AIR

CONDITIONERS

Product Catalogue for European market 2020/2021


FUNCTIONAL TECHNOL
Modern and economical rotational compressors

The air conditioner is usually used at partial capacity,


which is much less than its declared effectiveness. These
conditions are key to reducing electricity consumption

3-YEAR GUARANTEE
THE KOREAN PRODUCERS gives a three-year fac-
tory guarantee on all the devices in its product
3
YEAR
range. Additionally, the rapid availability of spare GUARANTEE
parts is a guarantee for the long-term functioning
of devices, even under the most difficult working
conditions.

DC motor com- Neodymium


pressor magnets
ROTATIONAL
COMPRESSOR
WIFI CONNECTIVITY
YOU ARE NOW ABLE TO The tested compressors
TAKE full control of your air- installed in the Hyundai air
conditioner from anywhere in conditioners are a guarantee
the world, from your mobile for low energy consumpti-
phone, tablet or computer. on. Assisted by the precise
Most of Hyundai line-up regulation of compressor
comes with WiFi connection Magnetic force operation, the Hyundai air
as standard, as well as a free conditioners are exceptio-
+ nally economical, under all
WiFi application
Force transformer working conditions.

2 HYUNDAI 2020/2021
LOGY
ensure minimal electricity consumption

ERP REGULATIONS
IN EFFECT IN THE EU
IN EARLY 2013, the ERP (Energy
Related Products) Regulations came
into effect, limiting electricity con-
sumption of air conditioners. With
the introduction of new energy
classes (A+++, A++ and A+) and the
termination of previous classed (E, F,
G), the EU set stricter consumption
limits.

LABEL FOR THE NEW “ENERGY EFFICIENCY”


Energy efficiency classes A+++ Name or trademark of the manufacturer
to D SEER in cooling mode
Name of device/model code
A +++ > 8,5
SEER and SCOP
A ++ > 6,1 SEER (Seasonal Energy Efficiency Ratio)
A+ > 5,6 lists the seasonal energy efficient ratio in
cooling mode
A > 5,1
HRH-09GCV SCOP (Seasonal Coefficient of Performan-
B > 4,6 ce) lists the seasonal efficiency coefficient
C > 4,1 in the heating mode

D < 3,6 Energy efficiency classes A+++ to D


SCOP in heating mode
Classification of energy efficiency
Energy efficiency classes in the cooling
and heating modes of individual device A++ A +++ > 5,1
models
A+ A ++ > 4,6
A+ > 4,0
A > 3,4
B > 3,1
C > 2,8
Cooling capacity D < 2,5
SEER-value
Annual consumption of
electrical energy for cooling 2,5 X 3,2 X Design load in heating mode
6,1 X 4,1 X SCOP-value
145 X 1055 X Annual consumption of electrical energy
for heating
Noise levels during operation
of indoor/outdoor unit Climate zones
The level of noise is listed for the indoor The EU has been divided into three
and outdoor units, which unlike sound
pressure does not depend on place of
56 dB climate zones for the classification in the
heating mode
source or recipient

Cooling capacity Cooling capacity Weather information with data on the


≤ 6 kW > 6 kW ≤ 12 kW label

Indoor
unit
Outdoor
unit
Indoor
unit
Outdoor
unit 60 dB
60 dB(A) 65 dB(A) 65 dB(A) 70 dB(A)

HYUNDAI 2020/2021 3
ACTIVE PROCESSING OF
During operation, the air conditioner processes

Model Wall unit Self-standing


unit

Function Performance inverter Plus Elite inverter Plus Super inverter Ceiling unit

Anti-allergy filter ● ● ●

Auto-diagnosis ● ● ●

Automatic mode ● ● ● ●

Automatic restart ● ● ● ●

Eco mode ● ●

Self-cleaning function ● ● ● ●

High Power mode ●

Air ionizer ● ● ● ●

Catechin filter ● ●

Low noise outdoor unit


Temperature maintenance 8-10°C ● ● ● ●

Plasma filter ●

Person presence sensor


Quiet operation
Timer ● ● ● ●

WiFi connection ● ● ● ●

Wifi povezivost ● ● ●

4 HYUNDAI 2020/2021
AIR THAT YOU BREATHE
the air that is inhaled by everyone in the room

Built-in unit

AIR IONISER
CAPABLE OF PRODUCING UP TO 35,000 NEGATIVELY CHARGED
IONS PER CUBIC CENTIMETER OF AIR. This is the value similar to the
air quality near waterfalls, and is higher than the air quality in forests.
The emission of negative ions equalises the excess of positive ions
present in indoor spaces, and achieves ion concentrations similar to
the air in the cleanest parts of Earth.

