Eplan Getting Started
Eplan Getting Started
Eplan Getting Started
06 / 2006
Copyright 2006 by EPLAN Software & Service GmbH & Co. KG EPLAN Software & Service GmbH & Co. KG assumes no liability for either technical or printing errors or for deficiencies in this technical information and cannot be held liable for damages that may directly or indirectly result from delivery, performance, and use of this material. This technical information includes information on the basis of a proprietary system that is protected by copyright laws. All rights reserved. These information or part thereof may not be copied or reproduced by any other means without the previous permission of EPLAN Software & Service. The software described in these technical information is subject to a licensing agreement. The software may only be used and copied within the scope of this agreement. EPLAN Electric P8 , EPLAN Fluid , EPLAN PPE and LOGOCAD TRIGA are registered trademarks of EPLAN Software & Service GmbH & Co. KG. MS-DOS / Windows NT / Windows 2000 / Windows XP / Microsoft Windows are registered trademarks of the Microsoft Corporation. Microsoft Excel and Microsoft Access are registered trademarks of the Microsoft Corporation. RITTAL is a registered trademark of the Rittal GmbH & Co. KG. CLIP PROJECT is a registered trademark of the Phoenix Contact GmbH & Co. INTERBUS is a registered trademark of the Phoenix Contact GmbH & Co. LFLEX, LFLEX-SERVO and LFLEX CLASSIC are registered trademarks of the U.I. LAPP GmbH. AutoCAD , Autodesk Inventor and VoloView Express are registered trademarks of Autodesk, Inc. SIMATIC HW Konfig is a registered trademark of the Siemens AG. PKZIP/PKUNZIP are registered trademarks of PKWARE, Inc. ObjectStore is a registered trademark of eXelon Corporation. D-ISAM is a registered trademark of Informix Software Inc. Hardlock E-Y-E is a registered trademark of Aladdin Knowledge Systems, Ltd Int. InstallShield is a registered trademark of InstallShield, Inc. PMS is a registered trademark of PMS Compelec GmbH. MicroStation is a registered trademark of Bentley Systems. Acrobat is a registered trademark of Adobe Systems Inc. All other product names, trade names and company names mentioned are trademarks or registered trademarks of their respective owners. Note: The hardware requirements indicated by the operating system manufacturers must be considered. Hardware combinations that cause malfunctions according to the manufacturers specification may also have an effect on the operation of EPLAN. Therefore an accurate basic installation of hardware, operating system, and hardware drivers (e.g. graphics board driver etc.) is essential for a smooth operation of EPLAN. For this reason, the main conditions and areas of application as specified by the hardware manufacturers also apply to the operation of EPLAN.
Table of Contents
Table of Contents
Introduction ........................................................................................... 3 User's Comments .............................................................................. 3 Remarks on the Practice Project...................................................... 4 Starting EPLAN ..................................................................................... 6 Getting to Know the EPLAN User Interface ........................................ 8 What You Need to Know in Advance ............................................... 9 Interface Elements............................................................................. 9 Changing the User Interface........................................................... 13 Creating a Project ............................................................................... 19 What you Need to Know in Advance.............................................. 19 Creating a Project Using the Project Wizard ................................. 20 Opening and Editing Pages................................................................ 25 What You need to Know in Advance.............................................. 26 Opening Pages ................................................................................ 26 Editing Page Properties .................................................................. 28 Creating a Page ............................................................................... 31 Opening and Closing a Project .......................................................... 34 Opening the Project ........................................................................ 34 Paging Through the Project Pages ................................................ 36 Creating a View................................................................................ 37 Closing the Project.......................................................................... 42 Creating a Schematic.......................................................................... 44 What you Need to Know in Advance.............................................. 44 Inserting "Angle" Connection Symbols......................................... 44 Inserting Potential Connection Points ........................................... 47 Inserting "T-node" Connection Symbols....................................... 50 Inserting Graphical Elements ......................................................... 51 Inserting General Devices............................................................... 54 Inserting Terminal Strips and Terminals ....................................... 62
Table of Contents Drawing Cable Definition Lines ...................................................... 66 Updating Connections .................................................................... 68 Inserting Path Function Texts ........................................................ 68 Inserting "Interruption Point" Connection Symbols ..................... 70 Generating Cross-references............................................................. 73 What you Need to Know in Advance.............................................. 73 Automatically Generating Interruption Point Cross-references .. 74 Inserting More Connection Symbols and General Devices.......... 76 Inserting Contactor Coils and Contact Images ............................. 79 Inserting Contacts and Contact Image for Motor Overload Switches........................................................................................... 83 Selecting Parts .................................................................................... 87 What you Need to Know in Advance.............................................. 87 Assigning Parts ............................................................................... 87 Generating Reports............................................................................. 96 Generating a Terminal Diagram...................................................... 96 Performing Settings for Parts Lists ............................................. 102 Printing Other Report Pages ........................................................ 103 Creating and Inserting Macros......................................................... 108 What you Need to Know in Advance............................................ 108 Creating a Window Macro............................................................. 108 Inserting a Window Macro ............................................................ 110 Finding and Replacing Identifiers.................................................... 114 Finding and Replacing Device Tags............................................. 114 Finding Text and Editing Search Entries ..................................... 119 Completing and Updating Reports .................................................. 122 Updating Reports .......................................................................... 122 Creating Report Templates........................................................... 123 Generating Project Reports .......................................................... 124 Printing a Project .............................................................................. 127
Introduction
Introduction
Dear users, The team at EPLAN Software & Service GmbH & Co. KG are pleased to welcome you as a new user. This guide is for users who have never used EPLAN. Using a practice project, we will familiarize you with the basic functions of EPLAN. Since this documentation is designed as an introduction to EPLAN, many of the more complicated functions and relationships will be ignored. These details are covered in our seminars, where you can also find help with your own individual and company-specific tasks. You should definitely take part in our seminar program in order to make the best use of the functionality and possibilities of the system. We provide you with an extensive online helpsystem in the program itself. In addition to conceptual information and dialog descriptions, here you will also find "step by step" instructions for most program functions. The "Proceed as follows" section of the operating information gives you step by step instructions for using the program. Once you have started the program and require information on a particular dialog, you can then call up the appropriate help by simply pressing the [F1] key.
User's Comments
Before you begin reading, please note the following symbols and styles used in this handbook: Note: Text preceded by this image contains extra Notes. Tip: After this image, useful tips to facilitate your interaction with the program are presented. Example: Examples are highlighted by this graphical symbol. User interface elements are marked in bold so they can immediately be located in the text. EPLAN Electric P8 Getting Started 3
Introduction Italic text provides particularly important information that you should definitely pay attention to. Directory names, and direct input (among other things) are displayed in a non-proportional font. Function keys, keyboard keys, and buttons within the program are shown in brackets (e.g., [F1] for the "F1" function key). To improve the flow of the text, we often use "menu paths" in this document (for example, Help > Contents). In order to find a particular program function, the menus and options shown in a menu path must be selected in the sequence shown. For example, the menu path mentioned above calls up the EPLAN help system. The operating information provides step-by-step instructions for reaching specific targets, and in many places, after the right-arrow symbol you'll also find the program's reaction to your action. In combination with settings or fields (e.g., check boxes) which can only be switched on or off, in this document we often use the term "activate" (after which the setting is active ) and "deactivate" (after which the setting is inactive ).
