Data Sheet VA521 en
Data Sheet VA521 en
Data Sheet VA521 en
With keystroke:
• Reset counter
• Select units
• Parameterize interface
Measuring ranges flow VA 521 (Max version 185 m/s) for compressed air (ISO 1217: 1000 mbar, 20 °C).
Measuring ranges for other gas types see pages x to x
Measuring Thread Measuring range L B H1 H A A
section m³/h cfm mm mm mm mm mm mm
DN 15 G 1/2“ 90 m³/h 50 135 55 50 109.65 25 20
DN 20 G 3/4“ 170 m³/h 100 135 55 50 109.65 26 20
DN 25 G 1“ 290 m³/h 170 135 55 50 109.65 33 25
DN 32 G 1 1/4“ 530 m³/h 310 135 80 80 215.45 35 25
The sensor can be removed DN 40 G 1 1/2“ 730 m³/h 430 135 80 80 215.45 36 25
from the measuring block and
cleaned DN 50 G 2“ 1195 m³/h 700 135 80 80 215.45 44 30
1 www.cs-instruments.com
Flow
Calibration
No real gas adjustment - gas type setting by gas
D1
constant
D2 Real gas calibration in the gas type selected below
Order-No. VA 521
Gas type
DESCRIPTION ORDER-NR.
E1 Compressed air
Compact inline flow sensor 0696 0521 +
E2 Nitrogen (N2)
order code A_...R_
E3 Argon (Ar)
E4 Carbon dioxide (CO2) Further accessories see page 82 bis 86
E5 Oxygen (O2) TECHNICAL DATA VA 521
E6 Nitrous oxide (N2O)
Parameters: m³/h, l/min (1000 mbar, 20 °C) in case
E90 Further gas / please indicate gas type (on request) of compressed air resp. Nm³/h, Nl/min
E91 Gas mixture / please indicate mixture ratio (on request) (1013 mbar, 0°C) in case of gases
Measuring range (see table) Units adjustable via keys m³/h, m³/min, l/min, l/s, ft/min, cfm,
at display: m/s, kg/h, kg/min, g/s, lb/min, lb/h
F1 Low Speed version (50 m/s)
F2 Standard version (92,7 m/s) Sensor: Thermal mass flow sensor
F3 Max version (185 m/s) Meas medium: Air, gases
F4 High Speed version (224 m/s) Gas types over Air, nitrogen, argon, CO2, oxygen
CS Service Software or
Reference standard
CS Datalogger
G1 20 °C, 1000 mbar adjustable:
G2 0 °C, 1013,25 mbar
Measuring range: See table
G3 15 °C, 981 mbar
G4 15 °C, 1013,25 mbar Accuracy: ± 1,5 % of m. v. ± 0,3 % of f. s.
(f. M. = from the measu- By request:
Option display red value) ± 1 % of m. v. ± 0,3 % of f. s. or
H1 with integrated display (f. E. = from end value) ± 6 % of m. v. ± 0,5 % of f. s.
H2 without display Pressure measurement: 0...16 bar, accuracy: 1%
Option signal / bus connection Digital output: RS 485 interface (Modbus RTU),
(optional) M-Bus, Ethernet interface
1x 4...20 mA analog output not galvanically isolated,
J1 or PoE
pulse output, RS 485 (Modbus RTU)
Ethernet-Interface (Modbus/TCP), 1 x 4...20mA analog Analog output: 4...20 mA for m³/h resp. l/min
J2
output not galvanically isolated, RS 485 (Modbus RTU)
Ethernet-Interface Power over Ethernet (Modbus TCP), Pulse output: 1 pulse per m³ or per liter galvanically
J3 1 x 4...20mA analog output not galvanically. isolated, RS isolated. Pulse value adjustable on
485 (Modbus RTU) the display. Alternatively, the pulse
M-Bus, 1 x 4...20mA analog output not galvanically isola- output can be used as an alarm relay.
J4
ted, RS 485 (Modbus RTU) Power supply: 18...36 VDC, 5 W
Flow straightener Burden: < 500 Ω
with integrated flow straightener, no additional Housing: Polycarbonate (IP 65)
K1
inlet pipe necessary (with measuring block 1/2" to 2")
Meas. section: Aluminium, 316L
Mounting thread meas. G 1/2“ to G 2“ (BSP British standard
section: piping) resp. 1/2“ to 2“ NPT-thread
Mounting position: Any
www.cs-instruments.com 2