Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

J Series: Rectifier Module

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

J Series

Rectifier Module
Overview

Eltek rectifier modules provide industry-leading power density


and efficiency in 1 or 2 RU footprints. With a wide range of
power ratings and form factors, there is an Eltek rectifier for
your power needs. Versatility, scalability, and “hot swap”
capability make for optimal system design and cost-effective
deployment—from initial install to future upgrades.

The Eltek Difference Features


Optimization o Small 1RU footprint
Eltek rectifiers are optimized for the demanding o 48V output
power and power conversion needs of wireless o Output power up to 1680W
communications, enterprise and broad-band access
o Conversion efficiency of 91%
equipment.
o Operating temperature range: from -40°C to
Small size, big power +65°C
At only 1RU in height and 10” in depth, Eltek J-series o Universal AC input
rectifiers can provide up to 1,500 Watts of power. The
small size frees up space to reduce system size or
o Power factor correction
incorporate additional electronics. o Hot-pluggable/hot-swappable
o Redundant parallel operation
Industry-leading efficiency
Industry-leading efficiency reduces the thermal load, o Active load sharing
thus improving overall system reliability and o Advanced internal monitoring
availability. o Front status LEDs
Flexibility o NEBS Level 3
J-series rectifiers are designed to operate in Eltek’s J o UL Recognized
Front Wire and J Rear Wire DC Power Systems. They o VDE Certified
are versatile modules that can operate either as
o CE Mark
standalone units or with a system controller.
o RoHS EU Directive 2002/95/EC compliant
o GR-3108 compliant
o MTBF of 420,000 hours at 40°C

www.eltek.com Copyright © 2012 Eltek Doc. No. 2046924, Issue 2


Doc. No. 2046924, Issue 2
J Series Rectifier Module Published 20-Mar-12

Additional Technical Specifications


AC Input
J1500A1*
J SERIES J0600A1 J1000A1 NOTES
@low line @ high line
Startup Voltage. Unit operates to 5V below startup
Input Voltage (min) 90 Vac 90 Vac 90 Vac 180 Vac
voltage
Steady State Voltage. Unit with stands short
Input Voltage (max) 264 Vac 264 Vac 170 Vac 264 Vac
duration excursions to 300Vac.
Input Frequency (min) 47 Hz – 63 Hz
Input Current (max)…
@ 100 Vac (amps) 9.8 12.9 16 - 56 VDC and rated current
@ 120 Vac (amps) 6.4 10.6 13 - 56 VDC and rated current
@ 180 Vac (amps) 4.2 7.0 - 10.4 56 VDC and rated current
@ 208 Vac (amps) 3.7 6.0 - 8.9 56 VDC and rated current
Inrush Current (max) 30 amps peak Excludes X caps in the EMC input filter.
Power Factor .99

DC Output
J1500A1*
J SERIES J0600A1 J1000A1 NOTES
@low line @ high line
Vo Set Point
42/48/59 Vdc
(min/typ/max)
Regulation (min/max) ±1% Total regulation line, load, aging & temperature
42V - 56V – Full rated current.
Output Current
0/12 0/20 0/25 0/30 56V - 59V – 85% rated current based on rectifier
(min/max amps)
setpoint.
Output Power
672 1120 1400 1680 56 Vdc and full rated current
(watts max)
Current Limit
105% to 110% of maximum rated load
Setpoint
40 mV rms typical (10kHz to 20MHz)
Output Noise* 32 dBrnc (measured w/o external battery)
250mV P-P (10 Khz to 20 Mhz)
Output Rise Time*
100/400 msec Measured at 10 – 90% of final output level
(min/max)
Change in output voltage within 10 msecs after a
Dynamic Response* 4%
10 to 100% load step change
Measured from application of valid AC voltage to
Turn On Delay* 3.5 sec
regulation set-point
Backup Over-voltage
60 Vdc
Protection
Load Sharing ±5% Percentage of full load
Reverse Output
0.5 amps Internal reverse protection is provided.
Current (max)
Efficiency 89% 91% 56 VDC and rated current
*Compliant from -20°C to +50°C

Typical specifications, unless otherwise stated


Nominal line: 230 VAC
Nominal setpoint: 48 VDC
Nominal load: 100% of rated current
Specifications subject to change without notice

PAGE 2 OF 6
Doc. No. 2046924, Issue 2
J Series Rectifier Module Published 20-Mar-12

Additional Technical Specifications


Auxiliary Output
PARAMETER J0600A1 J1000A1 J1500A1 NOTES
Output 1*
Nominal Voltage 12V
Vmin/max 10.5 / 14
Source Current Rating**
0 / 500mA
(min/max)
Current required for internal controls when AC is
Sink Current (max)** 100mA
not present
Output 2*
Nominal Voltage 5V
Vmin/max 4.75 / 5.25
Source Current Rating**
0 / 250mA
(min/max)
NOTE: *Output 1 and 2 operates independent of main DC output and is referenced to Vout-
**Auxiliary bias current not to exceed Aux 1 Current + (2 X Aux 2 Current) = 500mA

Physical
PARAMETER J0600A1 J1000A1 J1500A1 NOTES
Depth 254.0mm (10")
Height 42.7mm (1.68")
Width 101.7 mm (4.00”)
Weight 2.23kg (4.92lbs)

Environmental
PARAMETER MINIMUM MAXIMUM UNIT NOTES
Storage Temperature -40 85 °C
Full power is -40°C to +50°C; output power de-
Operating Temperature -40 65 °C
rates 2%/°C above 50°C.
Humidity 5 95 % Relative Humidity Non Condensing

