Control Model NICE 3000 Plus
Control VVVF- 32 Bit Microprocessor control system variable
Operation voltage variable frequency.
Control Speed 1m/s or 60meter per minute
Control power For 8 persons 7.5 kW
Control inverter Monarch manufacture by Monarch Innovation Tec
Control Main NICE 3000 Plus manufacture by NICE 3000 Plus
Board German Monarch Innovation Tec
Control German Technology
Technology
MOTOR
Motor Type Gearless
Motor Operation VVVF- 32 Bit Microprocessor control system variable
voltage variable frequency.
Motor Speed 1m/s or 60meter per minute
Motor power For 8 persons 4.2 KW
Motor Brand MONADRIVE/BLUELIGHT GEARLESS manufacture
by MONA DRIVE/ BLUELIGHT Int
Motor Technology German Technology

CABIN
Cabin Size Wide 1400mm X Depth 1100mm for persons
Shaft Size Wide 1800mm X Depth 1800mm
Cabin wall Stainless steel mirror Etching 1.5mm thickness 304 grade
Cabin door Stainless steel mirror Etching 1.5mm thickness 304 grade
Cabin Calling Standard choice by customer
Cabin Handrail Standard choice by customer
Cabin Floor Standard choice by customer
DOOR
GF Door Stainless steel mirror Etching 1.2mm thickness 304 grade
Other floor Door Stainless steel Hairline 1.2mm thickness 304 grade
Door open 800/2100mm Two panel Center opening system
DOOR
FRAME
GF door Wide jam 300mm with transom panel
Stainless steel mirror Etching 1.2mm thickness 304 grade

DOOR
OPERATOR
Brand Mitsubishi Type, Japan Mitsubishi Technology
Type VVVF type two panel center opening system
32 Bit Microprocessor control system variable voltage
variable frequency.
DOOR
HEADER
Brand Mitsubishi Type, Japan Mitsubishi Technology
Type VVVF type two panel center opening system
32 Bit Microprocessor control system variable voltage
variable frequency.

GUIDERAIL
Main Guide Standard machined T-section Iron, 75 x 62 x 10mm.
Counter Standard machined T-section steel, 65 x 65 x 16mm.

Traveling Cable 24 Core cable


Wearing Cable 4 Core and 2 core double consoling system cable

SAFETY ITEM
Door Full Height Electronics Photocell
protection
Speed Speed Governor safety
Control
Break system Cabin Emergency Brake system
Phone Intercom system 3 way, (lobby, cabin, Machine
room)
Limit Switch Upper final limit, pre limit, slow limit,
Down final limit, pre limit, slow limit
light Emergency cabin light
AVR Automatic voltage regulation
ARD Automatic Rescue Device
Pit safety Main guide and counter guide buffer
Pit inspection switch
Control Fuse system
safety
Sound safety Alarm system
Door Cabin door contact system
Landing Door contact system
Special Specification

