Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SAWO Steam-Generator

Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

MANUAL

Models
STP-30-1/2 STP-45-1/2 STP-45-3 STP-75-3 STP-90-3
STP-35-1/2 STP-50-1/2 STP-60-3 STP-75-3-C1/3 STP-90-C1/3
STP-40-1/2 STP-60-C1/3 STP-120-3
STP-150-3

Congratulations on your purchase of a SAWO Steam Generator.


Please read the manual carefully before using the steam generator.

230V 230V
3,0 kW1N~ KATSO 6,0 kW1N~ KATSO
TÄRK OHJEISTA TÄRK OHJEISTA
EÄT EÄT
BEAC LISÄOHJEET BEAC LISÄOHJEET
ZUSÄHTEN SIE ZUSÄHTEN SIE
LÄGG ANWETZLICHENDIE LÄGG ANWETZLICHENDIE
VIKTIGMÄRKE TILL BEDIEISUNGEN WICHTIGEN VIKTIGMÄRKE TILL BEDIEISUNGEN WICHTIGEN
TILLÄ A DE NUNG IN DER TILLÄ A DE NUNG IN DER
GGSA SANLE GGSA SANLE
READ NVISN ITUNG READ NVISN ITUNG
INGAR INGAR
ADDITTHE MANU NA ADDITTHE MANU NA
INSTRIONAL IMPOR
AL FOR INSTRIONAL IMPOR
AL FOR
UCTIO UCTIO
NS TANT NS TANT

798023 798023

Serial Number Serial Number


3.0 kW 4.5 kW 4.5 kW
3.5 kW 5.0 kW 6.0 kW
4.0 kW 7.5 kW

230V
3,0 kW1N~ KATSO
TÄRK OHJEISTA
EÄT
BEAC LISÄOHJEET
ZUSÄHTEN SIE
LÄGG ANWETZLICHENDIE

STEAM
VIKTIGMÄRKE TILL BEDIEISUNGEN WICHTIGEN
TILLÄ A DE NUNG IN DER
GGSA SANLE
READ NVISN ITUNG
INGAR
ADDITTHE MANU NA
INSTRIONAL IMPOR
AL FOR
UCTIO
NS TANT

798023

Serial Number

GENERATOR
9.0 kW
12.0 kW
15.0 kW
SAWO Steam Generator

TABLE OF CONTENTS
Before Installation 2
Steam Room Guidelines 2
Steam Generator Parts 3
Instructions of Use 4
On/Off Mode 4
Standby Mode 5
Auto Drain Mode 5
Temperature / Timer 5
Key Lock 6
Changing the Values 6
Optional Features 6
Cabin Light / Dimmer 6
Fan 6
Scent Pump 7
Demand Button 7
Switching Between Different Modes 7
Maintenance 8
Decalcification 8
Level probe cleaning 9
Tank cleaning 9
Assembly and Installation 10
Plumbing 10
Steam Generator 11
Water Supply 11
Water Pressure 11
Connecting Water Filter and Softener 11
Steam Outlet 12
Steam Guard Overflow 12
Steam Head 12
Drain 13
Attaching Autodrain 13
Power Wiring 13
Technical Data 14
Electrical Diagram 14
Installing the Temperature Sensor 17
Installing Control Unit 18
Connection of SAWO 19
Control to the PCB
Terminal Connection of 20
Demand Button (optional)
DIP Switches in the Steam Generator 21
Steam Generator Series Connection 22
Troubleshooting 22

1
Before Installing

Use the following information together with the consultation of your contractor, architect
or designer in determining all factors necessary in providing a suitable and safe steam
room.
Check that the supply voltage is suitable to your steam generator.

Ensure that the steam generator kilowatt corresponds to the volume of your steam room.
Refer to Technical Data (Page 14).

The voltage of the light output is 230VAC. Sawo


recommends to use less than 50V for the steam
room lightning. Use appropriate transformer for
lower voltages. Sawo is not responsible of
WARNING damages caused by using higher voltage inside
the steam room.

Steam Room Guidelines


1. The Steam Room must be fully enclosed, complete with walls, door, flooring and ceiling.
2. Rubber linings (e.g. gaskets) are recommended for the door to effectively seal the heat
and the steam inside the Steam Room.
3. If tiles are used for the flooring or some other smooth surface material, provide
suitable anti-skid strips or rubberized mats to prevent slipping resulting to injury.
4. Materials used for the walls and ceiling should have water-resistant, non-
corrosive surfaces such as tiles, marbles, molded acrylic, or other non-porous
materials. The ceiling should be dome-shaped to prevent the dripping of conde-
nsate.
5. A drain must be provided in the flooring.
6. Heating, venting or air conditioning devices should not be installed inside the
Steam Room.
7. Steam Room windows should be double paned.
8. Limit the Steam Room ceiling to a height of 2.5 meters. Exceeding 2.5m will require
a higher-rated steam generator.
9. Floor drain for the steam generator must be available for maintenance.

2
Steam Generator Parts

For illustrative purposes only.

Terminal for
Terminal for Contactor steam generator
incoming line accessories Solenoid Valve

Power switch Water Level Probe


Transformer
Steam Outlet

Steam guard overflow

Autodrain

PCB cover

Alternative
Drain outlet

For illustrative purposes only.