BUILT-IN HEATER
4-way cassette Duct unit ALL INVERTER PRO UNITS have
a preinstalled heater in out-
door unit which dispenses heat
towards compressor and con-
densate tub in order to achieve
● ● smooth operation during low
ambient temperatures.
● ●

● ● COOLING AT TEMPERATURE UP TO +46°C


● ● HYUNDAI AIR CONDITIONERS ARE CAPABLE OF COOLING in con-
ditions of outdoor temperatures of up to +46°C. The heating func-
● ●
tion is available to temperatures of -15°C.

● ●

● ●

● ●

● ●

● standard equipment optional equipment

HYUNDAI 2020/2021 5
PERFORMANCE
INVERTER PLUS
Thanks to eco-friendly R32 refridgerant, Performance
Inverter model is able to achieve high energy efficiency.
Easy installation will minimize time required to install or
service these units by installers

WIFI ALL EASY AIR CONSTANT 8˚C


CONNECTED INSTALL IONIZER DEGREES
The device can be connec- Installation and service The system generates Function which is maintai-
ted with an WiFiinterface, process are time saving, negative ions, which lar- ning constant room tempe-
and complete control of and both installers and gely improve the air qua- rature of 8˚C. Excellent for
the air conditioner is possi- consumers will benefit lity, positively affecting the usage on villas and beach
ble via smartphone, tablet from this feature exchange of matter and houses which are not occu-
or computer dissolution of tension in pied out of season
the body

6 HYUNDAI 2020/2021
OPERATION FR -15°C FR -15°C ENERGY SEER ++ SCOP A+
RANGE TO +50°C TO +30°C EFFICIENCY 6,2 A 4,0
Data pertain to 2,6 kW model

REFRIGERANT

INDOOR UNIT HRH-09BMV HRH-12BMV HRH-18BMV HRH-24BMV


OUTDOOR UNIT HRO-09BMV HRO-12BMV HRO-18BMV HRO-24BMV
Cooling capacity kW 2,6 3,5 5,3 7
Cooling capacity range (min-max) kW 0,9 - 3,4 1,1 - 4,2 1,8 - 6,1 2,1 - 7,9
Energy consumption kW 0,10 - 1,24 0,13 - 1,58 0,14 - 2,36 0,16 - 2,96
Pdesignc kW 2,6 3,5 5,2 7
SEER / Energy class 6,20 / A++ 6,1 / A++ 7,1 / A++ 6,1 / A++
Heating capacity kW 2,9 3,8 5,6 7,3
Heating capacity range (min-max) kW 0,8 - 3,4 1,1 - 4,2 1,4 - 6,7 1,6 - 8,8
Energy consumption kW 0,12 - 1,20 0,10 - 1,58 0,20 - 2,41 0,26 - 3,14
Pdesignh kW 2,1 2,3 4,1 4,8
SCOP / Energy class 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+
Indoor unit HRH-09BMV HRH-12BMV HRH-18BMV HRH-24BMV
Air flow m /h
3
520 600 840 980
Noise level dB(A) 21 / 40 21 / 42 21 / 43 25 / 46
Dimensions (HxWxD) mm 285 x 805 x 194 285 x 805 x 194 302 x 957 x 213 327 x 1040 x 220
Weight kg 7,5 7,5 10 12,3
Outdoor unit HRO-09BMV HRO-12BMV HRO-18BMV HRO-24BMV
Noise level dB(A) 56 56 56 59
Dimensions (HxWxD) mm 550 x 700 x 275 550 x 700 x 275 554 x 800 x 333 702 x 845 x 363
Weight kg 22,7 22,7 34 51
Compressor type rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni
Gas side mm (in) mm (col) 9,52 (3/8) 9,52 (3/8) 12,7 (1/2) 15,9 (5/8)
Liquid side mm (in) mm (col) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 9,52 (3/8)
Maximum piping length m 25 25 30 50
Maximum piping height difference m 10 10 20 25
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Refrigerant R32/675 R32/675 R32/675 R32/675
Filling in kg/tonnes CO2 – Equ. 0,50 / 0,33 0,50 / 0,33 1,00 / 0,67 1,60 / 1,08
hlađenje grijanje

HYUNDAI 2020/2021 7
ELITE
INVERTER PLUS
Top of the range model from a Korean manufacturer is
runing R32 refrigerant, which is only a part of the reason
why this model excels in innovative desing and high
performance results

WIFI ALL EASY AIR SELF-CLEANING


CONNECTED INSTALL IONIZER FUNCTION
The device can be connec- Installation and service The system generates Once the device ends its
ted with an WiFiinterface, process are time saving, negative ions, which lar- operation, the internal fan
and complete control of and both installers and gely improve the air qua- turns to completely dry
the air conditioner is possi- consumers will benefit lity, positively affecting the out the coil and prevent
ble via smartphone, tablet from this feature exchange of matter and the formation of moisture
or computer. dissolution of tension in inside the indoor unit
the body

