HV Cable Accessory FOR 66 550kV: High Efficient, Green Energy Solution
HV Cable Accessory FOR 66 550kV: High Efficient, Green Energy Solution
HV Cable Accessory FOR 66 550kV: High Efficient, Green Energy Solution
FOR 66~550kV
High Efficient, Green Energy Solution
THE WORLD
002 LS cable & system
BEST CABLE
SOLUTION
LEADER
LS Cable & System supplies various cables and materials used
for power grids and communication networks around the world across
all industries providing its top class technology and excellent quality.
The company has also developed state of the art products, such as superconductors,
HVDC and submarine cables that will lead the future energy industry.
cable system have been supplied to energy agencies, heavy electrical equipment manufacturers and level of quality to address the ever-changing demands in eve- Pro-Con Gas Insulated Terminations 11
005
008 The way we walked
Contents
L S E x t r a H i g h V o l t a g e A c c e s s o r y f o r 6 6 ~ 5 0 0 k V S a f e t y a n d E f f i c i e n c y A l w a y s L e a d t o R i g h t S o l u t i o n
The termination is filled with polybutene oil up to optimized maintenance expenses. without oil reservoir for maintenance
level where the electric stress is substantially reduced thereby free. The dry type could be easily installed in any position. The
not requiring an oil reservoir or monitoring system as addition- SVL(Sheath Voltage Limiter) can be installed to protect epoxy
al maintenance expenses. The termination base plate and the insulating plate from switching impulse. The main insulation
cable’s metallic sheath are electrically insulated from the sup- components are fully examined and tested in the factory.
porting structure by means of stand off insulators designed to Design and scope of supply are fully complying with IEC 60859
withstand both mechanical and electrical stresses in services. and IEC 62271-209 and possibly adjusted to various needs of
Either porcelain or polymer hollow insulator can be supplied “D” customers such as plug-in type. They are currently available to
depending upon requests. They are currently available to the the maximum allowable cable conductor size of 2500mm2 “D”
NOS
maximum allowable cable conductor size of 2500mm2
Insulator Type “L” Creepage Distance “L” Base Plate Cable size Insulator Type according to Insulator Size “L” Base Plate Cable size
Type Operating voltage Special Add-on Type Operating voltage Special Add-on
(mm) (mm) “D” (mm) NOS (mm) IEC 62271-209 (mm) “D” (mm) (mm)
LSPA-01 1500 4000 Φ490 72.5 ~ 145kV LSPG-01 583 Φ270 72.5 ~ 100kV 200SQ ~
200SQ ~ Fluid filled 2500SQ
LSPA-03 2000 6000 Φ490 150 ~ 170kV LSPG-03 757 Φ320 123 ~ 170kV
4 2500SQ Dimension
LSPA-05 2400 7200 Φ490 150 ~ 170kV LSPG-05 (Figure.3) 960 Φ582 245 ~ 300kV 300SQ ~2500SQ
*OP : *OP :
LSPA-07 2700 8400 Φ600 245 ~ 300kV 300SQ ~ LSPG-07 1400 Φ640 362 ~ 550kV 500SQ ~2500SQ
Porcelain Embedded Conventional Embedded
LSPA-09 3500 11500 Φ700 245 ~ 300kV 2500SQ LSPG-09 310 Φ270 72.5 ~ 100kV
Fiber optic box 200SQ ~ Fiber optic Joint
Dry 2500SQ box
LSPA-11 4300 13000 Φ800 6 330 ~ 420kV LSPG-11 470 Φ320 123 ~ 170kV
500SQ ~ Dimension
LSPA-13 5000 16300 Φ800 330 ~ 420kV 2500SQ *AH : LSPG-13 (Figure.5) 620 Φ475 245 ~ 300kV 300SQ ~2500SQ
LSPA-15 5000 18700 Φ900 8 500 ~ 550kV Arching horn LSPG-15 960 Φ640 362 ~ 550kV 500SQ ~2500SQ *SL :
for Protecting Surge limiter
LSPA-02 1500 4000 Φ490 72.5 ~ 145kV LSPG-02 583 Φ270 72.5 ~ 100kV 200SQ ~
insulator for protecting
200SQ ~ Fluid filled 2500SQ
LSPA-04 2000 6400 Φ490 150 ~170kV LSPG-04 757 Φ320 123 ~ 170kV
4 2500SQ Dimension
LSPA-06 2400 7700 Φ490 150 ~ 170kV *SB : LSPG-06 (Figure.3) 960 Φ582 245 ~ 300kV 300SQ ~2500SQ *SB :
LSPA-08 2700 8900 Φ600 245 ~ 300kV 300SQ ~ Connection by LSPG-08 1400 Φ640 362 ~ 550kV 500SQ ~2500SQ Connection by
Polymer Plug-in
2500SQ shear bolt shear bolt
LSPA-10 3500 11700 Φ700 245 ~ 300kV LSPG-10 310 Φ270 72.5 ~ 100kV 200SQ ~
Dry 2500SQ
LSPA-12 4300 14000 Φ800 6 330 ~ 420kV LSPG-12 470 Φ320 123 ~ 170kV
500SQ ~ Dimension
LSPA-14 5000 17000 Φ800 330 ~ 420kV LSPG-14 (Figure.5) 620 Φ475 245 ~ 300kV 300SQ ~2500SQ
2500SQ
LSPA-16 5100 18000 Φ900 8 500 ~ 550kV LSPG-16 960 Φ640 362 ~ 550kV 500SQ ~2500SQ
