Date Sample Analysis
Submission Date
SPRES.KPAA [NUMB 8,2] SAMPLE PRESSURE Optional, can not be zero Pressure as Sampled (in field) - kPaa
STEMP.DEGC [NUMB 5,2] SAMPLE TEMPERATURE Optional, can be zero Temperature as Sampled (in field) - DegC
RPRES.KPAA [NUMB 8,2] RECEIVED PRESSURE Optional, can not be zero Pressure as Received (in Lab) -kPaa
RTEMP.DEGC [NUMB 5,2] RECEIVED TEMPERATURE Optional, can be zero Temperature as Received (in Lab) - DegC
DSTLOC. [CHAR 1] DST SAMPLE LOCATION If [SPNT] (Sample Point Code) = (50) then
[DSTLOC] (DST Sample Location) must be (T)op,
(M)iddle, or (B)ottom. Else must be Null.
OANC. [CHAR 240] COMMENT ON SAMPLE Optional General Free form Comment (regarding Sample or Analytical
Procedures).
API. [NUMB 6,2] API GRAVITY @ 15 DEGC Optional, can be null or zero API gravity @ 15 (Degrees Celsius)
TSUL.FRAC [NUMB 7,5] TOTAL SULPHUR MASS FRACTION If [TSUL.GM/KG] (Total Sulphur) is Null then Mass fraction of total sulphur
[TSUL.FRAC] (Total Sulphur Mass Fraction) is
mandatory (either must be present). Can be zero.
TSUL.GM/KG [NUMB 7,2] TOTAL SULPHUR If TSUL.FRAC is null then [TSUL.FRAC] (Total Ratio of total sulphur, gm/kg
Sulphur Mass Fraction) is mandatory (either must
be present). Can be zero
TSALT.KG/M3 [NUMB 7,5] TOTAL SALT Optional, can be null or zero Salt kg/m3
RVP.KPAA [NUMB 8,2] REID VAPOUR PRESSURE Optional, can be null or zero Reid Vapour Pressure, kPaa
CONRD.FRAC [NUMB 8,2] CARBON RISIDUE CONRADSON Optional, can be null or zero Carbon Risidue, mass fraction - Conradson
FRACTION
RAMBT.FRAC [NUMB 8,2] CARBON RISIDUE RAMSBOTTOM Optional, can be null or zero Carbon Risidue, mass fraction - Ramsbottom
FRACTION
PPTUSBM.DEGC [NUMB 5,2] POUR POINT U.S.B.M. STANDARD DEGC Optional, can be null, negative or zero Pour Point U.S.B.M. standard - (Degrees Celsius)
PPTASTM.DEGC [NUMB 5,2] POUR POINT A.S.T.M. STANDARD DEGC Optional, can be null, negative or zero Pour Point A.S.T.M. standard - (Degrees Celsius)
DVL1.FRAC [NUMB 4,2] VOLUME FRACTION POINT 1 Optional, must be reported if established Distillation volume fraction 1
DTP1.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 1 Optional, must be reported if established Distillation volume temperature 1, (Degrees Celsius)
DVL2.FRAC [NUMB 4,2] VOLUME FRACTION POINT 2 Optional, must be reported if established Distillation volume fraction 2
DTP2.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 2 Optional, must be reported if established Distillation volume temperature 2, (Degrees Celsius)
DVL3.FRAC [NUMB 4,2] VOLUME FRACTION POINT 3 Optional, must be reported if established Distillation volume fraction 3
DTP3.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 3 Optional, must be reported if established Distillation volume temperature 3, (Degrees Celsius)
DVL4.FRAC [NUMB 4,2] VOLUME FRACTION POINT 4 Optional, must be reported if established Distillation volume fraction 4
DTP4.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 4 Optional, must be reported if established Distillation volume temperature 4, (Degrees Celsius)
DVL5.FRAC [NUMB 4,2] VOLUME FRACTION POINT 5 Optional, must be reported if established Distillation volume fraction 5
DTP5.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 5 Optional, must be reported if established Distillation volume temperature 5, (Degrees Celsius)
DVL6.FRAC [NUMB 4,2] VOLUME FRACTION POINT 6 Optional, must be reported if established Distillation volume fraction 6
DTP6.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 6 Optional, must be reported if established Distillation volume temperature 6, (Degrees Celsius)
DVL7.FRAC [NUMB 4,2] VOLUME FRACTION POINT 7 Optional, must be reported if established Distillation volume fraction 7
DTP7.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 7 Optional, must be reported if established Distillation volume temperature 7, (Degrees Celsius)
DVL8.FRAC [NUMB 4,2] VOLUME FRACTION POINT 8 Optional, must be reported if established Distillation volume fraction 8
DTP8.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 8 Optional, must be reported if established Distillation volume temperature 8, (Degrees Celsius)
DVL9.FRAC [NUMB 4,2] VOLUME FRACTION POINT 9 Optional, must be reported if established Distillation volume fraction 9
DTP9.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 9 Optional, must be reported if established Distillation volume temperature 9, (Degrees Celsius)
DVL10.FRAC [NUMB 4,2] VOLUME FRACTION POINT 10 Optional, must be reported if established Distillation volume fraction 10
DTP10.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 10 Optional, must be reported if established Distillation volume temperature 10, (Degrees Celsius)
DVL11.FRAC [NUMB 4,2] VOLUME FRACTION POINT 11 Optional, must be reported if established Distillation volume fraction 11
DTP11.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 11 Optional, must be reported if established Distillation volume temperature 11, (Degrees Celsius)
DVL12.FRAC [NUMB 4,2] VOLUME FRACTION POINT 12 Optional, must be reported if established Distillation volume fraction 12
DTP12.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 12 Optional, must be reported if established Distillation volume temperature 12, (Degrees Celsius)
DVL13.FRAC [NUMB 4,2] VOLUME FRACTION POINT 13 Optional, must be reported if established Distillation volume fraction 13
DTP13.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 13 Optional, must be reported if established Distillation volume temperature 13, (Degrees Celsius)
DVL14.FRAC [NUMB 4,2] VOLUME FRACTION POINT 14 Optional, must be reported if established Distillation volume fraction 14
DTP14.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 14 Optional, must be reported if established Distillation volume temperature 14, (Degrees Celsius)
DVL15.FRAC [NUMB 4,2] VOLUME FRACTION POINT 15 Optional, must be reported if established Distillation volume fraction 15
DTP15.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 15 Optional, must be reported if established Distillation volume temperature 15, (Degrees Celsius)
DVL16.FRAC [NUMB 4,2] VOLUME FRACTION POINT 16 Optional, must be reported if established Distillation volume fraction 16
DTP16.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 16 Optional, must be reported if established Distillation volume temperature 16, (Degrees Celsius)
DVL17.FRAC [NUMB 4,2] VOLUME FRACTION POINT 17 Optional, must be reported if established Distillation volume fraction 17
DTP17.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 17 Optional, must be reported if established Distillation volume temperature 17, (Degrees Celsius)
DVL18.FRAC [NUMB 4,2] VOLUME FRACTION POINT 18 Optional, must be reported if established Distillation volume fraction 18
DTP18.DEGC [NUMB 5,2] VOLUME TEMPERATURE POINT 18 Optional, must be reported if established Distillation volume temperature 18, (Degrees Celsius)
CRKBP.DEGC [NUMB 5,2] CRACKED BOILING POINT Optional, must be reported if established Cracked boiling point temperature, (Degrees Celsius)
TEMPERATURE
TROOM.DEGC [NUMB 5,2] ROOM TEMPERATURE Optional, can be null. If present, must be > 0 and < Lab room temperature, (Degrees Celsius)
45
DVLNP.FRAC [NUMB 4,2] NAPHTHA SUMMARY VOLUME FRACTION Optional, can be zero or null Naphtha fraction
DVLKR.FRAC [NUMB 4,2] KEROSENE SUMMARY VOLUME Optional, can be zero or null Kerosene fraction
FRACTION
DVLGO.FRAC [NUMB 4,2] LIGHT GAS/OIL SUMMARY VOLUME Optional, can be zero or null Light gas/oil fraction
FRACTION
DVLRC.FRAC [NUMB 4,2] RECOVERED SUMMARY VOLUME Optional, can be zero or null Recovered fraction
FRACTION
DVLRS.FRAC [NUMB 4,2] RESIDUE SUMMARY VOLUME FRACTION Optional, can be zero or null Residue fraction
DVLLS.FRAC [NUMB 4,2] LOSS SUMMARY VOLUME FRACTION Optional, can be zero or null Distillation loss fraction
CFACT. [NUMB 5,1] CHARACTERIZATION FACTOR Optional, can be zero or null
GCOM. [CHAR 240] GENERAL COMMENT Optional, can be null Free form general comment
GENERAL EDITS
WTCNUM [CHAR 13] AER WTC Tracking ID Will not be Blank, system will input AER-WTC Unique Certification number:
WTCDAT [YYYY MM DD HHHH] Submission/Acceptance Date Will not be Blank, system will input Date of WTC Verification & Acceptance
WTCSUB [CHAR 60] Submitter Will not be Blank, system will input Company whom Submitted Specific Well Test Data
COMP. [CHAR 60] Licensee Name Will not be Blank, system will input Based on Licensee
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
PASTYPE. [CHAR 7] DIGITAL DATA - WATER ANALYSIS PAS-WAN Water Analysis test, format
UNIT. [CHAR 1] UNITS FLAG (M)etric Metric Units for AER submission
VERS. [NUMB 5,2] AER DIGITAL WELL TEST DATA 4.00 Current AER version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
FORM. [CHAR 20] FORMATION NAME Name of the geological formation/zone
WSFL. [NUMB 2] WELL FLUID TYPE AT TEST DATE Mandatory, must have a valid AER fluid code = Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
(01) Oil, (02) Gas, (06) Water, or (17) Crude
Bitumen
~ TEST DATA
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
LABCO. [CHAR 60] LABORATORY NAME Company name conducting analysis
LFNUM. [CHAR 25] LABORATORY FILE NUMBER Identification number
TTOPL.M [NUMB 6,2] TEST/PROD. INTERVAL TOP M KB (LOG) [TTOPL] (Interval Top - Log) must be > 0.0 and < Top of tested or producing interval - in log depth, measured mKB
[TBASL] (Interval Base - Log)
TBASL.M [NUMB 6,2] TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and Base of tested or producing interval - in log depth, measured mKB
=> [TTOPL] (Interval Top - Log) and cannot be
greater than Total Well Depth.
SDAT.DAY [YYYY MM DD] DATE SAMPLED Must be >= Spud Date and <= Abandoned Date Date sample gathered
and <= Submission Date
IDENT. [CHAR 12] CONTAINER IDENTITY Identification code of container
WANC. [CHAR 240] COMMENT ON SAMPLE Optional General Free form Comment (regarding Sample or Analytical
Procedures).