8 HYUNDAI 2020/2021
OPERATION FR -15°C FR -15°C ENERGY SEER ++ SCOP A+
RANGE TO +50°C TO +30°C EFFICIENCY 6,8 A 4,0
Data pertain to 2,6 kW model

REFRIGERANT

INDOOR UNIT HRH-09GMV1 HRH-12GMV1 HRH-18GMV1


OUTDOOR UNIT HRO-09GMV1 HRO-12GMV1 HRO-18GMV1

Cooling capacity kW 2,6 3,5 5,3


Cooling capacity range (min-max) kW 1,2 - 3,4 1,4 - 4,6 2,0 - 6,2
Energy consumption kW 0,10 - 1,32 0,11 - 1,74 0,15 - 2,22
Pdesignc kW 2,6 3,5 5,3
SEER / Energy class 6,80 / A++ 6,30 / A++ 6,70 / A++
Heating capacity kW 2,9 4,1 5,6
Heating capacity range (min-max) kW 0,8 - 3,9 0,9 - 5,1 1,3 - 7,0
Energy consumption kW 0,14 - 1,38 0,15 - 1,83 0,22 - 2,33
Pdesignh kW 2,2 2,5 4,0
SCOP / Energy class 4,00 / A+ 4,00 / A+ 4,00 / A+
Indoor unit HRH-09GMV1 HRH-12GMV1 HRH-18GMV1
Air flow m /h
3
486 550 810
Noise level dB(A) 21 / 41 23 / 41 24 / 45
Dimensions (HxWxD) mm 302 x 717 x 193 302 x 805 x 193 325 x 964 x 222
Weight kg 7,5 8 11
Outdoor unit HRO-09GMV1 HRO-12GMV1 HRO-18GMV1
Noise level dB(A) 55 55 57
Dimensions (HxWxD) mm 555 x 770 x 300 555 x 770 x 300 554 x 800 x 333
Weight kg 26 26 37
Compressor type rotacijski rotacijski rotacijski
Gas side mm (in) mm (col) 9,52 (3/8) 9,52 (3/8) 12,7 (1/2)
Liquid side mm (in) mm (col) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4)
Maximum piping length m 25 25 30
Maximum piping height difference m 10 10 20
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Refrigerant R32/675 R32/675 R32/675
Filling in kg/tonnes CO2 – Equ. 0,70/0,47 0,80/0,54 1,25/0,84
cooling heating

HYUNDAI 2020/2021 9
SUPER
INVERTER
Air ionizer, WiFi control, gold-fin heat exchanger and triple
coating of outdoor unit are just to name a few special
features of this remarkable unit. Super inverter is super quiet
in operation and has high energy efficiency

HEATER IN
TRIPLE COATING OUTDOOR UNIT AIR WIFI
PAINT IONIZER CONNECTED
Triple coating of outdoor unit Preinstalled heater in The system generates The device can be connec-
insures high resistance level outdoor unit guarantees negative ions, which lar- ted with an WiFiinterface,
to corosion. After 500 hours heating operation range up gely improve the air qua- and complete control of
of acid impact, outdoor unit to -15°C lity, positively affecting the the air conditioner is possi-
is still corosion free exchange of matter and ble via smartphone, tablet
dissolution of tension in or computer.
the body

10 HYUNDAI 2020/2021


OPERATION FR -15°C FR -15°C ENERGY SEER ++ SCOP ++
RANGE TO +50°C TO +30°C EFFICIENCY 8,3 A 4,6 A

Data pertain to 2,6 kW model

REFRIGERANT

INDOOR UNIT HRH-09PMV HRH-12PMV


OUTDOOR UNIT HRO-09PMV HRO-12PMV
Cooling capacity kW 2,6 3,5
Cooling capacity range (min-max) kW 1,0 - 3,2 1,4 - 4,3
Energy consumption kW 0,09 - 1,14 0,13 - 1,65
Pdesignc kW 2,6 3,5
SEER / Energy class 8,30 / A++ 7,5 / A++
Heating capacity kW 2,9 3,8
Heating capacity range (min-max) kW 0,8 - 3,4 1,1 - 4,4
Energy consumption kW 0,11 - 1,08 0,16 - 1,56
Pdesignh kW 2,3 2,3
SCOP / Energy class 4,60 / A++ 4,60 / A++
Indoor unit HRH-09PMV HRO-12PMV
Protok zraka m /h
3
550 550
Razina buke dB(A) 22 / 39 22 / 41
Dimenzije (V׊×D) mm 302 x 805 x 193 302 x 805 x 193
Težina kg 8,3 8,3
Outdoor unit HRO-09PMV HRH-12PMV
Noise level dB(A) 56 56
Dimensions (HxWxD) mm 554 x 800 x 333 554 x 800 x 333
Weight kg 29,6 29,6
Compressor type rotacijski klipni rotacijski klipni
Gas side mm (in) mm (col) 9,52 (3/8) 9,52 (3/8)
Liquid side mm (in) mm (col) 6,35 (1/4) 6,35 (1/4)
Maximum piping length m 25 25
Maximum piping height difference m 10 10
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Filling in kg/tonnes CO2 – Equ. R32/675 R32/675
cooling heating