* Dry flexible Type is order made designed upon request of installation conditions * Non-IEC Type for existing GIS is order made designed upon request of installation conditions
10 11
L S E x t r a H i g h V o l t a g e A c c e s s o r y f o r 6 6 ~ 5 0 0 k V S a f e t y a n d E f f i c i e n c y A l w a y s L e a d t o R i g h t S o l u t i o n
* Non-EN Type for existing Transformer is order made designed upon request of installation conditions * Shrink Tube Type is order made designed upon request of installation conditions
12 13
L S E x t r a H i g h V o l t a g e A c c e s s o r y f o r 6 6 ~ 5 0 0 k V S a f e t y a n d E f f i c i e n c y A l w a y s L e a d t o R i g h t S o l u t i o n
[AL-CU connector]
[Oil filled Stop Joint]
Type Outer casing Type Max Operating voltage Cable size Special Add-on Type Outer casing Type Max Operating voltage Cable size Special Add-on
(mm) “D” (mm) (mm) (mm) “D” (mm) (mm)
14 15
L S E x t r a H i g h V o l t a g e A c c e s s o r y f o r 6 6 ~ 5 0 0 k V S a f e t y a n d E f f i c i e n c y A l w a y s L e a d t o R i g h t S o l u t i o n
voltage up to 1200kV. It is required to assemble with epoxy condenser and insulation paper,
aluminum foil to reinforce the insulating performance. LS supply the assembly manual for
using the test terminations.
[Product Specification]
• Customized design of test voltage, interface construction
[Buried Type] [Gantry Mounted Type]
• L-series: Making closed circuit to enable heating cycle voltage test
(Applying voltage to test loop under flowing current)
• V-series: Convenient preparation for impulse / AC voltage test
• V-1200: Enabling electrical performance test for breakdown test
[L-series test termination]
LSRO01 Link Box for Earthing 1-1WAY L-300 66 ~ 132kV 300kV 650kVp
Heating cycle voltage test Test termination
(Type test / EQ test )
LSRO02 Link Box with SVL 1-1WAY L-700 220 ~ 500kV 600kV 1,550kVp Adapters
Gantry Mounted/
Termination Single Core
Buried
LSRO03 Link Box for Earthing 3-1WAY V-200 66 ~ 132kV 200kV 650kVp
LSRO04 Link Box with SVL 3-1WAY 3kV~21kV V-300 220 ~ 275kV 300kV 1,050kVp Two terminations
Electrical sample test (Voltage part, End part)
(AC voltage / PD test / Impulse test)
Link Box for Adapters
LSRO05 3-1WAY V-700 345 ~ 500kV 600kV 1,550kVp
Cross-Bonding
* Include Surge voltage limiter in the link box of the is order made designed upon request of bonding cable system
16 17
L S E x t r a H i g h V o l t a g e A c c e s s o r y f o r 6 6 ~ 5 0 0 k V S a f e t y a n d E f f i c i e n c y A l w a y s L e a d t o R i g h t S o l u t i o n
Training Curriculum
Training Course Training plan for Jointer course Training plan for Engineer course
Whatever trainee’s level, LS can do the planning for the graded training course as per participant’s group, level and experience. To improve technician’s skill & knowledge for EHV System To improve engineer’s knowledge & project management
- Understand general theory of Extra High Voltage cable system - Understand intensive theory of extra EHV cable system
Trainee - Be familiar with the Drawing, Manual and Check List Purpose - Be familiar with the Drawing, Manual and Check List
Course Duration - Have the skill for treatment Cable and Accessories - Have the capability for risk & quality management
Group Level
- Fool proof through hands on practice
Assistant Jointer Jointer course III 4 weeks
[EPC Partners] [EPC Partners]
Jointers Jointer Jointer course II 3 weeks The local jointers who will install LS cable accessory Target The local engineers who will manage PIT using LS Product
Chief Jointer Jointer course I 2 weeks [Client & End users] The Maintenance & Operation technicians who Group [Client & End users] The design engineers, project managers,
employ Power electric utilities & company consultants who employ Power electric utilities & company
Site Engineer Basic engineer course 1 week
Engineers
[EPC Partners]
Project Manager Advanced engineer course 2 weeks [EPC Partners]
Be a certified jointer by LS to perform jointing work at site
[Training facility of LS Learning Academy] Expected Be a LS local partners as distributer or installer.
