Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Marina Square: Design & Construction of Proposed Marina Square Mix Development

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MARINA SQUARE

B
PROJECT TITLE

DESIGN & CONSTRUCTION OF PROPOSED


MARINA SQUARE MIX DEVELOPMENT
250, SRIMATH RAMANATHAN MAWATHA,
COLOMBO-15,
SRI LANKA.
DEVELOPER & ENGINEER :

D
Harbour Village (Pvt) Ltd
No 278, Access Towers
Union Place,
Colombo 02.
PROJECT ARCHITECT :

The Design Group Five International (Pvt)Ltd,


3, Anderson Road,

D
200mmX75mm CABLE TRAY FOR ELE
75mmX75mm CABLE TRAY FOR ELV

Colombo 05,
Sri Lanka.

200
425Wx750Dx150H DRIVE OPENING @
SSL + 2500 FOR ELECTRICAL & ELV T +94 112 588844
C 00
Ø2 Ø50 Ø2
00
100
CABLE TRAY

Ø150 E mail@dgfivei.lk
www.dgfivei.lk
330 964 1630 312

DESIGN & BUILD CONTRACTOR:


1 Ø200mm DISCHARGE WATER PIPE TO PODIUM

200
2 Ø50mm INCOMING WATER PIPE
D

3600

3600

3600
B
CHINA HARBOUR
3
Ø200mm DISCHARGE WATER PIPE TO TOWERS ROOF

China Harbour Engineering CO LTD,


425WX750DX150H DRIVE OPENING FOR Level 32, East Tower,
ELECTRICAL & ELV CABLE TRAY World Trade Center, Echelon Square,
ELEVATION "C-C"
Colombo 01,SriLanka.
D

Ø150mm INCOMING WATER PIPE T +94112470998


4 www.chec.bj.cn

CONTRACTOR'S DESIGNER:

Surbana Jurong Consultants Pte. Ltd,


168 Jalan Bukit Merah,
A * THIS PUMP ROOM LAYOUT IS SHOWN PUMPS INSTALL A #01-01 Connection One,
LOCATION ARRANGEMENT AND PUDDLE FLANGE FOR C Singapore 150168
DOMESTIC WATER TANK LAYOUT PLAN
WATER TANK ONLY.
THE DETAIL PUMP ROOM ELEVATION, PIPE INSTALL LEVEL T +65 62481288
VALVES LOCATION ETC. PLEASE REFER TO DETAIL PUMP ROOM www.surbanajurong.com
DRAWING NO. P0102 WHICH WILL BE SUBMITTED LATER

ACS Integrated (Pvt) Ltd,


23/ 1/ 1, P.Ruban Peiris Mawatha,
Kalubowila,
Sri Lanka.
T +94 11 207 3359
E mail- info@acsintegrated.com

KEY PLAN

T05

2 3 4 5 N
T04

T01
T02 T03

LEGEND: (ELEVATION-"A-A")
REFERENCE DRAWINGS
A Ø 200 PUDDLE FLANGE FOR SUCTION PIPE DRAWING NO: DESCRIPTION REV. DATE
E I E
C I
C B Ø 150 PUDDLE FLANGE FOR INCOMING PIPE
B B
H H
G G C Ø 50 PUDDLE FLANGE FOR MODULATING TYPE FLOAT VALVE

D Ø 25 PUDDLE FLANGE FOR WATER LEVEL INDICATOR

E Ø 32 PUDDLE FLANGE FOR WATER LEVEL SENSOR CABLING

F Ø 100 PUDDLE FLANGE FOR BALANCING PIPE


1

F
A J J
F A
G Ø 25 PUDDLE FLANGE FOR WARNING PIPE
D D

H Ø 200 PUDDLE FLANGE FOR OVER FLOW PIPE

EFFECTIVE VOLUME:860.28m3
I Ø 100 PUDDLE FLANGE FOR VENT PIPE
1 Second Submission 10th AUG 2020
DOMESTIC WATER TANK ELEVATION "A-A" 0 First Submission 5th JULY 2020
J Ø 100 PUDDLE FLANGE FOR DRAIN PIPE REV DESCRIPTION DATE
ISSUE
STATUS :-
SHOP DRAWING
* THIS PUMP INSTALLATION IS FOR REFERENCE ONLY
LEGEND: DISCIPLINE :-
THE DETAIL PUMP INSTALLATION WILL BE SUBMIT PLUMBING SYSTEM
SEPARATELY WITHIN DRAWING NO. P0102
PUMP ROOM DETAIL INCLUDE DIMENSION,
LEVEL, SIZE ETC.
P PG PRESSURE GAUGE GV DRAWING TITLE :-
DOMESTIC WATER TANK & PUMP ROOM DETAIL
(APARTMENT) - BUILDER'S WORK
ST STRAINER
DRAWING No :- Rev.
P0103A
NRV NON RETURN VALVE 1
DATE : SHEET NO : Scale: Size
05-07-2020 1 OF 1 1:50 A1
FC FLEXIBLE CONNECTION
Detailed By: Drawn By: Checked By: Approved By:
HKL HKL XYN XYN
GV GATE VALVE
DETAIL D - D Sign: Sign: Sign: Sign:

Date Date Date Date


05-07-2020 05-07-2020 05-07-2020 05-07-2020