XT5042 Dual Display Multifunction Timer

Features :
7 Functions
!
9 Time Ranges
!
4 Digits, 7 segment LED Dual Display
!
LED Status Indications : Relay Status, Seconds, Minutes, Hours
!
Dual Set Point
!
Batch Function
!

Certifications : C US
E253771

48 x 48mm

Display Specifications Environmental Specifications

Digits 4 digits, 7 segment LED, dual display Temperature Operating : 0 to 50oC (32 to 122oF)
Storage : -20 to 75oC (-4 to 167oF)
LED Indicatons 1 : Relay1
2 : Relay2, Second, Minutes, Hours Humidity (non - condensing) 95% RH

Input Specifications Mechanical Specifications

Start Input Gate / Pulse start (programmable) Mounting Panel Mount


Accuracy ±0.05% of F.S. or 50msec (F.S. = Full Scale) Weight 175gms

Dimensions
Output Specifications

Relay Contact 2 C/O SPST XT5042


Contact Rating 5A @ 230V AC
48mm 46mm

Functional Specifications

45mm

46mm
48mm

Modes ON delay, Interval, Cyclic ON first, Cyclic OFF


first, Forward - Pause - Reverse,
Instantaneous + Delayed Batch 100mm
7mm
Time Ranges 0 - 99.99sec
0 - 999.9sec
0 - 9999sec
0 - 99:59min : sec,
0 - 999.9min
0 - 9999min Terminal Connections
0 - 99 : 59hr : min,
XT5042
0 - 999.9hr
0 - 9999hr
Resolution 0.01sec
Counting Direction Up / Down
Set Point 2
Time Setting By keys on front panel
Reset Front, Remote,
On Power interruption (programmable)
Memory Retention 10 years
Configuration Lock Password protected
Cable Size (AWG) : 13; Stud Hole for Lug (inch) : 0.137; Tightening Torque (Lb - inch) : 7

Cable Size (mm ) : 2.5; Stud Hole for Lug (mm) : 3.5; Tightening Torque (N - m) : 0.8
2

Auxiliary Supply Specifications

Supply Voltage 90 to 270V AC / DC (50 / 60Hz), 24V AC / DC


-15% to 10% tolerance
Power Consumption 5VAmax

www.selec.com 1
XT5042 Dual Display Multifunction Timer

TIMING DIAGRAMS

Function : ON Delay Function : Interval Function : Cyclic ON First


Supply Voltage Supply Voltage Supply Voltage

Start Start Start

Reset Reset Reset

Output NO Output NO Output NO


ON Delay NC ON Delay NC Cyclic ON NC
tStrt t tStrt t t1 t1 t1
tStrt t tStrt t tStrt t2 t2 tStrt t2

tStrt = start time; t = set time delay tStrt = start time; t = set time delay tStrt = start time; t1 = ON time; t2 = OFF time

Function : Cyclic OFF First Function : Motor Reverse Mode Function : Instantaneous + Delayed At Start Pulse
Supply Voltage Supply Voltage Supply Voltage
Start Start
Start
Reset Reset
Reset NO Instant NO
Relay 1 NC Contact NC
Output NO NO Delayed NO
Cyclic OFF NC Relay 2 NC Contact NC
t1 t1 t1
tStrt t2 t2 tStrt t2
t1 t2 t3 t2 tStrt t tStrt t

tStrt = start time; t1 = OFF time; t2 = ON time t1 = ON time of Relay1; t2 = Pause time; t3 = ON time of Relay2 tStrt = start time; t = set time delay
Function : Instantaneous + Delayed At Power ON
Supply Voltage Function : Batch
Start
Batch
Reset
Preset
Instant NO
Contact NC 0
Delayed NO
Contact NC Output
tStrt t tStrt t

tStrt = start time; t = set time delay

Compliance Ordering Information


Applicable EMI / EMC Standards
Product Code Supply Voltage Certification
Product Standard
Category Testing Level XT5042 90 to 270V AC / DC
Reference Standards
Electrostatic Discharge IEC 61000-4-2 Level-3 XT5042-CU 90 to 270V AC / DC C
E253771
US

Electrical Fast Transient / Brust IEC 61000-4-4 Level-3 XT5042-24V 24V DC

Electromagnetic Field IEC 61000-4-3 Level-3

Surge IEC 61000-4-5 Level-3

Conducted RF IEC 61000-4-6 Level-2

Rated Power Frequency IEC 61000-4-8 Level-4

Voltage Dip / Short Interruptions IEC 61000-4-11 Level-3

Conducted Emissions CISPR-11 Class-B


Rated Emissions CISPR-22 Class-A

Emission & Immunity IEC 61326-1


Safety IEC 61010-1
PFMF (Passing criteria) IEC 61000-4-8 Class A

www.selec.com 2