Two Stage Heavy Oil Burners: Press N Series
Two Stage Heavy Oil Burners: Press N Series
Two Stage Heavy Oil Burners: Press N Series
PRESS N SERIES
PRESS 30 N 85/171 342 PRESS 45 N 114/205 513 PRESS 60 N 171/342 684 PRESS 100 N 285/490 1140 kW kW kW kW
The PRESS N series of burners covers a firing range from 85 to 1140 kW and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups or for use in industrial applications, like small or medium plants. Operation is two stage; a servomotor adjust automatically air damper opening, to obtain the right air delivery on both stage. The combustion head, that can be set on the basis of required output, allows optimal performance ensuring good combustion and reducing fuel consumption and is available in two different length to be selected on the basis of specific application requirements. In basic version the burners are supplied for use with heavy oil 7E viscosity, but they can be supplied with higher viscosity oil with a specific heaters kit. Simplified maintenance is achieved by the slide bar system, which allows easy access to all of the essential components of the combustion head.
TS0042UK00
TECHNICAL DATA
Model Burner operation mode Modulation ratio at max. output Servomotor type run time Heat output Working temperature NCV Heavy Oil s kW Mcal/h kg/h C min./max. kWh/kg kcal/kg mm2/s (cSt) type delivery kg/h bar Max. C type Max. C Ph/Hz/V Ph/Hz/V type kW kW kW IP kW A A IP kW A A IP type Ignition transformer Operation Sound pressure dB (A) W mg/kWh N Bacharach mg/kWh mg/kWh V1 - V2 I1 - I2
PRESS 30 N
PRESS 45 N
PRESS 60 N
PRESS 100 N
Two stage 2:1 LKS 210 5 85/171342 73/147294 7,5/1530 114/205513 98/176441 10/1845 0/40 11,4 9800 50 (150 with heavy oil kit) D67 65 (20 bar) 20 140 YES Centrifugal with forward blades 60 1/50/230~(10%) 3N/50/400~(+10%) 1/50/230~(10%) RMO 3,5 0,33 2,8 3,7 0,45 2,8 40 ----0,37 2,9 9,5 0,45 1,9-1,1 9,5-5,5 54 -230 V - 2x6,5 kV 2 A - 35 mA
Intermittent (at least one stop every 24 h)
50 (500 with heavy oil kit) E4 E6 110 (20 bar) 200 (20 bar)
Atomised pressure Fuel temperature Fuel pre-heater Fan Air temperature Electrical supply Auxiliary electrical supply Control box Total electrical power Auxiliary electrical power Heaters electrical power Protection level
3/50/230~(+10%)
9,0 0,5 7
Electrical data
Pump motor electrical power Rated pump motor current Pump motor start up current Pump motor protection level Fan motor electrical power Rated fan motor current Fan motor start current Fan motor protection level
75
78
--
83
Emissions Approval
Sound power CO emission Grade of smoke indicator CxHy emission NOx emission level Directive Conforming to Certification
Reference conditions: Ambient temperature: 20C Barometric pressure: 1013.5 mbar Altitude: 100 meters a.s.l. Noise measured at a distance of 1 meter.
Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.
FIRING RATES
11
PRESS 100 N
10 9 8 7 6 5 4 3 2 hPa (mbar) 1 0 0 10 20 30 40 50 60 70 80 90 100 kg/h kW
PRESS 30 N
10 0
100
200
300
400
500
600
700
800
900
1000
1100
FUEL SUPPLY
HYDRAULIC CIRCUITS The burners are fitted with an oil pre-heater, a check valve and two delivery valves along the oil line from the pump to the nozzles. The oil pre-heater is equipped with a filter with sheath for thermometer, a setting thermostat to adjust the oil temperature and two safety thermostats to control the max. and min. oil temperature. A control device, on the basis of required output, regulates oil delivery valves opening, allowing oil passage trough the valves and the nozzles whose opening is regulated from a needle valve. An oil delivery gauge allow to control the delivery pressure. For heavy oil preheating, a special kit could be used; equipped with electrical heaters, it permits the employment of PRESS N burners with fuel oil of max. viscosity 20E at 50C (PRESS 30N - 45N) or 50E at 50C (PRESS 60 N 100 N), (see Burner Accessory paragraph).