~ WATER CATIONS
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
NA.MG/L [NUMB 9,2] SODIUM CATION Mandatory, can be zero Sodium mg/L
NA.MEQ/L [NUMB 9,2] SODIUM CATION CONCENTRATION Mandatory, can be zero Sodium milli-equivalent
K.MG/L [NUMB 9,2] POTASSIUM CATION Mandatory, can be zero Potassium mg/L
K.MEQ/L [NUMB 9,2] POTASSIUM CATION CONCENTRATION Mandatory, can be zero Potassium milli-equivalent
CA.MG/L [NUMB 9,2] CALCIUM CATION Mandatory, can be zero Calcium mg/L
CA.MEQ/L [NUMB 9,2] CALCIUM CATION CONCENTRATION Mandatory, can be zero Calcium milli-equivalent
MG.MG/L [NUMB 9,2] MAGNESIUM CATION Mandatory, can be zero Magnesium mg/L
MG.MEQ/L [NUMB 9,2] MAGNESIUM CATION CONCENTRATION Mandatory, can be zero Magnesium milli-equivalent
BA.MG/L [NUMB 9,2] BARIUM CATION Optional, can be zero Barium mg/L
BA.MEQ/L [NUMB 9,2] BARIUM CATION CONCENTRATION Optional, can be zero Barium milli-equivalent
SR.MG/L [NUMB 9,2] STRONTIUM CATION Optional, can be zero Strontium mg/L
SR.MEQ/L [NUMB 9,2] STRONTIUM CATION CONCENTRATION Optional, can be zero Strontium milli-equivalent
FE.MG/L [NUMB 9,2] IRON CATION Optional, can be zero Iron mg/L
FE.MEQ/L [NUMB 9,2] IRON CATION Optional, can be zero Iron milli-equivalent
CONCENTRATION
MN.MG/L [NUMB 9,2] MANGANESE CATION Optional, can be zero Manganese mg/L
MN.MEQ/L [NUMB 9,2] MANGANESE CATION CONCENTRATION Optional, can be zero Manganese milli-equivalent
B.MG/L [NUMB 9,2] BORON CATION Optional, can be zero Boron mg/L
B.MEQ/L [NUMB 9,2] BORON CATION CONCENTRATION Optional, can be zero Boron milli-equivalent
OH.MG/L [NUMB 9,2] HYDROXIDE ANION Mandatory, can be zero Hydroxide mg/L
OH.MEQ/L [NUMB 9,2] HYDROXIDE ANION CONCENTRATION Mandatory, can be zero Hydroxide milli-equivalent
DSCAL.MG/L [NUMB 9,2] TOTAL DISSOLVED SOLIDS CALCULATED Must be > 0.0 mg/L
GENERAL EDITS
WTCNUM [CHAR 13] AER WTC Tracking ID Will not be Blank, system will input AER-WTC Unique Certification number:
WTCDAT [YYYY MM DD HHHH] Submission/Acceptance Date Will not be Blank, system will input Date of WTC Verification & Acceptance
WTCSUB [CHAR 60] Submitter Will not be Blank, system will input Company whom Submitted Specific Well Test Data
COMP. [CHAR 60] Licensee Name Will not be Blank, system will input Based on Licensee
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
PASTYPE. [CHAR 7] DIGITAL DATA - DST TEST DATA PAS-DST Drill Stem Test, format
UNIT. [CHAR 1] UNITS FLAG (M)etric Metric Units for AER submission
VERS. [NUMB 5,2] AER DIGITAL WELL TEST DATA 4.00 Current AER version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
POOL. [CHAR 1] AER DESIGNATED POOL Must be either (Y)es or (N)o. Within AER Defined Pool / G-Order at time of Drilling? Gas and
Fluid Sampling Regulatory Requirements in accordance with AER
Guide 40.
WTYP. [CHAR 1] WELL TYPE INDICATOR Mandatory, if [PRPS] (Purpose Indicator) = (I)nitial. Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore
Must be (V)ertical, (D)eviated or (H)orizontal
DPID.MM [NUMB 4,1] DRILL PIPE ID Must be < 200 Inside diameter of drilling pipe (mm)
SERCO. [CHAR 5] SERVICE COMPANY CODE Company conducting test (see AER Website)
CCCO. [CHAR 20] CLOSED CHAMBER COMPANY Mandatory, if [TTYP] (DST Test Type Code) = (08) Name of Company Conducting Closed Chamber Test
or (18).
TTYP. [CHAR 2] DST TEST TYPE CODE Must be Valid AER PAS-DST Test Code (See
Footnote).
RUNUM. [NUMB 2] RUN NUMBER Run Number / Trip Number into Hole - for Testing
TNUM. [NUMB 4] DST NUMBER DST Number (i.e. DST no.3)
H2SIND. [CHAR 1] H2S INDICATOR Must be (Y)es or (N)one. Flag indicating presence of H2S
TTOPL.M [NUMB 6,2] TEST/PROD INTERVAL TOP M KB (LOG) [TTOPL] (Interval Top - Log) must be > 0.0 and < Top of tested or producing interval - in log depth, measured mKB
[TBASL] (Interval Base - Log)
TBASL.M [NUMB 6,2] TEST/PROD INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and Base of tested or producing interval - in log depth, measured mKB
=> [TTOPL] (Interval Top - Log) and cannot be
greater than Total Well Depth.
TTOPT.M [NUMB 6,2] TEST/PROD INTERVAL TOP M KB (TVD) If [PRPS] (Purpose Indicator) = (I)nitial. If [WTYP] Top of tested or producing interval - in true vertical depth,
(Well Type Indicator) = (D)eviated or (H)orizontal, calculated mKB
then [TTOPT] (Interval Top - TVD) must be <
[TTOPL] (Interval Base - Log), else if [WTYP] =
(V)ertical, then [TTOPT] must = [TTOPL]
TBAST.M [NUMB 6,2] TEST/PROD INTERVAL BASE M KB (TVD) If [PRPS] (Purpose Indicator) = (I)nitial. If [WTYP] Base of tested or producing interval in true vertical depth,
(Well Type Indicator) = (D)eviated or (H)orizontal, calculated mKB
then [TBAST] (Interval Base - TVD) must be <
[TBASL] (Interval Base - Log), else if [WTYP] =
(V)ertical, then [TBAST] must = [TBASL]
FTDT.DAY/HR [YYYY MM DD HHHH] TEST FINAL DATE/TIME Must be >= Spud Date and <= Abandoned Date Date/Time test ended
and <= Submission Date
MSRN. [CHAR 1] TEST MISRUN INDICATOR Must be (Y)es or (N)o. If [MSRN] = (Y)es then Flag indicating Misrun of Test
[PRPS] (Test Purpose) must = (O)ther
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
GSERU. [CHAR 20] GAUGE SERIAL NUMBER USED IN Mandatory Serial number of Gauge/Recorder used for representative reservoir
SUMMARY pressure
SDGAL.M [NUMB 10,5] REPRESENTATIVE GAUGE DEPTH M Must be <= [TBASL] (Interval Base - Log) (LOG) Depth of Gauge/Recorder, representative of reservoir
(LOG)
SDGAT.M [NUMB 10,5] REPRESENTATIVE GAUGE DEPTH M Mandatory, if [PRPS] (Test Purpose Indicator) = (TVD) Depth of Gauge/Recorder, representative of reservoir
(TVD) (I)nitial, else Optional. If present and [WTYP]
(Well Type Indicator) = (D)eviated or (H)orizontal;
[SDGAT] (Representative Gauge Depth - TVD)
must be <= [SDGAL] (Representative Gauge
Depth - Log), else [SDGAT must = [SDGAL]
PRGA.KPAA [NUMB 8,2] PRESSURE AT GAUGE DEPTH KPAA Mandatory, if [MSRN] (Test Misrun Indicator) = Most representative shut-in pressure recorded at Gauge/Recorder
(N)o, otherwise can be Null Depth
PEXTR.KPAA [NUMB 8,2] REPRESENTATIVE EXTRAP/ FALSE Mandatory, if [PRPS] (Test Purpose) = (I)nitial
PRESSURE Pressure; Must match one entry of [PEXTR] from
[DTFG (n)] Table. Must be => than [PRGA]
(Gauge Pressure at End of Stage) but cannot
exceed [PRGA] by > 6%.
PRFFG.KPAA [NUMB 8,2] FINAL FLOWING PRESSURE AT GAUGE Mandatory, if [MSRN] (Test Misrun Indicator) = Final Measured Representative Flowing Gauge/Recorder Pressure
DEPTH KPAA (N)o kPaa
STGR.KPA/M [NUMB 5,3] REPRESENTATIVE PRESSURE GRADIENT Mandatory, if [PRPS] (Test Purpose Indicator) =
(I)nitial. Can not be zero. IF [MSRN] (Test Misrun
Indicator) = (Y)es, can be null.
CUIL.M [NUMB 10,5] INITIAL CUSHION LENGTH If CUTP (Cushion Type Code) <> (0) or (3) then The length of cushion present during test (m)
CUIL (Initial Cushion Length) must be present.
LCGR.KPA/M [NUMB 5,3] LIQUID CUSHION GRADIENT If CUTP (Cushion Type Code) <> (0) or (3), then Gradient of liquid portion of cushion (kPa/m)
LCGR (Liquid Cushion Gradient) must be present.
RPXX. [CHAR 1] RECOVERY VOLUME TYPE INDICATOR Must be (V)olume, (H)eight in Metres, or (N)one. If Flag indicating unit of measure for Recovered amounts
[MTST] (Multiple Test Recovery Indicator) = (Y)es,
then [RPXX] (recovery Volume Type Indicator) can
not = (N)one.
RXXC. [NUMB 3] RECOVERY TYPE CODE [RXXC] (Recovery Fluid Type Code) must be valid Recovery Type Code
AER Code (see footnote)
RXXD. [CHAR 30] RECOVERIES DESCRIPTION Description must be provided if [RPXX] (Recovery Description of Recoveries
Volume Indicator) = (V)olume or (H)eight
~ DTREC
GSER. [CHAR 20] GAUGE SERIAL NUMBER One Gauge must match [GSERU] (Gauge Serial Serial or Reference number of Gauge/Recorder.
Number used in Summary) Note: Number required for the ability to audit gauge data.
GTYP. [CHAR 30] GAUGE TYPE Type of gauge used (mechanical or electronic, model)
GMAN. [CHAR 60] GAUGE MANUFACTURER Name of manufacturer of Gauge/Recorder
GRNG.KPAA [NUMB 8,2] MAXIMUM RECORDER RANGE Full scale pressure range of Gauge/Recorder (kPaa)
GCAL.DAY [YYYY MM DD] DATE OF LAST CALIBRATION Must be < = [FTDT] (Final Test Date/Time) Date source Gauge/Recorder last calibrated
GRES. [NUMB 6,5] RESOLUTION % OF FULL-SCALE Published Resolution of Gauge/Recorder (Percentage)
GACC. [NUMB 6,5] ACCURACY % OF FULL-SCALE Published accuracy of Gauge/Recorder (Percentage)
SDGL.M [NUMB 10,5] GAUGE RUN DEPTH M KB (LOG) Gauge/Recorder depth (Measured Depth/LOG) in mKB
SDGT.M [NUMB 10,5] GAUGE RUN DEPTH M KB (TVD) Mandatory, if [WTYP] (Well Type) = (D)eviated or Gauge/Recorder depth (Calculated Depth/TVD) in mKB
(H)orizontal
GPOS. [CHAR 1] GAUGE POSITION INDICTOR [GPOS] (Gauge Position Indicator) must be Flag indicating position of Gauge/Recorder - (I)nside, (O)utside,
(I)nside, (O)utside, (R)ecovery, (B)elow Straddle, Fluid/(R)ecovery, (B)elow Straddle, I(N)flate, of (U)nknown/Other
I(N)flate, or (U)nknown/Other. IF [GSERU] =
[GSER] [GPOS] can not be = (U)nknown/Other
STGE. [CHAR 2] STAGE NUMBER If [MSRN] (Test Misrun Indicator) = (Y)es, can be Test stage number
null
FSTGC. [CHAR 22] STAGE DESCRIPTION If [MSRN] (Test Misrun Indicator) = (Y)es, can be (i.e. Initial Hydrostatic, Start of 1st Flow)
null
PRGA.KPAA [NUMB 8,2] GAUGE PRESSURE AT END OF STAGE Mandatory, if [MSRN] (Test Misrun Indicator) = Primary Gauge/Recorder pressure
(N)o, else can be null
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
TSTD.MIN [NUMB 10,5] STAGE DURATION MINUTES If [MSRN] (Test Misrun Indicator) = (Y)es, can be Duration of stage
null. One occurrence per table must be > 0.0
PEXTR.KPAA [NUMB 8,2] REPRESENTATIVE EXTRAP/ FALSE Mandatory, if [PRPS] (Test Purpose) = (I)nitial, at
PRESSURE least one occurrence of [PEXTR] must be present
in table. Must be >= [PRGA] (Gauge Pressure at
End of Same Stage) but cannot exceed [PRGA] by
> 6%.