Introduction All settings can be made in a central location in the program (in the Options menu under the menu item Settings). For the practice project, we used the standard settings of the project template used. Don't change these settings while working with the practice project; otherwise you may see different results. You can control EPLAN using both the mouse and the keyboard. To quickly call up program functions, you often also have additional buttons on the toolbars and/or key combinations (e.g., [Ctrl] + [C] to copy elements). Since a list of the different call-up options would make this guide much larger, we usually use the mouse controls in the action instructions.
Starting EPLAN
Starting EPLAN
In this chapter, you will learn how to start EPLAN easily. During program installation, a program icon is created on the Windows Desktop. You can use this icon to start EPLAN immediately. 1. Double-click the EPLAN icon .
EPLAN starts. Beside the EPLAN main window, the dialog Tip of the day is also shown on the screen by default. In this informational dialog, which is automatically shown every time you start the program, you are shown useful information on program functions.
2. Deselect the Show tips at startup check box if you do not wish this dialog to appear every time the program is started. 3. Click on [Close] to close the Tip of the day. Before you create a project, you will first see a little more information about the user interface in the next chapter.
Starting EPLAN Note: You can leave EPLAN at any time by first closing all open dialogs with [Esc], [Cancel], or by clicking the mouse on in the title bar, and then selecting the menu item Project > Exit.
Interface Elements
Title bar
The horizontal bar at the top edge of a Windows application is the title bar. It contains the program icon with the system menu, the program name, and the buttons controlling the size setting of the window.
Getting to Know the EPLAN User Interface If you have a project open, then the name of the current project will also appear in the title bar, along with the name of the page opened, if applicable. Example: This is how the title bar looks if you have opened the page =ANL+SCP/1 in the project EPLAN_start, which you will create later.
Menu bar
The menu bar is located below the title bar. It contains the most important commands and dialog calls. In order to show all the menu items of a menu, left-click on the corresponding menu. Until you have opened a project and a page, you will not be able to select many of the menu items. These menu items are shown in a grayed-out view. Some menu items work like a switch, that is, they can be turned on or off. This applies particularly to the View menu for the Graphical preview menu item. If the option is switched on, then this is indicated with a preceding check mark . Example: The following example shows the "switched-on" menu item Graphical preview in the View menu.
Tip: In the Graphical preview, the pages you have selected in the Page navigator are shown in a reduced view. Using this window, you can, for instance, quickly search through all the pages of a project.
10
Getting to Know the EPLAN User Interface For menu items to which an icon is assigned, the corresponding symbol is highlighted with a frame in the switched-on state. This is the case, for instance, for the Page navigator, which you can call in the Page menu using the Navigator menu item (the icon in the switched-on-state: ). Example: The following illustration clarifies the example just explained using the "switched-on" Navigator menu item.
Note: If you can call a menu item using a key combination, that combination is shown next to the menu item. You have the option of changing the keyboard layout assigned by EPLAN and assigning your own key combinations to commands. The corresponding dialog can be found under the menu item Options > Keyboard shortcuts.
Popup menu
In many places in the program (in fields of windows or dialogs, in an opened page) you can open up a popup menu by right-clicking. The popup menu shows the most commonly used menu items for the object in question. If menu items are present in the popup menu of a field which go beyond the standard functions, you can see that from a "popup menu button" . This button is located above the corresponding field.
11
Getting to Know the EPLAN User Interface Example: The figure shows the popup menu for the Page navigator, opened using the popup menu button.
Toolbars
As standard, the toolbars are located below the menu bar and consist of buttons allowing you to directly call up the most important EPLAN functions. Here, too, you do not initially have all the buttons available. Example: The following figure shows you the Standard toolbar for an opened project.
12
Status bar
The status bar is located at the lower edge of the window. When you point the mouse at a menu item or a button in a toolbar, a brief informative text relating to the action called by this command is displayed here. If you have the cursor in an opened page, the status bar shows you information about the cursor position, grid, and logical status, along with data about the currently selected element, in some cases. Example: In the practice project you will create later, for instance, we have opened the page =ANL+SCP/1 and positioned the cursor on the coordinates X:176 / Y:216. On: 4.00 mm means that the Grid snap option is enabled and that the grid resolution for this page is 4 mm. This page is a Logic page (page type: Schematic multi-line) on a 1:1 scale.
3. Press [Ctrl] to avoid docking, and pull the Page navigator to a free position on the Windows Desktop. If the borders of the respective control element are displayed with a thick line, EPLAN positions the control element as an independent, undocked element on the Windows desktop. 4. Repeat this procedure for additional control elements. To do this for a toolbar or the menu bar, click on a "free" spot within the bar. Practice docking control elements, too. 5. To do this, click the title bar of the desired undocked control element (e.g., the Page navigator) with the left mouse button and keep the button pressed. 6. Pull the element to the desired position in the EPLAN main window.
14
Getting to Know the EPLAN User Interface To dock the undocked element to the border of the EPLAN main window (or the border of another dockable element), you must move the mouse pointer exactly to the border of the EPLAN main window. You can recognize this by the border of the element being displayed as a thin line. This will be a horizontal or vertical line, depending on whether you wish to position the control element at the top, bottom, left, or right. You can recognize the orientation from the thinly drawn preview rectangle. When the program is exited, EPLAN notes the last settings of these elements (docked, undocked, size, position) and restores them the next time the program is started. Example: The following illustration shows the EPLAN user interface reconfigured by docking and undocking control elements. Moreover, another toolbar ("Symbols") has been hidden and two more moved around inside the main window ("Graphics" and "Connection symbols").
15
2. Select the Standard toolbar, for instance, and click the check box in front of the toolbar name. EPLAN closes the popup menu and hides the toolbar. 3. Repeat the procedure and deactivate some more toolbars.
16
Getting to Know the EPLAN User Interface Practice unhiding toolbars, too. To do this, call up the popup menu again and click on the name of a hidden toolbar (e.g., Standard). Tip: For the hiding and displaying of toolbars, you also have the Customize dialog available. Call this dialog, for instance, using the Customize menu item on the popup menu, or using the menu items Options > Toolbars > Customize. You can also use this dialog to customize and extend the predefined toolbars and create your own toolbars.
Selecting workspaces
Once you have changed the EPLAN user interface to suit your needs, you can save this arrangement as a "workspace." In an EPLAN workspace, the size and position of the EPLAN main window are determined, as well as the position, size, and settings of dockable dialogs, menus, and toolbars. Using the workspace, you can quickly adapt the EPLAN interface to different tasks. We provide you with a few predefined workspaces which you can use as templates for your own workspaces. 1. Select the menu item View > Workspace. The Workspace dialog opens.
2. From the Scheme drop-down list, select the entry Connections as an example of a workspace. 3. Click [OK]. The interface changes you made will disappear. Besides the Page navigator, the main window now also contains the two windows Potentials and Connections. In these special navigators, all the potentials and connections of a project are shown. EPLAN Electric P8 Getting Started 17
18
Creating a Project
Creating a Project
Now that you have learned something about the operation of the user interface in the last chapter, you will learn how to create a project quickly and easily using the Project Wizard.
19
Creating a Project
2. In the Project name field on the first tab, enter the name for your first project. Name the project EPLAN_start. 3. Select a Template for the project. To do this, click the [...] button next to the field of the same name. If you don't select a project template here, you will not be able to perform any more steps in the Project wizard.