For operation above 8000' , maximum


Altitude -200 8000 Ft
temperature is derated 2°C per 1000'

APPLICABLE STANDARDS
Radiated radio-frequency, electromagnetic field
NEBS Level 3 EN61000-4-3
immunity test,10 V/m
GR-3108-CORE Class 2: Protected Environments EN61000-4-4 Electrical fast transient/burst immunity test. 1kV.
Surge immunity test.
EN55022 Radiated emissions and conducted emissions EN61000-4-5 Line to line, 1kV
Line to ground, 2kV
EN61000-3-2 Limits for harmonic current emissions EN61000-4-6 RF common mode, 10Vrms
Limits for voltage and flicker in low voltage
EN61000-3-3 EN61000-4-8 Magnetic field, 10A
systems
Electrostatic discharge immunity test, 15kV Voltage dips, short interruptions and voltage
EN61000-4-2 EN61000-4-11
air, 8kV contact variations
Specifications are subject to change without notice

PAGE 3 OF 6
Doc. No. 2046924 Issue 2
J-series Rectifier Module Published 20-Mar-12

Dimension Drawings

TOP VIEW

SIDE VIEW

BOTTOM VIEW

FRONT VIEW BACK VIEW

PAGE 4 OF 6
Doc. No. 2046924, Issue 2
J Series Rectifier Module Published 20-Mar-12

Rectifier Connector Pin-out

Unit Connector p/n: 51939-140LF


Mating Connector p/n: 51866-025LF
Supplier: FCI/BERG

FCI NUMBERING 6 5 4 3 2 1
A LOGIC_GROUND AC_FAIL OPEN LOC1 SCL ISHARE
B MODULE_ALARM MODULE_PRST_OUT OPEN LOC0 RESERVED REMOTE_SENSE-
C MODULE_DISABLE MODULE_PRST_IN RESERVED AUX_OUTPUT_1 V_MARGIN SECONDARY_RETURN
D TEMP_ALARM OPEN LOC2 SDA SHORT_PIN REMOTE_SENSE+
P9
P8 OUTPUT POSITIVE
P7
P6
P5 OUTPUT RETURN
P4
P3 CHASIS GROUND
P2 AC LINE 1
P1 AC LINE 2

PAGE 5 OF 6
Doc. No. 2046924, Issue 2
J Series Rectifier Module Published 20-Mar-12

Rectifier Connector Pin-out Requirements


Non Isolated Signals Isolated Signals
OUTPUT+ and OUTPUT-
Power blades used for connecting positive and
negative power connections.
REMOTE_SENSE+ and REMOTE_SENSE-
These signals are used to compensate for
distribution drop across the output distribution. The
maximum voltage drop from the rectifier module to
the remote sense connection (the complete round
trip) must be maintained to less than 1V. The remote
sense leads may be left un-terminated in
AC_FAIL
applications where remote voltage regulation is not
required. This signal is an opto-isolated open collector signal
referenced to LOGIC_GND within each rectifier.
ISHARE AC_FAIL is a normally closed signal which signifies
All rectifiers ISHARE pins are tied together on the the presence of an alarm with a high impedance.
system backplane to support load sharing. This AC_FAIL indicates the presence of valid AC input
connection may be terminated between rectifiers or voltage to the rectifier.
left un-terminated in systems where load share is
MODULE_ALARM
not required.
This signal is an opto-isolated open collector signal
SHORT_PIN referenced to LOGIC_GND within each rectifier.
The short pin is used to disable the rectifier if not MODULE_ALARM is a normally closed signal which
fully seated in a sys- tem. It is required to be tied to signifies the presence of an alarm with high
OUTPUT- in the system backplane in order for the impedance. MODULE_ALARM is designed to provide a
rectifier to provide proper output voltage. It may not power fail warning to indicate the pending loss of DC
be left un-terminated. voltage during line drop conditions. MODULE_ALARM
is asserted at least 5msec prior to loss of DC output
Address Pins (LOC0, LOC1, LOC2, LOC3)
voltage during these conditions.
LOC0, LOC1, LOC2 and LOC3 are location pins used to
set rectifier address in a system where the I2C bus is TEMP_ALARM
shared between rectifiers. They may be left un- This signal is an opto-isolated open collector signal
terminated to generate logic 1 or connected to referenced to LOGIC_GND within each rectifier.
OUTPUT- to generate logic 0. TEMP_ALARM is a normally closed signal which
signifies the presence of an alarm with high
I2C Communications Bus (SCL, SDA)
impedance. TEMP_ALARM indicates that the rectifier
The I2C Communications Bus provides information
module has shut down due to an over-temperature
about internal rectifier conditions as well as full
condition.
control of output voltage and alarming setpoints.
SCL and SDA are common data signals and can be MODULE_DISABLE
wired directly to a system controller or on a common This signal is a current limited input designed to
shared bus between the rectifiers in a system and accept a 3.3V to 5V input voltage. Applying a voltage
the main system controller. The rectifiers between these pins will result in disabling the DC
communicate via the proprietary Valere output voltage from the rectifier. This signal may be
Communication Protocol. Contact your Eltek Valere left un-terminated in systems where
representative for technical assistance in interfacing MODULE_DISABLE is not required or is implemented
to the rectifiers using this interface protocol. The I2C via the I2C Interface.
Bus signals are logic referenced to OUTPUT-.
MODULE_PRESENT_IN/OUT
This is a general-purpose, configurable signal
interface used to detect module presence.

PAGE 6 OF 6