[Client]
Result [Client]
Be a skillful technician to perform jointing work by themselves
To be an expert for the extra high voltage cable system
in case of emergency or repairing works.
Preview Perform Assess Certify
• Trainees Level • Theoretical lecture • Knowledge & Skill • By voltage grade • Understanding for the EHV Products and Installation • Understanding for EHV Products, Engineering and Installation
• Location, Duration • Hands on practice • Competence • Scope of work • Hands on practice for splicing & terminating work • Watching on splicing & terminating work
Training
• Training Contents • OJT (Site Training) • Electrical Test • Expiration date • How to do on site test • Maintenance work
Subject
• On the job training at actual installation site • On the job training at actual installation site
• Cable & Accessory manufacture line tour • Cable & Accessory manufacture line tour
[Training Course Preview]
Training Facility
The new-built training facility specialized for the practical training course enables the realization of key performance on site.
[Cable Accessory Show Room] [Practice Room for the Splice] [Pit for the Termination]
18 19
L S E x t r a H i g h V o l t a g e A c c e s s o r y f o r 6 6 ~ 5 0 0 k V S a f e t y a n d E f f i c i e n c y A l w a y s L e a d t o R i g h t S o l u t i o n
[Hydraulic Pressure Pump set] [Electric torque wrench] [Sleeve Inserting tool] [Belt Sander]
ALL
[Insulation stripper] [Grooving Tool] [Edge Beveling Tool] [AL Sheath Cutter]
JOINT
Tools Specification
Item Specification Applied for
Sleeve Inserting tool Grooving Tool
(Manual with chain block) 700 kgf pump Apply 100 ~ 150Ton Head
Hydraulic Pressure Pump
100/150 Ton Head depend on conductor & Insulation
Electric torque wrench 150 ~3 00 Nm torque For all kinds of termination and joint
Sleeve Inserting tool 70 kg, manual type For all kinds of joint
General Tools
The general tool would be used conventional however If required, LS can provide advanced one as below. S size : Φ50 ~ 90 diameter
Grooving Tool 4.2 kg
L size : Φ90 ~ 130 diameter
Insulation stripper AL Sheath Cutter Belt Sander Edge Beveling Tool Belt Sander 2.8 kg Sand paper : 50W * 650L, #220 ~ 320
20 21
RESEARCH Conducting research forsustainable
growth and customer’s future
& The electrical power and ICT industries will play key roles in the future of the energy
industry. In order to take the lead, these industries will require state-of-the-art tech-
DEVELOPMENT
nology to transmit large quantities of electric power over long distances without loss
and innovative solutions for transmitting large amounts of data faster and reliably.
LS Cable & System focuses on R&D for securing core technologies for the future and
continuously implements them. With increasing consumer demand to supply power
to households and business that are integral to growth and production across the
world, LS Cable & System is at the forefront of research and development on the fu-
ture of the cable industry continuing its customer focus and manufacturing products.
Australia
LSCAU SYDNEY
Gumi Plant Indong Plant Donghae Plant LSHQ(Yichang) LSCW(Wuxi) LS-VINA(Haiphong) LSCV(HO Chi Minh) LSCI(Bawal) LSCUS(Tarboro) LS EV Poland./LSCP
EHV / MV / LV cable Optical fiber Submarine cable EHV / MV / LV cable Industrial devices cable EHV / MV / LV cable MV / LV cable EHV / MV / LV cable MV / LV cable (Dzierzoniow)
UTP, Coaxial cable Optical cable Industrial specialty cable Industrial specialty cable Automotive cable SCR, ACSR UTP, Optical cable Coaxial cable Control, Instrument cable Automotive battery components
SCR, Magnet wire Harness & module Overhead cable Overhead cable Overhead cable Optical cable
Overhead cable, Bus duct Aluminum, Bus duct