APPENDIX PARAMETER LIST


For the MGW-R power supply unit in the UPH series, see the parameters for the “MV30”.
For the MGW-R power supply unit in other series, see the parameters for the “MGW-K”.

Number Name Display Class Condition Standard value


0011 EDIT FUNC (2) BIN SET INPT 1100 1000B

Explanation : Selects various edit functions available on the EDIT screen.

7 6 5 4 3 2 1 0 bit

Program ERASING by cursor selection


0: Invalid (O No. must be specified by bit 2)
1: Valid (position the cursor and Press ERASE )
PROGRAM
Space block insertion at the time of
OUTPUT
0: Inserted
1: Not inserted
O No. input for program ERASING
0: O No. + ERASE (standard)
1: O No. + D + ERASE (to prevent mis-erasing)
Checking of plural O numbers in a program during
PROGRAM . If O No. except first one is found.
OUTPUT
0: Output is stopped
1: Not stopped
PROGRAM
Update or O No. comment in
OUTPUT
0: Not updated if a comment already exists
1: Updated even if a comment exists
PROGRAM
During OUTPUT , If an error block is found.
0: Input is stopped
1: Not stopped
O numbers in programs at the output of programs from tape
PROGRAM
or floppy disk.
OUTPUT
0: Output as they are.
1: Output in ( ) as a comment.
COMPILE mode
0: Standard speed (block displayed during compilation)
1: High speed (no block displayed during compilation)

2-1
Number Name Display Class Condition Standard value
0020 RS232C (1) BAUD RATE DEC SET INPT 4800

Explanation : Sets the data transfer rate (baud rate) of channel 1 Notes 1) for the RS232C interface.

Setting range: 300~38400

Unit : baud (bit/sec)

Note 1: The baud rate should be set meeting external unit to be connected; select either of the following.

Set value 300 600 1200 2400 4800 9600 19200 38400

Number Name Display Class Condition Standard value


0021 RS232C (2) BAUD RATE DEC SET INPT 4800

Explanation : Sets data transfer rate (baud rate) of channel 2 Note 1) for RS232C Interface.

Setting range: 300~38400

Unit : baud (bit/sec)

Note 1: The baud rate should be set meeting external unit to be connected; select either of the following.

Set value 300 600 1200 2400 4800 9600 19200 38400

Number Name Display Class Condition Standard value


0022 RS232C (1) WAIT TIMER DEC SET INPT 10

Explanation : Set the Input/Output watch timer [second] of Channel 1 of RS232C (ESC driver) (Note)

Setting range: 0~127

Unit : sec

Note: When reading the programs, if the data are not entered within the time set by this parameter, the
warning “7121 SEC1 TIME OUT ERROR” occurs.

2-2
Number Name Display Class Condition Standard value
0023 RS232C (2) WAIT TIMER DEC SET INPT 10

Explanation : Set the Input/Output watch timer [second] of Channel 2 of RS232C (ESC driver) (Note)

Setting range: 0~127

Unit : sec

Note: If no data is input or output for duration of time specified by this parameter during input/output via
external RS232C channel, the warning “7141: ESC2 TIME OUT ERROR” is displayed.

2-3
Number Name Display Class Condition Standard value
0025 RS232C INPUT FUNC BIN SET INPT 0000 0100B

PROGRAM
Explanation : Select functions for the INPUT key on EDIT screen.

7 6 5 4 3 2 1 0 bit

TV check (tape vertical parity check)


0: Invalid
1: Valid

Read of feed part having no hole


0: Alarm
1: No alarm

Read of special symbols (ISO code)................................Notes 1, 2)


0: Special symbols are ignored
1: Special symbols are read

End code of label skip function


0: Data up to first CR code is ignored
1: Data up to first CR code after ER code is ignored

Selection of program input source


00: RS232C channel 1
01: RS232C channel 2 (external RS232C)
10: ROM (basic data file: set data No.14)
11: Same a “10”

MP1 automatic rewind function


0: Invalid
1: Valid

Output of DC1 code


0: Output only once
1: Output at 1 sec interval until data is input

Note 1: Special symbols include the following 13 symbols.


# & ‘ * , < = > ? @ ” [ ]
Note 2: Be sure to set the bit 2 to “1” when the program is input from the system tape supplied by maker
or from the custom macro tape.

2-4
Number Name Display Class Condition Standard value
0026 RS232C OUTPUT FUNC BIN SET INPT 0001 0100B

PROGRAM
Explanation : Select functions for the OUTPUT key on EDIT screen.

7 6 5 4 3 2 1 0 bit

Output of TV parity bit


0: Not output
1: Output

Setting of line feed code in ISO


0: LF only
1: CR + LF

Output of % (ISO) and ER (EIA) as a delimiter...................Note 1, 2)


0: Not output
1: Output (About 400 characters in NUL code are added before and
after a program)..................................................................Note 3)

Selection of ISO/EIA
0: Output of ISO code
1: Output of EIA code

Selection of RS232C channel


0: Output to channel 1
1: Output to channel 2

Input of control code


0: CTS control
1: DC1/DC3 control

Output of control code (DC2, DC4)


0: Output
1: Not output

Selection of output start


0: Not wait for DC1
1: Wait for DC1

Note 1: Use this code to set whether programs are output successively.
Note 2: Multiple O numbers are output as one program.
Note 3: Programs are delimited into every program, and output.

2-5
Number Name Display Class Condition Standard value
0027 RS232C AUXILIARY FUNCTION BIN SET INPT 0001 0000B

Explanation : Selects auxiliary function when entering data via RS232C interface.

– 6 5 4 – – – 0 bit

Specifies block reading method in input of a part program from tape.


0: Reading every NC blocks.
1: Reading every 250 characters.

Specifies whether the feed area (1 m/min) is output when data is


output.
0: Outputs feed area before and after significant information (tape
puncher).
1: No output of feed area (auto programming unit)

Specifies DTR/RTS signal control when data is input or output.


0: DTR/RTS ON during data input or output
1: DTR/RTS ON when data input/output is started, and OFF when
data input/output is finished.

Addition of parity bit to control codes DC1/DC3


0: No parity added
1: Parity added

Number Name Display Class Condition Standard value


0030 O8000 PROTECT DEC SET CHG 2

Explanation : Sets the write protection for 8000 series programs.

Setting range: 0~2

Setting contents:
Set value Contents
The program is not protected.
0
(Write and deletion are possible as in the case of normal programs.)
Write and deletion are prohibited.
1
(It is possible to look over the comments of the program.)
Write, deletion and search are prohibited.
2
(No data is displayed on the edit screen.)

2-6
Number Name Display Class Condition Standard value
0031 O9000 PROTECT DEC SET CHG 2

Explanation : Sets the write protection for O9000 series programs. Note 1, 2)

Setting range: 0~2

Note 1: The O9000 series programs cannot be cancelled with the O8000 series programs kept protected.
Note 2: For the contents of set values, see set data No.0030.

Number Name Display Class Condition Standard value


0032 MACRO PROTECT DEC SET CHG 2

Explanation : Sets write protection for the programs O10000~14999. Notes 1, 2, 3)

Setting range: 0~2

Note 1: The write protection for O10000~14999 cannot be cancelled with the O8000 and O9000 series
programs kept protected.
Note 2: For the contents of set values, see set data No. 0030.
Note 3: The system macro will not operate normally if PRM0032 is set to “0” or “1”. In this case, return it
to “2” and turn on the power again.

Number Name Display Class Condition Standard value


0034 FUNC BY AUTO RUN COMPLETED BIN SET CHG 0000 0001B

Explanation : Selects functions automatically performed on completion of automatic operation.

7 6 – – – – – 0 bit

Automatic rewind of tape reader.................................................Note)


0: Invalid
1: Valid

RESET misoperation preventive function


0: Invalid
1: Valid

AUTO PWR
key after power is turned off
OFF
AUTO PWR
0: key is turned on at power on
OFF
AUTO PWR
1: key is turned off at power on
OFF
Note: The tape reader is optional for the MGW-J, JP, K, MV-20 and MV-30.

2-7
Number Name Display Class Condition Standard value
0035 BUZZER TIMER DEC SET INPT 0

Explanation : Sets the time value for restriction of buzzer sounding time.

Setting range: 0~127

Unit : sec

Setting contents:
Set value Contents
0: The buzzer sounding is not stopped.
1~127: The buzzer sounding is stopped after the set time (seconds) has
elapsed since the buzzer started to sound.

Number Name Display Class Condition Standard value


0037 BUZZER TIMER SELECTION HEX SET INPT 0000H

Explanation : Select functions for the buzzer.