QGFF.E3M3/D [NUMB 13,4] FINAL GAS FLOW RATE Mandatory if [MSRN] (Test Misrun Indicator) = Flow Rate of Gas, at end of stage (103m3/d).
(N)o, and at least one occurrence per table, can
be zero. Else can be Null.
QOFF.M3/D [NUMB 13,4] FINAL OIL FLOW RATE Mandatory if [MSRN] (Test Misrun Indicator) = Flow Rate of Oil, at end of stage (m3/d).
(N)o, and at least one occurrence per table, can
be zero. Else can be Null.
QWFF.M3/D [NUMB 13,4] FINAL WATER FLOW RATE Mandatory if [MSRN] (Test Misrun Indicator) = Flow Rate of Water, at end of stage (m3/d).
(N)o, and at least one occurrence per table, can
be zero. Else can be Null.
~ DTFG (n)
# {IF [MSRN] = (N)o and [PRPS] (Purpose Indicator) = (O)ther, then there must be a minimum of 5 lines of data in the [DTFG (n)] table}
# {IF [MSRN] = (N)o and [PRPS] (Purpose Indicator) = (I)nitial, then there must be a minimum of 8 lines of data in the [DTFG (n)] table; and a minimum 1 occurrence of [PEXTR] must exist}
PRGA.KPAA [NUMB 8,2] GAUGE PRESSURE KPAA Pressure measured at that interval in time via source
Gauge/Recorder
TGA.DEGC [NUMB 5,2] GAUGE TEMPERATURE Temperature measured at that interval in time via source
Gauge/Recorder (DegC)
GCOM. [CHAR 240] GENERAL COMMENT Optional Free form comment
~ DTG (n)
SDPT.KPAA/MIN [NUMB 8,2] SURFACE DP/DT KPAA/MIN Mandatory, if [TTYP] (Test Type Indicator) = (08) Change in Surface pressure/time
or (18). Can be zero and can be negative.
PSUR.KPAA [NUMB 8,2] SURFACE PRESSURE Mandatory, if [TTYP] (Test Type Indicator) = (08) Surface pressure (kPaa)
or (18). Can not be zero
RDPT.KPAA/MIN [NUMB 8,2] RECOVERY DP/DT KPAA/MIN Optional, if provided can be zero. Change in recovery pressure/time
PRCV.KPAA [NUMB 8,2] RECOVERY PRESSURE Optional, if provided can not be zero. Recovery pressure (kPaa)
QCCLIQ.M3/D [NUMB 13,4] CALC LIQUID RATE Mandatory, if [TTYP] (Test Type Indicator) = (08) m3/d
or (18), and Can be zero
QCCGAS.E3M3/D [NUMB 13,4] CALC GAS RATE Mandatory, if [TTYP] (Test Type Indicator) = (08) 103m3/d
or (18), and Can be zero
~ DTCC
07 DST - Bottomhole
08 DST- Bottomhole & Closed Chamber
17 DST- Straddle
18 DST - Straddle & Closed Chamber
46 RFT (Repeat Formation Tester) <--------------- Currently
47 MDT (Modular Dynamic Tester) <--------------- Omitting
48 WFT (Wireline Formation Tester) <--------------- these
49 FRT (Flow Rate Tester) <--------------- Test Types
GENERAL EDITS
ALL Mnemonic Values are Mandatory, unless otherwise noted.
"Conditional" Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18)
Zero's are NOT acceptable unless otherwise noted.
# WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS
ALL DEPTHS (for DST) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation
ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date
All Depths must be less than 7,000.00 M
All Pressures must be less than 150,000.00 kPa
All Temperatures (unless otherwise noted) must be between -100 and 1,000°C
All Times must be less than 100,000.0 Hours
All gas production rates must be less than 100,000.00 E3M3/day
All oil and water rates must be less than 100,000.00 M3/day
IF [FLEXP] = (01) Oil, then [STGR] should be > 1.500 and <= 9.974 kPa/m
IF [FLEXP] = (02) Gas, then [STGR] should be > 0.001 <= 5.999 kPa/m
IF [FLEXP] = (06) Water or (17) Crude Bitumen, then [STGR] should be >= 9.975 and < 16.000 kPa/m
WTCNUM [CHAR 13] AER WTC Tracking ID Will not be Blank, system will input AER-WTC Unique Certification number:
WTCDAT [YYYY MM DD HHHH] Submission/Acceptance Date Will not be Blank, system will input Date of WTC Verification & Acceptance
WTCSUB [CHAR 60] Submitter Will not be Blank, system will input Company whom Submitted Specific Well Test Data
COMP. [CHAR 60] Licensee Name Will not be Blank, system will input Based on Licensee
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
PASTYPE. [CHAR 7] DIGITAL DATA - PRODUCTION TEST DATA PAS-PRD Field Production Notes - test information, format
UNIT. [CHAR 1] UNITS FLAG (M)etric Metric Units for AER submission
VERS. [NUMB 5,2] AER DIGITAL WELL TEST DATA 4.00 Current AER version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
FORM. [CHAR 20] FORMATION NAME Name of the geological formation/zone
WSFL. [NUMB 2] WELL FLUID TYPE AT TEST DATE Must have a valid AER fluid code = (01) Oil, (02) Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
Gas, (06) Water, or (17) Crude Bitumen
~ TEST DATA
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
SERCO. [CHAR 5] SERVICE COMPANY CODE Company conducting test (see AER Website)
RRUN. [CHAR 1] RECORDERS RUN must be (Y)es or (N)o Flag indicating Pressure Gauges ran during operations
TTOPL.M [NUMB 6,2] TEST/PROD. INTERVAL TOP M KB (LOG) [TTOPL] (Interval Top - Log) must be > 0.0 and < Top of tested or producing interval - in log depth, measured mKB
[TBASL] (Interval Base - Log)
TBASL.M [NUMB 6,2] TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and Base of tested or producing interval - in log depth, measured mKB
=> [TTOPL] (Interval Top - Log) and cannot be
greater than Total Well Depth.
FTDT.DAY/HR [YYYY MM DD HHHH] TEST FINAL DATE/TIME Must be >= Spud Date and <= Abandoned Date Date/time of last measured flowrate
and <= Submission Date
FLGAS.E3M3 [NUMB 13,4] GAS FLARED E3M3 Mandatory, must be >= 0.0 (103m3) Over duration of reported production in DTSUM Table
INGAS.E3M3 [NUMB 13,4] GAS INCINERATED E3M3 Mandatory, must be >= 0.0 (103m3) Over duration of reported production in DTSUM Table
PLGAS.E3M3 [NUMB 13,4] GAS PRODUCED TO PIPELINE E3M3 Mandatory, must be >= 0.0 (103m3) Over duration of reported production in DTSUM Table
VNGAS.E2M3 [NUMB 13,4] GAS VENTED E3M3 Mandatory, must be >= 0.0 (103m3) Over duration of reported production in DTSUM Table
TAPL. [CHAR 1] TAP LOCATION INDICATOR If [MDTYPE] (Metering Device Type Indicator) = Flag indicating location of taps (U)p Stream or (D)own stream
(O)rifice, then must indicate (U)p Stream or
(D)own Stream.
RSIZ.MM [NUMB 8,3] METER RUN / PROVER SIZE Mandatory, must be => 0.0 if [MDTYPE] (Metering Inside diameter of Meter Run / Prover
Device Type Indicator) = (P)rover, (O)rifice,
P(i)tiot, or (V)-Cone
TCON.PULSES/M3 [NUMB 10,5] TURBINE DEVICE CONSTANT Mandatory, if [MDTYPE] (Metering Device Type
Indicator) = (T)urbine.
ICON. [NUMB 10,5] PITIOT TUBE DEVICE CONSTANT Mandatory, if [MDTYPE] (Metering Device Type
Indicator) = P(i)tiot
BETA. [NUMB 10,7] V-CONE BETA RATIO Mandatory, if [MDTYPE] (Metering Device Type V-Cone beta ratio
Indicator) = (V), else can be Null. Can be zero.
MCOF. [NUMB 10,7] V-CONE METER COEFFICIENT Mandatory, if [MDTYPE] (Metering Device Type V-Cone Meter coefficient
Indicator) = (V), else can be Null. Can be zero.
MCOMG. [CHAR 240] COMMENT - GAS METER Provides additional information about the meter being used
PLATE.MM [NUMB 8,3] ORIFICE /CHOKE PLATE SIZE Mandatory, if [MDTYPE] (Metering Device Type
Indicator) = (C)hoke or (O)rifice, else null. Can be
zero
STAG.KPAA [NUMB 8,2] METER PRESSURE (GAS) Pressure used for Super Compressibility Calculation
DIFG.KPA [NUMB 8,2] PRESSURE DIFFERENTIAL (GAS) Mandatory, if [MDTYPE] (Metering Device Type (kPa)
Indicator) = (C)hoke, (O)rifice, P(i)tiot, or (V)-Cone,
else can be zero or NULL
TMPG.DEGC [NUMB 5,2] METER TEMPERATURE Temperature used for Super Compressibility Calculation
TRBG.PULSE [NUMB 8,3 14,3] TURBINE METER READING Mandatory, if [MDTYPE] (Metering Device Type
Indicator) = (T)urbine, else must be Null.
N2.FRAC [NUMB 5,4] NITROGEN MOLE FRACTION Optional
CO2.FRAC [NUMB 5,4] CARBON DIOXIDE MOLE FRACTION Optional
RCOMP. [CHAR 240] GAS COMPOSITION COMMENT Optional Gas composition as measured throughout the test
~ DTGAS (n)
TIME QGAS H2S PLATE STAG
YYYY MM DD HHHH:SS 999999999.9999 9.9999 99999.999 999999.99
YYYY MM DD HHHH:SS 999999999.9999 9.9999 99999.999 999999.99
YYYY MM DD HHHH:SS 999999999.9999 9.9999 99999.999 999999.99
TCON.PULSE/M3 [NUMB 10,5] TURBINE DEVICE K-FACTOR Mandatory, if [LQMTYP] (Metering Device Type Manufacturer specific K-Factor
Indicator) = (T)urbine, then must provide K-Factor
TMEA. [CHAR 1] TANK MEASUREMENT INDICATOR Mandatory, if [LQMTYP] (Metering Device Type Flag indicating (I)ncremental or (C)umulative measurement
Indicator) = (L)evel or (V)olume, then must indicate
if measurement is (I)ncremental or (C)umulative
else can be Null
TEQU. [CHAR 240] TANK EQUATION Mandatory, if [LQMTYP] (Metering Device Type Equation illustration
Indicator) = (L)evel, must provide tank
measurement and volume equation.