20
4. In the Open dialog, select the project template IEC_tpl001.ept. 5. Click [Open]. The Open dialog is closed and the name for the project template is accepted. 6. Select a storage location for the project. To do this, click the [...] button next to the field of the same name. The Browse For Folder dialog opens.
21
Creating a Project
7. By default, your projects are managed in the Projects directory in a "company folder" created during installation (Company code); in the illustration, this is the EPLAN Software & Service folder. Select this "company folder" and click on [Make New Folder]. A new folder is created below the currently selected "company folder", whose temporary name New Folder is highlighted with an edit frame. 8. Here, enter the name EPLAN_start and click [OK]. The Browse For Folder dialog is closed and you are returned to the Project wizard.
22
Creating a Project
9. Click [Finish].
The Importing project dialog opens. The Project wizard copies the template into the new project. This procedure may take some time. Then, the Create project dialog closes and the project EPLAN_start is displayed in the Page navigator. The projects form the first level in the tree. 10. Click on the plus sign in front of the project name in the tree view.
The tree is opened. In the level below the EPLAN_start project, the pages are now shown.
23
Creating a Project
You have just created a project using the Project wizard, which automatically has two pages. The selected project template enables hierarchically arranged structures for all objects in the project. It has a project structure already determined. Structure identifiers for the "higher-level function" and the "mounting location" are used to identify pages and devices. In the next chapter, you will learn how to assign structure identifiers to the automatically generated pages. There, you will also read how to open and create pages. Note: Once you are more familiar with EPLAN, you can use the different tabs of the Project wizard to change the predefined settings from the project template regarding structure, numbering, and properties. Using the Schematic tab, you can also determine structure identifiers for the first schematic page.
24
25
Opening Pages
1. In the tree view of the Page navigator, select page 1. 2. Select the menu item Page > Open. EPLAN opens the page in the graphical editor. The cover sheet of the project is shown. The page name is displayed not only in the title bar of the main window, but also as a tab under the graphic. In the Page navigator, you can recognize the opened page from the fact that the page name 1 is now in bold.
26
Tip: To open a page selected in the Page navigator, you can also doubleclick on the page or press the [Enter] key. Open the page 2 in the same way. This will automatically close the first page and display the empty schematic in the graphical editor. Tip: In EPLAN, you also have the option of viewing multiple pages on the screen at one time. For instance, select page 1 again, then from the popup menu of the Page navigator select the menu item Open in new window. EPLAN opens the page in another window of the graphical editor. For every opened page, a tab is shown below the graphical editor window. You can quickly switch between pages by clicking these tabs.
27
3. Change the value in the Full page name field. To do this, click the [...] button next to the field of the same name.
28
Opening and Editing Pages EPLAN opens the Full page name dialog. Here, you can enter the structure identifier and the name of the page (e.g., the page number).
4. Enter the value ANL into the Higher-level function field. 5. Enter the value DBT into the Mounting location field. 6. Click [OK]. The Full page name dialog is closed. The structure identifiers are accepted for the field of the same name in the Page properties dialog. 7. In the Page description field, enter the text Cover sheet. 8. Click [OK]. The Place identifiers dialog opens. Using this dialog, you can determine the order of newly created structure identifiers within a project. At this point, however, you do not need to worry about this dialog.
29
9. Click [OK]. The Place identifiers dialog is closed. In the Page navigator, the cover sheet now shows the structure identifier entered (=ANL+DBT/1). Repeat this action for the schematic page (page 2). In the Full page name dialog, as the structure identifier for the Higher-level function, enter the designation ANL again. However, as the Mounting location for the schematic page, enter the designation SCP and change the entry in the Page name field from 2 to 1. For the Page description for this page, the Page properties must still have the text Main circuit entered, and finally the position of the new structure identifier SCP must be confirmed with [OK]. Now all pages in the project have structure identifiers. To display all pages in the Page navigator, click the plus sign in the tree in front of the identifiers ANL, DBT, and SCP. You may first have to enlarge the Page navigator window a little before you can read all the page descriptions.
30
Note: If you have made a change during page editing (for instance, changed page properties, inserted graphical elements, etc.), then EPLAN saves these change immediately. There is no separate save necessary, and so there is no corresponding menu item in the program!
Creating a Page
For the schematic editing in a later chapter, you will need another page of the Schematic multi-line type. 1. In the tree view of the Page navigator, select the schematic page =ANL+SCP/1. 2. Select the menu item Page > New.
31
Opening and Editing Pages EPLAN opens the New page dialog. Most property fields already have values. EPLAN accepts the properties of the selected page and automatically suggests the next free page for the full page name.
3. Click on [Clear fields]. The contents of most property fields are deleted. The automatically suggested Page name and the prefilled Page type are kept. 4. In the Page description field, enter the text Control circuit. 5. Click [OK]. The new page is shown in the tree view of the Page navigator and opened in the graphical editor.
32
Closing a page
Since you don't immediately need the second schematic page, close it again. 1. Select the menu item Page > Close. The page =ANL+SCP/2 is closed. Tip: If you have the cursor in an opened page, then you can also close the page using the key combination [Ctrl] + [F4].
33
2. Select the project EPLAN-DEMO.elk. 3. Click [Open]. The page description is displayed in the Page navigator. 4. Click on the plus sign in front of the project name EPLAN-DEMO in the tree view. Then repeat this for the plus sign in front of the structure level CA1, then for the next to the structure level EAA.
34
Opening and Closing a Project The first section of the tree is opened. The pages are now displayed in the "lowest" project level.
5. Now open the first page (=CA1+EAA/1) of the demo project, for instance by selecting the tree view and then double-clicking. The cover sheet of the project EPLAN-DEMO is shown in the graphical editor. First, page through the pages of this extensive project. Tip: To open and close structure levels with subordinate levels, from the Page navigator you can also use the two menu items Open and Close from the popup menu. For instance, if you want to show all the pages of a project in the tree at once, then select the (closed) level with the project name and select the menu item Popup menu > Open (or press the [*] key on the numeric block of your keyboard).
35
36
Note: To page through the project pages, you can also use the keys [PgDn] / [PgUp] or the buttons / in the Page toolbar. However, if your cursor is located in the Page navigator, the keys will not page through the pages but will cause the cursor to jump to the bottom or top page shown in the tree view.
Creating a View
Using the page =EB3+ET1/1 now opened in the demo project, we would like to introduce you to a few functions which will be useful later when you create schematics.
37
These two options make it possible to orient elements directly to the grid points or element points when drawing. Please leave these options activated while creating the following schematic. The size of the grid used is stored as a page property and shown in the status bar. 1. Select the menu item View > Grid, to switch the grid display on. The use of grid snap is independent of the grid display options. If this view bothers you later when creating the schematic, then turn the grid display off in the same way.
38
Opening and Closing a Project 2. Left-click the mouse in the upper left corner of the schematic, and use the mouse to open an area which includes about a quarter of the schematic page. The area to be enlarged is delineated with a thick frame while it is being selected.
3. Click the left mouse button again. The selected area is displayed at maximum size.
39
If the entire page should be shown, simply press the key [3] (menu path: View > Zoom > 100%). Tip: You can also use an optional mouse wheel to zoom in EPLAN. By default, during scrolling the mouse wheel acts in the same way you are familiar with from other CAD programs. If you scroll up / down with the mouse wheel, the page is enlarged / reduced. In the settings, you also have the option of changing the scrolling behavior so that it matches the behavior of text editing programs. In this case, when you scroll with the mouse wheel, the visible section of the page is moved upwards or downwards.
