Plant Model APPLICATION RECOMMENDED OIL QTY. 1 ST CHANGE HOURS 2 ND CHANGE SUBSEQUENT HOURS SPECIAL REMARKS
Breather plug & drain plug should be fix in proper position.
Extractor Belt SERVOMESH-320 10 150 500 Every 500 Hours Check the breather hole for proper ventilation.
FRL Unit ENGINE OIL 20W40 0.25 Periodically - As per low level mark on container Should be covered from dust.
Oil bath filter - Please check for level defines hole in oil container. Should
ENGINE OIL 20W40 0.25 Periodically - As per low level mark on container be covered from dust & water.
Compressor
Approx. 4-5 All bearing & blocks. Suitable for Multi purpose - Lithium
Bearing blocks AP-3 or MP-3 Grade grease Periodically - At regular intervals based on usage of machine. based Grease (AP or MP)
Kgs.
GREASE WITH CONSISTENCY Grease should be suitable for use under extreme pressure
Mixer shaft sealing 2 Kgs. Periodically - As per low level mark on container & machine usage. (EP). Eg. In HP brand LITHON EP1
CLASS NLGI 1 (EP1)