Rescue operation to the nearest landing


Door opening failure rescue operation to the nearest landing
Door safety return
Opening door waning
Overload weighing device (warning buzzer/voice guidance)
Each-floor-stop operation
Emergency Light with self-charging and discharging
LANDIC (emergency landing device)
Automatic re-leveling device
Multiple beams door sensor
Car door pocket sensor
VONIC (Voice guidance device for car)
Automatic door dwell time control
Anti-nuisance call cancellation (judging by timing)
Anti-nuisance call cancellation (judging by load)
Behind car call cancellation
Car Call cancellation (cancellation by twice pressing button)
Automatic car light off
Automatic car fan off
AVR
ARD
Standard function
1 Full collective selective control An automatic traveling control mode by analyzing signals from
every landing, car and other special signals.
2 Attendant travel Auto-directional attendant-directional non auto-close door (attendant should
push closed button for inching close, when door doesn't close fully, release the button and door
auto-open), bypass.
3 Independent travel All hall call signals will be cancelled, elevators only respond to the car call.
4 Door auto-open when unlocking When unlocking, car door will be opened automatically if
elevator is at the door opening zone.
5 Motor jammed and overheat protection
When the system monitors whether the motor is jammed or overheated the elevator will be
stopped until the motor recovered to normal condition
6 Main circuit contactor protection Check if the contact in the main circuit contactor can work
normally car travel will be stopped if it is in abnormal conditions
7 Door auto-open when arrival Car door will be auto-opened when the elevator arrives at the
destination floor.
8 Fault self-diagnostic function The system can judge fault and record based on the collected
signals by its self-diagnostic system.
9
Hall call registration and memory display When Hall call button is pushed, the system will
switch on the button light for call accepted and registered. The elevator will start traveling.
10 Travel direction and floor scrolling message display Car operation panel and calling board have
dot-matrix display for floor and scrolling display for travel direction.
11 Full car bypass When full load, elevator doesn't respond to hall call signals from the passing
floor and only respond to the car call signals.
12 Program run WDT protection WDT detects continuously if the program runs wrongly all
output resetting system will be cut out when mistakes are found.
13 Power failure data holding All running data will be saved completely when power cut.
14 Learning function Use learning function of the system to check data of well (travel distance
correction switches location pre-limit switches location etc.) And save these data permanently
before the elevator starts traveling.
15 Fault history record The system can record 50 recent faults including floor code.
16 Emergency car lighting supply Emergency lighting supply in the car operation panel will turn
on automatically when power cut.
17 Speed monitoring The system will monitor travel speed of elevator all the time in order to
prevent from over-speed or abnormal speed etc.
18 Door holding time automatic In the mode of full automatic travel, the door will keep opening for
several seconds then close automatically when the elevator arrives at the floor. The time delay can be
set in the system.
19 Door open with floor button Car door will be opened automatically if the floor button is pushed.
20 Call reversal registration The call will be registered if call direction of this floor is reversal to travel
direction, otherwise the door will be opened.
21 Car light and ventilation fan shut off automatically If no call or call registration exceeds a period of
time (which can be set), car light and fan are automatically shut off. if call is received, light and fan are
on again.
22 Non-leveling zone automatic leveling When elevator is under the non-inspection state and doesn't
stop at the leveling zone, elevator will move to the leveling zone with slow speed as long as it meets
the safety requirements of starting.
23 Car overload indicator When car is overloaded, overload light on car operation panel is on and buzzer
sounds.
24 Lock service In the state of full automatic travel, if the lock switch is actuated, all call registered will
be eliminated, elevator will return to home landing, shut off the car light with door close
automatically and stop the elevator. The elevator will start to travel again after the lock switch is reset.
25 Full car bypass indicator Landing indicator shows it is in the state of bypass.
26 Terminal overstep protection Terminal protection switches are installed on both terminals; car will be
stopped traveling when system found the switches are actuated.
27 Door zone limit protection Car will be stopped traveling if system detects that hall door or car door
has been opened not in door opening zone.
28 Anti-stall protection The elevator will stop when hoist rope is slipping.
29 Door interlock safety protection Elevator would stop when system found the safety circuit of door
interlock break.
30 Safety door edge protection When safety door edge is actuated, re-open the door and it remains open
until it stops.
31 Terminal floor data correction System will automatically correct floor data when elevator arrives at
terminal landing floor.
32 Fault stop, self-rescue When elevator breaks down with emergency stop in non-opening zone The
elevator will creep to the nearest floor and open the door after leveling.
33 Intercom Push intercom button on the car operation panel, passengers in the car can communicate
with people in the machine room and supervise room lf the elevator
COMMERCIAL OFFER Including AVR&ARD

BRAND COMMODITY & SPECIFICATION QTY.

PASSENGER LIFT
Shipment : From China 01
LG Rise Capacity : 630kg (8 persons) 19, 50,000/= 19, 50,000/=
Floors :4 Set

TERMS AND CONDITIONS


Installation : 30 days after delivery of materials at project site without civil
work.
Validity of price : 30 days after quotation submit.
Training (local) : Free of cost to the concern persons of the owner.
After sales service : 12(Twelve) months Free service, our service Technical will
provide Preventative maintenance of the system. After
\ Commissioning of the lift.
Grantee : 12(Twelve) Months for any kind of manufacturing fault. After
Commissioning of the lift.

Spear parts : From the date of installation Available from the ready stock.
Material supply at your site: Within 75 days after contact signing
TERMS OF PAYMENT TURNKEY BASIES:

1st Installment 45% payment shall be paid from total contact money at the time of
contract signing.
2nd Installment 50% payment shall be paid from total contact money at the time
bank document receive
Final Installment 5% payment shall be paid to us with in 30(Thirty) days after
Testing& Commissioning trail operation of the, lift.

We hope that you will select the best quality and heavy-duty elevator for your project with
a most competitive price. If you have question about our offer, we are always to attend
your query.

You might also like