40
2. Select the element by clicking on it. The color of the element changes again. 3. Select the menu item Edit > Delete (or press [Delete]). The element -Q1 is completely deleted. You can, however, use the Undo command to reinsert the element. 4. Then select the menu item Edit > Undo. Note: When editing elements in the graphical editor, besides the usual Windows operating methods (first select elements, then call command), in most cases the reverse order of operation (first call the command, then select elements) is also supported. Practice this once for the element -Q1 you just inserted. 1. Select the menu item Edit > Delete. In addition to the mouse pointer, two other symbols are also displayed. The box with the red X is the symbol assigned to the delete function, and the box with the dashed line stands for the area to be selected.
41
Opening and Closing a Project 2. Left-click the mouse button on the upper left of the element, and use the mouse to drag a frame around -Q1. The element -Q1 is removed. 3. This time, press the key combination [Ctrl] + [Z] to undo the Delete command again and to reinsert the element.
42
Opening and Closing a Project Example: You have just closed the demo project. Now click on the Project menu and select the EPLAN-DEMO entry. EPLAN opens the demo project again. After it opens, practice closing it again.
Now that you have looked at the complicated demo project in this chapter, in the next two main sections you will create a much "simpler" schematic.
43
Creating a Schematic
Creating a Schematic
In this chapter, you will begin with the creation of a simple schematic. To do this, first open if necessary the schematic page =ANL+SCP/1 in your practice project, with the description Main circuit.
What is a component?
A component is a graphical element for the representation of a function. It consists of a function and a symbol. The function contains the logical data and the symbol contains the graphical data. A component has a device tag, connection point designations, and so on.
44
Creating a Schematic
3. In the Current cursor position group box, for X: enter 40 and for Y: enter 248. 4. Click [OK]. The Coordinate input dialog is closed. Along with the cursor, EPLAN places the angle at the given position. The current cursor position is also shown in the bottom left corner of the status bar. 5. You can immediately insert more angles. To do this, call Coordinate input again, as shown above, and place more Angles (down, right) at the positions X:48 / Y:244 and X:56 / Y:240. 6. Then select Popup menu > Cancel action to terminate the action.
45
Creating a Schematic Note: In the entire practice project, we place the different schematic elements into precisely defined positions to make it possible to compare the results. To do this as described above you can use Coordinate input or position the elements at the given coordinates using the mouse or with the cursor keys. If you use the Coordinate input dialog to do so, each element is directly placed after confirming the coordinates with [OK]. If you position the element using the mouse or the keyboard, then after positioning you must still left-click the mouse or press [Enter] in order to place the element on the page. This kind of determination of insertion coordinates is not absolutely necessary when editing your own schematics. Tip: To call the Coordinate input quickly, you can also press the [P] key.
46
Creating a Schematic
3. On the Potential definition tab in the properties dialog, for the Name of potential, enter the value L1. EPLAN Electric P8 Getting Started 47
Creating a Schematic 4. In the Properties group box for the Potential type, select the value L from the dropdown list.
5. Click [OK]. The properties dialog is then closed. You can immediately insert more potential connection points. First position the connection points L2, L3 (both with potential type L) at the coordinates X:48 / Y:96 and X:56 / Y:96 and the connection point PE/N (with potential type Neutral) at the coordinates X:64 / Y:96. Then place two more potential connection points PE and N (with potential types of PE and N) in the schematic at the coordinates X:64 / Y:148 and X:76 / Y:136. After the symbols are placed, a different symbol variant must be selected in the properties dialog. To do this, click on the Symbol / function data tab in the properties dialog and, in the Variants field, select variant C.
48
Creating a Schematic
Finish this action by selecting the menu item Cancel action from the popup menu or pressing the [Esc] key. Tip: If there are different variants of a symbol (such as for a potential connection point), then you already have several possibilities during positioning to select between the different variants. For instance, if the symbol is hanging on the mouse pointer, you can press the [Ctrl] key and move the cursor in a circle. The various variants are displayed. Once you have decided on a variant, first release the [Ctrl] key, then click the left mouse button to place the symbol. A different way to page between the variants available consists of pressing the [Tab] key while inserting.
49
Creating a Schematic
7. Click [OK].
50
Creating a Schematic Repeat this action for the connection symbol T-node down (menu path: Insert > Connection symbol > T-node (down)), and insert two more T-nodes at the coordinates X:176 / Y:248 and X:192 / Y:244. No variant selection is necessary. Insert another Angle up, left as well (menu path: Insert > Connection symbol > Angle (up, left)), and place it at the coordinates X:76 / Y:120. If you do not want the insertion points to be shown, then select View > Insertion points again. Tip: For fast display and hiding of the insertion points, you can also use the [ i ] key.
Drawing rectangles
1. Select the menu item Insert > Graphic > Rectangle. The rectangle hangs on the mouse pointer. 2. Position the cursor at the coordinates X:28 / Y:84. 3. Click the left mouse button to determine the starting point of the rectangle. 4. Then move the cursor to the coordinates X:76 / Y:108 and click the left mouse button to place the end point of the rectangle. 5. Then select Popup menu > Cancel action to terminate the action.
51
Creating a Schematic Tip: You can also determine the exact data for the rectangle after drawing it. To do this, double-click on a line of the rectangle. In the properties dialog which appears, enter the Starting point and the End point of the rectangle into the fields of the same name.
Drawing lines
1. Select the menu item Insert > Graphic > Line. The symbol for the line hangs on the mouse pointer. 2. Position the cursor at the coordinates X:60 / Y:148. 3. Click the left mouse button to determine the starting point of the first line of the rectangle. 4. Then move the cursor to the coordinates X:72 / Y:148 and click the left mouse button to place the end point of the first line. 5. Repeat this action and position the starting point of the second line at the coordinates X:72 / Y:136. Place the end point of the second line at the coordinates X:84 / Y:136. 6. Then select Popup menu > Cancel action to terminate the action.
52
Creating a Schematic To "visually" highlight the action line, change the formatting properties of the lines inserted. 7. Double-click, for instance, on the "PE" line (the first line). The Properties dialog opens. 8. In the Properties dialog, switch to the Format tab. 9. Change the settings here. For instance, select a different Line thickness, Color, Line type, Pattern length, and/or Line end style.
10. Click [OK]. Repeat this action for the second action line. To differentiate the lines, select different formatting properties (e.g., a different color or a different line type).
53
Creating a Schematic
Selecting a symbol
In Symbol selection, you can select symbols from a tree or list view. In the tree view, symbols are divided neatly into different groups based on their function definitions. Here, you can page through the different groups until you find the symbol you want. Example: The following illustration shows symbol selection through the tree view for the first device to be inserted.
54
Creating a Schematic If you select a symbol in the tree, below the tree a symbol description of that symbol is displayed. On the right side in the dialog, the symbol selection presents you with a preview. Once you have selected the desired symbol in the preview, you can then accept it with a double-click. For the practice project, we are using a symbol selection from the list view. You can also select a symbol very quickly using direct entry in the list view. Note: The symbol selection via direct entry described below works only if you leave the columns of the list configured so that the name of the symbol is in the first column. 1. Select the menu item Insert > Symbol. The Symbol selection dialog is opened. 2. In the Symbol selection dialog, select the List tab. 3. To reduce the number of symbols shown, select a filter now. To do this, from the Filter drop-down list, apply the IEC symbols, multiline entry. 4. Select the Active check box to activate the filter settings. The various symbols are managed in "symbol libraries". Now the list only shows the multi-line symbols from the IEC_Symbol symbol library. 5. Enter Q1 into the Direct entry field. After you enter the first character, the cursor jumps to the first symbol whose name begins with that character, and selects it. The selected symbol is displayed in the preview window on the right side, with all existing variants. The first variant of each is selected in the preview window.