– – – C B – 9 8 – – – – – – – – bit

Buzzer sound time when a key is pressed


00: 9 msec
01: 20 msec
10: 40 msec
11: 60 msec

Buzzer sound when the work tank moves down


0: Invalid
1: Valid

Buzzer sound when the work tank moves up


0: Invalid
1: Valid

Note: This set data is valid for the MGW-J and MGW-K.

2-8
Number Name Display Class Condition Standard value
0038 WATER ON DWELL FUNC BIN SET INPT 1000 000B

MACH
Explanation : Select functions for water dwell timer on OPE screen.
To prevent accuracy reduction due to thermal influence of water, the water dwell timer
turns on the WATER ON and SHOWER functions before start of machining so as to
minimize a difference in temperature between workpiece, water, and machine.

7 6 – – – – 1 0 bit

Timer subtraction method ........................................................Note 2)


0: After the timer is set, the counter is always subtracted,
irrespectively of NC status. (After the set time from now)
1: After the timer is set, the counter is subtracted, except when NC is
not in start status (i.e., in alarm, stop, or reset status). (After the set
time from operation stop)

Command method when calendar function is used.................Note 3)


0: Water dwell timer ON by specifying date (“D”__) and time (“T”__)
1: Water dwell timer ON by specifying time (“T”__) only (WATER is
turned ON at the time specified within 24 hours)

Water conductivity check by M17 is


0: Not executed
1: Executed

Water dwell timer commanding method


0: Timer
1: Calendar

Note 1: The water dwell timer is set by the timer or calendar, and the WATER ON and SHOWER functions
are turned on when the timer subtraction becomes “0” or the date and time reached the specified
value.
Note 2: The bit 0 is valid when bit 7 is set to 0.
Note 3: The bit 1 is valid when bit 7 is set to 1.

Number Name Display Class Condition Standard value


0040 DISP COOR. SYSTEM (L) SEC SET CHG 1
0041 DISP COOR. SYSTEM (M) SEC SET CHG 4
0042 DISP COOR. SYSTEM (R) SEC SET CHG 2

Explanation : Specifies coordinate values to be displayed to the left of the three coordinate systems on

the RUN screen.

Setting range: 1~5

2-9
Setting contents:
Set value Contents
1 Machine coordinate
2 Workpiece coordinate
3 Move remainder
4 Relative coordinate
5 Command coordinate

Note: The coordinates displayed on the FPB (portable operation panel) are same as those selected by
set data No. 42.

Number Name Display Class Condition Standard value


0044 ROTARY AXIS ANGLE DISPLAY BIN SET CHG Data by
SELECT Machine type

Explanation: Selects a display method of rotary axis angle.

0: Relative display (round off to ±360.000°)


1: Absolute display (±99999.999°)

– – 5 4 3 2 1 0 bit

For the 1st axis (X axis)

For the 2nd axis (Y axis)

For the 3rd axis (U axis)

For the 4th axis (V axis)

For the 5th axis (Z axis)

For the 6th axis (C axis)

Standard value by machine type:

MGW-J, MV-20, MGW-K, MV-30 MGW-JP

0000 0000B 0010 0000B

Note: Each bit is valid only if each axis is a rotary axis and the unit is degree.

2-10
Number Name Display Class Condition Standard value
0045 FUNC SELECTION 1 BIN SET CHG Data by
Machine type

Explanation : Selects a function related to the machine sequence.

7 6 5 4 3 2 1 0 bit

Ignores specified movement for initial hole (M20).


0: Invalid
1: Valid

High speed wire feed function (in RETRY RETRY RETRY )


1 2 3
0: Invalid Note 1)
1: Valid
Reference hole retry function (M75)
0: Invalid
1: Valid
Touch retry function (retry upon touch in the end)
0: Invalid
1: Valid
Ignores wire deflection check at start of auto wire threading at fine
hole
0: Invalid
1: Valid
Switches UNSPOL WIRE/WIRE FEED on the FPB panel
0: UNSPOOL WIRE
1: WIRE FEED
Process skip function (M74L_)
0: Invalid
1: Valid
Increased flow rate at start in water mode 3, 4 ...................... (Note 2)
0: Invalid
1: Valid
Standard value by machine type:

MGW-J, MGW-JP, MGW-K MV-20, MV-30

1100 1100B 0110 0100B

Note 1: In the RETRY mode, see set data No.54 bit 3.


3
Note 2: For the W-PG1, UPH-1, UPH-2 and UH2 (power supply units: MGW-JP, MV-20 and MV-30), the
flow rate is not increased at the start in the water mode 3, 4.
For the MGW-K, the flow rate is increased at the start in the water modes 7 and 8 .

2-11
Number Name Display Class Condition Standard value
0046 FUNC SELECTION 2 BIN SET CHG Data by
Machine type

Explanation : Select a function related to the machine sequence.

7 6 5 4 3 2 1 0 bit

JET key switching function


00: JET key
01: WIRE FEED key
10: FLUID key
11: TANK FILL key

At model plan expansion, initial positioning and M6 are,


0: output
1: not output

At model plan expansion on the machine with auto core remover,


M73L0/L1 is, Note)
0: output
1: not output

If MACH. START point on PROCESS CARD in model plan is not


entered, M6 in a subprogram is
0: Executed
1: Not executed

When the machining sequence on STREAM CARD of the Model Plan


is “2 (PUNCH), 3 (CORELESS), 4 (1-PART CUT)”, the rough cut and
skim cut are executed separately
0: Invalid (Rough cut, Skim cut - Cut-off)
1: Valid (Rough cut - Skim cut - Cut-off)

Wire cut-off position in a cut-off machining of Model Plan Punch


machining
0: M90P1 (pre-cutoff)
1: M90P2 (post-cutoff)

(Reserved for model plan)

Standard value by machine type:

MGW-J, MGW-JP, MGW-K MV-20, MV-30

0000 1000B 0000 0000B

Note: The bit 3 is not related to the presence of core removing unit.

2-12
Number Name Display Class Condition Standard value
0048 FPB DISPLAY AXIS SELECT HEX SET PWON 4321H

Explanation : Selects the axis to be displayed on the FPB operation panel. Note)

F E DC B A 9 8 7 6 5 4 3 2 1 0 bit

Axis No. on upper line on page 1 displayed on FPB


(1st~6th axes)

Axis No. on lower line on page 1 displayed on FPB


(1st~6th axes)

Axis No. on upper line on page 2 displayed on FPB


(1st~6th axes)

Axis No. on lower line on page 2 displayed on FPB


(1st~6th axes)

Note: Selection of axis number other than those actually installed causes the display to be blank.

2-13
Number Name Display Class Condition Standard value
0051 FEED/INTERPOLATE BIN SET CHG Data by
Machine type

Explanation : Selects additional functions for feed and interpolation.

7 6 – 4 3 – 1 0 bit

Dry run rapid feed


0: Invalid (RAPID feed)
1: Valid (JOG feed)

Override cancel
0: Valid
1: Invalid

Warning processing during Dry run


0: Stop by warning
1: Not stop by warning

Additional function of feed/interpolation is


0: Estimated
1: Not estimated

4-axis control
0: Invalid
1: Valid

In case of head collision, the axis feed in manual mode is


0: Not limited
1: Limited

Standard value by machine type:

MGW-JP MGW-J, MV-20, MGW-K, MV-30

0000 0000B 1000 0000B

2-14
Number Name Display Class Condition Standard value
0053 FUNC SELECTION 3 BIN SET CHG 1100 0000B

MODEL
Explanation : Selects functions for PLAN .

7 6 5 4 3 2 1 0 bit

When the machining condition is searched in the inch mode, whether


E.
or not the offset value is output to TABLE screen ..............Note 1)
0: Output in the unit of 0.0001 inch
1: Output in the unit of 0.00001 inch, and G919/G918 is automatically
output during compilation ...................................................Note 2)

Wire offset inversion (special application)


0: Invalid
1: Valid

Die finishing
0: Starts in reverse direction
1: Starts in forward direction

Dummy command codes are


0: Not output
1: Output

M74 is
0: Output
1: Not output

Remain/cut-off are controlled with


0: M8/M90
1: M#30 (#0/7)

Same search condition in editing the model data is


0: Not deleted
1: Deleted

M6 in a retrace subprogram is
0: Executed as it is
1: Executed as M6L1

2-15
Note 1: Bit 0 is valid in the standard resolution mode only.
Note 2: Only the following data is output in the unit of 0.00001 inch when the bit 0 is turned on.

