53-002 ENG Brochure SBC DLS-DALI
53-002 ENG Brochure SBC DLS-DALI
53-002 ENG Brochure SBC DLS-DALI
DALI LIGHTING
SYSTEMS
Lighting Controls
MAKING LIGHT WORK Making light work of Designed to DALI2 MAKING LIGHT WORK
installation and commissioning Standard
OF DALI ADDRESSABILITY OF DALI DLS
Lighting Control System in a sensor
• • DALI2 brings an additional 64
Ex-Or has been creating award winning lighting control makes DLS simple and quick to install – ideal device addresses to the system Power – the built in Power Supply Unit (PSU)
systems since 1984. Our unrivaled expertise has delivered for exposed soffits where mounting a large provides power to the DALI network, which
• Backwards compatibility with
some of the industry’s most innovative solutions. DALI Lighting controller is unsightly
older DALI systems
is enough for the luminaires, sensors and
Systems (DLS) has been developed to simplify the installation, No additional controller hardware reduces
• switches.
commissioning and maintenance of DALI addressable lighting. hardware cost and saves time on installation
DLS covering single - and Multi- room systems to fully DALI Addressable simple wiring (just 5
•
integrated DALI lighting and BEMS integration.Ex-Or has core cable) Reduce wiring errors. Less time
planning wiring lay out and simple installation DLS COMPARISON
redefined DALI addressability.
Soft wiring – Easily make changes to lighting
• FUNCTION DALI64SYLKPSU DALI64SYLK DALI64 DALINET
without physically re-wiring makes DLS ideal
for multiuse spaces easily reconfigure working
Making light work for spaces 5 core cable for 230V 2 core DALI and 2 core
Wiring 2 core DALI 2 core DALI
comfort and productivity Easy wireless and batteryless switches
•
and DALI 2 core for Sylk for Sylk
Honeywell Honeywell
2 DALI Lighting Systems DALI Lighting Systems 3
DALI64 DALI64SYLKPSUF
Sensor DALINETF Sensor
DALI64 is a fully featured standalone DALI lighting
control system embedded into a state of the
art LightSpot HD sensor with an advanced lens
DALI Scene Plate
design which provides a wide detection diameter
of 10 metres and with 159 points of detection an
excellent dependable level of occupancy detection
is achieved.
SYSTEM OVERVIEW
INTEGRATED ROOM CONTROL TOGETHER WITH
PCD7.LRXX-P5
Recommendations:
Honeywell Honeywell
4 DALI Lighting Systems DALI Lighting Systems 5
DALI64 SYLK SYSTEM ARCHITECTURE
The DALI64SYLKPSU can be seamlessly integrate
to SBC BEMS system and Saia PCD Supervisor
with a simple polarity independent 2 wire Wallbus
connection. Saia PCD Supervisor
It allows the control of HVAC and lighting through a common interface.
Honeywell Honeywell
6 DALI Lighting Systems DALI Lighting Systems 7
SYSTEM CONTROL ADVANTAGES FACILITY COST SAVINGS
Improving Employee productivity and Create real time energy management and maintenance reports
wellbeing or help patients heal faster or •
Visualisation of energy usage
enhance student learning by utilising
network time schedules to control •
Luminaire run-time – create preventative maintenance reports
luminaire colour temperature to match •
Arc power consumption of luminaires
natural circadian rhythm to create
human centric lighting which influence •
Desired/actual lux levels
various physiological and psychological
processes. This enable benefits in Monitor occupancy data to create room usage reports
different verticals like Offices, Schools, •
Occupancy data – hours
Healtcare, Hospitality, Retail and
Manufacturing. Staff optimization
•
Create cleaning rotas based on occupancy - saving time and money
• Select and control lighting scenes
through Saia PCD Supervisor Building space optimization
• Utilise the supervisor to manage light •
Reporting frequency of space use to maximise room occupancy and
levels, time delays and even change booking
between Absence and Presence mode
• Recall groups and scenes from the head Emergency Test and Reporting
end
• Visualise the status of emergency lighting fittings
• Schedule all of the legally required emergency fitting tests, visualise the
results in the Supervisor and email a test report or alarms
ENGERGY COSTS
SAVING
Combining BEMS/HVAC
and Lighting Controls will
significantly improve the
energy performance of
the building. Integrating
lighting and HVAC control VISUALISATION
together into BEMS For example empirical data can • Visualise lighting and BEMS through
Saia PCD Supervisor
contributes to reaching be used to predict optimum start
Class A energy efficiency and stop times based on historical • Real time occupancy status of
EN15232. occupancy data. building zones
• Current luminaire status, including
lamp failure, in each building zone
Honeywell Honeywell
8 DALI Lighting Systems DALI Lighting Systems 9
DALI64 DALI64
MAKING LIGHT WORK
COLOUR-CODED CONNECTORS
Intuitive programming
Light Touch allows you to connect to the DALI system
over Bluetooth and begin a bus scan. Any luminaire BLUETOOTH® LOW ENERGY SWITCHES DALI 6 BUTTON SCENE PLATES
or DALI device is visually presented in a carousel and
can be dragged and dropped with a simple one finger
Luminaires can be switched on and off, dimmed
action into a user defined map of the space. Once you
and grouped via the touchplate with six individually
have all your lights and devices positioned on your
assignable keys.