55
Creating a Schematic
6. In the list, select the three-pole switch Q1 and click [OK]. The symbol hangs on the mouse pointer and can be placed on the current page in the graphical editor. 7. Position the symbol at the coordinates X:40 / Y:196 in the schematic and then click the left mouse button.
Determining properties
After placing the switch on the page, the Properties (components) dialog opens. Some fields are already prefilled with entries. In EPLAN, devices are automatically numbered by default when inserted. This behavior is called online numbering. In the settings, you can deactivate online numbering and also change the predefined numbering format. 1. In the Properties (components): General device dialog, switch to the Switch / pushbutton tab.
56
Creating a Schematic The fields Displayed DT, Connection point designation, and Connection point description are already prefilled with entries.
2. As the new Connection point designation, enter 123456. To insert the character , which is used here to separate the individual connection points, press the key combination [Ctrl] + [Enter]. You can also select the menu item Line break from the popup menu. 3. Enter the value 16A into the Technical characteristics field. 4. In the Function text field, enter the text Plant on(Main switch). 5. Click [OK]. 6. Then select Popup menu > Cancel action to terminate the action.
57
Creating a Schematic You have now inserted a switch with three NO contacts into the schematic. -Q1 is shown as the displayed DT. In the schematic, you also see the connection point designations entered and the function text.
Tip: To call symbol selection quickly, you can also use the [INSERT] key or the button in the Symbols toolbar.
58
Creating a Schematic
Entries
59
Creating a Schematic No. Symbol description 4. Fuse, single-pole, general Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: Technical characteristics: 5. Rectifier, two-phase bridge, secondary 2 connection points Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: 6. Fuse, three-pole, general Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: 7. Power circuit breaker / motor overload switch with switch mechanism and line Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: Function text: 8. Power NO contact of a contactor Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation:
SL X:336 / Y:168 -K1 (12) QL3_1 X:336 / Y:196 (-Q2) (123456) Motor overload switch F3 X:336 / Y:220 (-F4) (123456) G22 X:176 / Y:140 (-V1) 24+0F1 X:176 / Y:168 (-F3) (12) 6A
Entries
60
Creating a Schematic For the other NO power contacts you have to insert, remove the suggested displayed DT -?K1, and don't enter any device tag there. For projects compliant with IEC standards, the DT is taken from the left. The behavior that occurs when components which have no DT of their own displayed and take their DT from a different component is called DT adoption in EPLAN. No. Symbol description 9. Power NO contact of a contactor Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: 10. Power NO contact of a contactor Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: 11. Three-phase asynchronous motor, one rotation speed Name in the symbol file: Coordinates: Displayed DT: Connection point designation:
M3 X:336 / Y:96 (-M1) (U1V1W1PE) SL X:352 / Y:168 56 SL X:344 / Y:168 34
Entries
Assign the motor a PE potential connection point as well. As already described in section "Inserting Potential Connection Points" on page 47, select the menu item Insert > Potential connection point and insert variant C of the symbol at the coordinates X:360 / Y:148. As Name of potential and Potential type, you must enter PE.
61
Creating a Schematic Then insert another Angle up, right (menu path: Insert > Connection symbol > Angle...) at the coordinates X:352 / Y:80 and an Angle up, left at the coordinates X:360 / Y:80.
Creating a Schematic 5. In the list, select the three-line switch X and click [OK]. The terminal symbol hangs on the mouse pointer and can be placed on the current page in the graphical editor. 6. Position the first terminal at the coordinates X:336 / Y:140 in the schematic and then click the left mouse button. The Properties (components): Terminals dialog opens. Here is where you determine the properties of the terminals. Terminals are also automatically numbered by default. Accordingly, the Displayed DT and Designation on the Terminal tab are already filled with the entries X1 and 1.
7. Click [OK]. The terminal with the displayed DT X1 is placed in the schematic.
63
Creating a Schematic 8. Position three more terminals at the coordinates X:344 / Y:140, X:352 / Y:140, and X:360 / Y:140. For the first two terminals, you can accept the predefined terminal designations 2 and 3, but for the last terminal change the designation to PE. 9. Finish the action by selecting the menu item Cancel action from the popup menu.
64
Creating a Schematic
3. In the Displayed DT field on the Terminal strip definition tab, enter the strip designation -X1 already assigned in the circuit diagram. 4. In the Function text field, enter the text Terminal strip motor. 5. Click [OK]. The terminal strip definition is inserted at the given coordinates. As terminal strip definition, the text -X1=Terminal strip motor is displayed. 6. Then select Popup menu > Cancel action to terminate the action.
65
Creating a Schematic
66
Creating a Schematic
7. Click [OK]. In the schematic, the cable definition line with the displayed DT W1 is shown along with the data entered. 8. Then select Popup menu > Cancel action to terminate the action. When drawing the cable definition line, a connection definition point is automatically set at each intersection of connections with the cable definition line. The cable conductors are determined via the connection definition points. You will only see these automatically generated connection definition points if you have activated the view of insertion points.
67
Creating a Schematic
Updating Connections
Connection lines generated by autoconnecting are at first simply graphical lines and not connections with data. For certain actions (e.g., closing a page, generating reports, etc.) the connections are first automatically updated. In doing this, new connections are generated based on the available information or existing connections are updated. The individual connection can get its data from project settings, potentials, or from a connection definition point. Since the connection data is not automatically updated for each action, we recommend manually updating before certain actions (such as the execution of check runs, or working in navigator dialogs). 1. Select the menu item Project data > Connections > Update. EPLAN regenerates all connections in the project. Note: You can tell if connections are up-to-date by looking at the right edge of the status bar: If the "#" sign is displayed there, the project has out-ofdate connections. If the "*" sign is displayed, the open page has out-ofdate connections.
68
Creating a Schematic
2. On the Path function text tab, enter the text Power supply 3ph / 400V. 3. Click [OK]. The path function text hangs on the mouse pointer. 4. Position the cursor at the coordinates X:40 / Y:64. 5. Click the left mouse button to place the text in the desired path. The path function text is placed at the given coordinates. 6. Then select Popup menu > Cancel action to terminate the action. Repeat this action to insert two more path function texts (Distribution 24 V DC at the coordinates X:176 / Y:64 and Conveyor belt at X:336 / Y:64). Note: Be sure when inserting path function texts that the insertion point of the text is aligned with the insertion point of the component which should receive the path function text. EPLAN Electric P8 Getting Started 69
Creating a Schematic
70
Creating a Schematic
5. In the Displayed DT field, enter the device tag L+. 6. Click [OK]. The interruption point is inserted at the given coordinates. 7. Position another interruption point with the designation L- at the coordinates X:192 / Y:96. 8. Then select Popup menu > Cancel action to terminate the action.