Not for use for wiring. For
component identification only.
WARNING

3
Instructions of Use
There are four different operation modes in the unit: Off, On, Standby and Drain. The user
can easily switch between different modes, making the steam bathing more convenient
with less energy consumption.

To use steam room the control unit needs to be in the On mode. In the On mode, the
steamer is active, the temperature in the steam room will be kept in the preferred, set
temperature, with occasional discharge of steam.

However, if the steam room is not used constantly, the generator can be set to Standby
mode. The water in the tank is kept warm, with minimal energy usage. The generator is
able to produce steam shortly after the unit is switch back to On mode for the convenience
of the users.

More details about the different modes and how to move between them can be found in the
text and graph following.

Power Cabin lights/Dimmer

Standby
Fan/Scent pump

Down Up

On/Off Mode Temp./Timer

On/Off Mode
When the power switch is turned “On” the software versions of the control board and the
user interface will be displayed for 1 second each. Then the control unit will go to “Off” mode.
In the “Off” mode, the display is blank.

The auto drain can be disabled or enabled in the “Off” mode. Press and hold the Up button,
then press the Power button. The display will show “Adr oFF” or “Adr on” as feedback.

On Mode
For "On" mode press "Power" button.

First, the set steam room temperature is displayed blinking for 5 seconds. Then the user can
change the following settings; session time, temperature and fan (not all the models have
the same features), by pressing the corresponding button in the control unit. The up and
down arrow buttons can be used to increase and decrease the values.

If no buttons are pressed for 10 seconds, the set temperature for the steam room will be
displayed.

When the session time expires, the control unit will go to the “Standby” mode.

4
Standby Mode

During the standby-mode the water in the steam generator tank is kept hot. This minimizes
the time to produce steam when generator goes to on-mode next time.
Standby-mode can be activated by any of the following methods when the unit is in on-mode:
1. Short press “Standby” button
2. Short press “Power” button
3. When session time expires.
In standby-mode text “Standby” is displayed altering with the remaining standby time. To
change remaining time press “up” or “down” arrow buttons. If the time is changed during the
first 5 minutes after the activation of standby-mode, the time will be saved as a new default
standby time.
To activate on-mode again short press the “standby” button
To go off-mode:
1. Press “Power” button for more than 3 seconds.
2. Press “Standby” button for more than 3 seconds to activate autodrain process, after
which the unit goes automatically off-mode. (If autodrain feature is not available the
unit will go off-mode)
3. Wait until remaining standby time expires and autodrain process (if available)
completes

Auto drain Mode


The auto drain feature automatically drains the water system after every use. The tank is
flushed and will remain empty until the steam generator is used again.
After the Standby time runs out, control unit automatically goes to Autodrain mode. When
the drain cycle is activated, the generator’s tank will be filled first. The water inside the tank
will be cooled down, so the valve can be opened, as the water is not boiling hot anymore.
The draining process will take about 10 minutes.
User can cancel auto drain process whenever the water level in the tank is at normal or below
normal level by pressing “power” button for more than 3 seconds.
To start Auto Drain in "On" mode press "Power" or "Standby" button followed by a long press
(more than 3 seconds) of "Standby" button.

Temperature / Timer

The temperature/timer button can be used to switch between the temperature and session
time.
When the steam generator is switched on, the set temperature at the steam room is
displayed. It can be changed by pressing up and down buttons.
If the temperature/timer button is pressed, the remaining session time will be displayed. It
can be changed by pressing up and down buttons. The session time will be saved as the
default session time if it was changed within the first 5 mins from the beginning of “On”
mode.
If the temperature/timer button is pressed again, the unit will return displaying the set
temperature. In addition, if no buttons are pressed for 10 seconds, the set temperature of
the steam room will be displayed.

5
Key Lock Lock and unlock the key pad by pressing the up and down
buttons at the same time for more than 5 seconds. A high beep
will confirm the activation and the deactivation.

Only On/Off, Standby and Cabin light buttons are usable when the
key pad is locked. If other buttons are pressed, “----” is shown in the
display.

The key lock function is set automatically if it was left active


during the previous operation.

Changing the values


Pressing the up or down button in the settings menu will in- or decrease
the currently displayed value. A value cannot be in- or decreased above
or below its maximum or minimum value, if it is tried low tone buzzer
alarms the user.
The up and down buttons are repetitive. Holding the up or down button
will cause the value to in- or decrease with an increased rate.
If no keys are pressed within 5 seconds, changes in the values are
confirmed.
In the “On” mode, if no keys are pressed for 10 seconds, the display will
automatically display the set temperature.

Optional Features
(Optional features are not available in every model)

Cabin Light / If the dimmer is not present and the cabin light button is pressed, it will
switch the cabin light On/Off. When cabin light is ON red LED-indicator
Dimmer next to Cabin light button in the panel is lit.
If dimmer feature is available press “cabin light” button to turn cabin lights
on and off. Light intensity value will be shown in the display and by press-
ing “up” or “down” arrows cabin light can be brighten or dimmed respec-
tively.
If cabin lights are already turned on long press “cabin light” button to
activate dimmer in order to change light intensity.
If no buttons are pressed within 5 seconds the last cabin light intensity
value will be saved.
Fan
Fan can be operated in "On" and "Standby" modes. Long press (more
than 3 seconds) "Fan/Scent" button in order to switch fan on/off.