HYUNDAI 2020/2021 11
MULTI INVERTER
Outdoor unit

OPERATION FR -15°C FR -15°C ENERGY SEER ++ SCOP +


RANGE TO +50°C TO +24°C EFFICIENCY 6,5 A 4,0 A

Data pertain to 6,2 kW model

HRO 2M18MVA
Possibility of connecting up
to 2 indoor units

Cooling capacity Heating capacity Dimensions


Model Energy class
(kW) (kW) (H/W/D)

HRO 2M18MVA
HRO 2M18MVA 5,3 5,6 A++/A+ 554 / 800 / 333

HRO 3M21MVA, HRO 3M27MVA


Possibility of connecting
up to 3 indoor units

Cooling capacity Heating capacity Dimensions


Model Energy class
(kW) (kW) (H/W/D)

HRO 3M21MVA, HRO 3M27MVA


HRO 3M21MVA 6,2 6,6 A++/A+ 702 / 845 / 363
HRO 3M27MVA 7,9 8,2 A++/A+ 702 / 845 / 363

HRO 4M28MVA, HRO 4M36MVA


Possibility of connecting
up to 4 indoor units

Cooling capacity Heating capacity Dimensions


Model Energy class
(kW) (kW) (H/W/D)

HRO 4M28MVA, HRO 4M36MVA


HRO 4M28MVA 8,2 8,8 A++/A+ 810 / 946 / 410
HRO 4M36MVA 10,5 10,5 A++/A+ 810 / 946 / 410

HRO 5M42MVA
Possibility of connecting
up to 5 indoor units
Cooling capacity Heating capacity Dimensions
Model Energy class
(kW) (kW) (H/W/D)

HRO 5M42MVA
HRO 5M42MVA 12,3 12,3 A++/A 810 / 946 / 410

12 HYUNDAI 2020/2021


MULTI INVERTER
Indoor units

WALL MOUNTED UNITS

WALL MOUNTED UNITS HRH M09SMVA HRH M12SMVA HRH M18SMVA HRH M24SMVA
Cooling capacity kW 2,6 3,5 5,2 7,3
Heating capacity kW 2,9 4,1 5,6 7,6
Air flow m3/h 329 - 486 360 - 550 550 - 810 650 - 1050
Noise level dB(A) 20 / 41 23 / 41 24 / 45 27 / 46
Dimensions (HxWxD) mm 302 x 717 x 193 302 x 805 x 193 325 x 964 x 222 342 x 1106 x 232
Weight kg 7,8 8,2 10,8 14,3

CASSETTE UNITS

INDOOR UNITS HRC M09MVA HRC M12MVA HRC M18MVA


Cooling capacity kW 2,6 3,5 5,2
Heating capacity kW 2,9 4,1 5,4
Air flow m3/h 450 - 580 415 - 617 500 - 680
Noise level dB(A) 29 / 38 34 / 41 41 / 44
Dimensions (HxWxD) mm 260 x 570 x 570 260 x 570 x 570 260 x 570 x 570
Weight kg 14,5 16,2 16,2

FLOOR UNIT

INDOOR UNITS HRP M12MVA HRP M16MVA


Cooling capacity kW 3,5 4,8
Heating capacity kW 3,8 5,0
Air flow m3/h 370 - 512 400 - 560
Noise level dB(A) 35 / 43 25 / 42
Dimensions (HxWxD) mm 700 x 600 x 210 700 x 600 x 210
Weight kg 14,8 14,8

OUTDOOR UNITS
Multisplit Multisplit
Multisplit for 3 rooms Multisplit for 4 rooms
OUTDOOR UNITS for 2 rooms for 5 rooms
HRO 2M18MVA HRO 3M21MVA HRO 3M27MVA HRO 4M28MVA HRO 4M36MVA HRO 5M42MVA
Cooling capacity kW 5,3 6,2 7,9 8,2 10,5 12,3
Power load kW 1,63 1,90 2,45 2,50 3,31 4,10
SEER/Energy class 6,10 / A++ 6,50 / A++ 6,10 / A++ 7,00 / A++ 6,50 / A++ 6,80 / A++
Heating capacity kW 5,6 6,6 8,2 8,8 10,5 12,3
Power load kW 1,50 1,77 2,20 2,40 2,88 3,30
SCOP/Energy class 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+ 3,80 / A
Noise level dB(A) 56 57 54 61 62 64
Dimensions (HxWxD) mm 554 x 800 x 333 702 x 845 x 363 702 x 845 x 363 810 x 946 x 410 875 x 1090 x 500 875 x 1090 x 500
Weight kg 35,5 46,8 51,1 62,1 68,8 73,3
Gas side (mm/in) mm (col) 2 x 9,52 (3/8) 3 x 9,52 (3/8) 3 x 9,52 (3/8) 3 x 9,52 + 1 x 12,7 3 x 9,52 + 1 x 12,7 4 x 9,52 + 1 x 12,7
Liquid side (mm/in) mm (col) 2 x 6,35 (1/4) 3 x 6,35 (1/4) 3 x 6,35 (1/4) 4 x 6,35 (1/4) 4 x 6,35 (1/4) 5 x 6,35 (1/4)
Maximum piping length
(total/per unit) m 40 / 25 60 / 30 60 / 30 80 / 35 80 / 35 80 / 35
Maximum piping height difference m 15 15 15 15 15 15
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50

