Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Brochures Horiba

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ABX Micros 60 Process efficiency in Hematology

PHYSICAL SPECIFICATIONS SOFTWARE SPECIFICATIONS


• Dimensions & Weight: • Data Processing:
Height Width Depth Weight LCD screen with 2 lines of 40 alphanumerical characters
44 cm 36 cm 33cm 14 Kg Capacity: Last result + graphics
16.5 in 14.2 in 12.6 in 31 lb Optional memory smart card - 78 results
• Throughput: Unidirectional connection RS 232
Up to 55 samples/hour in Closed or Open Tube QC and Patient results can be transmitted to LIS
• Specimen Volume:
• Quality Control Management:
CBC - 10 µl / CBC 3 part DIFF - 10µl
Smart card based QC - standalone (31 data points x 3 levels)
• Power Requirements: Optional Lite DM™ data management software
Power supply from 90 Vac to 240 Vac
50 Hz to 60 Hz PARAMETERS & PERFORMANCE DATA
Power consumption Maximum 230 VA
• 16 Parameters
• Reagents:
WBC RBC RDW
Micros 60 bottle reagents:
GRA # & GRA% HGB PLT
Minidil
MON# & MON% HCT MPV
Alphalyse 360
LYM# & LYM% MCV
Miniclean
MCH
Minilyse
MCHC

ABX Micros 60
Micros 60 Pack reagents:
Minipack
• Linearity:
• Sound Pressure Level: Parameters Limits
<60 dBa WBC 0 - 100 x 103/mm3
• Operating Temperature & Humidity: RBC 0 - 8 x 106/mm3
16 - 34°C (61 - 93°F) room temperature HBG 0 - 26 g/dL Process efficiency in Hematology
Maximum relative humidity 80% for temperature up to 31°C (88°F) HCT 0 - 80%
decreasing linearity humidity at 40°C (104°F) PLT (A)* 0 - 2200 x 103/mm3
PLT (B)* 0 - 4000 x 103/mm3

METHODS & TECHNOLOGIES • Precision:


• RBC/PLT detection principles Parameters %CV Nominal Values
Method Impedance WBC < 2.5 10 x 103/µL
RBC < 2.0 5 x 106/µL
• HGB measurement HGB < 1.5 15 g/dL
Method Photometry HCT < 2.0 45%
Wavelength 555 nm PLT < 5.0 300 x 103/µL

• HCT measurement • Carry-over:

Subject to technical modifications / AD-041113-1 Rev.2 USA VERSION


Method Numeric integration Parameters % Blood count level
WBC < 0.5 63.0 x 103/mm3
• WBC measurement RBC < 0.5 7.58 x 106/mm3
Method Impedance HGB < 0.5 23.4 g/dL
PLT < 0.5 988 x 103/mm3
• 3 part Differentiation
Method Impedance *A for Hgb > 2 g/dL and RBC > 0.5 x 106/mm3
Specific lyse action *B for Hgb < 2 g/dL and RBC > 0.5 x 106/mm3
• Calculated Parameters
MCV, MCH, MCHC, RDW
CERTIFICATIONS
UL 61010-1:204 R7.05
CAN/CSA-C22.2 NO. 61010-1-0-4

FRANCE +33 (0)4 67 14 15 15 - BENELUX +32 (0)3 281 49 08 - ITALY +39 / 06 51 59 22 1 - SPAIN +34 / 91- 353 30 10 - PORTUGAL +351 / 2 14 72 17 70
UK +44 (0) 1604 542650 - POLAND +48 / 22 6732022 - USA +1 / 949 453 0500 - BRAZIL +55 / 11 5545 1500 - THAILAND +66 / 2 861 59 95
CHINA +86 / 21 3222 1818 - INDIA +91/ 11 464 65 00 - GERMANY AXON LAB AG +49 / 7153 92260 - DISTRIBUTORS NETWORK +33 (0)4 67 14 15 16
HORIBA Medical online : http://www.horiba.com/medical
Solutions adapted to your needs

ABX Micros 60
> Concepts and Technology > Flexible with a list of options
• Lite DM software
• CBC
Comprehensive QC management
Impedance, selective lysing
Process efficiency in Hematology (LMG) Customizable test panels
Cumulative reporting
• Liquid valves EMR / LIS connectivity
Precise volumes and reliability
• Quality control management
• No compressor Smart card based QC-standalone
Stepper motor and low noise (31 data points x 3 control levels)
• Sampling mode
> Automatic Maintenance Open tube, or
Automatic cleaning of the Closed Tube (4 position tube holder)
sampling probe • Identification mode
Alphanumerical (with internal keyboard)
> 16 parameters Barcode reader (for patient’s ID number)
WBC, RBC, HGB, HCT, MCV, • Integrated Reagents
MCH, MCHC, PLT, MPV, Bottles / Minipack
• Up to 55 samples per hour RDW, LYM (% and #),
MON (% and #), GRA • Memory
• CBC / 3 DIFF 16 Parameters
(% and #), WBC, RBC and Last result + graphics
• Open or Closed tube optional memory smart card - 78 results
PLT histograms
• Compact and lightweight (rewritable memory smart card)
• Micro-sampling:
10µl of whole blood per cycle

• Simple and easy menu • Fully-automatic analysis cycle • Only 3 reagents (diluent, lyse, cleaner)

Comprehensive QC and Patient Micros 60 Sample Tube Holder Barcode reader Keyboard Self contained pack
Utilizes Multiple
Data Management Open tube system available for reagents/waste
Tube Sizes

You might also like