6
Scent Pump Before switching scent pump on make sure there is enough aroma in the
aroma container. Never run the scent pump dry.
Scent pump can be operated in "On" mode only. In order to switch scent
pump on/off short press “Fan/Scent” button. The Scent pump is allowed
to be turned on only when the water in the tank is boiling.

Each time the scent pump is switched on the interval of the scent pump
functioning is displayed. Interval can now be changed by pressing “up” or
“down” arrow buttons between 1 (scent pump is activated every 20 mins)
and 20 (pump on continuously). If no keys are pressed within 5 seconds,
the previously displayed value will be shown again and the scent pump
setting is saved.
If scent pump is on when the session time expires or the steam generator
is turned off by pressing “power” button, scent pump will turn off too.
Scent pump “on” and “interval” settings are saved and pump starts
automatically on the next session.
To switch off the scent pump short press “Fan/Scent” button in “On”
mode.
When the aroma oil is changed, check that the pipeline is not broken or it
does not leak. It is also recommended to wash the fragrance container
between changes, especially when using different fragrances.
The pump is easy to refill quickly: short press “Fan/Scent” button in “On”
mode to activate interval value display. Press and hold “Up” arrow button
to reach max. value 20 and scent pump will run continuously. It will take
about 10 seconds for every 1 meter of pipeline for aroma liquid to reach
the pump. As soon as the aroma liquid has reach the pump reset the
pump functioning interval as preferred.
Use only fragrances meant for steam generator use. Follow the instruc-
tions in the fragrance packing.

Demand Button
A separate demand button can be installed on any desired location
including inside the steam room. Press of the demand button will immedi-
ately release extra steam for 30 seconds.
Pressing the "Demand" button when the steam generator is in "Off" or
Standby" mode will switch the control unit to "On" mode.

1. Press On/Off button for more than 3 seconds.


Switching Between 2. Press On/Off button or demand button.
Different Modes 3. Press On/Off button for more than 3 seconds.
4. Press Standby button.
1
5. Press On/Off button or Standby button or when the
OFF 2 ON session time expires.
3 4 6. Press On/Off button or Standby button or demand
5 button.
7
7. Press On/Off button for more than 3 seconds or
6
S/B DRAIN when the drain time expires.
8
8. Press Standby button for more than 3 seconds or
when the session time expires. 7
Maintenance
1. Decalcification
Tap water contains impurities, for example lime, that can cause calcium deposit and
block the internal parts of the steam generator. To prevent this and prolong the
lifetime of steam generator it is recommended to have a water filter and water softener.
They are connected to the water source of the steam generator’s water inlet.
SAWO Decalcifying Solution can be used for decalcification. Follow these guidelines to
perform preventative maintenance of the steam generator.
STP Classic:
Never add the Decalcifying 1. Remove the cap of angled tube in the steam outlet piping.
Before opening, make sure that the generator is off. Pour
Solution when the the solution into the water tank.
generator is on, it can
WARNING cause serious burns! 2. Turn ON the steam generator and wait until water inside
the tank starts to boil. Let the solution boil 5 minutes.

3.1 If standby mode is available:


Decalcifying Solution
Press shortly Standby button. Steam generator goes to
Cap standby mode and after time expires, water will be drained
automatically. After draining screen goes to OFF state.
3.2 If standby mode is not available:
Turn OFF the steam generator. Let the solution stay in
the tank 30 minutes and then drain manually by pulling
lever down.
4. Fill and drain the tank with water two times more.
STP Touch Control:
1. Turn ON the steam generator.

2. Go to Settings menu by pressing three seconds the


settings icon. Scroll to the "Decalcifying" menu and press
"Start". Confirm by pressing "OK".

3. Next process shows that water is filled in the tank. After water
is filled, add decalcifying solution: open carefully the top cover
of the angled tube and pour the solution slowly to the tank.

4. After pouring the solution, press "OK" on the screen.


Steam generator will automatically go through
decalcifying process including draining. After process is
done, screen will go to off state.

Use Decalcifying Solution as follows:


Steam Decalcifying
Generator Solution
(kW) (ml)

3-7.5 250
9-15 500
For steam generators in commercial use (over 5
hours continuously daily) additional service plan
is recommended twice a year. Please contact
your service center for details.

Frequency for decalcification:


Unit dH where 1 dH is 10 mg calcium in 1 liter of water
< 3 ºdH = very soft water, decalcification every 500 operation hours
3-6 ºdH = soft water, decalcification every 100 operation hours
6-9 ºdH = hard water, decalcification every 50 operation hours
8 9-18 ºdH = very hard water, decalcification every 30 operation hours
2. Level probe cleaning
a. Disconnect steam generator from main supply before opening generator’s covers. Only
licensed electrician or professional maintenance person can open covers and do cleaning.
b. Use adjustable wrench to deattach 3 wires from level probe. Make sure that when connect-
ing wires back, wires are connected to right probes
c. Use adjustable wrench to remove level probe. Clean tip of the pins from impurities using
sandpaper. Don’t damage plastic coating on pins. If coating is damaged, replace level
probe. Tighten level probe by hands and use adjustable wrench only for final tightening.