building map you can then set up groups and scenes
with minimum fuss. • Capacitive touch – requires less pressure to operate and
Daylight harvesting offers additional energy savings increased durability as there are no moving parts
by automatically regulating the luminaries as the • High-quality appearance with real glass display – easy to clean
ambient light levels change throughout the day. • Power supply via DALI line
Colour temperature can also be configured allowing
• Wireless – instant installation and location flexibility,
circadian rhythms – optimising occupant wellbeing reducing disruption and cost, as there is no need to run
and productivity. switching cables
• Self‑powered innovative patented technology to ‘harvest’
energy means zero maintenance as there are no batteries
to change
• Ultimate flexibility as each switch can control up to 64
luminaires, enabling dimming and scene recall etc DALI SWITCH INPUT MODULE
• Energy savings with additional local control, alongside
the network sensors, users can create an energy efficient DALI switch input modules can
environment be added to convert normal
• Bluetooth® wireless switches - energy harvesting single ‘push-to-make’ switches
and double rocker switches eliminate the need for wiring to DALI switches.
and speed installation time significantly
• Wireless switches can be fixed to surfaces using screws
Scan to discovers On-screen prompts lead you or double sided mounting film
luminaires through configuration
Honeywell Honeywell
10 DALI Lighting Systems DALI Lighting Systems 11
DALI LIGHTING CONTROLS
PRODUCT RANGE
DALI LIGHTING CONTROLLERS WITH BMS CONNECTION AND INTERGRATED POWER SUPPLY ACCESSORIES
PRODUCT NUMBER DESCRIPTION POWER PRODUCT NUMBER DESCRIPTION POWER
DALI2 64 Address Lighting Controller with 150mA Integral Power
DALI64SYLKPSUF Mains
Supply and Sylk Bus for direct BMS connection - Flush Mount 28001987 6 button Scene Plate – On/Off – Up/Down + 3 Scenes 10mA
DALI2 64 Address Lighting Controller with 150mA Integral Power
DALI64SYLKPSUS Mains
Supply and Sylk Bus for direct BMS connection - Surface Mount
28001989 6 button Scene Plate – On/Off + 6 Scenes 10mA
DALI64F DALI2 64 Address Lighting Controller Bus Powered - Flush Mount 12mA
Remote Infrared Hand-held unit c/w Wall Bracket -
QCUB light level adjustment for 1 group and recall six lighting N/A
DALI2 64 Address Lighting Controller Bus Powered - scenes to change
DALI64S 12mA
Surface Mount
Light Touch
Free commissioning App optimised for 9” tablet N/A
by Honeywell
DALI NETWORK SENSORS FOR DETECTION-ZONE EXTENSION
PRODUCT NUMBER DESCRIPTION POWER
Honeywell Honeywell
12 DALI Lighting Systems DALI Lighting Systems 13
Saia-Burgess Controls AG
Bahnhofstrasse 18 3280 Murten, Switzerland
Telephone headquarters +41 26 580 30 00
Telephone SBC Support +41 26 580 31 00
Fax +41 26 580 34 99