FCZ P Fan coils


concealed installation

Aermec is participating in the


EUROVENT Program : FCH The
related products can be found at the
website
www.eurovent-certification.com

• FULLY SILENT FUNCTIONING


• FULL COMFORT: REDUCED TEMPERATURE AND
RELATIVE HUMIDITY OSCILLATIONS
• IDEAL ALSO FOR DUCTED INSTALLATION

Features

Drawing from its wide experience in the field of fan Versions Without control in built, equipped with Plasmacluster purifier
coils, Aermec presents the new series FCZ_P for Vertical or horizontal installation: • Extractable shrouds for easy, effective cleaning
duct installations. FCZ_P • The hydraulic connections can be inverted
They can be installed on any system with 2/4 pipe FCZ_PO during installation (only valid for units with a sin-
and it fits with any heat generator even at low tem- FCZ_PPC gle coil, those with a supplementary coil cannot
peratures, and thanks to varied versions and set- be inverted).
tings, it is easy to pick the ideal solution for any • 3-speed ventilating unit.
need. • Electric motors with permanently inserted con-
densers
• Low loss of charge in the heat exchanger
• Easy installation and maintenance
G2 air filter for all versions. APC versions is

Versions Description

Versions

• FCZ_P
- Concealed without cabinet

• FCZ_PPC
- Concealed with Plasmacluster purifier
Duct
Vertical • FCZ_PO
- Concealed (ideal also for ducted installation)

Vertical or horizontal installation


- For 2/4 pipe system

Horizontal
Choosing the unit
By appropriately combining the variety of options available, each model can be configured in order to meet all specific system requirements.

Field Code 7,8 Versions


1,2,3 FCZ P Concealed mounted without cabinet
4 Size PO Concealed with oversized motor
1-2-3-4-5-6-7-8-9-10 PPC Concealed with Plasmacluster purifier
5 Maincoil
0 Standard
5 Oversized (1)
6 Supplementary coil
0 Without heat exchanger
1 Standard
2 Oversized

(1) Oversized coil "5" does not allow the installation of the supplementary coil "1 or 2"

Size available for version


Versions Size available with main coil only (2 pipes)
FCZ 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000
P • • • • • • • • • • • • • • • • • • •
PO / / • • • • • • • • • • • • / / • • /
PPC • • • • • • • • • • • • • • • • • • •

Versions Size available with main and supplementary coil (4 pipes)


FCZ 101 102 201 202 301 302 401 402 501 502 601 602 701 702 801 802 901 1001
P • • • • • • • • • • • • • • • • • •
PO / / • • • • • • • • • • • • / • • /
PPC / / / / / / / / / / / / / / / / / /