Model Plan Description


• OFFSET ADJ. on MODEL SEAWRCH screen
Version 1
• D VAL. on MODEL E.TABLE screen
• OFFSET ADJ. in SEARCH window on CONDITION CARD

Version 2
• D value in E No. table on CONDITION CARD

 H/L value or CORELESS initial offset is given in 0.0001 inch.


 In the model Plan version 2, the decimal point displayed is not shifted and data is given in
0.0001 inch even if this bit is turned on.

2-16
Number Name Display Class Condition Standard value
0054 FUNC SELECTION 4 BIN SET CHG Data by
Machine type

Explanation : Select the functions related to the automatic wire threading.

7 6 5 4 3 2 1 0 bit

RETRY
3 method (YES/NO of touch rewind)

0: RETRY method (Touch rewind: NO)


0

1: RETRY method (Touch rewind: YES)


1
RETRY cutoff sequence (prudence in cutting operation)..... (Note 1)
3
0: Same method as RETRY or RETRY (prudent type)
0 1

1: High speed RETRY method (bold type)


3

Touch retry after wire threading by RETRY


3
(Retry if touched) .............................................................. (Note 1)
0: Conform to set data No.45 bit 3
1: Not conform to set data No.45 bit 3, ie., no touch retry

High speed wire feed function RETRY .................... (Note 1, Note 2)


3
0: Invalid (wire speed = machine PRM No.710, 711)
1: Valid (wire speed = machine PRM No.705, 710, 7558)

Timer value for RETRY automatic wire threading ............... (Note 1)


3
0: As per parameter value (machine PRM No.685 ~ 698)
1: Time is shortened internally if possible (60%, but not shortened in
wire break/power failure recovery)

Z axis position of reference point return in power failure recovery


0: Reference point ............... (Note 3)
1: Original M6 position
SKIPPED
Automatic wire threading by M6L1 in is
MACHING
0: Not executed ................. (Note 3, Note 6)
1: Executed
RECOVERY RECOVERY
High speed wire feed function at W.BREAK , P.FAIL or
M75 reference hole retry
0: Invalid
1: Valid (following the set data No.0045 bit 1 and No.0054 bit 3)

2-17
Standard value by machine type:

MGW-J, MGW-K
MGW-JP, MV-20, MV-30
15EC, 16EC Others

0001 1111B 0011 1111B 0001 1111B

Note 1: For the MV-20 and MV-30, bits 1, 2, 3, 4 are invalid.

Note 2: For the RETRY RETRY RETRY modes, see set data No.45 bit 1.
0 1 2
Note 3: Bits 5 and 6 are valid for the MGW-J and MGW-K only.
Note 4: Even with the same parameter setting, the wire threading time will vary depending on the machine
type (wire feed mechanism, guide operating mechanism, machine size, etc.) and operating
condition (adjustment, Z height, start hole diameter, etc.).
Note 5: The wire threading success rate will vary depending on whether or not the automatic wire
threading unit is properly maintained.
Note 6: Automatic wire threading is executed by M6L1 during M6 seawrch with the “SKIPPED MACHING”
turned off when PRM No.0054 bit 6 is “1”.
Note 7: This parameter is invalid for the MGW-JP.

2-18
Number Name Display Class Condition Standard value
0055 FUNC SELECTION 5 BIN SET CHG Data by
Machine type

Explanation : Select the functions related to the automatic wire threading (AWT).

7 6 5 4 3 2 1 0 bit

Z axis rising function AWT .......................................................Note 1)


0: Invalid
1: Valid
(MGW-J, MGW-K) Cut-off operation with M7 key
00: Low speed conventional operation following AWT Retry 0, 1, 2, 3)
01: Middle speed (Operation in AWT Retry 3 mode)
10: Not used
11: High speed (Cutter ON → Wire Draw-out only, No wire rewinding)
(MGW-J) Warning messages 4081/4082 “STROKE RESTRICTING/
EXPANDING” are, ...................................................................Note 2)
0: Not displayed
1: Displayed
(MV-20, MV-30) Circulation pump ON with the work tank in down
position ............................ Note 3), Note 4), Note 5), Note 6), Note 7)
0: Invalid
1: Valid
Coordinates of M75X_Y_ (reference hole retry)
0: Work coordinates
1: Machine coordinates
(MGW-J, K) FILL HEIGHT at AWT stop during OPT.TANK FILL ON
0: M6 fluid level (hold) ................... Restarting oriented
1: Fluid level return (rise) ............... Rust prevention oriented
(MV-20, MV-30) M59 (work tank up) at M6 search when AWT failed
0: Invalid
1: Valid
(MV-20, MV-30) Suction nozzle cleaning time extension
0: Invalid
1: Valid

(MGW-J, MGW-K) RETRY wire deflection sensing system


2
00: TOUCH-B (touch sensing) system
01: WL-SEN (deflection sensor) double sensing system
10: Touch & deflection double sensing system
(MV-30) Work tank down at automatic wire threading
0: Invalid
1: Valid

2-19
Standard value by machine type:

MGW-JP MV-20, MV-30 MGW-J, MGW-K

1000 0111B Data by machine No. 1010 0111B

Note 1: Validity condition of bit 0 (Z axis rising function at AWT) and the amount of rising
• “Automatic Z axis” + “Bit 0 is set to 1”
• The amount of rising is specified by machine PRM No.679
Note 2: For the bit 3, whether the warning is displayed or not displayed can be selected at the timing of
“POWER ON, RESET, MAN RUN mode” on the machine with auto Z axis + fine wire AWT
functions in which the Z axis is restricted during thin wire automatic threading.
Note 3: Instruct the users who perform the fine hole continuous machining to turn on this bit in order to
improve the accuracy.
Note 4: The water cooler runs at all times while the circulation pump is kept on.
Note 5: To make this bit valid, the water temperature sensor position must be changed.
Note 6: Select the “PUMP OFF” on the MACH OPE screen, if making the set-up or saving the data with
the circulation pump turned off.
Note 7: To prevent the cooler damage, the circulation pump ON is disabled for 3 minutes after the power
was turned off and on, even if this bit is turned on.
Note 8: This parameter is invalid for the MGW-JP.

2-20
Number Name Display Class Condition Standard value
0056 FUNC SELECTION 6 BIN SET CHG Data by
Machine type

Explanation : Select a function related to the approach. Note 1)

7 6 5 4 3 2 1 0 bit

DRY MACHINE
In RUN or LOCK mode, M17 approach 1, 2 machining
condition is.........................................................................Notes 2, 3)
0: Not checked
1: Checked

In graphic mode, M17 approach 1, 2 machining condition is


0: Not checked ........................................................................Note 3)
1: Checked

Whether a wire squeezed by the H and I shafts is cut off again or not
.................................................................................................Note 4)
0: Wire is not cut off again
1: Wire is cut off again

Selection of FPB WATER key and “OPT.TANK FILL”...........Note 5)


0: WATER
1: OPT.TANK FILL

Keeping intermediate water level by TANK FILL key ..............Note 5)


0: Invalid
1: Valid

Keeping intermediate water level when M6 float dropped


(W-AWTS=1) ...........................................................................Note 5)
0: Invalid
1: Valid

(MV-20, MV-30) Retry in case of wire break during auto wire threading
0: Retry is not executed ...........Note 5)
1: Retry is executed

(MGW-J, MGW-K) Wire feedrate after retry operation in high speed


wire feed mode
0: Low speed (Machine parameter No.707,711)
1: High speed (Machine parameter No.705, 710,7558)

Submerged automatic wire threading ......................................Note 5)


0: Invalid (water level lowered to W-AWTS)
1: Valid (water level not lowered)

2-21
Note 1: Approach function related set data No.330 ~ 333
DRY MACHINE
Note 2: In the RUN or LOCK mode, if approach machining condition is checked, the machining

COND COND
elements on the MAIN screen are returned to initial values registered on the LIST screen
respectively.
Note 3: Bits 0 and 1 are not used for the MGW-K and MV-30.
Note 4: Bits 3 is valid for MV-20 and MV-30.
Note 5: Bits 3, 4, 5, and 7 are valid for the MGW-J and MGW-K.
Bits 4 and 5 are valid for the MGW-J after version 10, and MGWK after version 4.0.
Bits 7 is valid for the MGW-J after version 11.0, and MGW-K after version 6.0.

Standard value by machine type:

MGW-JP, MV-20, MV-30 MGW-J, MGW-K

0000 0000B 1011 0000B

2-22
Number Name Display Class Condition Standard value
0057 FUNC SELECTION 7 BIN SET CHG Data by
Machine type

Explanation : Selects a function related to the machine sequence.