3. Tank cleaning
Easy way of cleaning the tank.
a. Disconnect steam generator from main supply before opening generator’s covers. Only
licenced electrician or professional maintenance person can open covers and do cleaning.
b. Clean level probe as stated in 2.a to 2.b.
c. Remove temperature fuse and tank temperature sensor from terminal block.
d. Remove the cassette where the heating elements are attached and clean deposits from the
element
e. Remove deposits from bottom and sides of the tank. Open bottom plug to wash away
deposits. Don’t use autodrain valve since big particles can block autodrain valve.
f. Attach bottom plug and use teflon pipe seal if needed
g. Attach heating elements. Make sure that temperature fuse and tank tempesensor are on
the top of heating element. Inserting heating element upside down will prevent the tempera-
ture fuse from working

Do not overtighten the nuts


that hold heating element
cassette. Damaged nut
WARNING can lead to leakage.

9
Assembly and Installation
1. Location of the steam generator has to be near the steam room. Place it within 7.5 meters
to the steam room.
2. Steam generator has to be installed outside the steam room.
3. The steam generator must not be installed outdoors or areas that may damage the unit due
to climate conditions.
4. Do not install the steam generator or plumbing lines in unheated attic or any locations where
water could freeze.
5. The steam generator must not be installed in areas near flammable or corrosive materials or
chemicals such as gasoline, paint thinners, chlorine or the like.
6. Provide a level surface to install steam generator. Side hole slots are provided for wall
mounting. Make sure that the steam generator is secured and is level when mounted on the wall.
7. The steam generator has to be installed in an upright position only.
8. Install water filter and softener or alike when necessary.
9. Leave enough space for service and maintenance of the generator.

Minimum Space for Service and Maintenance


CEILING

min.150mm
STEAM ROOM
min.100mm

min.
300mm

WALL

min.150mm
FLOOR

Water Filter / Softener


Water source
Control unit
Water inlet
For illustrative purposes only.

Temperature sensor

Power supply

Dosing Nozzle
Steam Over
generator Pressure Demand
Button
230V
3,0 kW1N~ KATSO
OHJEISTA
TÄRKEÄT
BEACHTENLISÄOHJEE
ZUSÄTZLIC SIE T

Autodrain
LÄGG ANWEISUNHENDIE
VIKTIGAMÄRKE TILL BEDIENUN GEN WICHTIGEN
TILLÄGGSA DE IN DER
GSANLEITU
READ NVISNINGA NG
THE MANUAL RNA
ADDITIONA
INSTRUCT L IMPORTAN
FOR
IONS T

Steam Line

Drain

Steam Head
Scent Pump
Plumbing
The plumbing has to be done by a qualified licensed plumber. Plumbing should be in
accordance with national or local codes. Use unions for piping connections. Use only

10 prescribed brass piping or copper tubing. Never use black or galvanized pipe for the
plumbing as it can easily crack or damage.
Steam Generator
3.0 kW | 3.5 kW | 4.0 kW | 4.5 kW | If facing the wall there should
Side view
5.0 kW | 6.0 kW | 7.5 kW NOTE be at least 100mm allowance.
showing element
540mm Water Inlet access panel
3/4” BSP Power
Thread: Switch
1/2” BSP

Overpressure
Steam Valve
Outlet Valve

470mm
Automatic
Drain

Thread:
1” BSP

9.0 kW | 12.0 kW | 15.0 kW If facing the wall there should


NOTE be atleast 100mm allowance.
540mm Water Inlet
3/4” BSP Power
Thread: Switch
1/2” BSP

Steam
Outlet Valve
Overpressure
Valve
470mm
Automatic
Drain

Thread: Refer to Technical Data for


1” BSP specifications
Water Supply
NOTE

Provide a shut off valve on the water source for the steam generator. Turn off the inlet water
line before installing the unit. Refer to the water filter’s manual for the pressure requirement
when installing. Maximum water pressure without water filter/softener is 8 bar. The water flow
range must be at minimum of 4 liters per minute. Water softener is recommend to use.
Water Pressure
The water pressure required for the STP steam generators is 2-8 bar or 30-120psi. Below or
above the pressure requirement may lead to damage or malfunction of the water inlet.

Connecting Water Filter and Softener


For illustrative purposes only.

Water Filter /
Softener

11
Steam Outlet
The steam must move in a continuous flow to the steam room. Do not install valves on the
steam line. Use insulated, rated 120ºC or higher, brass pipe or copper tubing for steam
line to connect to the steam head as permitted by codes (see table below). Slope the steam
line height by 20mm per meter towards the steam head to avoid trapping of the condensate
and eliminate steam trap that blocks the flow of the steam.
Steam Guard Overflow
The overflow safety guard activates when there is an overpressure in the steam line. It
automatically opens and releases the pressured steam. When this happens, please check
your steam line for servicing.
Steam Head
Place the steam head on a safe area where bathers cannot get in contact with it as it can get
very hot. The steam head must be facing downwards. A teflon tape or equivalent needs to be
used on the thread for tightening it. Avoid using a wrench to tighten the steam head as it might
get scratched.
Running the steam line down and then up will create a
“steam trap” blocking the flow of the steam.