71
Creating a Schematic
72
Generating Cross-references
Generating Cross-references
In the previous chapter, you generated a schematic on the first schematic page of your practice project. In this chapter, you will complete the schematic on the second page, thus generating cross-references. EPLAN differentiates between different types of cross-reference. The program automatically inserts most of these cross-references automatically (online). Based on the practice project, you will get to know some of the most common cross-reference types. More detailed information on the different types of cross-reference can be found in the EPLAN online help.
73
Generating Cross-references Example: To do this, we will use an example (still to be created) from your practice project. The NC power contact -K1 on the first schematic page will later be cross-referenced to a coil which (then) is located on page 2 in column 2. In our example, the resulting cross-reference /2.2 will be shown under the displayed DT -K1.
By default, the cross-references receive a different color than the other elements displayed.
74
Generating Cross-references
3. Click [OK]. The interruption point L+ is inserted. The displayed properties are shown to the left of the insertion point.
75
Generating Cross-references 4. Position a second interruption point L- at coordinates X:36 / Y:100 and change the Property arrangement on the Display tab to Left, 0. The interruption point L- is inserted. 5. Then select Popup menu > Cancel action to terminate the action. The cross-references are displayed at both inserted interruption points beside the device tag.
The cross-references refer to the interruption points with the same displayed DT located on the first schematic page. On this page, too, corresponding cross-references are displayed at the interruption points.
76
Generating Cross-references For the second T-node, right, which you place at coordinates X:100 / Y:140, you must use the variant 1st target below, 2nd target right. To do this, after inserting, click on the insertion point of the T-node and then select the corresponding option in the T-node right dialog (see section "Inserting 'T-node' Connection Symbols" on page 50.). Or you can use the [Ctrl] key to rotate the symbol on the cursor and select the right variant that way.
Finally complete your second schematic page by placing the general devices. To do so, call up symbol selection (for instance, using Insert > Symbol) and then follow the description "Inserting General Devices" in the chapter "Creating Schematics". The following table lists the symbols to be inserted from the symbol library IEC_Symbol. Entries predefined by EPLAN are shown in parentheses.
77
Generating Cross-references No. Symbol description 1. Pushbutton, NC contact, general Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: Function text: 2. Emergency stop switch / Emergency stop pushbutton, NC contact, with turn-to-reset Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: Function text: 3. Pushbutton, NO contact, operated by pushing Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: Function text: 4. Lamp / indicator light, general Symbol name for direct entry: Coordinates: Displayed DT: Connection point designation: Function text:
H X:168 / Y:160 (-H1) (x1x2) Fault SSD X:100 / Y:160 (-S3) (1314) Motor on SONOT2 X:100 / Y:220 (-S2) (1112) Emergency shutoff SOA X:100 / Y:240 (-S1) (1112) Motor off
Entries
78
Generating Cross-references
Generating Cross-references The symbol hangs on the mouse pointer and can be placed on the current page in the graphical editor. 6. Position the coil at the coordinates X:100 / Y:120 in the schematic and then click the left mouse button. The Properties (components): General devices dialog opens.
7. In the properties dialog, switch to the Coil tab. 8. Enter the value -K1 into the Displayed DT field. 9. Apply the predefined Connection point designation A1A2. 10. Click [OK]. 11. Then select Popup menu > Cancel action to terminate the action.
80
Generating Cross-references Since we are using the same displayed DT for the coil as for the power contacts on the first schematic page, EPLAN automatically generates a contact image. This includes the connection point designations, the symbols, and the schematic positions of the contacts cross-referenced to the coil and is shown below the coil.
81
Generating Cross-references Tip: You can also apply the Displayed DT using a DT selection. To do this, click the [...] button located next to the Displayed DT field. The DT - selection dialog which then appears shows all the DTs present in the project which match the given function. Here you can apply an already existing DT with [OK] after selecting it, or use [Next] to generate a new DT. Example: The illustration shows you an example of DT - selection for the NO contact just inserted.
The cross-reference to the coil on the same page is displayed in the schematic immediately. For the contact to be shown in the contact image as well, you may need to update the view (menu path: View > Redraw).
82
Generating Cross-references
Generating Cross-references 6. Position the NC contact at the coordinates X:168 / Y:200 in the schematic and then click the left mouse button. The Properties (components): General devices dialog opens. 7. In the properties dialog, switch to the NC contact tab. 8. Enter the value -Q2 into the Displayed DT field. Or apply the displayed DT using DT selection. To do so, click the [...] button next to the Displayed DT field, then select the entry -Q2 in the DT - selection dialog which then appears. 9. Click [OK]. 10. Then select Popup menu > Cancel action to terminate the action. Now use symbol selection to insert another NO contact (symbol name for Direct entry: S; symbol number: 1). Place the NO contact at coordinates X:100 / Y:200 and enter -Q2 here, too, as the Displayed DT. Once the contact is placed, a corresponding cross-reference for the motor overload switch is shown on the first schematic page. You have now completed the creation of the schematic on the second page.
84
Generating Cross-references
On the motor overload switch itself, you see the contacts just inserted as a contact image. The cross-referenced contacts are shown as symbols on the action line of the motor overload switch. In addition, the connection point designations and the schematic positions of the contacts can be seen in the contact image. Open the first schematic page (=ANL+SCP/1) and look at the contact image.
For contacts to be shown in a contact image, appropriate display settings must be made for the contact image in the properties dialog of the motor overload switch. EPLAN Electric P8 Getting Started 85
Generating Cross-references Look at these settings in the motor overload switch. 1. Double-click in the schematic on motor overload switch Q2. The Properties (components): General devices dialog opens. 2. In the properties dialog, switch to the Display tab. The Contact image dropdown list shows the correct setting Motor overload switch for the contact image. This setting is preset by default during insertion of motor overload switches.
3. Click [OK]. Now you are finished with both of the schematic pages of your project. In the next chapter you will learn how to assign parts to the devices inserted.
86
Selecting Parts
Selecting Parts
In the previous two chapters, you created a simple schematic. Before you start with reports, for instance, you can automatically generate a parts list, you must enter parts for the devices inserted. The Parts tab is available in the property dialog of the components to do this. Here you can manually enter the parts or select them using part selection.
Assigning Parts
1. First, if necessary, open the first schematic page (=ANL+SCP/1) of your practice project. 2. Use View > Insertion points to show the insertion points of the elements inserted. 3. Double-click on the insertion point of switch -Q1. The Properties (components): General devices dialog opens.
87
5. Click [...] in the Part number field. The button appears once you click on the corresponding table cell in the Part number column. The Part selection dialog opens. Structurally, this dialog is exactly like Parts management. In the left half, the parts are shown in a tree or a list, where the tree structure is subdivided into multiple product supergroups (electrical, fluid, mechanical). In the right half of the dialog, you see the data belonging to the element or elements selected in the left window.
88
Selecting Parts
6. Select the entry Electrical engineering in the tree structure. 7. Click on the popup menu button from the popup menu. and select the menu item Expand
The structure of the Electrical engineering product group will be expanded. The parts numbers are shown on the lowest level in the tree.
89
Selecting Parts
8. To reduce the amount of data shown, select a filter now. To do this, click the [...] button next to the Automatic filter field. The Automatic filter dialog opens. The check box Identifier (Q) is already prefilled.
90
Selecting Parts 9. Click [OK] to confirm the setting. The Automatic filter dialog is closed. 10. In Part selection, select the corresponding Active check box for the Automatic filter so that the filter settings will be used. Now the parts matching the filter settings are shown in the tree structure.
