Snatch Block Visual
Snatch Block Visual
Snatch Block Visual
Snatch Block
4.0 t N/A
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
4.0 t N/A
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
4.0 t N/A
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
SL 9881
Snatch Block 1 Manufacture Year of
(41428616)
Size: 254 mm. Name Manufacturing
Wire line: 13 mm-14 mm.
CROSBY 10-Sep-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
SL 9882
Snatch Block 1 Manufacture Year of
(41428619)
Size: 254 mm. Name Manufacturing
Wire line: 13 mm-14 mm.
CROSBY 10-Sep-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
235 AJ
Snatch Block 1 Manufacture Year of
(41434822)
Size: 14" Name Manufacturing
Wire line: 5/8"
CROSBY 18-Jan-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
237 AJ
Snatch Block 1 Manufacture Year of
(41326529)
Size: 14" Name Manufacturing
Wire line: 5/8"
CROSBY 18-Jan-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
234 AJ
Snatch Block 1 Manufacture Year of
(41326523)
Size: 14" Name Manufacturing
Wire line: 5/8"
CROSBY 18-Jan-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
232 AJ
Snatch Block 1 Manufacture Year of
(41431949)
Size: 14" Name Manufacturing
Wire line: 5/8"
CROSBY 18-Jan-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Snatch Block
12.0 t N/A
236 AJ
Snatch Block 1 Manufacture Year of
(41434847)
Size: 14" Name Manufacturing
Wire line: 5/8"
CROSBY 18-Jan-2015
Applicable Reference Standards : BS EN 13157
Applicable Reference Regulations: SWIM
Colour Code: Green till the end of September, then Orange
NDT Details (if Any): N/A
Test Equipment Details: N/A
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above: None
Particulars of any tests carried out as part of the examination(If none state NONE) Visual
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA & NDT Level II
Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz
This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018