PRESS 30 N - 45 N - 60 N - 100 N
P S
Vg VS1 VS2
Pump with filter, heater and pressure regulator on the output circuit Oil preheater with filter, maximum, minimum and regulation thermostat Oil temperature regulator Max oil temperature switch Min oil temperature switch Check valve
TE
MM
S
TE TM Tm
V1 V2
U1 U2
TM Tm Vg
VS2 2nd stage delivery valve V1 V2 U1 U2 1st stage nozzle needle valve 2nd stage nozzle needle valve 1st stage nozzle 2nd stage nozzle
DIMENSIONING OF THE FUEL SUPPLY LINES The fuel feed must be completed with the safety devices required by the local norms. IMPORTANT NOTES - The oil could easily flow through the pipes if those are properly sized, protected and heated (by electricity, steam or hot water) - In order to limit gas or steam production the oil pressure into the gas separator shall be set in function of the supply temperature, see instructions manual. - The forwarding pump should have at least a double capacity than that one of the burner. For several burners supplied through the same ring supply line, the forwarding pump should have a capacity of approximatively 30% more than the sum of the single burners outputs.
Double pumping unit with filter and heater on transfer ring Double pumping unit with filter and heater on main ring Gas separator bottle Pump with heater burner circuit Electrical preheater Preheater safety valve Burner Flexible oil line Thermometer Max oil temperature switch Temperature switch regulation Vent valve Oil filter
VR2 Oil valve main ring B P1 PS VS BR VGZ Safety valve burner circuit
PS T TE
MM TM
TF1 T TM TE VC F
RS2
VENTILATION
The ventilation circuit of PRESS N burners is inserted in a extremely compact structure and it is provided with a forward blades centrifugal fan, which guarantees high pressure levels at the required air deliveries and permits installation flexibility. A servomotor adjust automatically air damper opening, to obtain the right air delivery on both stage.
COMBUSTION HEAD
Two different lenghts of the combustion head can be chosen for the various models of the PRESS N series of burners. The choice depends on the thickness of the front panel and the type of the boiler. Depending on the type of heat generator, it is necessary Min output to check the correct head penetration into the combustion chamber. The internal position of the combustion head can easily be adjusted: refer to the burner instruction manual for the complete procedure. Max output The following diagram shows the flame dimensions in relation to the burner output. The lenght and diameter shown in the diagram below should be employed preliminary check: it is required a more careful investigation Example of a PRESS N burner if combustion chamber dimensions are much different combustion head from the above reported values. Dimensions of the flame
4
Lm
3 Lenght of the flame (m)
ax
D L
Diameter of the flame (m)
Lm
in
1,5
D max
D min
0,5
Example: Burner thermal output = 2000 kW; L flame (m) = 2,7 m (medium value); D flame (m) = 0,8 m (medium value)
WIRING DIAGRAMS
Electrical connections must be made by qualified and skilled personnel, according to the local norms.
8 9 10 11 12 PS
TL
TB
2,5 mm2
IN
TR
PE L N 50Hz 230V
MB TS TL TR S TB IN T16A PS
- Burner terminal board - Safety thermostat - Threshold thermostat - High/low flame setting thermostat - External lock-out signal - Burner ground (earth) connection - Manual switch - 16A fuse - Lock-out reset button
L N TS
S3 T1 30 T2 S
P
T6 TL
T8 V21V22 TR
T16A
T6A
IN
2,5 mm2
L
230V
3 3
~ 50Hz
PE L N L1 L2 L3
~ 50Hz
N L
230V
MB TS TL TR S F TB IN T6A T16A F PS L
- Burner terminal board - Safety thermostat - Threshold thermostat - High/low flame setting thermostat - External lock-out signal - Fuse (see table A) - Burner ground (earth) connection - Manual switch - 6A fuse - 16A fuse - Fuse (see table A) - Lock-out reset button - Lead section (see table A)
L N TS
S3 T1 30 T2 S
P
T6 TL
T8 V21V22 TR
F1
T6A
IN
MB TS TL TR S F TB IN T6A T16A F - F1 PS L - L1 - Burner terminal board - Safety thermostat - Threshold thermostat - High/low flame setting thermostat - External lock-out signal - Fuse (see table A) - Burner ground (earth) connection - Manual switch - 6A fuse - 16A fuse - Fuse (see table A) - Lock-out reset button - Lead section (see table A)
L1 PE L1 L2 L3 N
3 3
L L1 L2 L3
3 3
~ 50Hz
3 M
N L
230V
The following table shows the supply lead sections and the type of fuse to be used.
Model
PRESS 30 N
230V
PRESS 45 N
230V 400V
PRESS 60 N
230V 400V
PRESS 100 N
230V 400V
F L F1 L1
A mm2 A mm2
T16 2,5 -
T10 1,5 -
T6 1,5 -
Table A
BURNERS
A E G - G(1)
O - O (1)
Model
P R
S M 10 M 10 M 10 M 12
PACKAGING
Z Y X - X(1)
kg 84 84 87 104