Accessories

Control panel - VMF-SW1: Additional water sensor for 4-pipe systems with circular sections.
A range of dedicated controllers, wall-mounted or on E1 thermostats offering maximum control in the cooling • RD: Straight flow fitting for ducting.
the machine, is available but it is essential to choose range. • RDA: Straight intake fitting for ducting.
• RP: 90° flow fitting for ducting
between these panels for simple and complete tuning,
Hot water coil • RPA: 90° intake fitting for ducting.
for more details please refer to the dedicated sheet. • BV: Single row hot water heat exchanger. Not available for
versions with Plasmacluster. DUCTING ACCESSORIES
Probes and accessory for control panels
• SW3: water temperature probe allowing automatic sea- • RDA_V: Straight intake connection with rectangular
Electrical heater flange.
son change on electronic controllers supplied with
• RX: Armoured electrical coil with safety thermostat (requires • RDAC_V: Straight intake connection with circular
water-side change over
a thermostat with heater management). Not available for flanges.
• SWA: external probe accessory (length = 6m). The probe 4-row or Plasmacluster versions
detects the temperature of the ambient air if connected • RPA_V: Intake plenum with rectangular flange.
to the connector (A) on panel FMT21; the ambient air • RDMC_V: Straight discharge with circular flanges.
Valve kit Internally insulated.
temperature probe incorporated in the panel is automa- • VCZ_X4: Valve kits for single coil units, installed in 4
tically deactivated. Detects the temperature of the water • PA_V: Intake plenum with circular flanges. Flanges in
pipe systems with totally separated "Cooling" and plastic material.
in the system, for ventilation consent, if connected to the "Heating" circuits. The kit consists of 2 valves with 3-way
connector (W) of the FMT21 panel. Two SWA probes can • RPM_V: Discharge plenum with rectangular flange.
4 port connection complete with electro-thermal actua- Internally insulated.
be simultaneously connected to the panel FMT21. tors, insulating shells for the valves and associated • PM_V: Discharge plenum with circular flanges.
• SIT 3 - 5: Thermostat Interface Card allowing the crea- hydraulic piping. The VCF1X4L valve kit allows left side Internally insulated. Flanges in plastic material.
tion of a network of fan coils (max. 10) commanded by a connection. • KFV10: Circular flanges kit for intake/discharge ple-
central control panel (selector or thermostat). • VCZ or VCF: kit containing a motorised 3-way valve with num.
SIT3: commands the 3 fan speeds and must be installed insulating shell plus coupling and pipes in insulated cop-
on each fan coil within the network; receives the com- per. Applicable for standard or oversized main coil. Grid
mands from the selector or the SIT5 card. Available with 230V and 24V~50Hz power supply. • GA: Intake grid with fixed louvers.
SIT5: commands the 3 fan speeds and up to 2 valves (four • VCZD or VCFD: Kit consisting of powered 2-way valve, • GAF: Intake grid with fixed louvers with filter.
pipe systems); sends the thermostat's commands to the copper couplings and pipes applicable for standard or over- • GM: Flow grid with adjustable louvers.
fan coil network. sized main coil. Available with 230V and 24V~50Hz power
supply. For more details on the control panels and VMF system refer to
VMF system the dedicated sheet
- VMF-E0: Thermostat accessory to be mounted on Accessory for Installation
the side of the fancoil, equipped with air and water • AMP: kit for the wall mounting installation.
sensors as standard; controls 2 pipe, 4 pipe, • BC: Auxiliary condensate drip tray.
2 pipe + Plasmacluster, 2 pipe + UV lamps, • CHF: The VentilCassaforma is a galvanised sheet steel tem-
2 pipe + electrical heater systems. Equipped with plate, for P versions, which allows you to obtain a space for
external contact to be used as low voltage remote housing the fan coil, directly in the wall.
ON-OFF. This thermostat can create a single fancoil • DSC4: Condensate drainage device for use when natural
zone through 2-wire serial communication (1 master + run-off is not possible.
maximum 5 slaves). The thermostat is fuse protected. • PA: Galvanised sheet steel intake plenum equipped with
- VMF-E4: Wall mounted user interface allowing control via intake fittings for circular section ducts.
a capacitive touch keyboard. • PA-F: Intake plenum, which allows recovery and flow on
- VMF-E5: Wall recessed panel allowing control of a comple- the same side. It is suitable for all those installations out-
te hydronic system via a capacitive touch keyboard. side air-conditioned rooms, in order to minimise noise
- VMF-E1: Thermostat for serial communication. and facilitate maintenance operations.
- VMF-SW: Water sensor replacing that supplied with VMF- • PM: Galvanised sheet steel flow plenum, externally insu-
E1 thermostats for installation upstream of the valve. lated, equipped with plastic flow fittings for ducts and
Compatibility of accessories

