Dominus CT Scan 16/32 Slice: High Quality Image

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DOMINUS

CT SCAN 16/32 SLICE

HIGH QUALITY IMAGE


Perfect size of 0.6 mm slice thickness detector
Advance iterative reconstruction based on the noise model
0.7 second per rotation high speed scan

ADVANCED FEATURES
3.5M Metal high capacity X-ray tube
350 mA Tube current selection
3.5 mHU Anode heat capacity

FULL RANGE APPLICATION


Multi-Planar/3D Volume reconstruction
Iterative reconstruction algorithm
70 kV Advanced low dose scan

PT. Harmoni Nasional Teknologi Indonesia

+62 21 2568 4265 support@hntindonesia.id


DOMINUS_ HNT Indonesia

SPECIFICATIONS

Gantry Operation Console


Gantry Aperture 70 cm CPU 4 Cores, 3.0 GHz
Tilt ± 45⁰ Digital Hard disk capacity 2 TB, Up to 1,200,000
Scan FOV 43 cm Monitor Display 24” LCD, 1024x1024
Rotation Speed @360⁰ 0.7sec - 2.0sec
Focus to detector Distance 968 mm Generator
ISO Center to ground Distance 900 mm
Laser Localizer 3D localizer laser lamp Max. Output 42 kw
Axial position accuracy MA range 10 mA ~ 350 mA
≤ 1 mm
Coronal and Sagittal position accuracy kV range 70 kV/80 kV/100 kV/120 kV/140 kV
≤ 2 mm
Continuous scan time 100sec

Patient Table Reconstruction Parameters


Table board width 42 cm Image Slice Thickness 0.6 mm, 1 mm, 2 mm, 3 mm, 5 mm, 7 mm, 10 mm
Table load capacity 206kg Image Interval 0.1 mm
Max. range of horizontal movement 1,600 mm Reconstruction FOV 50 mm ~ 600 mm
Reconstruction matrix 512 x 512,768 x 768,1024 x 1024
Max. scan range 1,400 mm
Reconstruction speed 12 images/sec
Position accuracy ± 0.25 mm Auto voice Preset (English, Chinese) & user-defined
Horizontal movement speed 2.5-150 mm/s voice messages.
Vertical Movement Range 350 mm Pre-View Provide fast view function in scan parameter
Min. table height 540 mm setting Interface.
Operation control speed 20 mm/s and 150 mm/s Auto send Automatically send the scan study to workstation
or PACS.
Auto mA Optimizes the dose for patient based on
Detector the planned scan by suggesting the lowest
possible mAs settings to maintain constant image
Detector material GOS solid state
Detector rows 24
Clinical Images (High Quality & Smart Exposure Detection)
Detector channel 18,432
Total channel No. per row 768
Slice thickness 0.6 mm
Detector width 19.2 mm
Data transfer rate 4.25 Gbps
Data sampling rate 2,304 views/rotation

Spiral Scan
Scan Speed @360⁰
0.7s - 1.0s
kV option
70, 80, 100, 120, 140 kV
mA option
10 mA ~ 350 mA
Max. exposure time
100 sec
Helical pitch factor
0.3~1.5 multi option
Acquisition mode
16 x 1.2 mm, 16 x 0.6 mm
Pre-Scan Delay setting
Allow users to set the pre scan delay time, the minimum delay time is related to scan
parameter and system will automatically set the minimum delay time based on
the scan parameters.

X-ray tube Detector X-ray Tube


Anode heat capacity 3.5 mHU
Max. anode heat dissipation rate 735 kHU/min
Focal spot size 1.2mm x 1.4mm (large), Distributed By:
0.7mm x 0.8mm (small)

Designed for long tube life with no tube cooling delay.


With iterative reconstruction technology at maintained image quality the same clinical PT. Harmoni Nasional Teknologi Indonesia
results can be achieved with less dose, filling up the heat storage of the system more Ruko Rich Palace, No.36-40 Blok D5, Jl. Meruya Ilir, RT 008 /RW 007
slowly, therefore increasing the heat storage capacity. www.hntindonesia.id Kel. Srengseng, Kec. Kembangan Jakarta Barat 11620