7 6 5 4 3 2 1 0 bit

Suction pump during tank filling (to such chips around lower head)
0: Not used (pump always OFF)
1: Used (pump ON during circulation)

(MV-20, MV-30) Rotating direction when AWT cutter unit is returned


0: Reverse (MV-20 standard)
1: Reverse (MV-30 standard)

Warning “4042: COOLER OVERHEAT”, Warning “4056: AIRDRYER


ALARM” of warning level
0: Warning 2 is displayed but the unit does not stop.
1: Warning 3 is displayed and the unit is stopped.

Drip function with FLUID ON


0: OFF (air blow is not performed)
1: ON (air blow is performed during FLUID ON)

The fluid quantity is checked before filling starts, and if low, the fluid is
added up to upper level
0: Invalid
1: Valid

(MGW-J, MV-20) Wire break/power failure recovery condition auto


setting function
0: Invalid (already set E9090 ~ E9099 retained)
1: Valid (E9090 ~ E9099 automatically set)
WORK ZERO
Z-axis movement in RETURN operation (1)
0: Z-axis does not move
1: Z-axis moves
WORK ZERO
Z-axis movement in RETURN operation (2)
0: Z-axis moves
1: Operation stops before Z-axis moves (Warning 2320) .........Note)

Standard value by machine type:

MGW-J, MGW-K MGW-JP, MV-20 MGW-JP, MV-20

0110 0001B 0100 0001B 0100 0011B

Note: When the WORK ZERO RETURN function key or ORG key on FPB panel is turned on, the
message 2320 “Z WORK ZERO RETURN? yes:START KEY, no:RESET” is displayed.

2-23
Number Name Display Class Condition Standard value
0058 FUNC SELECTION 8 BIN SET RST Data by
Machine type

Explanation: Selects a function related to the machine sequence.

7 6 5 4 3 2 1 0 bit

Filter selection order in automatic mode ................................. Note 1)


0: Filter 1 → Filter 2 → Filter 1, 2
1: Filter 2 → Filter 1 → Filter 1, 2

Initializing condition for filter selection..................................... Note 1)


0: PUMP switch OFF
1: PUMP switch OFF, RESET

Waiting for work tank filling completion at the restart in M17 .. Note 2)
0: Not executed
1: Executed

After executing M59 (WORK TANK UP), TANK FILL is ......... Note 2)
0: Not executed
1: Executed

In the WATER mode (Set data No.106) that allows flushing only at
TANK FILL, Whether TANK FILL is executed by WATER
ON .......................................................................................... Note 2)
0: No (Warning stop)
1: Yes

WORK TANK UP control when TANK FILL is executed ......... Note 2)


0: TANK FILL starts after work tank is moved up so that the water
level reached the set height.
1: Only TANK FILL is executed without moving up or down the work
tank; when work tank is below tank fill inhibit height, warning is
output and operation stops.
W.TANK W.TANK MACH
Function switching of UP DOWN keys on OPE screen
................................................................................................ Note 2)
0: Alternate (ON when pressed once, and OFF when pressed
once more)
1: Momentary (ON only while key is pressed, and OFF when
released)

Non-movement M6 skip
0: Invalid
1: Valid (skip when non-movement M6 is specified and also a wire is
threaded)

2-24
Standard value by machine type:

MGW-J, MGW-K MGW-JP MV-20, MV-30

1000 0100B 0000 0000B 1000 0000B

Note 1: Bit 0 is valid only for the machines with an additional filter.
Note 2: Bits 2~6 are valid for PF32, U32, U53, EU64 (with tank filling + work tank up/down functions) only.

2-25
Number Name Display Class Condition Standard value
0059 FUNC SELECTION 9 BIN SET RST Data by
Machine type

Explanation : Select functions for the spinning axis (C axis) of UPH-1.

7 6 5 4 3 2 1 0 bit

MACHINE
Operation of index unit when HOME key is pressed
0: Not executed
1: Executed
WORK ZERO
Operation of index unit when RETURN key is pressed
0: Not executed
1: Executed
M6 POS.
Operation of index unit when RETURN key is pressed
0: Not executed
1: Executed
Operation of HOLDER CLAMP/UNCLAMP at the position other than
index unit at reference point
0: Not executed
1: Executed
Work tank up command (M59) during M6 search ................... Note 1)
0: Invalid
1: Valid

Single-touch functions Note 2) in the machine with the spinning axis


(C axis) are ............................................................................. Note 3)
0: Not skipped
1: Skipped

Before wire break/power failure recovery, single-touch functionsNote 2)


in the machine with the spinning axis (C axis) are.................. Note 3)
0: Not suspended
1: Suspended
Wire break check during automatic wire threading ................. Note 1)
0: Invalid
1: Valid
Standard value by machine type:

MGW-JP MV-20, MV-30 MGW-J, MGW-K

0000 0000B 1000 0000B 0010 0000B

Note 1: Bits 4 and 7 are valid for the MV-20 and MV-30 only.
MACHINE WORK ZERO M6 POS.
Note 2: The single-touch functions here refer to HOME , RETURN , and RETURN keys.
Note 3: Bits 5 and 6 are invalid for the MGW-JP, and MGW-K only.

2-26
Number Name Display Class Condition Standard value
0060 G91/G90 AT POWER ON BIN SET PWON Data by
Machine type

Explanation : Selects G91 or G90 when power is turned on.

– – – – – – – 0 bit

G91/90 when power is turned on


0: G90 (Absolute mode)
1: G91 (Incremental mode)

Standard value by machine type:

MGW-J, MV-20, MGW-K, MV-30 MGW-JP

0000 0001B 0000 0000B

Number Name Display Class Condition Standard value


0061 G01/G00 AT POWER ON BIN SET PWON 0000 0001B

Explanation : Selects G01 or G00 when power is ON.

– – – – – – – 0 bit

G01/G00 when power is turned on


0: G01 (Linear interpolation)
1: G00 (Rapid traverce)

2-27
Number Name Display Class Condition Standard value
0063 LINEAR AXIS COMAN UNIT BIN SET PWON Data by
Machine No.

Explanation : Selects command unit of linear axis. Note 1)

– – – – 3 2 – 0 bit

Command unit
0: Metric system
1: Inch system

Input resolution of command unit (program command) .......... Note 2)


0: Standard resolution
[10-3 mm] or [10-4] inch]
1: High resolution
[10-4 mm] or [10-5 inch]

Output resolution of command unit (screen display and input)


0: Standard resolution............................................................ Note 2)
[10-3 mm] or [10-4 inch]
1: High resolution
[10-4 mm] or [10-5 inch]

WORK ZERO
Note 1: If this setting is changed, always execute RETURN in manual mode.

Note 2: Bits 2 and 3 become active immediately after change.

Number Name Display Class Condition Standard value


0074 M98 FORMAT BIN SET INPT 0000 0000B

Explanation : Selects meaning and operation of subprogram call commands (M98, G27).

– – – – 3 2 – 0 bit

Meaning of P contained in M98


(P contained in G27 represents sequence No. only)
0: M98 O_P_R_ (P represents sequence No.)
1: M98 P_N_L_ (P represents program No.)

Operation when M99 is specified before Q_ in G27P_Q_ command


0: Ignores M99, and executes up to Q_, then returns to the main
program
1: Returns to the main program at the M99

2-28
Number Name Display Class Condition Standard value
0075 UV PLANE FUNCTION SELECTION HEX SET INPT Data by
Machine type

Explanation : Select whether the functions of X and Y axes in the vertical irregular shape machining are
to be extended to the U and V axes.

0: Not extended to the U and V axes


1: Extended to the U and V axes

F E DC B A 9 8 7 6 5 4 3 2 1 0 bit

Mirror image on the NC FUNC screen

Axis exchange on the NC FUNC screen

Coordinate system rotation command (G92A_)

Rotation copy command (G26)

Scaling command (G48)

Rotation command (G68)

Mirror image command (G71)

Axis exchange command (G73)

Standard value by machine type:

MGW-J, MV-20, MGW-K MGW-JP

00FFH 0000H

Note: This parameter is invalid for the MGW-JP.

2-29
Number Name Display Class Condition Standard value
0076 M08 CONTROL SELECTION BIN SET INPT Data by
Machine No.

Explanation : Definition and select the operation of remain/cut-off command (M08).

– – – – – 2 1 0 bit

After the movement before M00, divided length is


0: Not cut in cut-off part
1: Cut in cut-off part

After the movement before M01, divided length is


0: Not cut in cut-off part
1: Cut in cut-off part

After the movement before M91, divided length is


0: Not cut in cut-off part
1: Cut in cut-off part

Number Name Display Class Condition Standard value


0077 G95 Z AXIS POSI. MANEGEMENT MODE BIN SET INPT 0000 0000B

Explanation : Sets whether or not the Z axis is moved by (G95) Z axis position control command.

