Bus Ethernet Gateway Installation Guide: Supported Model
Bus Ethernet Gateway Installation Guide: Supported Model
Bus Ethernet Gateway Installation Guide: Supported Model
WARNING! Disconnect the power for all lines feeding into the panel before
installing this device.
2
ATTENTION! Assurez-vous que tous les disjoncteurs d’alimentation dans
le panneau sont éteints avant d’installer l’appareil.
3
IMPORTANT! Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See “Troubleshooting.”
5 4
Requirements and Specifications 1 2x RS-485 pluggable connectors
2 Link/Activity LED
Prior to installing this product, ensure that the Control4 5-Slot or 2-Slot Panel or 3 Reset button (recessed)
the cabinet to house the gateway has been installed.
4 Module Status LED
5 Module ID button
Pre-Installation Instructions
Before You Install in a Control4 Panel
1 Use Composer Pro to add the Bus Ethernet Gateway to a project, define its
location in a panel, and print the panel report. See the Composer Pro User
Guide for details.
2 Install the panel following the instructions in the 5-Slot and 2-Slot Panel
Installation Guide.
Before You Install in a Third-Party DIN Rail Panel NOTE: To remove the module, push the module toward the bottom, rotate
the module up, and lift it off.
1 Install the third-party panel according to the third-party instructions.
3 On the top of the Bus Ethernet Gateway, connect the Ethernet CAT5 cable to
the RJ-45 port.
Installation Instructions 4 Install the other modules in the panel as defined in their respective installation
guides.
Install in a Control4 Panel
1 With the Ethernet port facing right, hold the Bus Ethernet Gateway upright
and angle it to the right so that the right side of the module fits onto the rail
Wiring Diagrams
in the panel.
For information about bus wiring details, refer to the Keypad Bus Wiring Guide.
2 With the right side already in place, push forward on the left side of the Bus
Ethernet Gateway to snap it onto the rail (see Figure 2).
Figure 2. Snap on the Bus Ethernet Gateway - Control4 Panels Operations and Configuration
Button Taps
LED Indicators
The indicator lights on the front of the Bus Ethernet Gateway communicate the
status of the device.
NOTE: To remove the module, push the module toward the left side, pull
out from the left side., and remove it from the right side. Indicator Color Status Notes
Status Blue Power On
Install in a Third-Party Panel Black No Power
Link/Activity Solid Green Link
1 With the Ethernet port facing up, hold the module lengthwise and angle it up
so that the top side of the module fits onto the rail. Orange Activity
2 With the top side already in place, rotate the module down to snap it onto the Flashing Green Firmware is updating Flashing gets faster
rail (see Figure 3). as the
update proceeds
Figure 3. Snap on the Bus Ethernet Gateway - Third-Party Panels Reset Button
NOTE: The Reset button is recessed and must be pressed using a paper
clip or similar device. A single click of the Reset button is equivalent to
powering the Bus Ethernet Gateway off and back on.
Regulatory/Safety Compliance
To review regulatory information for your particular Control4 products, see
the information located on the Control4 website at: http://www.control4.com/
regulatory/.
Warranty
For complete warranty information, including details on consumer legal rights as
well as warranty exclusions, review the Warranty card or visit www.control4.com/