Do not use 1 steam line


when installing 2 steam
generators. Steam Line sizes
kW Steam
Line
3 - 7,5 1/2”
9 and above 3/4”

Installation with multiple steam head


Use a Teflon or Sealant
for the pipe threads Add valve to each steam
(3/4” BSP) lines when installing
multiple steam heads.
Steam Supply This is to control the
distribution of the steam
Recommended

Place a Sealant or inside the room.


Silicone to fill in the
gaps.
300mm

min. 3mm
Steam room wall

Recommended Steam Head Location


Recommended
300mm

12
Drain
Drain valve is provided for maintenance. Set drain connection for your steam
generator according to national or local plumbing requirements. Use only 1”
pipe for drain to avoid water clogged up.
Attaching the Autodrain
An extra outlet for the autodrain can
be found under the steam generator. Terminal Block
Top View 5

1. Attach the Brass tee into the outlet


that can be found on under and on
3
the side of the steam generator.

DRAIN
2. An extra outlet for the autodrain
can be found under the steam
generator.
3. Attach the autodrain to the brass
tee.
4. Open the cover of the steam
4
generator.
5. Put the wire through the hole on
the side of the steam generator.
6. Connect the wires in the terminal
block to its label.
7. Cover back the steam generator.
230V
3,0 kW1N~ KATSO
TÄRK OHJEISTA
EÄT LISÄO
BEAC HJEET
ZUSÄHTEN SIE
LÄGG ANWETZLICHENDIE
VIKTIGMÄRKE TILL BEDIEISUNGEN WICHTIGEN
TILLÄ A DE NUNG IN DER
GGSA SANL
READ NVISN EITUN
INGAR G
ADDITTHE MANU NA

Autodrain
INSTRIONAL IMPOR
AL FOR
UCTIO
NS TANT

Autodrain can also be Twist


connected below the steam generator
1 2

Brass Tee

Power Wiring
Only a qualified electrician should do the Electrical wiring connections.
Check the power supply before installing your unit. Single Phase connection, a 220-240V
supplied is required. Use two-wire supply source and equipment grounding wire of single
phase connection.
A 90ºC / 600V (HO7RN-F) rated insulated copper wire is required for SAWO steam generators.
Check size of wires in Ampere Chart in accordance with the National Electrical Code and local
electrical code.
The installation must include switch for all pole disconnection. Circuit breaker with 3mm
control gap is recommended.

13
Technical Data
Steam Heating Element Voltage Current Phase Wire
Size of Steam Generator
Model kW Room (mm)
Weight
Volume Type (V) (A) Size Width Depth Height (kg)
(m³) (kW) Number mm²

STP-30-1/2 3.0 2 x 1.5 kW STG-150 220 - 240 /


3 max 14 1N / 2.5 540 210 470 18
380 - 415 8 2N 2.5
STP-35-1/2 3.5 3.5 max 1 x 1.5 kW STG-150 220 - 240 / 16 1N / 2.5 540 210 470 18
1 x 2.0 kW STG-200 380 - 415 9 2N 2.5
STP-40-1/2 4.0 4 max 2 x 2.0 kW STG-200 220 - 240 / 18 1N / 4.0 540 210 470 18
380 - 415 10 2N 2.5
STP-45-1/2 4.5 2 - 5 1 x 2.0 kW STG-200 220 - 240 20 1N / 4.0 540 210 470 18
1 x 2.5 kW STG-250 380 - 415 12 2N 2.5
STP-45-3 4.5 2 - 5 3 x 1.5 kW STG-150 380 - 415 7 3N 2.5 540 245 470 20
STP-50-1/2 5.0 2 - 6 2 x 2.5 kW STG-250 220 - 240 / 22 1N / 4.0 540 210 470 18
380 - 415 8 2N 2.5
STP-60-3 6.0 3 - 10 3 x 2.0 kW STG-200 380 - 415 9 3N 2.5 540 245 470 20
STP-60-C1/3 6.0 3 - 10 3 x 2.0 kW STG-200 220 - 240 / 27 1N 6.0 540 245 470 20
220 - 240 / 16 3 2.5
380 - 415 9 3N 2.5
STP-75-3 7.5 4 - 15 3 x 2.5 kW STG-250 380 - 415 11 3N 2.5 540 245 470 20
STP-75-C1/3 7.5 4 - 15 3 x 2.5 kW STG-250 220 - 240 / 34 1N 6.0 540 245 470 20
220 - 240 / 20 3 4.0
380 - 415 11 3N 2.5
STP-90-3 9.0 8 - 20 6 x 1.5 kW STG-150 380 - 415 13 3N 2.5 540 295 470 23
STP-90-C1/3 9.0 8 - 20 6 x 1.5 kW STG-150 220 - 240 / 40 1N 10.0 540 295 470 23
220 - 240 / 23 3 4.0
380 - 415 13 3N 2.5
STP-120-3 12.0 15 - 28 6 x 2.0 kW STG-200 380 - 415 18 3N 4.0 540 295 470 23
STP-150-3 15.0 22 - 40 6 x 2.5 kW STG-250 380 - 415 22 3N 4.0 540 295 470 23