HYUNDAI 2020/2021 13
CASSETTE
UNITS
Hyundai Inverter Pro series is aimed at light commercial users.
Four way cassette type unit adapts to any interior and can
efficiently and quitly cool or heat big spaces. Outdoor units
come equiped with pre-installed heaters and gold-fin heat

REMOTE
CONTROL
Infra-red remote
controller has a
modern design and
backlighted screen

HCO48/55YMV HCO36YMV HCO24VMV HCO18VMV HCO12VMV

14 HYUNDAI 2020/2021


OPERATION FR -15°C (-15°C) FR -20°C ENERGY SEER ++ SCOP +
RANGE TO +50°C TO +24°C EFFICIENCY 6,1 A 4,0 A

Data pertain to 5.3 kW models


Data in brackets pertain to 10.5/14.0/16.0 kW models

INDOOR UNIT HCC 12 VMV HCC 18 VMV HCC 24 VMV HCC 36 VMV HCC 48 VMV HCC 55 VMV
OUTDOOR UNIT HCO 12 VMV HCO 18 VMV HCO 24 VMV HCO 36 YMV HCO 48 YMV HCO 55 YMV

Cooling capacity kW 3,52 5,28 7,03 10,55 14,07 15,5


Cooling capacity range (min-max) kW 1,52 - 5,28 2,90 - 5,74 3,22 - 8,21 4,04 -12,02 4,75 -14,58 5,28 - 16,71
Energy consumption kW 0,35 - 1,60 0,72 - 1,86 0,48 - 2,85 0,89 - 4,50 1,17 - 5,60 1,15 -6,68
SEER/energy class 7,8 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++
Heating capacity kW 4,40 5,42 7,6 11,14 16,12 18,2
Heating capacity range (min-max) kW 1,03 - 5,57 2,37 - 6,10 2,43 - 8,65 2,95 - 14,14 3,93 - 16,77 4,40 -19,34
Energy consumption kW 0,31 - 1,80 0,7 -1,93 0,5 - 2,88 0,72 -4,75 0,99 - 5,38 1,02 -6,45
SCOP/energy class 4,6 / A++ 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+
Indoor unit HCC 12 VMV HCC 18 VMV HCC 24 VMV HCC 36 VMV HCC 48 VMV HCC 55 VMV
Air flow m /h
3 617 720 1378 1775 1715 1970
Noise level dB(A) 33 / 41 36 / 43 40 / 47 41 / 51 49 / 52 48 / 53
Dimensions (HxWxD) mm 260 x 570 x 570 260 x 570 x 570 205 x 840 x 840 245 x 840 x 840 287 x 840 x 840 287 x 840 x 840
Weight kg 16,2 16,2 23 27,5 29 29,7
Outdoor unit HCO 12 VMV HCO 18 VMV HCO 24 VMV HCO 36 YMV HCO 48 YMV HCO 55 YMV
Noise level dB(A) 56 55 62 65 66 66
Dimensions (HxWxD) mm 554 x 800 x 333 554 x 800 x 333 702 x 845 x 363 810 x 946 x 410 1333 x 952 x 415 1333 x 952 x 415
Weight kg 34,7 33,7 66,8 66,8 106,7 111,3
Compressor type: rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni
Gas side mm (in) mm (col) 9,52 (3/8") 12,7 (1/2") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8") 15,88 (5/8")
Liquid side mm (in) mm (col) 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8")
Maximum piping length m 25 30 50 65 65 65
Maximum piping height difference m 10 20 25 30 30 30
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Refrigerant R32/675 R32/675 R32/675 R32/675 R32/675 R32/675
Filling in kg/tonnes CO2 - Equ. 0,87/0,59 1,15/0,78 1,50/1,01 2,40/1,62 2,80/1,89 2,95/1,99
Grille is incluedd, as well as IR remote controller
cooling heating