MCOML. [CHAR 240] COMMENT - LIQUID METER Provides additional information about the meter being used
GNVF.M3 [NUMB 8,3] TANK GAIN VOLUME Mandatory, if [LQMTYP] (Metering Device Type
Indicator) = (L)evel or (V)olume, and at least one
value > = 0.00 must appear in table.
TRBF.PULSE [NUMB 14,3 ] TURBINE METER READING Mandatory, if [LQMTYP] (Metering Device Type
Indicator) = (T)urbine
API. [NUMB 4,2] API GRAVITY @ 15 DegC Optional. If present, can not be zero. Measured Gravity of Produced Oil, Degrees API
BSW.FRAC [NUMB 4,3] FRACTION OF TOTAL BS&W Mandatory, if [LIQT] (Liquid Type Indicator) = (O)iI, Basic sand and water volume fraction, total
and at least one value > = 0.00 must appear in
table.
SALT.PPM [NUMB 8,0] SALINITY PPM Optional. If present, can be zero. Salinity of produced fluid (PPM)
PH. [NUMB 3,1] PH Optional. If present must be >0 and < 14. pH concentration of produced fluid
OILRATE.M3/D [NUMB 13,4] OIL RATE Mandatory, if Meter Liquid (n) [LIQT] (Liquid Type Produced oil only, not load or frac oil
Indicator) = (O)il and at least one value >0.00 must
appear in table.
CONRATE.M3/D [NUMB 13,4] CONDENSATE RATE Mandatory, if, Meter Liquid (n) [LIQT] (Liquid Type
Indicator) = (C)ondensate and at least one value
>0.00 must appear in table.
WTRRATE.M3/D [NUMB 13,4] WATER RATE Mandatory, if, Meter Liquid (n) [LIQT] (Liquid Type
Indicator) = (W)ater and at least one value >0.00
must appear in table.
QLIQ.M3/D [NUMB 13,4] MEASURED TOTAL LIQUID RATE Must = [OILRATE] (Oil Rate) + [CONRATE] Total Combined Liquid Rate
(Condensate Rate) + [WTRRATE] (Water Rate)
VTOIL.M3 [NUMB 13,4] CUMULATIVE TOTAL OIL VOLUME ALL Can be zero. Cumulative volume produced during test. Produced oil only, not
METERS load or frac oil
VTCON.M3 [NUMB 13,4] CUMULATIVE TOTAL CONDENSATE Can be zero. Cumulative volume produced during test
VOLUME ALL METERS
VTWTR.M3 [NUMB 13,4] CUMULATIVE TOTAL WATER VOLUME Can be zero. Cumulative volume produced during test
ALL METERS
COMM. [CHAR 240] COMMENT General Test Comments (i.e. Text Descriptions regarding specific
operations)
GENERAL EDITS
WTCNUM [CHAR 13] AER WTC Tracking ID Will not be Blank, system will input AER-WTC Unique Certification number:
WTCDAT [YYYY MM DD HHHH] Submission/Acceptance Date Will not be Blank, system will input Date of WTC Verification & Acceptance
WTCSUB [CHAR 60] Submitter Will not be Blank, system will input Company whom Submitted Specific Well Test Data
COMP. [CHAR 60] Licensee Name Will not be Blank, system will input Based on Licensee
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
PASTYPE. [CHAR 7] DIGITAL DATA - GAS/GAS LIQUIDS PAS-GAN Gas Analysis test, format
ANALYSIS
UNIT. [CHAR 1] UNITS FLAG (M)etric Metric Units for AER submission
VERS. [NUMB 5,2] AER DIGITAL WELL TEST DATA 4.00 Current AER version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
FORM. [CHAR 20] FORMATION NAME Name of the geological formation/zone
WSFL. [NUMB 2] WELL FLUID TYPE AT TEST DATE Must have a valid AER fluid code = (01) Oil, (02) Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
Gas, (06) Water, or (17) Crude Bitumen
~ TEST DATA
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
LABCO. [CHAR 60] LABORATORY NAME Company name conducting analysis
TTOPL.M [NUMB 6,2] TEST/PROD. INTERVAL TOP M KB (LOG) [TTOPL] (Interval Top - Log) must be > 0.0 and < Top of tested or producing interval - in log depth, measured mKB
[TBASL] (Interval Base - Log)
TBASL.M [NUMB 6,2] TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and Base of tested or producing interval - in log depth, measured mKB
=> [TTOPL] (Interval Top - Log) and cannot be
greater than Total Well Depth.
HYDLP. [CHAR 1] HYDROCARBON LIQUIDS PRODUCTION Must be = (Y)es or (N)o. If [HYDLP] (Hydrocarbon Flag indicating measurable liquid production (Y)es or (N)o
Liquid Production) = (Y)es, then [DTCL] (Data
Table - Condensate / Liquid Analysis) can not be
null.
GANC. [CHAR 240] COMMENT ON SAMPLE Optional General Free form Comment (regarding Sample or Analytical
Procedures).
~ DTFSGAS
# {Total for FIRST STAGE SEPARATOR GAS ANALYSIS [all mole fractions] MUST TOTAL 1.000 plus or minus 0.001 for rounding.}
COMPCOM MOLG MOLAGF LIQVOl
FS-H2S.FRAC 9.9999 ---------- ----------
FS-CO2.FRAC 9.9999 ---------- ----------
FS-N2.FRAC 9.9999 9.9999 ----------
FS-H2.FRAC 9.9999 9.9999 ----------
FS-HE.FRAC 9.9999 9.9999 ----------
FS-C1.FRAC 9.9999 9.9999 ----------
FS-C2.FRAC 9.9999 9.9999 999.9
FS-C3.FRAC 9.9999 9.9999 999.9
FS-IC4.FRAC 9.9999 9.9999 999.9
FS-NC4.FRAC 9.9999 9.9999 999.9
FS-IC5.FRAC 9.9999 9.9999 999.9
FS-NC5.FRAC 9.9999 9.9999 999.9
FS-C6.FRAC 9.9999 9.9999 999.9
FS-C7+.FRAC 9.9999 9.9999 999.9
GHV.MJ/M3 [NUMB 4,2] CALC GROSS HEAT VALUE MOISTURE Can not be zero
FREE
GHVAGF.MJ/M3 [NUMB 4,2] CALC GROSS HEAT VALUE MOISTURE & Can not be zero
ACID GAS FREE
PPVP.KPAA [NUMB 8,2] CALC C5+ VAPOUR PRESSURE (KPAA) Optional
FS-PPC.KPAA [NUMB 8,2] CALC PSEUDO CRITICAL PRESSURE AS Can not be zero First Stage Separator - PPC (kPaa)
SAMPLED
FS-PTC.DEGK [NUMB 5,2] CALC PSEUDO CRITICAL TEMPERATURE Can not be zero First Stage Separator - PTC (Degrees Kelvin)
AS SAMPLED (DegK)
FS-PPCAGF.KPAA [NUMB 8,2] CALC PSEUDO CRITICAL PRESSURE Can not be zero First Stage Separator - PPC - Acid Gas Free (kPaa)
ACID GAS FREE
FS-PTCAGF.DEGK [NUMB 5,2] CALC PSEUDO CRITICAL TEMPERATURE Can not be zero First Stage Separator - PTC - Acid Gas Free (Degrees Kelvin)
ACID GAS FREE (DegK)
H2SLC. [CHAR 1] LOCATION OF H2S MEASUREMENT Mandatory, must indicate location of measurement Location of H2S measurement.
(F)ield, (L)ab or (B)oth. 1 PPM = (0.000001 MOL FRAC) or (0.0001 MOL %)
H2SMT. [CHAR 1] METHOD OF FIELD ANALYSIS Mandatory, if [H2SLC] (Location of H2S Method of H2S detection.
Measurement) = (F)ield or (B)oth. [H2SMT] must =
(T)utwieler, (L)itmus, (C)hromatograph, (O)ther,
(S)tain Tube or (N)ot Measured.
Must be null if [H2SLC] = (L)ab.
LABH2S.FRAC [NUMB 5,4] LABORATORY H2S ANALYSIS Mandatory, if [H2SLC] (Location of H2S H2S fraction measured in the lab.
Measurement) = (L)ab or (B)oth. Can be zero.
C7+DN. [NUMB 4,1] DENSITY OF C7+ FRACTION Mandatory, if [FS-C7+.FRAC] (Heptane Plus)
>0.0000, else must be Null Optional
C7+MW. [NUMB 3,1] MOLE WEIGHT C7+ FRACTION Mandatory, if [FS-C7+.FRAC] (Heptane Plus)
>0.0000, else must be Null Optional
SS-RTEMP.DEGC [NUMB 5,2] RECEIVED TEMPERATURE Can be zero Second Stage Separator Temperature as received (in Lab) - DegC
SS-ADAT.DAY [YYYY MM DD] DATE ANALYZED Must be >= [SS-SDAT] (Date Sampled) and <= Date in which Second Stage Separator sample was analyzed
Submission Date
~ DTCL
LH2S.PPM [NUMB 3,1] LIQUID H2S PPM Can be zero. Can be null. H2S in Parts per Million (<= 99.9, or 0.0000999 MOL FRAC).
Note: Any Indication of Trace Liquid H2S, if not sampled, should be
recorded in ~Test Data [GANC] (Comment on Sample).
LIQRDN. [NUMB 4, 3] CALC REL DENSITY OF TOTAL SAMPLE @ Must be < 1 Calculated Relative Density of Condensate / Liquid Sample
15 DegC
LIQRMW. [NUMB 4,1] CALC REL MOLE MASS OF TOTAL Calculated Relative Molar Mass of Condensate / Liquid Sample
SAMPLE @ 15 DegC
RDLIQ RELMM
9.999 999
9.999 999
9.999 999
9.999 999
FS-GAS.E3M3/D [NUMB 13,4] FIRST STAGE GAS RATE If [STYP] (Sample Type) = (R)ecombination and 103m3/d
[SEPCOND] (Separator Conditions) = (F)irst or
(B)oth, then cannot be null.
SS-GAS.E3M3/D [NUMB 13,4] SECOND STAGE GAS RATE If [STYP] (Sample Type) = (R)ecombination and 103m3/d
[SEPCOND] (Separator Conditions) = (B)oth, then
cannot be null.
LIQRAT.M3/D [NUMB 13,4] LIQUID RATE Mandatory, if STYP= 'R' The separator liquid rate used for the recombination.
LIQGPT. [CHAR 1] LIQUID GATHERING POINT If [STYP] (Sample Type) = (R)ecombination, then
[LIQGPT] Must be (F)irst Stage Separator,
(S)econd Stage Separator or Stock (T)ank.