PLS. NOTE: This table is for steam rooms built in with light walls (tempered glass or acrylic. Steam rooms
with thick walls or ventilation, please use higher kilowatt steam generators.
Electrical Diagrams
CONVERTIBLE
POWER INPUT
3.0 kW | 3.5 kW | 4.0 kW | 4.5 kW | 5.0 kW
TRANSFORMER
L2 L1 N G
380-415V WATER
S

2N~ FEED
SOLENOID
VALVE

24VAC IN CONT. DRAIN FILL PE


4 core cable

L N G 230VAC in PROBE1
PROBE2
PROBE3
220-240V GROUND FUSE
1N~ FAN CONTROL NTC2
TEMP
BOARD
SCENT PUMP
SWITCH
4 core cable
LIGHT
4 meters

FUSE NTC2
CONTACTOR
STP-Touch STP-SST

CONTACTOR UNIT

Fan Scent Pump Light Auto 12V Temperature


Drain DC Switch Sensor
HEATING

14
ELEMENTS

HEATING Max
ELEMENTS 100W
CONVERTIBLE
L1 L2 L3 N G
380-415V
6.0 kW | 7.5 kW
3N~

TRANSFORMER
5 core cable
L1 L2 L3 WATER
S

FEED
SOLENOID
VALVE

4 core cable 24VAC IN CONT. DRAIN FILL PE


220-240V
3~ L N G 230VAC in PROBE1
PROBE2
PROBE3
GROUND FUSE
FAN CONTROL NTC2
TEMP
3 core cable BOARD
SCENT PUMP
220-240V SWITCH
1N~ LIGHT
PL 4 meters

CONTACTOR CONTACTOR FUSE NTC2


STP-Touch STP-SST

C C

CONTACTOR UNIT

Fan Scent Pump Light Auto 12V Temperature


Drain DC Switch Sensor
HEATING
H1

H2

H3

ELEMENT

HEATING
ELEMENTS
Max
100W

380-415V 3N~
L3 L2 L1 N G 4.5 kW | 6.0 kW | 7.5 kW
TRANSFORMER

S
GROUND WATER
FEED
SOLENOID
VALVE

5 core cable SWITCH


24VAC IN CONT. DRAIN FILL PE

230VAC in PROBE1
PROBE2
PROBE3
FUSE
FAN CONTROL NTC2
TEMP
BOARD
CONTACTOR
SCENT PUMP

C LIGHT
4 meters

CONTACTOR UNIT

HEATING
ELEMENT
FUSE NTC2
STP-Touch STP-SST
HEATING
ELEMENTS

Fan Scent Pump Light Auto 12V Temperature


Drain DC Switch Sensor

15
Max
100W
CONVERTIBLE
L1 L2 L3 N G
380-415V 9.0 kW
3N~

5 core cable TRANSFORMER

S
L1 L2 L3 WATER
FEED
220-240V SOLENOID
VALVE

3~
24VAC IN CONT. DRAIN FILL PE

4 core cable
230VAC in PROBE1
L N G PROBE2
220-240V PROBE3
GROUND FUSE
1N~ FAN CONTROL NTC2
TEMP
BOARD
3 core cable SCENT PUMP
SWITCH

PL LIGHT
4 meters

CONTACTOR CONTACTOR FUSE NTC2


STP-Touch STP-SST

C C

CONTACTOR UNIT

Fan Scent Pump Light Auto 12V Temperature


Drain DC Switch Sensor
H1

H2

H3

H4

H5

H6

HEATING
ELEMENTS
Max
100W

380-415V 3N~ L3 L2 L1 N G 9.0 kW | 12.0 kW | 15.0 kW


TRANSFORMER

S
GROUND WATER
FEED
SOLENOID
VALVE

5 core cable SWITCH


24VAC IN CONT. DRAIN FILL PE

230VAC in PROBE1
PROBE2
PROBE3
FUSE
FAN CONTROL NTC2
TEMP
BOARD
CONTACTOR SCENT PUMP

C LIGHT
4 meters

CONTACTOR UNIT
H1
H2
H3
H4
H5
H6

FUSE NTC2
STP-Touch STP-SST

HEATING
ELEMENTS

Fan Scent Pump Light Auto 12V Temperature


Drain DC Switch Sensor

16
Max
100W
Installing the Temperature Sensor
Before installation main supply of the generator must be switch off from the
circuit braker.
The temperature sensor comes along with the SAWO steam generator. It is recom-
mended to use only Sawo temperature sensor with Sawo generator as it may other-
wise not function correctly.Temperature sensor wiring should not be routed near
power cables or hot areas as it may cause electronic interference or damage to the
wires.
The sensor has an integrated 9-meter cable. If longer cable is (for illustrative purpose only)
needed use 2 x 0.5 mm2 to 2 x 1.0mm2 cable for extension.
1. The temperature sensor has to be installed:
Height 1.2-1.5 meters above the floor away from the steam 25m
m

head so that the steam will not hit the sensor directly.
2. An 25mm hole is required to insert the temperature
sensor. Do not create bigger or smaller hole. Clean
the hole before inserting the sensor. Figure 1
3. Make a hole in the cable lead-in on the side of
the generator to pull the cable through. Connect Terminal Block

the cable in the terminal block marked as


"TEMP". See figure 2.
SAWO Steam Generator
(shown with cover removed) Figure 2

TEMP

Temperature
Sensor

Fig. 3
4. Insert the temperature sensor through the
steam room wall. Do not apply staples or
other material that may damage the cable.