Size with single Heat Exchanger


FCZ 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000
Probes and accessories for control panels
KTLP P-PO • • • • • • • • • • * * * * * * • • •
PX-PX2-PX2C6 P-PO (1) • • • • • • • • • • • • • • • • • • •
PXAE P-PPC-PO • • • • • • • • • • • • • • • • • • •
PXAR P-PO • • • • • • • • • • • • • • • • • • •
TPF P-PO • • • • • • • • • • • • • • • • • • •
WMT05-06-10 P-PO • • • • • • • • • • • • • • • • • • •
FMT21 P-PO • • • • • • • • • • • • • • • • • • •
SWA P-PO • • • • • • • • • • • • • • • • • • •
SW3 P-PO • • • • • • • • • • • • • • • • • • •
SIT3 P-PO • • • • • • • • • • • • • • • • • • •
SIT5 P-PPC-PO • • • • • • • • • • • • • • • • • • •
VMF System
VMF-E0 P-PPC-PO • • • • • • • • • • • • • • • • • • •
VMF-E1 P-PPC-PO • • • • • • • • • • • • • • • • • • •
VMF-E4 P-PPC-PO • • • • • • • • • • • • • • • • • • •
VMF-SW P-PPC-PO • • • • • • • • • • • • • • • • • • •
VMF-SW1 P-PPC-PO • • • • • • • • • • • • • • • • • • •
Additional coil (heating only)
BV117 P-PO •
BV122 P-PO •
BV132 P-PO •
BV142 P-PO • •
BVZ800 P-PO • • •
BV162 P-PO • •
Electrical Heat Exchanger
RX17 P-PO •
RX22 P-PO •
RX32 P-PO •
RX42 P-PO • •
RXZ800 P-PO • • •
RX62 P-PO • •
Water valves
Valve Kit for 4 pipe systems with Main coil
VCZ1X4L-R P-PO • • • •
VCZ2X4L-R P-PO • • • • • • • • • • • •
VCF3X4L-R P-PO • • •
3 way valve kit
VCZ41/4124 P-PPC-PO (2) • • • •
VCZ42/4224 P-PPC-PO (2) • • • • • • • • • • • •
VCF43/4324 P-PPC-PO (2) • • •
2 way valve kit
VCZD1/124 P-PPC-PO (2) • • • •
VCZD2/224 P-PPC-PO (2) • • • • • • • • • • • •
VCFD3/324 P-PPC-PO (2) • • •
Installation accessories
AMP20 P-PPC-PO • • • • • • • • • •
AMPZ P-PPC-PO • • • • • • • • • • • • • • • • • • •
DSC4 P-PPC-PO (3) • • • • • • • • • • • • • • • • • • •
Auxiliary condensate drip tray
BC4 P (4) • • • • • • • • • • • • • • • •
BC5 P (5) • • • • • • • • • •
BC8 P-PPC-PO (5) • • • • • • • • • •
BC6 P (5) • • •
BC9 P-PPC-PO (5) • • •
Ventilcassaforma
CHF17 P-PPC • •
CHF22 P-PPC-PO • •
CHF32 P-PPC-PO • •
CHF42 P-PPC-PO • • • •
CHF62 P-PPC-PO • • • • • • • • •
Grille
GA17 P-PPC • •
GA22 P-PPC-PO • •
GA32 P-PPC-PO • •
GA42 P-PPC-PO • • • •
GA62 P-PPC-PO • • • • • • • • •

