Ultrasonic Sensor: 1 Leds
Ultrasonic Sensor: 1 Leds
Ultrasonic Sensor: 1 Leds
Ultrasonic sensor
UGC00300EOKG/IO-Link/US
1 LEDs
Product characteristics
Electrical design PNP
Output function normally open / closed; (configurable)
Sensing range [mm] 40...300; (Target: 200 x 200 mm)
Communication interface IO-Link
Housing Threaded type
Dimensions [mm] M18 x 1 / L = 60.5
Electrical data
Operating voltage [V] 10...30 DC; (cULus - Class 2 source required)
Current consumption [mA] < 35
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.3
Converter frequency [kHz] 300
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1
Inputs
Synchronization input no
Multiplex input no
Outputs
Total number of outputs 1
Electrical design PNP
Number of digital outputs 1
Output function normally open / closed; (configurable)
Max. voltage drop switching
[V] 2.2
output DC
Permanent current rating of
[mA] 100
switching output DC
Switching frequency DC [Hz] 8
Short-circuit protection yes
Overload protection yes
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — UGT212-00 — 15.10.2020 —
UGT212
Ultrasonic sensor
UGC00300EOKG/IO-Link/US
Monitoring range
Sensing range [mm] 40...300; (Target: 200 x 200 mm)
Blind zone [mm] 40
Angle of aperture cylindrical [°] 15; (±2)
Max. deviation from the 90°
[°] ±4
angle sensor/object
Accuracy / deviations
Temperature compensation yes
Hysteresis [%] <1
Switch-point drift [%] -2...2
Repeatability <0,7 %
Resolution [mm] 1
Notes on the accuracy /
The indicated values are reached after a warm-up time of min. 20 minutes
deviation
Software / programming
hysteresis / window; second switch point; Switch-on and switch-
Parameter setting options
off delay; switch-on operations; Teach function; light-on/dark-on mode
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type
Profiles
0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel
SIO mode yes
Required master port class A
Min. process cycle time [ms] 3.2
Function bit length
IO-Link process data process value 16
(cyclical) device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter
Type of operation DeviceID
Supported DeviceIDs
default 889
Note For further information please see the IODD PDF file at "Downloads"
Operating conditions
Ambient temperature [°C] -20...70
Storage temperature [°C] -30...80
Protection IP 67
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — UGT212-00 — 15.10.2020 —
UGT212
Ultrasonic sensor
UGC00300EOKG/IO-Link/US
Tests / approvals
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 3 V/m
EMC EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 3V
EN 55011 class A
(10-55) Hz 1 mm amplitude,
Vibration resistance EN 60068-2-6 Fc vibration duration 5 min., 30 min.
per axis with resonance or 55 Hz
30 g 11 ms half-sine; 3 shocks each in
Shock resistance EN 60068-2-27 Ea
every direction of the 3 coordinate axes
Ta -20...70 °C
UL approval voltage supply Class 2
File number UL E174191
Mechanical data
Weight [g] 57
Housing Threaded type
Dimensions [mm] M18 x 1 / L = 60.5
Thread designation M18 x 1
Material PBT; PA; epoxy glass ceramics
Tightening torque [Nm] 1
Displays / operating elements
Switching status 1 x LED, yellow
Display
echo 1 x LED, green
Accessories
lock nuts: 2, plastics
Items supplied
rubber washers: 2
Remarks
Remarks cULus - Class 2 source required
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — UGT212-00 — 15.10.2020 —
UGT212
Ultrasonic sensor
UGC00300EOKG/IO-Link/US
Connection
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — UGT212-00 — 15.10.2020 —
UGT212
Ultrasonic sensor
UGC00300EOKG/IO-Link/US
1: Distance
2: Monitoring range
3: switch-on/switch-off graph
4: Target 100 x 100 mm
5: 50 % of the target in the detection zone
6: Set point
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — UGT212-00 — 15.10.2020 —