– – – – – – 1 0 bit

For automatic Z axis


0: Z axis moves to the position specified by G95
1: Z axis does not move (only the position information is changed)

For manual Z axis


0: Z axis is stopped by G95
1: Z axis is not stopped by G95

2-30
Number Name Display Class Condition Standard value
0078 M74 PROC. ADMINISTRATIVE FUNC. 1 BIN SET INPT 1100 0000B

Explanation : Select the functions on the DIAGNOSE, M74 screen.

7 6 5 4 3 2 1 0 bit

[Reserved]

Recording mode
0: All record mode (recording all machining data)
1: Skip record mode (recording skipped position only)

Administration mode
0: M74
1: M6

Processing after recording 300 data


0: Recording stop
1: Return to No.1, and restart

[Reverved]

Whether operation stops at the skipped position in the skipped


machining (additional machining).
0: Stop
1: Not stop

Whether operation stops at the start point (M6 point) of skipped


process in the skipped machining.
0: All of the machining is executed at the skipped position
1: Machining is skipped until the machining reached the failed Q
value concerned.

Whether the skipped machining is successful nor not is


0: Not judged
1: Judged

Number Name Display Class Condition Standard value


0079 M74 PROC. ADMINISTRATIVE FUNC. 2 BIN SET INPT 0000 0000B

Explanation : Select the function on the DIAGNOSE, M74 screen.

– – – – – – 1 0 bit

At the execution of AWC with the pallet magazine, M74P_ parameter


is
0: Not changed over
1: Changed over automatically

2-31
Number Name Display Class Condition Standard value
0081 CORNER INTERPOLATE BIN SET RST 0000 0000B

Explanation : Selects a corner interpolation method (outside) when the length of intersection vector
during radius compensation exceeds the value set by the parameter No.0082 (intersection
vector limit).

– – – – – 2 – 0 bit

Selection of corner interpolation method


0: Wire moves around a corner by linear interpolation .... Example 1)
1: Wire moves around a corner by circular interpolates... Example 2)

Selects approach block for radius compensation ............. Example 3)


0: Normal vector of start point in next block
1: Intersection of approach block and next block

Example 1: Wire moves around a corner by linear interpolation (Bit 0 = “0”)


1st

2st

1s t b
2s t
bloc

bloc

bloc
l oc k
k

Wire center path Wire center path

Program rounte Program rounte

If offset value is same If offset value (D1, D2) are different

Example 2: Wire moves around a corner by circular interpolation (Bit 0 = “1”)


1st b

2s t b
lo

Wire center path


lock
ck

Program rounte

Example 3: Selection of approach block for radius compensation

Wire center path Wire center path


Program rounte Program rounte

Bit 2 = “0” Bit 2 = “1”

2-32
Number Name Display Class Condition Standard value
0083 OFST LOCUS TANGLE SET DEC SET INPT 17

Explanation : Sets tolerance value in the case of judging whether or not 2 blocks are adjacent in the
calculation of radius compensation.

Setting range: 0~255

Unit : Depends on the value obtained from calculation method

Calculation method : Setting value = 1000 x tanθ (θ: Allowable angle)


θ = tan -1 (B/A) (For A and B, see below)

In calculation of radius
compensation, if the angle
1st block between 1st block and 2nd
block (1000 x B/A) is below
2nd block PRM0083 value, two blocks
Normal vector at the end point are judged adjacent, and the
of the 1st block wire moves as set by set
Normal vector at the start point data No. 84.
of the 2nd block
Program rounte Actual wire path

Number Name Display Class Condition Standard value


0085 APPROACH OFFSET VALUE DEC SET RST 0

Explanation : Set the approach offset value to prevent overcut of workpiece caused when a wire runs
through the same point in an approach block and a cancel block.

Setting range: ±99999999 (µm)

PRM display/input unit: Specified by system PRM No. 531

Number Name Display Class Condition Standard value


0086 CANCEL OFFSET VALUE DEC SET RST 0

Explanation : Set the approach offset value to prevent overcut of workpiece caused when a wire runs
through the same point in an approach block and a cancel block.

Setting range: ±99999999 (µm)

PRM display/input unit: Specified by system PRM No. 531

2-33
Number Name Display Class Condition Standard value
0091 G92 ROTATION ANGLE A1 DEC SET INPT 0
0092 G92 ROTATION ANGLE A2 DEC SET INPT 0
: : : : : :
: : : : : :
0099 G92 ROTATION ANGLE A9 DEC SET INPT 0

Explanation : Sets rotation angle of A0~A9 to be specified in the (G92A_) coordinate system rotation.

Setting range: ±360000 (±360°)

Unit : 0.001°

The original
coordinate
Rotated
coordinate

Note: Specify G92A0 when cancelling the rotated coordinates.

Number Name Display Class Condition Standard value


0100 AWT RETRY NO. DEC SET INPT 5

Explanation : Sets max. retry times of wire break automatic recovery function, within a one machining
process (Note).

Setting range: 0~127

Note: A one machining process: M06 (start) through M06 (reset).

2-34
Number Name Display Class Condition Standard value
0101 AWT FUNC SELECTION BIN SET INPT Data by
Machine type

Explanation : Selects the function related to the automatic wire threading (AWT).

7 6 5 4 3 2 1 0 bit

Processing after AWT retry over


0: Stop by warning
1: M6 search (dry run up to the next M6 point)

M6 operation of AWT SKIP OFF and DRY RUN ON...............Note 1)


00: Auto wire threading
01: Wire threading test (wire cut-off again)
10: Hole position test (JET on)
11: Not used

M6 operation at AWT SKIP ON and DRY RUN ON ................Note 1)


0: Manual wire threading (stop in midway)
1: M6 skip (equivalent to M6L1)

Lower jet interlocking at UNSPOOL WIRE and WIRE DRAW OUT


0: Invalid ..................Note 1)
1: Valid

(Length measuring function) Touch ignored after K-shaft .......Note 2)


0: Invalid
1: Valid

(Length measuring function) Advance work tank filling after K-shaft


0: Invalid ..................Note 2)
1: Valid

(Length measuring function) High speed wire feed after K-shaft


0: Invalid ..................Note 2)
1: Valid

Standard value by machine type:

MGW-JP, MV-20, MV-30 MGW-J, MGW-K

0000 0001B 1110 1101B

Note 1: Bits 1, 2, 3, and 4 are valid for the MGW-J and MGW-K.
Note 2: The length measuring function of bits 5, 6, and 7 is provided as standard for the MGW-K, or op-
tional for the U series of MGW-J, or invalid for other power supply units.

2-35
Number Name Display Class Condition Standard value
0102 ZRN AXES OF R.P.F AND R.W.B, RETURN BIN SET INPT Data by
FUNC Machine type

Explanation : Set a sequence of reference point return by the power failure recovery function, or the
return motion.

7 6 5 4 3 2 1 0 bit

Reference point return sequence ................................Note 1) Note 2)


00: XYUV simultaneous
01: XU simultaneous → YV simultaneous
10: YV simultaneous → XU simultaneous
Fixed wire break recovery condition (weak discharge condition)
0: Invalid
1: Valid
Return path
0: Return to retract start point via retract path
1: Return to retract start point linearly
Selection of return last block G01/G00
0: G01
1: G00
Warning at restart without return operation after the machining was
interrupted
0: Invalid
1: Valid
After reference point return, the axes
0: Do not return to the start position
1: Return to the start position
Reference point return is executed with the EXPAND STROKE key
turned on
0: Invalid
1: Valid

Standard value by machine type:

MGW-J, MV-20, MGW-K, MV-30 MGW-JP

0001 0000B 0001 0010B

Note 1: If 01 or 10 is set, return operation from reference point to M6 point is executed in the reverse
sequence of reference point return.
01: YV → XU 10: XU → YV
Note 2: Bits 0 and 1 are also referenced during the one-touch reference point return.

2-36
Number Name Display Class Condition Standard value
0103 W.BRK/POW.FAIL ACTIVE WATER MODE HEX SET INPT Data by
Machine type

Explanation: Sets valid/invalid of wire break/power failure recovery function for each water mode.