HYUNDAI 2020/2021 15
CEILING
UNITS
Hyundai Inverter Pro series is aimed at light commercial users.
Ceiling units help distribute cold or warm air to places that
other units can not reach. Outdoor units come equiped with
pre-installed heaters and gold-fin heat exchangers

REMOTE
CONTROL
Infra-red remote
controller has a
modern design and
backlighted screen

HCO48/55YMV HCO36YMV HCO24VMV HCO18VMV HCO12VMV

16 HYUNDAI 2020/2021


OPERATION FR -15°C (-15°C) FR -20°C ENERGY SEER ++ SCOP +
RANGE TO +50°C TO +24°C EFFICIENCY 6,1 A 4,0 A

Data pertain to 5.3 kW models


Data in brackets pertain to 10.5/14.0/16.0 kW models

INDOOR UNIT HCF 18 VMV HCF 24 VMV HCF 36 VMV HCF 48 VMV HCF 55 VMV
OUTDOOR UNIT HCO 18 VMV HCO 24 VMV HCO 36 YMV HCO 48 YMV HCO 55 YMV

Cooling capacity kW 5,28 7,0 10,55 14,07 15,83


Cooling capacity range (min-max) kW 2,64 - 6,15 3,22 - 8,29 3,93 - 12,02 4,96 - 15,11 5,28 -17,00
Energy consumption kW 0,28 -2,05 0,48 -2,93 0,87 -4,50 1,16 - 6,00 1,23 - 6,50
SEER/Energy class 6,1 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++
Heating capacity kW 5,57 7,62 11,14 16,12 18,17
Heating capacity range kW 2,27 - 7,03 2,72 - 8,65 2,81 - 13,95 3,81 -18,07 4,40 -19,64
Energy consumption kW 0,33 - 2,18 0,50 - 2,85 0,73 - 4,89 1,03 - 6,2 1,02 - 6,55
SCOP/Energy class 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+
Indoor unit HCF 18 VMV HCF 24 VMV HCF 36 VMV HCF 48 VMV HCF 55 VMV
Air flow m /h
3 902 1208 2160 2329 2454
Noise level dB(A) 37 / 45 41 / 50 42 / 51 46 / 54 42 / 54
Dimensions (HxWxD) mm 235 x 1068 x 675 235 x 1068 x 675 235 x 1650 x 675 235 x 1650 x 675 235 x 1650 x 675
Weight kg 26,6 26,8 39 41,2 41,4
Outdoor unit HCO 18 VMV HCO 24 VMV HCO 36 YMV HCO 48 YMV HCO 55 YMV
Noise level dB(A) 55 62 65 66 66
Dimensions (HxWxD) mm 554 x 800 x 333 702 x 845 x 363 810 x 946 x 410 1333 x 952 x 415 1333 x 952 x 415
Weight kg 33,7 66,8 66,8 106,7 111,3
Compressor type rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni
Gas side mm (in) mm (col) 12,7 (1/2”) 15,88 (5/8”) 15,88 (5/8”) 15,88 (5/8”) 15,88 (5/8”)
Liquid side mm (in) mm (col) 6,35 (1/4”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”)
Maximum piping length m 30 50 65 65 65
Maximum piping height difference m 20 25 30 30 30
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Refrigerant R32/675 R32/675 R32/675 R32/675 R32/675
Filling in kg/tonnes CO2 - Equ. 1,15/0,78 1,50/1,01 2,40/1,62 2,80/1,89 2,95/1,99
IR remote controller is included
cooling heating

HYUNDAI 2020/2021 17
DUCT
UNITS
Hyundai Inverter Pro series is aimed at light commercial
users. Duct units are ideal for hotel rooms because of low
noise level and good airflow. Outdoor units come equiped
with pre-installed heaters and gold-fin heat exchangers

REMOTE
CONTROL
Wallmounted remote comes
with numerous functions
which help increase comfort
level for users

HCO48/55YMV HCO36YMV HCO24VMV HCO18VMV HCO12VMV

18 HYUNDAI 2020/2021


OPERATION FR -15°C (-15°C) FR -20°C ENERGY SEER ++ SCOP +
RANGE TO +50°C TO +24°C EFFICIENCY 6,1 A 4,0 A

Data pertain to 5.3 kW models


Data in brackets pertain to 10.5/14.0/16.0 kW models

INDOOR UNIT HCD 12 VMV HCD 18 VMV HCD 24 VMV HCD 36 VMV HCD 48 VMV HCD 55 VMV
OUTDOOR UNIT HCO 12 VMV HCO 18 VMV HCO 24 VMV HCO 36 YMV HCO 48 YMV HCO 55 YMV

