XT56-N / XT264 / XT364 Single Display, Multifunction Timers

Features :
! Single Set Point
! On delay / Interval
! 2 C/O DPDT
! 6 Time Ranges
! Down Counting

Certification :
48 x 48mm 72 x 72mm 96 x 96mm

Display Specifications Dimensions

Display 3 digits, 7 segment LED Panel Cutout


LED Indications Relay ON

D F
A
Input Specifications

Accuracy ±0.05% of F.S. or 50msec


B E C G
Start Input Pulse start

Models
DIM A B C D E F G
Output Specifications
XT56-N 48 48 100 45 7 46 46
Relay Contact 2 C/O DPDT
XT264 72 72 115 68 10 69 69
Contact Rating 5A @ 230V AC
XT364 96 96 70 90 10 92 92

Functional Specifications Terminal Connections


Modes ON delay / Interval XT56-N
Time Ranges 0 - 9.99sec
0 - 99.9sec
0 - 999sec
0 - 99.9min
0 - 999min
0 - 99.9hr
Resolution 0.01sec
Counting Direction Down
Set Point 1
Time Setting Pushwheel Cable Size (mm2): 1.5 ; Tightening Torque (N-m): 0.5

Reset Front, Remote, On power interruption


Memory Retention No XT264

Auxiliary Supply Specifications

Supply Voltage 90 to 270V AC / DC (50 / 60Hz)


24V AC/DC (Optional)

Environmental Specifications

Temperature Operating : 0 to 500C


XT364
Storage : -5 to 550C
Humidity (non - condensing) 95% RH

Mechanical Specifications

Mounting Panel Mount


Weight XT56-N - 170gms
XT264 - 325gms
XT364 - 350gms

www.selec.com 1
XT56-N / XT264 / XT364 Single Display, Multifunction Timers

TIMING DIAGRAMS Compliance

Function : ON delay Applicable EMI / EMC Standards


Supply Voltage
Product Standard
Category Reference Standards Testing Level
NO Contact Electrostatic Discharge IEC 61000-4-2 Level-3
NC Contact
T
Electrical Fast Transient / Brust IEC 61000-4-4 Level-3
T = set time
Electromagnetic Field IEC 61000-4-3 Level-3

Function : Interval
Surge IEC 61000-4-5 Level-3
Supply Voltage IEC 61000-4-6 Level-2
Conducted RF

Rated Power Frequency IEC 61000-4-8 Level-4


NO Contact Voltage Dip / Short Interruptions IEC 61000-4-11 Level-3
NC Contact
T
Conducted Emissions CISPR-11 Class-B
T = set time
Rated Emissions CISPR-22 Class-A

Emission & Immunity IEC 61326-1


Safety IEC 61010-1
PFMF (Passing criteria) IEC 61000-4-8 Class A

Ordering Information
Product Code Supply Voltage Certification

XT56-N 90 to 270V AC / DC

XT56N-24V 24V AC / DC

XT56-N-CE 90 to 270V AC / DC

XT264-3 90 to 270V AC / DC

XT364-3 90 to 270V AC / DC

www.selec.com 2