PO version only available for size from 2 to 9


For more details on the control panels and VMF system refer to the dedicated sheet.
* Contact Aermec
(1) PX2C6 panel PX2 in multiple 6 pz., Only for wall installation
(2) VCZ4124-VCZ4224-VCF4324-VCZD124-VCZD224-VCFD324 are 24V
(3) DSC4 It's not available with AMPZ
(4) For vertical installation. BC4 is not available whith valve VCZ-VCZD / VCF-VCFD
(5) For horizontal installation
Compatibility of accessories
Single coil models
FCZ 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000
GAF17 P-PPC • •
GAF22 P-PPC-PO • •
GAF32 P-PPC-PO • •
GAF42 P-PPC-PO • • • •
GAF62 P-PPC-PO • • • • • • • • •
GM17 P-PPC • •
GM22 P-PPC-PO • •
GM32 P-PPC-PO • •
GM42 P-PPC-PO • • • •
GM62 P-PPC-PO • • • • • • • • •
Accessories for installation
PA17 P-PPC • •
PA22 P-PPC-PO • •
PA32 P-PPC-PO • •
PA42 P-PPC-PO • • • •
PA62 P-PPC • • • • • • • • •
PA17F P-PPC • •
PA22F P-PPC-PO • •
PA32F P-PPC-PO • •
PA42F P-PPC-PO • • • •
PA62F P-PPC • • • • • • • • •
PM17 P-PPC • •
PM22 P-PPC-PO • •
PM32 P-PPC-PO • •
PM42 P-PPC-PO • • • •
PM62 P-PPC • • • • • • • • •
RD17 P-PPC • •
RD22 P-PPC-PO • •
RD32 P-PPC-PO • •
RD42 P-PPC-PO • • • •
RD62 P-PPC • • • • • • • • •
RDA17 P-PPC • •
RDA22 P-PPC-PO • •
RDA32 P-PPC-PO • •
RDA42 P-PPC-PO • • • •
RDA62 P-PPC • • • • • • • • •
RPA17 P-PPC • •
RPA22 P-PPC-PO • •
RPA32 P-PPC-PO • •
RPA42 P-PPC-PO • • • •
RPA62 P-PPC • • • • • • • • •

Plenum for duct installation


RDA000V PO • •
RDA100V PO • •
RDA200V PO • • • •
RDA300V PO • • • • • •
RPA000V PO (6) • •
RPA100V PO (6) • •
RPA200V PO (6) • • • •
RPA300V PO (6) • • • • • •
RDAC000V PO • •
RDAC100V PO • •
RDAC200V PO • • • •
RDAC300V PO • • • • • •
PA000V PO (6) • •
PA100V PO (6) • •
PA200V PO (6) • • • •
PA300V PO (6) • • • • • •
PM000V PO (6) • •
PM100V PO (6) • •
PM200V PO (6) • • • •
PM300V PO (6) • • • • • •
RPM000V PO (6) • •
RPM100V PO (6) • •
RPM200V PO (6) • • • •
RPM300V PO (6) • • • • • •
RDMC000V PO • •
RDMC100V PO • •
RDMC200V PO • • • •
RDMC300V PO • • • • • •

PO version only available for size from 2 to 9


(6) All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs (Ø=150mm ) on both sides, which can be removed, All the can have intake/discharge either
straight or downwards (straight or downwards with reference to horizontal installation).
Compatibility of accessories

Twin coil models


FCZ 101 102 201 202 301 302 401 402 501 502 601 602 701 702 801 802 901 1001
Probes and accessories for control panels
KTLP P-PO • • • • • • • • • • * * * * * * • •
PXAE P-PO • • • • • • • • • • • • • • • • • •
TPF P-PO • • • • • • • • • • • • • • • • • •
WMT06-10 P-PO • • • • • • • • • • • • • • • • • •
FMT21 P-PO • • • • • • • • • • • • • • • • • •
SWA P-PO • • • • • • • • • • • • • • • • • •
SW3 P-PO • • • • • • • • • • • • • • • • • •
SIT3 P-PO • • • • • • • • • • • • • • • • • •
SIT5 P-PO • • • • • • • • • • • • • • • • • •
VMF System
VMF-E0 P-PO • • • • • • • • • • • • • • • • • •
VMF-E1 P-PO • • • • • • • • • • • • • • • • • •
VMF-E4 P-PO • • • • • • • • • • • • • • • • • •
VMF-SW P-PO • • • • • • • • • • • • • • • • • •
VMF-SW1 P-PO • • • • • • • • • • • • • • • • • •
Water valve
3 way valve kit
VCZ41/4124 P-PO (2) • • • •
VCZ42/4224 P-PO (2) • • • • • • • • • • • •
VCF43/4324 P-PO (2) • •
2 way valve kit
VCZD1/124 P-PO (2) • • • •
VCZD2/224 P-PO (2) • • • • • • • • • • • •
VCFD3/324 P-PO (2) • •
3 way valve kit for heating coil only
VCF44/4424 P-PO (2) • • • • • • • • • • • • • • • •
VCF45/4524 P-PO (2) • •
2 way valve kit for heating coil only
VCFD4/424 P-PO (2) • • • • • • • • • • • • • • • • • •
Accessories for installation
AMP20 P-PO • • • • • • • • • •
AMPZ P-PO • • • • • • • • • • • • • • • • • •
DSC4 P-PO (3) • • • • • • • • • • • • • • • • • •
Auxiliary condensate drip tray
BC4 P (4) • • • • • • • • • • • • • • • •
BC5 P (5) • • • • • • • • • •
BC6 P (5) • •
BC8 P-PO (5) • • • • • • • • • •
BC9 P-PO (5) • •
Ventilcassaforma
CHF17 P • •
CHF22 P • •
CHF32 P • •
CHF42 P • • • •
CHF62 P • • • • • • • •
Condensate drainage device
DSC4 P-PO • • • • • • • • • • • • • • • • • •
Grille
GA17 P • •
GA22 P-PO • •
GA32 P-PO • •
GA42 P-PO • • • •
GA62 P-PO • • • • • • • •
GAF17 P • •
GAF22 P-PO • •
GAF32 P-PO • •
GAF42 P-PO • • • •
GAF62 P-PO • • • • • • • •
GMF17 P • •
GMF22 P-PO • •
GMF32 P-PO • •
GMF42 P-PO • • • •
GMF62 P-PO • • • • • • • •