11. In the tree from product group Power switchgear, select the part SIE.3LD2 504-0TK53. On the right side of Part selection, the parts data of the selected parts are now shown in the data fields. EPLAN Electric P8 Getting Started 91
Selecting Parts 12. Click [OK]. EPLAN opens the Conflict dialog. Whenever there is a difference between the data stored for the part and the data in the component, this dialog is called during Part selection.
13. For the property Characteristic, click the Option field and select the entry Retain from the drop-down list. This allows the characteristic 16A stored in the component (= Function) to be retained. 14. Click [OK]. The conflict dialog is then closed. The parts data selected is applied to the corresponding fields of the Parts tab, and the Number of units / quantity field is preset to 1.
92
Selecting Parts
Which data is shown to you on the right side of the tab depends on the setting in the dropdown list Category. If the entry Parts data is selected, then you will see data here such as the Part number, which is taken from Parts management and cannot be changed. If you selected Part reference data, then data is shown here, such as Service time which you can also store for a part in Parts management. In contrast to the "pure" parts data, however, you have the option of changing this data in the properties dialog and adapting it to the corresponding device in your own project. 15. Close the properties dialog with [OK]. The new parts data is written to the component.
93
Selecting Parts Note: If you mistakenly enter or select the wrong part number in the Part tab, you can delete it by selecting the corresponding table row and clicking on the (Delete) button. Repeat this action for the devices listed below. Assign the parts to each device based on the Part number listed. If the conflict dialog appears, then the properties stored in the component (= Function) will be kept. To do this, you must always select the Retain option for each property. Devices Displayed DT Part number Number of units / quantity
1x 1x
Page =ANL+SCP/1 Safety fuse Safety fuse Transformer Safety fuse Safety fuse -F1 -F2 -T1 -F3 -F4
PHO.0913032 PHO.0913032
SIE.4AV2400-2EB00-0A 1x PHO.0913032 SIE.5SG5700 SIE.5SE2310 SIE.5SH5010 SIE.5SH4362 MOE.046938 LAPP.0014 1043 (4G2,5) SIE.1LA7070-4AB10ZA11 PHO.3004524 PHO.0442079 1x 1x 3x 3x 3x 1x 1x 1x 3x 1x
94
Switch / pushbutton -S2 (emergency shutoff) Switch / pushbutton (NO) Coil Signal lamp -S3 -K1 -H1
After you have assigned parts to some devices in this section, you can start on reports in the next chapter.
95
Generating Reports
Generating Reports
Now that you have created a schematic in the previous chapters and assigned parts to the devices inserted, you can have EPLAN generate reports on the information in your schematic and automatically output different report pages.
96
Generating Reports 3. Click the [New] button. EPLAN opens the Select report dialog.
4. In the Select report type field, select the entry Terminal diagram. For this entry to be displayed, you must either enlarge the dialog or scroll through the entries using the scrollbar. 5. Click [OK]. The Filter / sorting - Terminal diagram dialog opens. Using this dialog, you can determine filter and sorting settings for the pages to be output. For your project, however, this is not required.
97
Generating Reports EPLAN opens the Terminal diagram (Total) dialog. Here you can specify how report pages will be sorted into the existing page structure.
7. Enter the value ANL into the Higher-level function field. Since the identifier already exists in your project, however, you can select it using a selection dialog. To do this, click the [...] button next to the Higher-level function field.
98
Generating Reports
8. In the dialog =Higher-level function (EPLAN_start) which appears, select the designation ANL and click on [OK] to return to the Terminal diagram (Total) dialog. 9. Enter the value ASW into the Mounting location field. 10. Click [OK]. The Place identifiers dialog opens. 11. Here, select the row with the designation ASW and move the row all button twice. This changes the way to the bottom by clicking the the order of identifiers created in the project and makes it possible for pages with the new identifier to be sorted in "after" the schematic pages.
99
Generating Reports
12. Click [OK]. EPLAN generates the page with the terminal diagram. All open dialogs are closed, and you return to the Reports - EPLAN_start dialog. 13. Now expand the tree on the left side. Select the Pages level and select the menu item Expand from the popup menu.
Under the report Terminal diagram, the report page =ANL+ASW/1 has been created for the terminal strip =ANL+SCP-X1. 14. Click [Close]. 100 EPLAN Electric P8 Getting Started
Generating Reports In the Page navigator, you now see the new page. You may first have to expand the tree and enlarge the window of the Page navigator before being able to see the new page =ANL+ASW/1 with the description Terminal diagram : =ANL+SCP-X1.
Note: A Page description like Terminal diagram : =ANL+SCP-X1 is created if, for instance, the check box Automatic page description is checked in the Terminal diagram (Total) dialog. (See also the illustration of the dialog in the action just completed.) By deactivating the Automatic page description check box, you also have the option of entering your own description for each report page. Open the page by double-clicking on it, and look at the terminal diagram in the graphical editor.
101
Generating Reports
102
Generating Reports
4. Select the Cable part check box. 5. Click [OK]. Now continue with the output of the other report pages.
103
Generating Reports
The identifiers of this page are applied to the Higher-level function and Mounting location fields, and for the Page name, the next free page is suggested. Instead of "2", enter the page number "10" into the Page name field. For the subsequent output of the Parts list, select the corresponding page =ANL+ASW/10 (cable diagram) in the tree. This time, enter the page number "20" into the Page name field. Then sort the Table of contents after the cover sheet by selecting the page =ANL+DBT/1.
104
Generating Reports After you have created the table of contents, the expanded tree structure in the Reports - EPLAN_start dialog looks like this:
The different reports are sorted in alphabetically ascending order (Cable diagram, Parts list, Table of contents, Terminal diagram). The yellow icon is used to mark all report types which represent overviews (e.g., parts lists, tables of contents, terminal diagram overview, etc.) The orange icon characterizes function-relevant report types (e.g., cable diagram, terminal diagram, terminal connection diagram, etc.). The level below that, marked in the tree with a yellow or orange icon with an opened drawer ( or ) is called a "report block" or just a "block". All report pages belonging to a particular element (e.g., a cable or a terminal strip) make up a single block. In your current practice project, there is only one report block for each report. If, on the other hand, there were two terminal strips -X1 and -X2 in the schematic, then, for instance, the terminal diagram pages for terminal strip -X1 would make up their own block, just as the terminal diagram pages for terminal strip -X2. The pages produced are shown on the lowest level in the tree. They have the same icon as in the Page navigator.
105
Generating Reports Quit the dialog using [Close], and look at the changed structure of your practice project in the expanded Page navigator.
Then open the newly generated pages and look at these pages in the graphical editor.
106
Generating Reports Example: For instance, the enlarged view of the table of contents (page =ANL+DBT/2) would look like this in the graphical editor.
With the generation of report pages, the creation and editing of your practice project is finished for now. In the following chapters, we will cover some additional topics, such as creating and inserting macros and searching project data. Then you will update the reports in your project using report templates. If you like, you can now print your project pages out. To do this, read the chapter "Printing a Project" on page 127. Naturally, you can also wait until later to print the project pages, for instance at the end of the sequence of chapters.
107
3. Position the cursor in the upper right corner of the schematic (e.g., at coordinates X:300 / Y:264), click the left mouse button, and drag the mouse to open an area enclosing the entire schematic section with the Path function text Conveyor belt. The area to be selected is outlined with a thick frame while it is being selected. 108 EPLAN Electric P8 Getting Started
4. Click with the left mouse button again (if the cursor is at the coordinates X:388 / Y:48, for instance). All objects in the area are selected and EPLAN opens the Save as dialog. In the Directory field, the preset default directory for macros is displayed.