Cooling capacity kW 3,51 5,28 7,03 10,55 14,07 15,24


Cooling capacity range kW 1,49 - 4,75 2,55 -5,69 3,28 - 8,16 4,04 - 12,02 4,26 - 15,19 5,86 - 17,29
Energy consumption kW 0,35 -1,62 0,71 - 1,90 0,48 - 2,85 0,90 - 4,90 1,17 - 5,70 1,9 - 6,1
SEER/Energy class 6,5 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++ 6,1 / A++
Heating capacity kW 4,1 5,85 7,62 11,14 16,12 18,17
Heating capacity range kW 0,97 -5,63 2,20 -6,15 2,72 -8,72 2,81 - 13,19 3,70 - 18,02 4,69 - 20,52
Energy consumption kW 0,35 - 2,05 0,74 - 1,76 0,50 - 2,88 0,80 - 4,64 0,95 - 5,82 1,04 - 6,03
SCOP/Energy class 4,0 / A+ 4,0 / A+ 4,0 / A+ 4,00 / A+ 4,00 / A+ 4,00 / A+
Indoor unit HCD 12 VMV HCD 18 VMV HCD 24 VMV HCD 36 VMV HCD 48 VMV HCD 55 VMV
Air flow m /h
3
600 880 1248 1400 2400 2600
Noise level dB(A) 26 / 35 33 / 42 38 / 42 40 / 47 48 / 51 51 / 54
Dimensions (HxWxD) mm 200 x 700 x 450 210 x 880 x 674 249 x 1100 x 774 249 x 1360 x 774 300 x 1200 x 874 300 x 1200 x 874
Weight kg 18 24,3 31,5 40,5 47,6 47,6
Outdoor unit HCO 12 VMV HCO 18 VMV HCO 24 VMV HCO 36 YMV HCO 48 YMV HCO 55 YMV
Noise level dB(A) 56 55 62 65 66 66
Dimensions (HxWxD) mm 554 x 800 x 333 554 x 800 x 333 702 x 845 x 363 810 x 946 x 410 1333 x 952 x 415 1333 x 952 x 415
Weight kg 34,7 33,7 66,8 66,8 106,7 111,3
Compressor type rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni rotacijski klipni
Gas side mm (in) mm (col) 9,52 (3/8”) 12,7 (1/2”) 15,88 (5/8”) 15,88 (5/8”) 15,88 (5/8”) 15,88 (5/8”)
Liquid side mm (in) mm (col) 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”)
Maximum piping length m 25 30 50 65 65 65
Maximum piping height difference m 10 20 25 30 30 30
Power supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Refrigerant R32/675 R32/675 R32/675 R32/675 R32/675 R32/675
Filling in kg/tonnes CO2- Equ. 0,87/0,59 1,15/0,78 1,50/1,01 2,40/1,62 2,80/1,89 2,95/1,99
Wallmounted remote controller is included
cooling heating

HYUNDAI 2020/2021 19
MOBILE AIR
CONDITIONER
Practical, compact and
affordable… these are the main
characteristics of the mobile air
conditioners. They require no
construction works, and offer
perfectly cooled spa

Model HRM-09CMPV HRM-12HMPV


Cooling capacity kW 2,7 3,5
Energy consumption kW - 2,9
EER 2,8 2,6
Energy class cooling A A
COP - 2,8
Energy class heating - A+
dB
Noise level 62 64
(A)
Dimensions (H x W x D) mm 700 x 454 x 365 765 x 467 x 397
Weight kg 27 34
Refrigerant R290 R290
GWP 3 3

20 HYUNDAI 2020/2021


HVAC TOOLS
For cooling and air conditioning systems

Professional installers deserve only the best tools of the


trade. The high quality, durability and long-lasting tools we
offer are a guarantee of high quality installation services

VACCUUM ELECTRONIC REFRIGERANT DIGITAL


PUMP SCALE RECOVERY TOOL MANOMETERS
The pump is intended for use Capable of measuring up The tool is intended for the Precise manometers which
with the refrigerants R32, to 100 kg of medium with a recovery of refrigerant from are able to accurately mea-
R410A, R407C, R134a, R12, precision of 0.05%. Batteries the air conditioning system. It sure pressure in systems
R22 provide power for 80 hours is activated at the touch of a as well as check vacuum.
of operation, while the small button, and weighs only 13 kg. Comes in PVC box with
weight (4 kg) makes it easy Models with oil separator and matching tubing
to use refrigerant cleaning available

MANOMETERS UNIVERSAL RUBBER TUBING CUTTER


FLARING TOOL FOR REFRIGERANT With its compact size and high
Precise manometers mea-
The universal flaring tool For use with refrigerants R32, quality and long-lasting bla-
sure the pressure in systems
produces precision 45° sin- R410A, R134a, R12, R22. The des, this tool will delight you
using refrigerants R32, R410A,
gle flares on copper pipes rubber walls are reinforced with its performance and price
R134a, R22, R407C. The cla-
from ¼ to ¾ inch diameter and have a diameter of 12 mm.
ssification 1.6 is a guarantee of
Tubing is available in lengths
high precision
from 90 to 150 cm