5. Apply silicone sealant on the hole in the wall


to create a moisture seal (Fig. 4). Make sure
that there is no trace of silicone on the
sensor as it may interfere its reading. Push sensor
head to lock
Fig. 4 Fig. 5

Wall
Silicone Sealant

17 Push to the
wall to stick
Cable
Installing Control Unit
SAWO Steam Control sets the temperature of your steam room. Mount the steam control
unit on an accessible area outside the steam room. It is recommended not to place the
steam control near to showers or similar wet places.

Never attempt to modify or to fix the steam control. Ask your licensed technician or your
nearest service centre for repair.

Before installation mains supply of the generator must be switch off from the circui breaker.

Installation Instructions
Check the most suitable area to place your steam generator control. The control and the
steam generator should be accessible for the user and maintenance. Do not install the
control unit inside the steam room! The cable of the control is 7.5 meters.
Mount the control in the wall, according to the specifications given below. Follow illustra-
tion.

If the control is attached to a


concrete wall, provide a
control holder or equivalent
NOTE
to mount the control into it.

A B
OPTIONAL
Interface Holders
160 mm
Contact your SAWO distributor

84 mm

Wall

Rectangle
C

Oval

18
Connection of SAWO Control to the PCB.
Before installation make sure that the generator is disconnected from the mains by switching off
the circuit breaker
1. Unscrew PCB cover on the side of the generator to get access on the PCB.
2. Guide the RJ12 control cable through the cable lead-in hole on the side of the generator
and then behind the side panel as described in the drawing below to reach RJ jacks on the
corner of PCB
3. Note that there are two black RJ jacks on the board. One is for the control cable and the
other one for the optional slave unit. The control cable and slave cable can be connected
to either of these jacks, the order is insignificant.

Innova
Steam Generator
Control
230V
3,0 kW1N~ KATSO
TÄRK OHJEISTA
EÄT LISÄO
BEAC HJEET
ZUSÄHTEN SIE
LÄGG TZLIC DIE
ANWEISU
VIKTIGAMÄRKE TILL HEN
BEDIENUNNGEN WICHTIGE
TILLÄ DE GSANIN DER N
GGSA LEITU
READ NVISN NG
THE MANU INGARNA
ADDITION
INSTR AL IMPOAL FOR
UCTIONS RTAN
T

4. Fasten the PCB cover and the top cover of the generator
5. Turn the mains on and switch on the power switch in the back of the generator
6. The software version should be displayed in the control unit
7. Turn the control unit on “On” mode to check it works properly

19
Terminal Connection of
Demand Button (optional) Terminal Block

Before installation make sure that the mains is disconnected


from the generator by turning off the circuit breaker.

(230VAC) LIGHT
1. Open the top cover of the generator

(24VAC)DRAIN
SCENT
PUMP

TEMP
SWITCH
(12VDC)ILL
FAN
2. Guide the cable through cable lead-in on the side of
the generator.
3. Connect the wires to their designated places in the
terminal block.
4. If the demand button has light connect the light wire
on the "ILL" labeled terminal

Make sure that polarity is right “ILL” output is +12VDC


and 20mA.

Light Fan Scent Pump


(optional) (optional)
Max. 100W Max. P100W Max. P100W
Power 230VAC Power 230VAC Power 230VAC

Terminal Block Terminal Block Terminal Block


(230VAC) LIGHT

(230VAC) LIGHT

(230VAC) LIGHT
(24VAC)DRAIN

(24VAC)DRAIN

(24VAC)DRAIN
SCENT

SCENT

SCENT
PUMP

PUMP

PUMP
(12VDC)ILL
SWITCH
TEMP

(12VDC)ILL
SWITCH
TEMP

(12VDC)ILL
SWITCH
TEMP
FAN

FAN

FAN

If you have optional


dimmer in steam genera-
tor, make sure that the
ligths are dimmable before
connecting. Steam genera-
tor uses phase control to
regulate power for lighting.

20
DIP Switches in the Steam Generator
FIRST BLOCK SECOND BLOCK

ON = 1
OFF= 0

SESSION

STANDBY

SLAVE
TEMP
DRAIN
SCENT PUMP
FAN

DIMMER
STAND-BY ON/OFF

Standby time Session Time


Standby time can be set according to Session time can be set according to user
user preferences by setting dip preferences by session dip switches on the
switches on the power controller board power controller board.
Standby Session Switch Switch Switch Switch
Duration Switch Switch Switch Time 2 3 4 5
Mode 6 7 8