0: Auto wire break/power failure recovery function invalid


1: Auto wire break/power failure recovery function valid

F E DC B A 9 8 7 6 5 4 3 2 1 0 bit

Water mode 0

Water mode 1

Water mode 2

Water mode 3

Water mode 4

Water mode 5

Water mode 6

Water mode 7

Water mode 8

Water mode 9

Water mode 10

Water mode 11

Water mode 12
................................................. Note)
Water mode 13

Water mode 14

Water mode 15

Standard value by machine type:

MGW-J, MGW-JP, MV-20 MGW-K, MV-30

03FFH 0FFFFH

Note: Bits A~F are valid for the MGW-K and MV-30 only.

2-37
Number Name Display Class Condition Standard value
0104 W.BRK/POW.FAIL FINISH WATER MODE HEX SET INPT Data by
Machine type

Explanation : Switches recovery condition for rough machining condition or for finish machining condition
when machining condition returns from wire break recovery condition to original condition
during wire break/power failure recovery.

0: Wire break/power failure recovery for rough machining


1: Wire break/power failure recovery for finish machining

F E D C B A 9 8 7 6 5 4 3 2 1 0 bit

Water mode 0

Water mode 1

Water mode 2

Water mode 3

Water mode 4

Water mode 5

Water mode 6

Water mode 7

Water mode 8

Water mode 9

Water mode 10

Water mode 11

Water mode 12
................................................. Note)
Water mode 13

Water mode 14

Water mode 15

Standard value by machine type:

MGW-J, MGW-JP, MV-20 MGW-K, MV-30

0018H 0180H

Note: Bits A~F are valid for the MGW-K and MV-30 only.

2-38
Number Name Display Class Condition Standard value
0105 ROUGH CUT WATER MODE HEX SET INPT Data by
Machine type

Explanation : Switches the conditions for rough machining or finish machining according to the water
mode.

0: Water mode for finish machining


1: Water mode for rough machining

F E DC B A 9 8 7 6 5 4 3 2 1 0 bit

Water mode 0

Water mode 1

Water mode 2

Water mode 3

Water mode 4

Water mode 5

Water mode 6

Water mode 7

Water mode 8

Water mode 9

Water mode 10

Water mode 11

Water mode 12
................................................. Note)
Water mode 13

Water mode 14

Water mode 15

Standard value by machine type:

MGW-J, MGW-JP, MV-20 MGW-K, MV-30

00E7H 007FH

Note: Bits A~F are valid for the MGW-K and MV-30 only.

2-39
Number Name Display Class Condition Standard value
0106 FLUSHING ALLOWABLE WATER MODE HEX SET RST Data by
AT TANK FILL Machine type

Explanation : Set water mode that allows flushing when tank is full in a submerged machining.

0: Flushing allowed even if tank fill is OFF


1: Flushing allowed during tank filling

F E D C B A 9 8 7 6 5 4 3 2 1 0 bit

Water mode 0

Water mode 1

Water mode 2

Water mode 3

Water mode 4

Water mode 5

Water mode 6

Water mode 7

Water mode 8

Water mode 9

Water mode 10

Water mode 11

Water mode 12
................................................. Note)
Water mode 13

Water mode 14

Water mode 15

Standard value by machine type:

MGW-J MGW-JP, MV-20 MGW-K, MV-30

03FFH 0000H 0FFFFH

Note: Bits A~F are valid for the MGW-K and MV-30 only.

2-40
MGW-K, MV-30
(Not registered for MGW-J, JP and MV-20)
Number Name Display Class Condition Standard value
0107 HEIGHT OOF SOLUTION SURFACE DEC SET INPT 1000
(UNIT 1 mm, 0.1 inch)

Explanation : Set the fluid level from the table surface when work tank is full.

Setting range: –100 to 1600

Fluid level
Set value
Work tank

Table

2-41
Number Name Display Class Condition Standard value
0135 FUNC. SELECTION 10 BIN SET INPT Data by
Machine type

Explanation : Select the operation for optional functions of UPH series.

7 6 5 4 3 2 1 0 bit

When executing M60C_, X~Z axis return operation after index


00: Invalid (axes stop at reference point after index)
01: Retrun to the point before index (X~Z axis position when
M60C_ command was specified)
10: Return to the start point of last M60C_ command operation
11: Invalid (X~Y axes do not operate at reference point or not
return)
X~Z axis return operation after M60P1 was executed
0: Invalid (Return operation is not executed)
1: Valid (Return operation is executed; the contents of return
operation follow the setting of bits 0 and 1)
Index head manual operation and G91G1Cxx operation are . Note 1)
0: Invalid (Compatible with conventional function + M60 command
only)
1: Valid (Compatible with conventional function+ Manual operation +
G91G1Cxx)
Command to select AWC work change modes AWC
0: Conventional system (selection by turning on/off RANDOM key
on the MACH OPE, AWC screen)
1: Free change mode (using M66/67/68 commands can select the
sequential or random mode)
At the start of AWC M codes (M66~M68), the wire is
0: Not cut off
1: Cut off
On the chuck fixed type spinning head, at M63 (rotation ON), the
coolant is turned...................................................................... Note 2)
0: OFF
1: ON
On the index unit, X~Z axes return in the “MACHINE HOME”/AWC/wire
break recovery operation, or reference point return of index unit is
0: Not executed
1: Executed
On the chuck fixed type spinning head, at M63Sxx, the work tank
0: Does not move up
1: Moves up

Note 1: The bit 3 becomes valid by the reset operation.


Note 2: Bit 6 (Coolant ON/OFF) is valid only when bit 7 is set to “1” (Work tank up).
Note 3: Only the bits 0 and 1 are valid for the MV-20 (UPH-1).

2-42
Standard value by machine type:

MV-30 MV-30
MGW-J, MGW-JP, MV-20, MGW-K
(with standard/spining head) (with index unit)

0000 0000B 1101 1000B 0101 1000B

Number Name Display Class Condition Standard value


0136 FUNC. SELECTION 11 BIN SET INPT Data by
Machine type

Explanation : Select the functions for machine sequence.

7 6 5 4 – 2 1 0 bit

Tank filling and measuring function


0: Invalid
1: Valid
Warning stop before tank filling and measurement start
0: Invalid
1: Valid
In case of operation stop by M00 or M01,
0: TANK FILL is not turned off
1: TANK FILL is turned off
Angle designation for the “HOLE CENTER” operation
0: Angle designation is invalid
1: Angle is measured with the rotation angle on the OFFSET screen
During measurement, the wire feed is
0: Executed during the measurement
1: Not executed during the measurement
In AWC operation on the machine with index unit, if current index
position is same as AWC retract position (machine PRM No.6071)
....Note)
0: Reference point return is executed even if same position
1: Reference point return is not executed if same position
(for reduction of AWC time)
On the index unit, during power failure recovery/wire break recovery/
AWC operation, whether the index unit is stopped or not to prevent
interference (UPH-2/UH-2)
0: Not stopped
1: Stopped (Warning 2838)

Standard value by machine type:

MGW-J MGW-K MV-20, MV-30, MGW-JP

0000 0010B 0000 0011B 0000 0000B

Note: The function set by bit 5 becomes valid when the set data No.135 bit 5=1.

2-43
MGW-J, MGW-K, MV-20, MGW-JJP
Number Name Display Class Condition Standard value
0137 FUNC. SELECTION 12 BIN SET INPT Data by
Machine type

Explanation : Select the functions for the submerged auto wire threading (AWT).

7 6 5 4 3 2 1 0 bit

(Beginning) Submerged AWT in M6 at M6 point


0: Not executed
1: Executed

(Beginning) Submerged AWT in wire break/power failure recovery at


M6 point
0: Not executed
1: Executed

(Beginning) Submerged AWT in M75 reference hole retry


0: Not executed
1: Executed

(Midway) Time extension (in Retry 0/1/3 mode)


0: Not executed
1: Executed

(Midway) Time extension (in Retry 2 mode)


0: Not executed
1: Executed

(Midway) Submerged AWT during time extension (in Retry 0/1/3


mode)
0: Not executed
1: Executed

(Midway) Submerged AWT during time extension (in Retry 2 mode)


0: Not executed
1: Executed

(Next time) Submerged AWT after submerged AWT failed (until reset)
0: Not executed
1: Executed

Standard value by machine type:

MGW-J, MGW-K MV-20, MGW-JP

1001 1011B 0000 0000B

2-44
Number Name Display Class Condition Standard value
0138 FUNC. SELECTION 13 BIN SET INPT Data by
Machine type

Explanation : Select the functions related to the high speed M6.