LIQMM. [NUMB 4,1] LIQUID MOLECULAR MASS g/mol Mandatory, if [STYP] (Sample Type) =
(R)ecombination
LIQRDN. [NUMB 4, 3] DENSITY OF LIQUID kg/m 3 Mandatory, if [STYP] (Sample Type) = DENSITY OF LIQUID kg/m3 AT MEASURED CONDITIONS
(R)ecombination
20 First Stage Separator ALL Mnemonic Values are Mandatory, unless otherwise noted.
25 Second Stage Separator "Conditional" Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18)
30 Wellhead Zero's are NOT acceptable unless otherwise noted.
35 Meter Run # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS
40 Pressure Tank ALL DEPTHS (for GAN) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation
45 Downhole Samplers - Post Drilling ( i.e. RFT's, MDT's etc.) ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date
50 DST All Depths must be less than 7,000.00 M
60 Tubing All Pressures must be less than 150,000.00 kPa
70 Other (Miscellaneous) All Temperatures (unless otherwise noted) must be between -100 and 1,000°C
All Times must be less than 100,000.0 Hours
All gas production rates must be less than 100,000.00 E3M3/day
All oil and water rates must be less than 100,000.00 M3/day
All mole fractions must total 1.0000 plus or minus .001 for rounding
Image Attachment required if Extended Component Analysis performed
Estimated Non-Critical
Ranges
CO2 CARBON DIOXIDE < = 5%
N2 NITROGEN < = 10% TRACE COMPONENTS (How To Report):
H2 HYDROGEN < = 0.1% For Tables ~DTFSGAS, ~DTCL, 2nd Stage Separator and/or Recombined Gas Composition components
HE HELIUM < = 0.1% report all "Trace" values (with the exception of "H2S - Hydrogen Sulphide" )
C1 METHANE < = 50% as 0.0001.FRAC, and use a comment line starting with "#" to qualify the situation(s).
C2 ETHANE < = 15%
C3 PROPANE < = 5%
IC4 ISO-BUTANE < = 1%
NC4 N-BUTANE < = 2%
IC5 ISO-PENTANE < = 1%
NC5 N-PENTANE < = 1%
C6 HEXANE < = 1%
C7+ HEPTANE PLUS < = 1%
WTCNUM [CHAR 13] AER WTC Tracking ID Will not be Blank, system will input AER-WTC Unique Certification number:
WTCDAT [YYYY MM DD HHHH] Submission/Acceptance Date Will not be Blank, system will input Date of WTC Verification & Acceptance
WTCSUB [CHAR 60] Submitter Will not be Blank, system will input Company whom Submitted Specific Well Test Data
COMP. [CHAR 60] Licensee Name Will not be Blank, system will input Based on Licensee
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
Static Pressure Test, format. This file is for the reporting of both
"Static" Pressure measurements (Gradients, Acoustic Well
PASTYPE. [CHAR 7] DIGITAL DATA - GRADIENT TEST DATA PAS-GRD
Sounders, or Deadweight Tester) and "Flowing" Gradient well test
data.
UNIT. [CHAR 1] UNITS FLAG (M)etric Metric Units for AER submission
VERS. [NUMB 5,2] AER DIGITAL WELL TEST DATA 4.00 Current AER version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
FORM. [CHAR 20] FORMATION NAME Name of the geological formation/zone
WSFL. [NUMB 2] WELL FLUID TYPE AT TEST DATE Must have a valid AER fluid code = (01) Oil, (02) Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
Gas, (06) Water, or (17) Crude Bitumen
WTYP. [CHAR 1] WELL TYPE INDICATOR Must be (V)ertical, (D)eviated or (H)orizontal Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore
PACKER. [CHAR 1] PACKER INDICATOR FLAG Must = (Y)es or (N)o. Flag indicating presence of packer (Y)es, (N)o
TULD. [CHAR 1] TUBING IN WELL Must = (Y)es or (N)o. Flag indicating Tubing in well (Y) or (N)
AFLO. [CHAR 1] FLOW PATH Must = (A)nnular, (C)asing, (T)ubing, or (B)oth Flag indicating flow path (A)nnular, (C)asing, (T)ubing, or (B)oth
casing and tubing. casing and tubing
TUBS.MM [NUMB 4,1] INSIDE DIAMETER OF PRODUCTION Optional, if present must be > 0.00 Inside diameter of production tubing (IF TULD=Y)
TUBING
PCID.MM [NUMB 4,1] INSIDE DIAMETER OF PRODUCTION Optional, if present must be > 0.00 and must be > Inside diameter of production casing
CASING [TUBS] and [PTOD]
PTOD.MM [NUMB 4,1] OUTSIDE DIAMETER OF PRODUCTION Optional, if present must be > 0.00 and must be > Outside diameter of production tubing
TUBING [TUBS]
H2SIND. [CHAR 1] H2S INDICATOR Must = (Y)es or (N)one. Flag indicating presence of H2S
AWSVAL. [CHAR 1] AWS VALIDATION Mandatory. If [TTYP] (Test Type Indicator) = 10 Flag indicating whether Verification of Acoustic Method was
and [PRPS] (Test Purpose Indicator) = (A)nnual, undertaken and submitted (in this or previous test/image file - for
then [AWSVAL] must = (Y)es. If [TTYP] = 10 and this well), in accordance with AER Guide 40.
[PRPS] = (O)ther, then [AWSVAL] can be (Y)es,
(N)o, or Null. If [TTYP] <> 10, [AWSVAL] must be
Null.
TTOPL.M [NUMB 6,2] TEST/PROD. INTERVAL TOP M KB (LOG) [TTOPL] (Interval Top - Log) must be > 0.0 and < Top of tested or producing interval - in log depth, measured mKB.
[TBASL] (Interval Base - Log)
TBASL.M [NUMB 6,2] TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and Base of tested or producing interval - in log depth, measured mKB
=> [TTOPL] (Interval Top - Log) and cannot be
greater than Total Well Depth.
TTOPT.M [NUMB 6,2] TEST/PROD. INTERVAL TOP M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Top of tested or producing interval - in true vertical depth,
(H)orizontal, then [TTOPT] (Interval Top - TVD) calculated mKB
must be < [TTOPL] (Interval Top - Log), else if
[WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]
TBAST.M [NUMB 6,2] TEST/PROD. INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Base of tested or producing interval in true vertical depth,
(H)orizontal, then [TBAST] (Interval Base - TVD) calculated mKB
must be < [TBASL] (Interval Base - Log), else if
[WTYP] = (V)ertical, then [TBAST] must = [TBASL]
TISI.DAY/HR [YYYY MM DD HHHH] TIME/DATE WELL SHUT-IN Must be >= Spud Date but < [FTDT] (Final Test Date/time well shut-in for final BU/FO
Date and Time) and the Submission Date
CSPS.KPAA [NUMB 8,2] INITIAL CASING PRESSURE Mandatory if [AFLO] (Flow Path) = (A)nnular, Casing pressure at start of test (kPaa)
(C)asing or (B)oth, and [TTYP] (Test Type
Indicator) = (03) or (13), else can be null
FTUPS.KPAA [NUMB 8,2] FINAL TUBING PRESSURE Mandatory if [AFLO] (Flow Path) = (T)ubing or Tubing pressure at end of test (kPaa)
(B)oth, and [TTYP] (Test Type Indicator) = (03) or
(13), else can be null.
FCSPS.KPAA [NUMB 8,2] FINAL CASING PRESSURE Mandatory if [AFLO] (Flow Path) = (A)nnular, Casing pressure at end of test (kPaa)
(C)asing or (B)oth, and [TTYP] (Test Type
Indicator) = (03) or (13), else can be null
TSUR.DEGC [NUMB 5,2] SURFACE TEMPERATURE Mandatory, if [TTYP] (Test Type Indicator) = (10), Temperature measured at wellhead during operations (DegC)
(23) or (33)
QGAS.E3M3/D [NUMB 13,4] GAS PRODUCTION RATE PRIOR TO TEST Mandatory, if [TTYP] (Test Type Indicator) = (10).
Can be zero. Can be negative, if an injection well.
QOIL.M3/D [NUMB 13,4] OIL PRODUCTION RATE PRIOR TO TEST Mandatory, if [TTYP] (Test Type Indicator) = (10).
Can be zero. Can be negative, if an injection well.
QWTR.M3/D [NUMB 13,4] WATER PRODUCTION RATE PRIOR TO Mandatory, if [TTYP] (Test Type Indicator) = (10).
TEST Can be zero. Can be negative, if an injection well.
PRGA.KPAA [NUMB 8,2] PRESSURE AT STOP DEPTH KPAA Mandatory, if [TTYP] (Test Type Indicator) = 03 Representative Pressure at SDGAL
PRCOR.KPA [NUMB 8,2] PRESSURE CORRECTION Mandatory, if [TTYP] (Test Type Indicator) = 03. Pressure Differential from run depth to MPP used; negative values
Can be zero. If [SDGAL] is < [TBASL] or > if run below MPP (kPa)
[TTOPL], then [PRCOR] can not be zero.
PRGC. [CHAR 240] COMMENT ON PRESSURE Optional Freeform comment of Pressure - (i.e. comparison to trend, offsets,
shut-in time etc.) Data updates AER Pressure Summary Database.
PLIND. [CHAR 1] PRIMARY LIQUID TYPE INDICATOR Mandatory, if [WSFL] (Well Fluid Type at Test Provide type of liquid encountered
Date) = (01), (06) or (17). Must = (O)il, (W)ater,
(C)rude Bitumen, (E)mulsion or o(T)her. If present
[PLIND] (Primary Liquid Type Indicator) <>
[SLIND] (Secondary Liquid Type Indicator).
SLIND. [CHAR 1] SECONDARY LIQUID TYPE INDICATOR Mandatory, if [SLGR] (Secondary Liquid Gradient) Must provide secondary type of liquid if encountered
> 0.00, otherwise it is Optional. If present, must =
(O)il, (W)ater, (C)rude Bitumen, (E)mulsion,
o(T)her, else must be NULL. If present, [PLIND]
(Primary Liquid Type Indicator) <> [SLIND]
(Secondary Liquid Type Indicator).
GRLIQ.KPA/M [NUMB 5,3] LIQUID GRADIENT USED TO CORRECT Mandatory, if [PRPS] (Test Purpose Indicator) not (kPa/m).
TO LOG MPP = (O)ther; If [PLIND] (Primary Liquid Type
Indicator) present [GRLIQ] (Liquid Gradient used
to correct to MPP) is mandatory; if [PLIND] = (O)il
or (E)mulsion then [GRLIQ] must be > 1.5 and <
15.999; if [PLIND] = (W)ater then [GRLIQ] must
be > 9.500 and < 15.999
PLGR.KPA/M [NUMB 5,3] PRIMARY LIQUID GRADIENT (LOG) If [PLIND] (Primary Liquid Type Indicator) present,
[PLGR] (Primary Liquid Gradient) is mandatory
SLGR.KPA/M [NUMB 5,3] SECONDARY LIQUID GRADIENT (LOG) If [SLIND] (Secondary Liquid Type Indicator)
present, [SLGR] (Secondary Liquid Gradient) is
mandatory
PSUR.KPAA [NUMB 8,2] SURFACE PRESSURE Mandatory, if [TTYP] (Test Type Indicator) = 10, Corresponding casing/surface pressure at that time (kPaa)
23 or 33
METHC. [CHAR 240] METHOD OF ACOUSTIC/DEAD WEIGHT Mandatory, if [TTYP] (Test Type Indicator) = 10 or Description for method of Acoustic / DWT calculation, in
TESTER EXTRAPOLATION COMMENT 33 accordance with AER Guide 3 and Guide 5.