4h 0 0 0 10min 0 0 0 0
6h 0 0 1 15min 0 0 0 1
12h 0 1 0 20min 0 0 1 0
18h 0 1 1 30min 0 0 1 1
Unlimited 1 0 0 45min 0 1 0 0
4h 1 0 1 1h 0 1 0 1
4h 1 1 0 2h 0 1 1 0
4h 1 1 1 4h 0 1 1 1
6h 1 0 0 0
First Block of 8 Switches 8h 1 0 0 1
DIP No. Function 12h 1 0 1 0
8 Standby mode duration 18h 1 0 1 1
7 Standby mode duration Unlimited 1 1 0 0
6 Standby mode duration 10min 1 1 0 1
5 Maximum session time 10min 1 1 1 0
4 Maximum session time 10min 1 1 1 1
3 Maximum session time
2 Maximum session time
1 Disable standby mode Dipswitches for
/ Enable standby mode Naming Slaves
Slave Switch Switch
Dipswitches for other Functions No. 1 2

Function On Off
1 0 0
Dipswitch
No.: 2 0 1
8 Cabin Light Dimmer option Dimmer option 3 1 0
enabled disabled 4 1 1
7 Fan Present Not Present
6 Scent Pump Present Not Present
5 Auto Drain Connected Not Connected
4 Temperature range 30-55°C 30-50°C
3 Slave Unit Yes No
2 Slave Number
1 Slave Number

21
Steam Generator Series Connection
Steam Generator Master Slave 1 Slave 2 Slave 3 Slave 4
Control Steam Generator Steam Generator Steam Generator

230V 230V 230V


3,0 kW1N~ KATSO
OHJEISTA
3,0 kW1N~ KATSO
OHJEISTA
3,0 kW1N~ KATSO
OHJEISTA
TÄRKEÄT TÄRKEÄT TÄRKEÄT
BEACHTENLISÄOHJEE BEACHTENLISÄOHJEE BEACHTENLISÄOHJEE
ZUSÄTZLIC SIE T ZUSÄTZLIC SIE T ZUSÄTZLIC SIE T
LÄGG ANWEISUNHENDIE LÄGG ANWEISUNHENDIE LÄGG ANWEISUNHENDIE
VIKTIGAMÄRKE TILL BEDIENUN GEN WICHTIGE VIKTIGAMÄRKE TILL BEDIENUN GEN WICHTIGE VIKTIGAMÄRKE TILL BEDIENUN GEN WICHTIGE
TILLÄGGSA DE IN DER N TILLÄGGSA DE IN DER N TILLÄGGSA DE IN DER N
GSANLEIT GSANLEIT GSANLEIT
READ NVISNINGA UNG READ NVISNINGA UNG READ NVISNINGA UNG
THE MANUAL RNA
ADDITIONA THE MANUAL RNA
ADDITIONA THE MANUAL RNA
ADDITIONA
INSTRUCT L IMPORTAN
FOR INSTRUCT L IMPORTAN
FOR INSTRUCT L IMPORTAN
FOR
IONS T IONS T IONS T

DIP SW DIP SW DIP SW


RJ12 Cable 3 = OFF 3 = ON 3 = ON
2 = OFF 2 = ON
1 = OFF 1 = OFF
Troubleshooting
If an error occurs, the steam generator will be switched off. There will be a warning beep
to alarm the user every 2 seconds. The code for the error will be displayed blinking in the
control panel, see the table below.
Please note, only a qualified electrician or maintenance personnel are allowed to make
the service operations and repairs!
If an error occurs in one of the slave units, error message is followed by slave number. For
example: E1 -> S2 -> E1 ->S2... Pressing ON/OFF button disables the slave and rest of
the generators can operate normally.

Possible errors are:


Code Problem Solution
E1 Temperature sensor 1 Check the wire between the sensor and the
not connected. control unit.
E2 Temperature sensor 1
short circuit. If there is no problem with the wires and they
are correctly installed, check the sensor.
E3 Temperature sensor 2
not connected.
If no problem can be found, contact the
E4 Temperature sensor 2 retailer.
short circuit.
E5 Temperature fuse defect. Check the wire between the fuse and the
control unit. Fuse has probably overheated.
The reason for it needs to be discovered
before using the steam generator again. A new
fuse is needed.

If no problem can be found, contact the retailer.

22
Code Problem Solution
E6 Water level too high and Check that the drain valve is not blocked.
operation not permitted. Clean the level probes. If no problem can be
found, contact the retailer.
E7 Water level too low and Check that water supply is open and there is
operation not permitted. enough pressure. Check solenoid valve.
Clean level probes. If no problem can be
found, contact the retailer.
E8 Illogical combination of Clean level probes. If no problem can be
water level measurements. found, contact the retailer.

E9 Fill failure Check that water supply is open and there is


enough pressure. Check solenoid valve.
Clean level probes. If no problem can be
found, contact the retailer.

E10 Drain failure Check that the drain valve is connected and
not blocked. Clean the level probes. If no
problem can be found, contact the retailer.
E11 Communication failure. Check the RJ12 cable. If the area where
cable is located has many other cables, it
can cause EMC problems.
If no problem can be found, contact
the retailer.
E12 Temperature is greater than Contact qualified electrician or maintenance
the maximum temperature. personnel before using the steam generator
again.
E13 No master steam generator Dip switch setting is incorrect. Check dip
connected switch settings.
Check RJ12 for loose contact. Replace RJ12.
If no problem can be found, contact the retailer.
STP_ML(En1017)

www.sawo.com
info@sawo.com Subject to change without notice.

You might also like