7 6 5 4 3 2 1 0 bit

High speed M6 function


0: Invalid
1: Valid

AWT Retry mode with valid high speed M6


0: Only Retry 3 valid
1: All modes valid

High speed M6 even in wire break/power failure recovery


0: Invalid
1: Valid

Wire diameter with valid high speed M6


0: Over 0.16mm
1: All diameters

Check before wire cut at high speed M6


0: Executed
1: Not executed (wire is always cut)

Z axis shift at submerged AWT with high speed M6


0: Executed
1: Not executed

Fill height return waiting at high speed M6


0: Executed
1: Not executed

Check after AWT at high speed M6


0: Executed
1: Not executed

Standard value by machine type:

MGW-J, MGW-K MV-20, MV-30, MGW-JP

1110 0001B 0000 0000B

2-45
Number Name Display Class Condition Standard value
0139 FUNC. SELECTION 14 BIN SET INPT 0001 0000B

Explanation : Select the functions related to the machine sequence.

7 6 5 4 3 2 1 0 bit

ON or OFF of wire edge regeneration sequence


0: OFF
1: ON

Wire edge regeneration sequence; processing if the wire touches the


workpiece after the Z axis rises to draw the wire off the workpiece
00: Select whether a warning stop is executed or not depending on
the taper angle. If taper angle is 0, the wire is rewound. If larger
than 0, the operation is warning-stopped, and at the restart, AWT
is executed after returning to M06 position.
01: If the wire touches the workpiece, the operation is stopped, and
at the restart, AWT is executed after returning to M06 position.
11: The wire is rewound without a stop, and the wire edge
regeneratio processing is executed.

M75 reference hole retry 2


0: Invalid
1: Valid

Wire edge regeneration sequence; a method to move to the wire edge


regeneration position
0: Touch sensing is not executed.
1: If the wire touches the workpiece, the operation is stopped, and at
the restart, AWT is executed after returning to M06 position.

Function keys M6/M7 during MEM RUN stop status


0: Invalid
1: Valiid

Slitted initial hole AWT during wire break/power failure recovery


0: Invalid
1: Valiid

Slitted initial hole AWT


0: Invalid
1: Valiid

Standard value by machine type:

MGW-J, MGW-K MV-20, MV-30, MGW-JP

0001 0000B 0000 0000B

2-46
Number Name Display Class Condition Standard value
0140 CUSTOM G/M/T NO.1 DEC SET INPT 0
(COMMAND CODE)
0141 CUSTOM G/M/T NO.1 DEC SET INPT 0
(O NUMBER)
0142 CUSTOM G/M/T NO.2 DEC SET INPT 0
(COMMAND CODE)
: : : : : :
: : : : : :
0170 CUSTOM G/M/T NO.16 DEC SET INPT 0
(COMMAND CODE)
0171 CUSTOM G/M/T NO.16 DEC SET INPT 0
(O NUMBER)

Explanation : Defines the pseudo command code for the custom macro and O number called by that
code; as a set of two parameters, maximum 16 codes can be defined.

[Defining command code (Even set data No.140, 142, ..., 170)]
Explanation : Define pseudo command code address (G/M/T), calling method (with/without parameter)
and code No. (0~999) with 5-digit value.

Setting range: 0~32767

Setting contents: 2 1 2 0 0

Code No.: 000~999

Calling method
0: G65 (without parameter)
1: G65 (with parameter)
2: M98

Command code address


1: G code
2: M code
3: T code

[Defining O number (Odd set data No.141, 143, ..., 171)]


Explanation : Define O number of a subprogram called by the command code defined by the first
parameter.

Setting range: 0~9999

2-47
Example 1 : If M200F50; command is programmed in O9200
Set data No. 140 = 21200
Set data No. 141 = 9200
Example 2 : If M201; command is programmed in O8201
Set data No. 142 = 10201
Set data No. 143 = 8201

Note: If these parameters are already used for another pseudo codes, use the other parameters.

Number Name Display Class Condition Standard value


0175 MACRO DRAWING SCREEN DRAWING DEC SET INPT 8000
O No. (1)
0176 MACRO DRAWING SCREEN DRAWING DEC SET INPT 8000
O No. (2)

RUN MAC MAC


Explanation : Selects O No. to be drawn on the , DRAW2 screen.
PROG DRAW1

Setting range: 0~14999

Number Name Display Class Condition Standard value


0177 MODEL MASTER BLOCK O No. DEC SET INPT 0

Explanation : On the Model Plan version 2, routine input items are registered with O No. in advance
separately from O No. to be edited, then they are automatically read when the Model Plan
is opened.

Setting range: 0~9999

Number Name Display Class Condition Standard value


0179 SUBMODEL SCREEN MENU O No. DEC SET INPT 8100

Explanation : Set O No. on initial menu screen of sub model.

Setting range: 0~14999

2-48
Number Name Display Class Condition Standard value
0180 TIME COUNTER FUNC BIN SET INPT 0001 0011B

Explanation : Selects the time counter function.

0: Valid 1: Invalid
– – – 4 – 2 1 0 bit

Clearing total machining time (RUN TIME screen)


0: Invalid
1: Valid

Clearing auto run time (RUN TIME screen)


0: Invalid
1: Valid

Clearing power On time (RUN TIME screen)


0: Invalid
1: Valid

Clearing machining time (MC TIME screen)


0: Invalid
1: Valid

Number Name Display Class Condition Standard value


0182 MACHINING HISTORY MODE BIN SET INPT 0000 0010B

Explanation : Selects a function related to the machining trace recording.

– – – – – – 1 0 bit

Clearing MC trace recording


0: Invalid
1: Valid

Processing after recording 200 events of machining history


0: Stop at recording of 200 events
1: Screen is scrolled up for latest event recording after recording 200
events

2-49
Number Name Display Class Condition Standard value
0301 SUBMERGED A.W.T. FUNC/M73 DEC SET INPT Data by
FLUSHING ON (UPH) Machine No.

Explanation : For the UPH-1, UPH-2 and UH-2, set the Z axis moving amount when optional core remov-
ing function is performed with the WATER turned ON.
For the power supply units other than MGW-JP, MV-20 and MV-30, set the Z axis upper
limit in the submerged AWT operation. If the Z axis machine coordinate exceeds the value
set here, the submerged AWT is disabled.
(Refer to the set data No.56 bit 7, No.137)

Setting range: ±99999999

Unit : PRM display/input unit (system PRM No.531)

Standard value by machine type:

MGW-J, MGW-K MV-20, MV-30 MGW-JP

30000 Data by machine No. 0

Note: This set data is valid for the MV-20, MV-30, MGW-J and MGW-K only.

Number Name Display Class Condition Standard value


0325 NONCONTACT POINT SEARCH MODE BIN SET INPT 0000 1000B

Explanation : Set the search function.

– – – – 3 2 1 0 bit

Noncontact point search by M200


0: Invalid
1: Valid

Noncontact point search by M17


0: Invalid
1: Valid

Centering after completion of search


0: Invalid
1: Valid

Return to search start point


0: Stop after completion search and return at G00 speed by restart
1: Return while the machining is executed

2-50
Number Name Display Class Condition Standard value
0326 NONCONTACT POINT SEARCH PLANE BIN SET INPT 0000 0011B

Explanation : Set the search plane.

– – – – 3 2 1 0 bit

YX plane search
1: Execute
0: Not executed

UV plane search
1: Execute
0: Not executed

(After XY plane search, the UV plane search is executed if the touch sensor has not been turned off yet.)

Number Name Display Class Condition Standard value


0327 NONCONTACT POINT SEARCH PITCH DEC SET INPT 50
0328 NONCONTACT POINT SEARCH LIMIT DEC SET INPT 500

Explanation : Set the pitch and limit of the noncontact point search.

Setting range: 0~99999999

Unit : PRM display/input unit (system PRM No.0531)

Number Name Display Class Condition Standard value


0330 APPROACH PATH LENGTH DEC SET RST Data by
Machine type

Explanation : Set the length from start of discharge up to the point where the discharge condition returns
to initial set value.

Setting range: 0~15000 (µm)

Unit : PRM display/input unit (system PRM No.0531)

2-51
Standard value by machine type:

MGW-J, MGW-JP, MGW-K MV-20, MV-30

5000 1000.

Note: Set a smaller value to this set data if the approach block (a block before a profille machining) is
short.
Reduce the machining power of approach machining conditions to prevent wire break. As a result,
the wire delay amount is less and the overcut could occur in the G44 (profile compensation). Also,
the discharge gap changes, generating steps on machined surface.

Number Name Display Class Condition Standard value


0336 CONDITION PROTECT BIN SET INPT 0000 0000B

Explanation : Select whether rewriting/deletion of standard and user machining conditions is disabled or
enabled.