LLVL.M [NUMB 10,5] LIQUID LEVEL M CF (LOG) Mandatory, if [PLIND] (Primary Liquid Type Calculated Length of Gas Column, as determined by wireline or
Indicator) present, can be zero. interpreted by an Acoustic Shot - in LOG/measured depth (mCF).
Must be Null, IF both [PLIND] AND [SLIND] Note: For dry gas wells, Liquid Level (or Length of Gas Column) is
(Secondary Liquid Type Indicator) are Null. to be reported equal to MPP or Null. A depth of zero will be
interpreted as "Liquid to Surface".
LLVT.M [NUMB 10,5] LIQUID LEVEL M CF (TVD) Mandatory, if [PLIND] (Primary Liquid Type Calculated Length of Gas Column (or liquid level) for each shot
Indicator) present and if [WTYP] (Well Type (TVD). As determined by wireline or interpreted by an Acoustic - in
Indicator) = (D)eviated or (H)orizontal. Can be TVD depth, calculated mCF. Note: See [LLVL]
zero.
Must be Null, IF both [PLIND] AND [SLIND]
(Secondary Liquid Type Indicator) are Null.
PMPP.KPAA [NUMB 8,2] CALCULATED PRESSURE CORRECTED Mandatory. Can not = 0 Calculated pressure to mid-point of tested or producing interval - in
TO MPP (LOG) log depth, measured mKB
TRES.DEGC [NUMB 5,2] RESERVOIR TEMPERATURE Reservoir temperature (DegC)
DPTS. [CHAR 1] ANNULAR DEPRESSION TEST INDICATOR Mandatory, if [TTYP] (Test Type Indicator) = 10 Flag indicating whether or not an Annular Fluid/Foam Depression
and [PRPS] (Test Purpose Indicator) = (A)nnual. test was performed, in accordance with AER Guide 40. If DPTS =
Must be either (Y)es or (N)o otherwise Null. (Y). Data/information must be included within Image Attachment.
SDGAT.M [NUMB 10,5] STOP DEPTH M CF (TVD) Mandatory, if [TTYP] (Test Type Indicator) = (03) Gauge/Recorder depth (Calculated Depth/TVD) in mCF
or (13) Mandatory and if [WTYP] (well Type
Indicator) = (D)eviated or (H)orizontal , else must
be Null.
PRGA.KPAA [NUMB 8,2] STOP PRESSURE KPAA Mandatory, if [TTYP] (Test Type Indicator) = (03) Pressure measured at stop depth
or (13)
GRSDL.KPA/M [NUMB 5,3] CALCULATED GRADIENT (LOG) Mandatory, if [TTYP] (Test Type Indicator) = (03) Gradient calculated at stop depth
or (13). At least 1 row in Table must report a value
not = zero
GRSDT.KPA/M [NUMB 5,3] CALCULATED GRADIENT (TVD) Mandatory, if [TTYP] (Test Type Indicator) = (03)
or (13) Mandatory and if [WTYP] (well Type
Indicator) = (D)eviated or (H)orizontal, else must
be Null.
TGA.DEGC [NUMB 5,2] STOP TEMPERATURE Mandatory, if [TTYP] (Test Type Indicator) = (03) Gauge temperature at each stop depth
or (13). At least 1 row in Table must report a value
not = zero
~ DTSUM
# {DTSUM - Can be omitted if [TTYP] (Test Type Indicator) <> (03) or (13)}
SDGAL SDGAT PRGA GRSDL. GRSDT
99999.99999 99999.99999 999999.99 99.999 99.999
99999.99999 99999.99999 999999.99 99.999 99.999
99999.99999 99999.99999 999999.99 99.999 99.999
GOFB.DAY/HR/SS [YYYY MM DD HHHH:SS] DATE/TIME GAUGE OFF BOTTOM Mandatory, if [TTYP] (Test Type Indicator) = (03) Date/time gauge off bottom
or (13). Must be > [GONB] (Gauge On Bottom)
and <= [FTDT] (Final Test Date/Time)
TGA.DEGC [NUMB 5,2] GAUGE TEMPERATURE DEGC Temperature measured at that interval in time
GCOM. [CHAR 240] GENERAL COMMENT Optional Comment on Gauge/Events (i.e. shut-in, open-to-flow, etc.)
~ DTG (n)
TIME TCUM DGAL PRGA TGA
YYYY MM DD HHHH:SS 99999.99999 99999.99999 999999.99 999.99
YYYY MM DD HHHH:SS 99999.99999 99999.99999 999999.99 999.99
YYYY MM DD HHHH:SS 99999.99999 99999.99999 999999.99 999.99
GCOM
X(240)
X(240)
X(240)
LLVL.M [NUMB 10,5] LIQUID LEVEL M CF (LOG) Mandatory if [TTYP] (Pressure Test Type) = 10, Calculated Length of Gas Column, as determined by wireline or
can be zero. At least 1 occurrence of [LLVL] must interpreted by an Acoustic Shot - in LOG/measured depth (mCF).
exist in table. Note: For dry gas wells, Liquid Level (or Length of Gas Column) is
(note: zero = Fluid to Surface) to be reported equal to MPP or Null. A depth of zero will be
interpreted as "Liquid to Surface".
PSUR.KPAA [NUMB 8,2] SURFACE PRESSURE KPAA Mandatory, if ([TTYP] (Test Type Indicator) = 10. If
([FTDT] (Final Test Date/Time) - [TISI] (Date/Time
Well Shut-In)) < 14 days) then [PSUR] (Surface
Pressure) at the last real time in the table go back
2 hours and subtract the [PSUR] at that time) if
value is <= 2.5 kPa/hr, OK, else error.
~ DTAWS
TIME LLVL.M PSUR
YYYY MM DD HHHH:SS 99999.99999 999999.99
YYYY MM DD HHHH:SS 99999.99999 999999.99
YYYY MM DD HHHH:SS 99999.99999 999999.99
GENERAL EDITS
~ WELL INFORMATION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC
UWI . [CHAR 20] UNIQUE WELL ID UWI must be valid and exist on AER database. Unique Well Identifier - Bottomhole location.
DRILLEG. [NUMB 2] DRILLING LEG Must be 01, 02, 03…09 (Cannot be 0 or NULL) Drilling Leg (Event or Occurrence). Together with the UWI, this is to
help define the bottom of the specific drill hole.
WLIC. [CHAR 9] AER WELL LICENSE NUMBER Well License Number must match AER License AER Well License Number
Number for UWI
FORM. [CHAR 20] FORMATION NAME Name of the geological formation/zone
WSFL. [NUMB 2] WELL FLUID TYPE AT TEST DATE Must have a valid AER fluid code = (01) Oil, (02) Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
Gas, (06) Water, or (17) Crude Bitumen
WTYP. [CHAR 1] WELL TYPE INDICATOR Must be (V)ertical, (D)eviated or (H)orizontal Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore
PACKER. [CHAR 1] PACKER INDICATOR FLAG Must be either (Y)es or (N)o. Flag indicating presence of packer (Y)es, (N)o
TULD. [CHAR 1] TUBING IN WELL Must be either (Y)es or (N)o. Flag indicating Tubing in well (Y) or (N)
AFLO. [CHAR 1] FLOW PATH Must be either (A)nnular, (C)asing, (T)ubing, or Flag indicating flow path (A)nnular, (C)asing, (T)ubing, or (B)oth
(B)oth - casing and tubing. casing and tubing
TUBS.MM [NUMB 4,1] INSIDE DIAMETER OF PRODUCTION Mandatory, if [TULD] (Tubing in Well) = (Y)es and Inside diameter of production tubing
TUBING [AFLO] (Flow Path) = (T)ubing or (B)oth.
If present must be < [PTOD] (Outside Diameter of
Production Tubing)
PCID.MM [NUMB 4,1] INSIDE DIAMETER OF PRODUCTION Mandatory, if [AFLO] (Flow Path) = (A)nnular, Inside diameter of production casing
CASING (C)asing or (B)oth.
If present must be > 0.00 and < 350
PTOD.MM [NUMB 4,1] OUTSIDE DIAMETER PRODUCTION Mandatory, if [TULD] (Tubing in Well) = (Y)es and Outside diameter of production tubing
TUBING [AFLO] (Flow Path) = (A)nnular or (B)oth/casing
and tubing. If present must be < [PCID] (Inside
Diameter of Production Casing)
TTOPL.M [NUMB 6,2] TEST/PROD INTERVAL TOP M KB (LOG) [TTOPL] (Interval Top - Log) must be > 0.0 and < Top of tested or producing interval - in log depth, measured mKB
[TBASL] (Interval Base - Log)
TBASL.M [NUMB 6,2] TEST/PROD INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and Base of tested or producing interval - in log depth, measured mKB
=> [TTOPL] (Interval Top - Log) and cannot be
greater than Total Well Depth.
TTOPT.M [NUMB 6,2] TEST/PROD INTERVAL TOP M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Top of tested or producing interval - in true vertical depth,
(H)orizontal, then [TTOPT] (Interval Top - TVD) calculated mKB
must be < [TTOPL] (Interval Top - Log),
else if [WTYP] = (V)ertical, then [TTOPT] must =
[TTOPL]
TBAST.M [NUMB 6,2] TEST/PROD INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Base of tested or producing interval in true vertical depth,
(H)orizontal, then [TBAST] (Interval Base - TVD) calculated mKB
must be < [TBASL] (Interval Base - Log),
else if [WTYP] = (V)ertical, then [TBAST] must =
[TBASL]
FTDT.DAY/HR [YYYY MM DD HHHH] FINAL TEST DATE/TIME Must be >= Spud Date and <= Abandoned Date Date/time test ended
and <= Submission Date
TUPS.KPAA [NUMB 8,2] INITIAL TUBING PRESSURE Mandatory, if [AFLO] (Flow Path) = (T)ubing or Initial Tubing Pressure (kPaa): For Build-Ups tests, the pressure at
(B)oth and [PRSTY] (Pressure Test Type) <> (34), end of flow (prior to shut-in). For Drawdown tests, the static
else can be Null. pressure prior to flow
CSPS.KPAA [NUMB 8,2] INITIAL CASING PRESSURE Mandatory, if [AFLO] (Flow Path) = (A)nnular, Initial Casing Pressure (kPaa): For Build-Ups tests, the pressure at
(C)asing or (B)oth and [PRSTY] (Pressure Test end of flow (prior to shut-in). For Drawdown tests, the static
Type) <> (34), else can Null. pressure prior to flow
FCSPS.KPAA [NUMB 8,2] FINAL CASING PRESSURE Mandatory, if [AFLO] (Flow Path) = (A)nnular, Final Casing Pressure (kPaa): For Build-Ups tests, the pressure at
(C)asing or (B)oth and [PRSTY] (Pressure Test end of the shut-in period. For Drawdown tests, the final pressure at
Type) <> (34), else can Null. end of drawdown period
PFWH.KPAA [NUMB 8,2] FINAL FLOWING/INJECTION WELLHEAD Optional. Measured Final Flowing / injection pressure at the wellhead kPaa
PRESSURE
TSUR.DEGC [NUMB 5,2] SURFACE TEMPERATURE DEGC Mandatory, if ALL [SURBTM] (Gauge Location) Temperature measured at wellhead during operations
gauges = (S)urface.