HYUNDAI 2020/2021 21
CONNECTIONS
DATA
Brac-
Cooling/ Max pipe Max length Max height Gas Liquid Power Gas
Pre-charge Charge Connecti- Power kets
MODEL Heating length per unit difference pipes mm pipes mm Fuse cable quantity
(m) (gr/m) on (mm2) supply apart
(kW) (m) (m) (m) (zoll) (zoll) (mm2) (kg)
(cm)
HRO-09BMV 2,6/2,9 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 45 0,5
PERFORMANCE
HRO-12BMV 3,5/3,8 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 45 0,5
INVERTER
PLUS
R32 HRO-18BMV 5,3/5,6 30 20 5 12 12,7 (1/2”) 6,4 (1/4”) 16 5x1,5 Vanjska j. 3x2,5 51,5 1

HRO-24BMV 7,0/7,3 50 25 5 12 15,9 (5/8) 9,52 (3/8”) 20 5x1,5 Vanjska j. 3x2,5 54 1,6

HRO-09GMV1 2,6/2,9 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 0,7
ELITE
INVERTER HRO-12GMV1 3,5/4,1 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 48,7 0,8
R32
HRO-18GMV1 5,3/5,6 30 20 5 12 12,7 (1/2”) 6,4 (1/4”) 16 5x1,5 Vanjska j. 3x2,5 51,5 1,25

SUPER HRO-09PMV 2,6/2,9 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 51,5 0,65
INVERTER
R32 HRO-12PMV 3,5/3,8 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 51,5 0,65

HRO 2M18MVA 5,2/5,5 40 25 15 15 12 9,52 (3/8”) 6,4 (1/4”) 16 4x1,5 Vanjska j. 3x2,5 51,5 1,25

HRO 3M21MVA 6,2/6,6 60 30 15 22,5 12 9,52 (3/8”) 6,4 (1/4”) 16 4x1,5 Vanjska j. 3x2,5 54 1,4

HRO 3M27MVA 7,9/8,2 60 30 15 22,5 12 9,52 (3/8”) 6,4 (1/4”) 20 4x1,5 Vanjska j. 3x2,5 54 1,72

MULTI 3x9,52 (3/8”)


HRO 4M28MVA 8,2/8,8 80 35 15 30 12 6,4 (1/4”) 20 4x1,5 Vanjska j. 3x2,5 67,5 2,1
R32 1x12,7 (1/2”)

3x9,52 (3/8”)
HRO 4M36MVA 10,5/10,5 80 35 15 30 12 6,4 (1/4”) 25 4x1,5 Vanjska j. 3x2,5 67,5 2,1
1x12,7 (1/2”)
4x9,52 (3/8”)
HRO 5M42MVA 12,3/12,3 80 35 15 37,5 12 6,4 (1/4”) 25 4x1,5 Vanjska j. 3x4 67,5 2,4
2x12,7 (1/2”)

HCO 12 VMV 3,52/4,10 25 10 5 12 9,52 (3/8”) 6,4 (1/4”) 10 5x1,5 Vanjska j. 3x2,5 51,4 0,87

HCO 18 VMV 5,28/5,42 30 20 5 12 12,7 (1/2”) 6,4 (1/4”) 16 5x1,5 Vanjska j. 3x2,5 51,4 1,15

INVERTER HCO 24 VMV 7,03/7,62 50 25 5 24 15,9 (5/8) 9,52 (3/8”) 20 5x1,5 Vanjska j. 3x2,5 54 1,5
PRO
R32 HCO 36 YMV 10,55/11,14 65 30 5 24 15,9 (5/8) 9,52 (3/8”) 20 5x1,5 Vanjska j. 5X2,5 67,3 2,4

HCO 48 YMV 14,07/16,12 65 30 5 24 15,9 (5/8) 9,52 (3/8”) 25 5x1,5 Vanjska j. 5X2,5 63,4 2,8

HCO 55 YMV 15,53/18,17 65 30 5 24 15,9 (5/8) 9,52 (3/8”) 25 5x1,5 Vanjska j. 5X2,5 63,4 2,95

COMMERCIAL TERMS
 rices are FCO Zagreb
P W
 arranty: 36 months YEARS
3
Price does not include installation work P
 rices are subject to change without notice WARRANTY
Delivery time:
- central warehouse immediately
- order 3 - 5 work days only for RAS products

Thank you for your trust and business cooperation

22 HYUNDAI 2020/2021


NOTES

HYUNDAI 2020/2021 23
Authorised partner

ALFASOL d.o.o.
Kneza Branimira 189
10040 Zagreb, Croatia
tel/fax: +385 1 292 29 84
info@alfasol.hr
www.hyundaiequipment-adria.com

You might also like