7 – – 4 3 2 1 0 bit

Rewriting of standard condition elements is


0: Disabled
1: Enabled

Rewriting of user condition elements is


0: Disabled
1: Enabled

Deletion of user condition elements is


0: Disabled
1: Enabled

Deletion of standard condition elements is


0: Disabled
1: Enabled

Setting of bits 0-3 at power on is


0: Kept unchanged
1: Reset to “0”

Reference wire diameter at copying of condition


0: Wire diameter on COND SUB screen
1: Current wire diameter

2-52
MGW-K, MV-30 (Not registered for MGW-J, MGW-JP and MV-20)

Number Name Display Class Condition Standard value


0380 MASKING MC COND ELEMENTS (1) HEX SET INPT See below
0381 MASKING MC COND ELEMENTS (2) HEX SET INPT See below
: : : : : :
: : : : : :
0394 MASKING MC COND ELEMENTS (15) HEX SET INPT See below

Explanation: Set valid or invalid of masking for the elements on COND screen.

0: Invalid 1: Valid

F E D C B A 9 8 7 6 5 4 3 2 1 0 bit

Valid/invalid of mask function for element No.1, 5, 9, 13, 17, 21,


25, 29, 33, 37, 41, 45, 49, 53, 57
Bits 0: COND MAIN screen
Bits 1: COND SUB screen
Bits 2: COND LIST screen
Bits 3: Not used

Valid/invalid of mask function for element No.2, 6, 10, 14, 18,


22, 26, 30, 34, 38, 42, 46, 50, 54, 58
Bits 4: COND MAIN screen
Bits 5: COND SUB screen
Bits 6: COND LIST screen
Bits 7: Not used

Valid/invalid of mask function for element No.3, 7, 11, 15, 19,


23, 27, 31, 35, 39, 43, 47, 51, 55, 59
Bits 8: COND MAIN screen
Bits 9: COND SUB screen
Bits A: COND LIST screen
Bits B: Not used

Valid/invalid of mask function for element No.4, 8, 12, 16, 20,


24, 28, 32, 36, 40, 44, 48, 52, 56, 60
Bits C: COND MAIN screen
Bits D: COND SUB screen
Bits E: COND LIST screen
Bits F: Not used

2-53
Contents of setting:

Element No.
No.
Bits F/E/D/C Bits B/A/9/8 Bits 7/6/5/4 Bits 3/2/1/0
0380 4:MODE 3:W.THICKNESS 2:W.MATERIAL 1:WIRE DIA.
0381 8:OND 7:ONC 6:ONB 5:ONA
0382 12:RCT 11:SCT 10:TS 9:OFF
0383 16:RV 15:SV 14:DCHG - R 13:DCHG - S
0384 20:SV.No. 19:SV.MODE 18:IPS 17:IPM
0385 24:RPG - ON 23:SM - REF 22:SPEED 21:SV.ADJ
0386 28:ADC 1 - 1 27:ADC 0 - 2 26:ADC 0 - 1 25:ADC - ON
0387 32:WATER MODE 31:(NOT USED) 30:(NOT USED) 29:ADC 1 - 2
0388 36:TENSION 35:WIRE FEED 34:OVERRIDE L 33:OVERRIDE U
0389 40:PRG 0 - 1 39:EST.SPEED 38:MC TYPE 37:W.COND.
0390 44:PRG 1 - 1 43:PRG 0 - 4 42:PRG 0 - 3 41:PRG 0 - 2
0391 48:PRG 3 - 2 47:PRG 3 - 1 46:PRG 2 - 2 45:PRG 2 - 1
0392 52:ADC 3 - 2 51:ADC 3 - 1 50:ADC 2 - 2 49:ADC 2 - 1
0393 56:ADC 5 - 2 55:ADC 5 - 1 54:ADC 4 - 2 53:ADC 4 - 1
0394 60:(NOT USED) 59:(NOT USED) 58:(NOT USED) 57:(NOT USED)

Standard set value:

Standard value
No.
MGW-K MV-30
0380 1000H 1000H
0381 1111H 1111H
0382 1111H 1111H
0383 1111H 1111H
0384 1111H 1111H
0385 1111H 1111H
0386 1111H 1111H
0387 0FF1H 0FF1H
0388 0000H 0000H
0389 10F0H 10F0H
0390 1111H 1111H
0391 FF11H FF11H
0392 FF11H FF11H
0393 FFFFH FFFFH
0394 FFFFH FFFFH

2-54
Number Name Display Class Condition Standard value
0400 SWITCHING WIRE PATH WIRE DIAMETER DEC SET INPT 80

Explanation : Sets the wire diameter with which optional thin wire feed system and standard wire feed
system is switched.

Setting range: 0~8000 (µm)

Unit : PRM display/input unit (system PRM No.531)

Note: Not used

Number Name Display Class Condition Standard value


0420 NON-DISCHARGE FEED CONT. WATER DEC SET RST Data by
MODE 0 Machine type
0421 NON-DISCHARGE FEED CONT. WATER DEC SET RST Data by
MODE 1 Machine type
: : : : : :
: : : : : :
0429 NON-DISCHARGE FEED CONT. WATER DEC SET RST Data by
MODE 9 Machine type

Explanation : Set the feedrate to be controlled under non-discharge condition in each water mode.

Setting range: 0~400

Unit : mm/min or 0.1 inch/min specified by system parameter No. 531.

Standard value by machine type:

MGW-J, MGW-JP, MGW-K MV-20, MV-30

100 20

2-55
MGW-K, MV-30 (Not registered for MGW-J, JP and MV-20)

Number Name Display Class Condition Standard value


0430 NON-DISCHARGE FEED CONT. WATER DEC SET RST 100
MODE 10
0431 NON-DISCHARGE FEED CONT. WATER DEC SET RST 100
MODE 11
: : : : : :
: : : : : :
0435 NON-DISCHARGE FEED CONT. WATER DEC SET RST 100
MODE 15

Explanation : Set the feedrate to be controlled under non-discharge condition in each water mode.

Setting range: 0~400

Unit : mm/min or 0.1 inch/min specified by system parameter No. 531.

Number Name Display Class Condition Standard value


0471 SCHEDULE LIST SCREEN DEC SET INPT 0

Explanation : Set a drawing macro O No. to be started for data display when SCHEDULE LIST screen
is opened. (Note)

Setting range: 0~14999

Note: If this parameter is set to “0”, the drawing macro O number is not started.

Number Name Display Class Condition Standard value


0472 SCHEDULE RUNNING DUMMY DEC SET INPT 0

Explanation : Set O No. to be started at the start of process in the schedule run. (Note)

Setting range: 0~14999

Note: If this parameter is set to “0”, O/N No. on the SCHEDULE LIST screen is started directly.

2-56
Number Name Display Class Condition Standard value
0473 SCHEDULE PROCESS STORING DEC SET INPT 0

Explanation : Set a macro program O No. for data check to be started by registration during editing of
schedule data. (Note)

Setting range: 0~14999

Note: If this parameter is set to “0”, a macro program is not called, but only a checking of O No. input and
registration in the schedule list is made.

Number Name Display Class Condition Standard value


0474 SCHEDULE RUNNING OPEN DEC SET INPT 0

Explanation : Set O No. to be started when the schedule run is started.

Setting range: 0~14999

Number Name Display Class Condition Standard value


0475 SCHEDULE RUNNING CLOSE DEC SET INPT 0

Explanation : Set O No. to be started when the schedule run is finished.

Setting range: 0~14999

Number Name Display Class Condition Standard value


0476 SCHEDULE PROCESS OPEN DEC SET INPT 0

Explanation : Set O No. to be started before starting it in the schedule run. (Note)

Setting range: 0~14999

Note: If this parameter is set to “0”, the drawing macro O number is not started.

2-57
Number Name Display Class Condition Standard value
0477 SCHEDULE PROCESS CLOSE DEC SET INPT 0

Explanation : Set O No. to be started after a program execution was finished in the schedule run. (Note)

Setting range: 0~14999

Note: If this parameter is set to “0”, the drawing macro O number is not started.

Number Name Display Class Condition Standard value


0478 SCHEDULE PROCESS DATA EDIT DEC SET INPT 0

Explanation : O number to be started when editing schedule data (Note)

Setting range: 0~14999

Note: If this parameter is set to “0”, the drawing macro O number is not started.

Number Name Display Class Condition Standard value


0479 SCHEDULE PROCESS PROTECT BIN SET INPT 0FEH

Explanation : Set a process that can be deleted/automatically by the schedule function.

0: Process is not deleted/automatically


1: Process is deleted/automatically

– – 5 4 3 2 1 0 bit

Start process

Stored

Prepare

Machining

Finish process

Break process