SGPTAU. [CHAR 7] SINGLE-POINT AUTHORIZATION Mandatory, if [AOFTY] (AOF Type) < > 02 or 32 Authorization Number indicating AER Approval to conduct a Single-
and ( [AOFEXT] (Extended Sandface AOF) or Point AOF with potential expected to exceed 300 103m3/d.
[AOFSF] (Stabilized Sanface AOF) > = 300.
AIN. [CHAR 1] INLINE AOF INDICATOR FLAG Mandatory, if [AOFTY] (AOF Type) is Present. Well must be tied into pipeline during operations. PRD.PAS
Must be (Y)es or (N)o. If AER records indicate required if Production Tester on site.
"well on production" then [FTDT] (Final Test
Date/Time) must >= On Production Date (OPD),
else error.
LIT. [CHAR 1] LIT ANALYSIS INDICATOR FLAG Mandatory, if [AOFTY] (AOF Type) is Present. Flag indicating LIT (Lamiinar-Inertial-Turbulent) Flow Analysis (Y)es
Must be (Y)es or (N)o. or (N)o
QGLM.E3M3/D [NUMB 13,4] LAST MEASURED GAS RATE Mandatory, if [AOFTY] (AOF Type) is Present. (103m3/d). Last Measured or Extended Flowrate
QGST.E3M3/D [NUMB 13,4] STABILIZED GAS RATE Mandatory, if [AOFTY] (AOF Type) is Present. Calc Stabilized flow rate at Final Test conditions as per Regulatory
Requirements (103m3/d)
AOFEXT.E3M3/D [NUMB 13,4] EXTENDED SANDFACE AOF Mandatory, if [AOFTY] (AOF Type) <> 31, else Extended Transient Sandface AOF potential (103m3/d)
must be null.
AOFSF.E3M3/D [NUMB 13,4] STABILIZED SANDFACE AOF Mandatory, if [AOFTY] (AOF Type) <> (31), else Stabilized Sandface AOF Potential (103m3/d)
Null.
NWH. [NUMB 3,2] INVERSE SLOPE AT WELLHEAD Mandatory, if [AOFTY] (AOF Type) = (31); If [LIT] Wellhead inverse slope - "n" (should be 0.5-1.0).
(LIT Analysis Indicator Flag) = (Y)es can be null. If
[AOFTY] (AOF Type) = 02 or 32 then [NSF] must
be => 0.5 and <= 1.0 or if [AOFTY] = 01 then
[NWH] must = 1.0. Must be submitted if
Calculated.
AOFWEX.E3M3/D [NUMB 13,4] EXTENDED WELLHEAD AOF Mandatory, if [AOFTY] (AOF Type) = 31. Extended Transient Wellhead AOF potential (103m3/d)
If [AOFTY] <> 31 then can be null.
AOFWH.E3M3/D [NUMB 13,4] STABILIZED WELLHEAD AOF Mandatory, if [AOFTY] (AOF Type) = 31. Stabilized Wellhead AOF potential (103m3/d)
If [AOFTY] <> 31 then can be null.
QOLM.M3/D [NUMB 13,4] LAST MEASURED OIL RATE Mandatory, if [AOFTY] (AOF Type) = 41 then field (103m3/d)
must be present.
QOST.M3/D [NUMB 13,4] STABILIZED OIL RATE Mandatory, if [AOFTY] (AOF Type) = 41 Calc Stabilized flow rate @ Final Test conditions / Guide 40 (m3/d)
IPRST.M3/D [NUMB 13,4] STABILIZED OIL IPR Mandatory, if [AOFTY] (AOF Type) = 41 Stabilized inflow performance rate for oil well (m3/d)
IPRMAX.M3/D [NUMB 13,4] MAXIMUM OIL IPR (M3/D) Mandatory, if [AOFTY] (AOF Type) = 41 Maximum inflow performance rate for oil well
PFSF.KPAA [NUMB 8,2] STABILIZED FLOWING SANDFACE Mandatory, if [AOFTY] (AOF Type) is present, else (kPaa)
PRESSURE if [AOFTY] = 31 then it can be null. Ffield must be
present
LMPFSF.KPAA [NUMB 8,2] LAST MEASURED FLOWING SANDFACE If [AOFTY] (AOF Type) = 31 then it can be null (kPaa)
PRESSURE else mandatory
PFWH.KPAA [NUMB 8,2] STABILIZED FLOWING WELLHEAD Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa)
PRESSURE > 0.00. If [AOFTY] <> 31, can be null.
WPRE.KPAA [NUMB 8,2] STATIC WELLHEAD PRESSURE Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa)
> 0.00. If [AOFTY] <> 31, can be null.
LMPFWH.KPAA [NUMB 8,2] LAST MEASURED FLOWING WELLHEAD Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa)
PRESSURE > 0.00. If [AOFTY] <> 31, can be null.
PAVG.KPAA [NUMB 8,2] AVERAGE RESERVOIR PRESSURE AT Mandatory, if [AOFTY] (AOF Type) is present, else (kPaa)
MPP if [AOFTY] = 31 then it can be null.
AOFC. [CHAR 240] AOF COMMENT Optional Freeform comment of AOF/Deliverability quality. Data updates AER
Pressure Summary Database.
QGAS.E3M3/D [NUMB 13,4] GAS PRODUCTION RATE Mandatory, if [WSFL] (Well Fluid Type) = (02) and Gas rate during each Rate (RTNUM) Period (103m3/d).
[PRSTY] (Pressure Test Type) < > = (11), THEN
at least 1 line must be >0.00; If PRSTY = 50 AND
INJFL = 02 (gas), then cannot be zero and must
enter at least 2 DTSUM lines
QCON.M3/D [NUMB 13,4] CONDENSATE PRODUCTION RATE Can be Blank or Zero Condensate rate during each Rate (RTNUM) Period (m3/d).
CONGR.M3/E-3M3 [NUMB 5,4] CONDENSATE TO GAS RATIO Mandatory, if [QCON] (Condensate Production (m3/10-3m3)
Rate) > 0.0
GEQV.E3M3/D [NUMB 13,4] GAS EQUIVALENT OF CONDENSATE Mandatory, if [QCON] (Condensate Production (103m3/d)
Rate) > 0.0
QRGAS.E3M3/D [NUMB 13,4] RECOMBINED GAS PRODUCTION RATE Mandatory, if [QCON] (Condensate Production (103m3/d)
Rate) > 0.0
QWTR.M3/D [NUMB 13,4] WATER PRODUCTION RATE Mandatory, can be zero; If PRSTY = 50 and Water rate during each Rate (RTNUM) Period (m3/d).
INJFL = 06 (water), then cannot be zero and must
enter at least 2 DTSUM lines
TISI.DAY/HR [YYYY MM DD HHHH] TIME/DATE WELL SHUT-IN Must be > = spud date and < [FTDT] (Final Test Date/time well shut-in for final BU/FO
Date and Time) and the Submission Date
GSERU. [CHAR 20] GAUGE SERIAL NUMBER USED IN Must be found in 1 raw data table Serial number of gauge used to represent reservoir
SUMMARY
REPMPP.KPAA [NUMB 8,2] REPRESENTATIVE PRESSURE AT MPP IF [INTRP] (Test Interpretation Present) = (Y)es Representative pressure from Gauge or Run/Stop Depth OR
and ([PEXTR] (Representative Extrap/False Acoustic Calculation converted or adjusted to MPP.
Pressure) = [REPMPP] (Representative Pressure (Not for P* or Pr). See [PEXTR] and [PAVG].
at MPP)) or ([PAVG] (Representative Avg
Reservoir Pressure) = [REPMPP]), THEN
the Transient Pressure can not build or fall by
more than 2 kPa/hr (over last 6 hours of shut-in),
else error.
Note: Above calculations performed, IF Test Types
[PRSTY] = 04, 06 or 14 by way of [LMP] vs. ~DTG
(n) [PRGA], OR IF Test Types [PRSTY] = 11 or 12
by way of [LMP] vs. ~DTAC [PSUR].
PRCOR.KPA [NUMB 8,2] PRESSURE CORRECTION Mandatory, can be zero, Else If [GSERU] (Gauge Report Pressure Differential (value) used to adjust measured
Serial Number Used In Summary) matches a pressure from Run Depth or Final Surface pressure to MPP.
Representative Gauge (~DTG n) [GSER] (Gauge Negative values if gauge ran below MPP
Serial Number), where [SURBTM] (Gauge
Location) = (S)urface, then [PRCOR] must be >
0.00
GRPEXTR.KPA/M [NUMB 5,3] REPRESENTATIVE EXTRAP/FALSE Mandatory, if [PRSTY] = 50 AND [INTRP] (Test Reservoir pressure gradient (kPa/m).
PRESSURE GRADIENT (TVD) Interpretation Present) = (Y)es; must be > zero
PAVG.KPAA [NUMB 8,2] REPRESENTATIVE AVG RESERVOIR Optional. Best estimate of reservoir pressure kPaa at MPP
PRESSURE AT THE WELL If present and [PRSTY] (Pressure Test Type) =
(04), (11), or (14), then [PAVG] must be >=
[REPMPP] (Representative pressure at MPP), if
[PRSTY] = (06), (12) or (50) then [PAVG] must be
<= [REPMPP]
QRATE.M3/D or E3M3/D [NUMB 13,4] FINAL RATE PRIOR TO SHUT-IN Mandatory, if [INTRP] (Test Interpretation Present) Production or Injection prior to build-up or falloff. If Gas, report rate
= (Y)es, or [PRSTY] (Pressure Test Type) = (06), as E3M3/D, else if Oil or Water, report as (m3/d.)
(14), or (24), else can be null. Can be negative if
[PRSTY] = (06, 12 or 50),
If present and [WSFL] (Well Fluid Type) = (02),
then [QRATE] must be reported as (E3M3/D), else
(M3/D).
SKIN. [NUMB 5,2] CALCULATED SKIN FACTOR Mandatory, if [INTRP] (Test Interpretation Present) Apparent WELLBORE Skin Factor
= (Y)es; can be negative
KH.MDM [NUMB 13,7] CALCULATED FLOW CAPACITY Mandatory, if [INTRP] (Test Interpretation Present) Flow capacity (e.g. use limiting KH.mD·M on composite model).