109
5. In the File name field, enter Drive as the name of the macro. 6. In the Description field, enter Conveyor belt drive as the description for the macro. The text entered here is displayed in a comments field when inserting macros and simplifies the selection for you. 7. Click [OK]. The Save as dialog is closed. The macro is saved in the specified directory under the name Drive.ema.
110
Creating and Inserting Macros 1. Select the menu item Insert > Window macro. EPLAN opens the Macro file selection dialog.
2. Select the Preview check box. A graphical preview of the currently selected macro is displayed in the right side of the dialog. 3. Select the macro Drive.ema in the specified macro directory. The source project in which the macro originated is shown along with the description of the macro in a comment field below the preview. 4. Click [Open]. The macro hangs on the mouse pointer. 5. Position the macro at an arbitrary position in the schematic and click the left mouse button to place it. The Insertion mode dialog opens. In this dialog you define the manner in which devices are to be renumbered on insertion.
111
6. Select the Number option. This causes the devices inserted by the macro to be numbered automatically (online). For the counter of a DT, this takes the next free counter for each identifier into account. 7. Click [OK]. The Insertion mode dialog is closed and the macro is placed. Since the macro is still hanging on the mouse pointer, you could insert the macro again. 8. However, end the action using Popup menu > Cancel action. Tip: To position a macro during insertion, you can also use the following keys: [Y] + [X]: [Y]: [X]: The macro is fixed in its original position. The macro can be moved only horizontally from its original position. The macro can only be moved vertically from its original position.
112
Creating and Inserting Macros Example: For instance, on the example page (=ANL+SCP/3), the window macro Drive inserted there might look like this in the graphical editor.
Tip: Using the menu path Page > Page macro > Insert, you can insert either a window macro or a page macro. In the Select macro dialog which appears next, you must then select the entry Window macro (*.ema) as the File type. As usual when inserting page macros, this creates a new project page.
113
114
3. In the Search in group box you can specify the objects in which you would like to search for the term. Check the DT / designation check box here. 4. In the Search location group box, you can exclude certain page types from the search. Here, check the Entire project: EPLAN_start option along with the Logic pages and Graphical pages check boxes. 5. You also have the option in this dialog of entering the results of a search into one of two possible results lists. Select the List of results 1 option. 6. Click [OK].
115
Finding and Replacing Identifiers The Find dialog is closed. EPLAN begins the search, opens the Search results dialog, and then displays the entries found.
All fuses in the project are listed in the dialog in tabular form. If you cannot see all the entries, drag the dialog to enlarge it and adjust the width of the individual columns if necessary. Below the listed search results, EPLAN shows you a text field with the page on which each selected object is located. Tip: In the Search results dialog, if you select an object located on a project page, the Graphical preview shows the corresponding page. The position of the object is highlighted in the preview with concentric circles.
116
Finding and Replacing Identifiers Example: The following illustration shows the Graphical preview after the search result with the value -F1 has been selected in the results list.
Tip: To call the Find dialog quickly, you can also use the key combination [Ctrl] + [F] or the button in the Find toolbar.
117
Finding and Replacing Identifiers 3. Remove the 1 in the Find what field and enter the value -CB into the Replace with field. 4. Click [OK]. In the Search results dialog, the identifier -F is replaced by the new value -CB. In the schematic, too, all selected devices are renamed.
118
Finding and Replacing Identifiers Tip: The popup menu of the Search results dialog includes additional very useful program functions for the finding and editing of project data. For instance, you can use the menu item Go to (graphic) to jump from a selected object in the results list to the corresponding position in a project page. Using the menu item Edit in table, multiple selected objects can be edited together in a subsequent dialog. In this way, for instance, you could rename the DTs of the selected devices.
119
5. Click [OK]. The Search results dialog shows you two entries for the search term Conveyor belt.
6. Select the second entry in the list. If you have opened the graphical preview, you will see that the second entry is a path function text which you inserted with the window macro on the page =ANL+SCP/3. 120 EPLAN Electric P8 Getting Started
Finding and Replacing Identifiers 7. In the popup menu, select the menu item Properties (or doubleclick). The Properties dialog opens. On the Path function text tab, the text Conveyor belt is already selected.
8. Enter the new text New drive here directly. 9. Click [OK]. In the results list and in the schematic on the page =ANL+SCP/3, the new path function text now appears. Before you print out your whole project, you should first complete and update your reports. How you do this is described in the next chapter.
121
Updating Reports
1. In the tree view of the Page navigator, select the structure identifier level =ANL (or select the name of your practice project directly). 2. Select the menu item Utilities > Reports > Update. All report pages below the structure identifier level =ANL are updated. If you then look at the pages of your practice project, you will see that the overviews in the project (Table of contents, Parts list) have been updated. If you had made changes in the project to terminal strip X1 or cable W1 (for instance, specifying a different function text, a new target, etc.) then these changes would have been included in the update. For the two new devices terminal strip X2 and cable W2 an update of the previously generated report pages is not sufficient. Instead, you must generate a terminal diagram for X2 and a corresponding cable diagram for W2. You could proceed as described in the chapter "Generating Reports" on page 96, and output new report pages in that way. But EPLAN also provides you with the possibility of using existing reports to generate report templates. Then you can report on the entire project based on those templates.
122
4. Repeat this procedure for the report Cable diagram. To do this, select the report block =ANL+SCP-W1 and again select Popup menu > Create report template. 5. Change to the Template tab. 6. Now expand the tree on the left side. Select the Templates level and select the menu item Expand from the popup menu. In the tree structure, the templates created are shown. EPLAN Electric P8 Getting Started 123
Completing and Updating Reports 7. Now, if you select the template All under Cable diagram, for instance, the table on the right side will show the specified properties of this template. Here you might change the Start page for your cable diagram pages.
8. Click [Close].
124
Then page through your project and look at the new and changed pages in the graphical editor. In the following chapter, you will conclude by learning how to print the pages of your projects.
125
Completing and Updating Reports Example: For instance, the enlarged view of the table of contents (page =ANL+DBT/2) would look like this in the graphical editor after the reports are generated for the project.
126
Printing a Project
Printing a Project
To conclude this getting started guide, print all the pages of your project. In EPLAN, you naturally also have the option of printing a single page or any arbitrarily selected pages of a project. The print can be in black and white or in color, and can either be sent to a printer or to a file. 1. In the tree view of the Page navigator, select your project EPLAN_start. 2. Select the menu item Project > Print. The Print dialog opens.
3. In the Printer box, select the desired printer from the drop-down list. 4. If you have accidentally selected only one page in the Page navigator or if the cursor is located on an opened page, then by default only the current page will be printed. You can tell this by the fact that in the Page range group box, the Entire project option is not activated. In this case, activate this option. 5. Click [OK]. EPLAN Electric P8 Getting Started 127
Printing a Project All pages of the projects will be printed. Note: Using the Print preview, which you can call from the print dialog using the button of the same name, you have the option of checking the pages to be printed before they are actually printed. If the pages shown don't match your expectations (if a print margin is missing, for instance), you can close the preview window and change the print settings if necessary in the Print dialog using the [Settings] button.
128
Printing a Project
129
Printing a Project
130