= (Y)es; must be > zero millidarcy-m
PRISIP.KPAA [NUMB 8,2] DFIT INSTANTANEOUS SHUT-IN Mandatory, if [PRSTY] = (50) AND [INTRP] (Test For DFIT only
PRESSURE, BOTTOM HOLE Interpretation Present) = (Y)es; must be > zero
GRISIP.KPA/M [NUMB 5,3] ISIP GRADIENT (TVD) Mandatory, if [PRSTY] = (50) AND [INTRP] (Test For DFIT only
Interpretation Present) = (Y)es; must be > zero
PRCL.KPAA [NUMB 8,2] CLOSURE PRESSURE, BOTTOM HOLE Optional, if [PRSTY] = (50) AND [INTRP] (Test For DFIT only
Interpretation Present) = (Y)es; must be > zero
GRCL.KPA/M [NUMB 5,3] CLOSURE GRADIENT (TVD) Optional, if [PRSTY] = (50) AND [INTRP] (Test For DFIT only
Interpretation Present) = (Y)es; must be > zero
INJFL [NUMB 2] INJECTED FLUID Mandatory, if [PRSTY] = (50) AND [INTRP] (Test For DFIT only
Interpretation Present) = (Y)es;
Must have a valid AER fluid code = (01) Oil, (02)
Gas, (06) Water; must be > zero
QDFIT.M3/MINUTE [NUMB 6,4] FINAL INJECTION RATE (DFIT only) Mandatory, if [PRSTY] = (50) AND [INTRP] (Test For DFIT only
VTDFIT.M3 [NUMB 7,4] TOTAL VOLUME INJECTED FOR DFIT Interpretation
Mandatory, Present) == (50)
if [PRSTY] (Y)es; cannot
AND be zero
[INTRP] (Test For DFIT only
Interpretation Present) = (Y)es; cannot be zero
EFF.FRAC [NUMB 4,3] FLUID EFFICIENCY Optional, if [PRSTY] = (50) For DFIT only
TFLC.M/MIN1/2 [NUMB 9,8] TOTAL FLUID LOSS COEFFICIENT Optional, if [PRSTY] = (50) For DFIT only
RFLC.M/MIN1/2 [NUMB 9,8] RESERVOIR FLUID LOSS COEFFICIENT Optional, if [PRSTY] = (50) For DFIT only
Loc.m (MD) [NUMB 7,2] DEPTH OF TEST INTERVAL (m-MD) Mandatory, if [PRSTY] = (50) ; must be > zero For DFIT only; measured depth of the stage where the DFIT was
conducted.
Clusters [NUMB 3] Number of Clusters for DFIT Optional For DFIT only
Compl [CHAR 250] Type of Completion Optional Freeform comment for Type of Completion
PVT [CHAR 1] PVT Study Optional, Must be either (Y)es or (N)o. If Yes, then attach a PDF of PVT Study to the TRG Pas file.
PRGC. [CHAR 240] COMMENT ON PRESSURE Optional Freeform comment of Pressure - comparison to trend, offsets, shut-
in time etc. Data updates AER Pressure Summary Database.
PORO.FRAC [NUMB 4,3] ASSUMED POROSITY FRACTION Porosity of reservoir used in analysis
SATW.FRAC [NUMB 3,2] ASSUMED WATER SATURATION can be zero, sum of [SATW] (Assumed Water Water saturation assumed for this analysis
FRACTION Saturation) + [SATG] (Assumed Gas Saturation) +
[SATO] (Assumed Oil Saturation) must = 1
SATG.FRAC [NUMB 3,2] ASSUMED GAS SATURATION FRACTION can be zero Gas saturation assumed for this analysis
SATO.FRAC [NUMB 3,2] ASSUMED OIL SATURATION FRACTION can be zero Oil saturation assumed for this analysis SATO+SATG+SATW=1
HZFL.M [NUMB 10,5] HORIZONTAL WELL LENGTH IN Mandatory, if [WTYP] (Well Type) = (H)orizontal). Must be >0, if WTYP is horizontal
FORMATION If [WTYP] = (V)ertical, must be Null, else Optional.
RDOIL. [NUMB 4,3] OIL RELATIVE DENSITY If [WSFL] (Well Fluid Type) = 02 may be null, else Oil density relative to water (unit-less)
must be > 0 and <1
RDGAS. [NUMB 4,3] GAS RELATIVE DENSITY Mandatory, if [WSFL] (Well Fluid Type) = 02, must Gas density relative to air (unit-less); Recombined
be > 0 and < 1
RDWTR. [NUMB 4,3] WATER RELATIVE DENSITY Must be >= 1 Water density relative to water (unit-less) (>1.0)
PBP.KPAA [NUMB 8,2] OIL BUBBLE POINT PRESSURE If [WSFL] (Well Fluid Type) not = 01, [PBP] (Oil Bubble point pressure of oil (kPaa)
Bubble Point Pressure) can be null else mandatory
BO.RM3/M3 [NUMB 4,2] OIL FORMATION VOLUME FACTOR Oil Formation Volume Factor must be given if Oil shrinkage factor from surface to reservoir conditions
[WSFL] (Well Fluid Type) = (01) Oil.
RS.M3/M3 [NUMB 7,2] OIL SOLUTION GOR Mandatory, if [WSFL] (Well Fluid Type) = 01 (Oil); Solution gas oil ratio
else can be null
PPLV.M [NUMB 10,5] PUMPING LIQUID LEVEL M CF (TVD) AT Optional. If present, must be < Total Depth of well. Liquid level (or Calculated Length of Gas Column) prior to shut-in
TIME = ZERO (at time = zero). As determined by wireline or interpreted by an
Acoustic - - in TVD depth, measured mCF. For dry gas wells, Liquid
METHC. [CHAR 240] METHOD OF ACOUSTIC/DEAD WEIGHT Mandatory, if [PRSTY] (Pressure Test Type) = 11 Description pertaining
Level (or Length of GastoColumn)
the method
is toofbeAcoustic
reported/ DWT
equalcalculation,
to MPP or
TESTER EXTRAPOLATION COMMENT or 12 in accordance
Null. A depth ofwith
zeroAER
will Guide 3 and Guide
be interpreted 5. to Surface".
as "Liquid
GSER. [CHAR 20] GAUGE SERIAL NUMBER One Gauge must match [GSERU] (Gauge Serial Serial or Reference number of Gauge/Recorder.
Number Used in Summary) Note: Number required for the ability to audit gauge data.
GTYPMM. [CHAR 90] GAUGE TYPE / MANUFACTURER / MODEL Gauge Type, Manufacturer and Model must be Type (mechanical, electronic, model), manufacturer, and model, of
separated with slashes. gauge used, for source data
GRNG.KPAA [NUMB 8,2] MAXIMUM RECORDER RANGE Full scale pressure range of source gauge (kPaa)
GCAL.DAY [YYYY MM DD] DATE OF LAST CALIBRATION Must be < = [FTDT] (Final Test Date/Time) Date source gauge last calibrated
GRES. [NUMB 6,5] RESOLUTION % OF FULL-SCALE Published resolution of source gauge
GACC. [NUMB 6,5] ACCURACY % OF FULL-SCALE Published accuracy of source gauge
RDGAL.M [NUMB 10,5] GAUGE RUN DEPTH M CF (LOG) If [SURBTM] (Gauge Location) = (S)urface, then Source gauge final stop depth, (Measured Depth/LOG) in mCF
[RDGAL] must = 0
GONB.DAY/HR/SS [YYYY MM DD HHHH:SS] DATE/TIME GAUGE ON BOTTOM OR Must be > Spud Date and < then [GOFB] (Gauge Date/time source gauge on bottom
SURFACE RECORDINGS BEGIN Off Bottom or Surface Recordings Cease)
GOFB.DAY/HR/SS [YYYY MM DD HHHH:SS] DATE/TIME GAUGE OFF BOTTOM OR Must be > [GONB] (Gauge On Bottom or Surface Date/time source gauge off bottom
SURFACE RECORDINGS CEASE Recordings Begin and <= [FTDT] (Final Test
Date/Time)
~ DTG (n)
TIME TCUM PRGA TGA GCOM
YYYY MM DD HHHH:SS 99999.99999 999999.99 999.99 X (240)
YYYY MM DD HHHH:SS 99999.99999 999999.99 999.99 X (240)
YYYY MM DD HHHH:SS 99999.99999 999999.99 999.99 X (240)
ETIME.HR [NUMB 10,5] ELAPSED TIME Can be zero Elapsed time from start of test
LLVL.M [NUMB 10,5] LIQUID LEVEL M CF (LOG) Mandatory if [PRSTY] (Pressure Test Type) = 11 Calculated Length of Gas Column, as determined by wireline or
or 12, can be zero. If [PRPS] (Test Purpose interpreted by an Acoustic Shot - in LOG/measured depth (mCF).
Indicator) < > (I)inital, THEN at least 1 occurrence Note: For dry gas wells, Liquid Level (or Length of Gas Column) is
of [LLVL] must exist in table. to be reported equal to MPP or Null. A depth of zero will be
(note: zero = Fluid to Surface) interpreted as "Liquid to Surface".
LLVT.M [NUMB 10,5] LIQUID LEVEL M CF (TVD) Mandatory, if [WTYP] (Well Type) = (D)eviated or Calculated Length of Gas Column (or liquid level) for each shot
(H)orizontal. If [WTYP] = (V)ertical, then [LLVT] (TVD). As determined by wireline or interpreted by an Acoustic - in
can be null or = [LLVL] TVD depth, calculated mCF. Note: See [LLVL]
PSUR.KPAA [NUMB 8,2] SURFACE PRESSURE Mandatory, must be > 90 kPa Measured casing/surface pressure at corresponding point of time
(kPaa)
GRGAS.KPA/M [NUMB 5,3] GAS GRADIENT (TVD) Mandatory, if [LLVL] (Liquid Level - Log) > 0.0 or Estimated gradient of gas in wellbore
null. Then must appear at least once per table.
GROIL.KPA/M [NUMB 5,3] OIL GRADIENT (TVD) Mandatory, if [WSFL] (Well Fluid Type) = (01) or Estimated gradient of oil in wellbore
(17). Then must appear at least once per table
GRWTR.KPA/M [NUMB 5,3] WATER GRADIENT (TVD) Mandatory, if [QWTR] (water Production or Estimated gradient of water in wellbore
injection Rate) > 0.0. Then must appear at least
once per table
PMPPT.KPAA [NUMB 8,2] CALCULATED PRESSURE AT MPP (TVD) If ([FTDT] (Final Test Date/Time) - [TISI] Calculated using above parameters at corresponding point in time
(Date/Time Well Shut-In)) < 14 days) and [PRPS]
(Test Purpose Indicator) = (A)nnual or (I)nitial,
~DTAC GET [PMPPT] at the last real time in the table
THEN go back 6 hours and subtract the [PMPPT]
TIME ETIME LLVL
at that time) if value is <= 2.5 kPa/hr, OK, else
LLVT PSUR
error.
YYYY MM DD HHHH:SS 99999.99999 99999.99999 99999.99999 999999.99
YYYY MM DD HHHH:SS 99999.99999 99999.99999 99999.99999 999999.99
YYYY MM DD HHHH:SS 99999.99999 99999.99999 99999.99999 999999.99
~ DTINRPR
PRGA ITIME QGAS QOIL QWTR
999999.99 99999.99999 999999999.9999 999999999.9999 999999999.9999
999999.99 99999.99999 999999999.9999 999999999.9999 999999999.9999
999999.99 99999.99999 999999999.9999 999999999.9999 999999999.9999
PRSTY AOFTY
04 Bottom Hole - Build-Up (BU Only) 01 Single-Point (AOF)
05 Bottom Hole - Segregation 02 Multi-Point (AOF)
06 Bottom Hole - Fall-Off 31 AOF - Wellhead Only (not calculated to Bottomhole conditions)
11 AWS - Build-Up (Transient) 32 AOF - Theoretical Multi-Point
12 AWS - Fall-Off (Transient) 41 IPR - (Oil Well Only)
14 Flow and Build-Up
15 Bottom Hole - Interference
24 Drawdown (only)
34 Sentry (Permanent Downhole Recorder/Pziometer)
50 DFIT (Diagnostic Fracture Injection Test)
GENERAL EDITS