PO version only available for size from 2 to 9


(2) VCZ4124-VCZ4224-VCF4324-VCZD124-VCZD224-VCFD324-VCZ4424-VCF4524-VCFD424 are 24V
(3)DSC4 It's not available with AMPZ
(4) For vertical installation
(5) For horizontal installation
Compatibility of accessories

Twin coil models


FCZ 101 102 201 202 301 302 401 402 501 502 601 602 701 702 801 802 901 1001
Accessories for installation
PA17 P • •
PA22 P-PO • •
PA32 P-PO • •
PA42 P-PO • • • •
PA62 P-PO • • • • • • • •
PA17F P • •
PA22F P-PO • •
PA32F P-PO • •
PA42F P-PO • • • •
PA62F P-PO • • • • • • • •
PM17 P • •
PM22 P-PO • •
PM32 P-PO • •
PM42 P-PO • • • •
PM62 P-PO • • • • • • • •
RD17 P • •
RD22 P-PO • •
RD32 P-PO • •
RD42 P-PO • • • •
RD62 P-PO • • • • • • • •
RDA17 P • •
RDA22 P-PO • •
RDA32 P-PO • •
RDA42 P-PO • • • •
RDA62 P-PO • • • • • • • •
RPA17 P • •
RPA22 P-PO • •
RPA32 P-PO • •
RPA42 P-PO • • • •
RPA62 P-PO • • • • • • • •

Plenum for duct installation


RDA000V PO • •
RDA100V PO • •
RDA200V PO • • • •
RDA300V PO • • • • •
RPA000V PO (6) • •
RPA100V PO (6) • •
RPA200V PO (6) • • • •
RPA300V PO (6) • • • • •
RDAC000V PO • •
RDAC100V PO • •
RDAC200V PO • • • •
RDAC300V PO • • • • •
PA000V PO (6) • •
PA100V PO (6) • •
PA200V PO (6) • • • •
PA300V PO (6) • • • • •
PM000V PO (6) • •
PM100V PO (6) • •
PM200V PO (6) • • • •
PM300V PO (6) • • • • •
RPM000V PO (6) • •
RPM100V PO (6) • •
RPM200V PO (6) • • • •
RPM300V PO (6) • • • • •
RDMC000V PO • •
RDMC100V PO • •
RDMC200V PO • • • •
RDMC300V PO • • • • •

PO version only available for size from 2 to 9


(6) All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs (Ø=150mm ) on both sides, which can be removed, All the can have intake/discharge either straight
or downwards (straight or downwards with reference to horizontal installation).
Technical data - with single coil
FCZ 100 150 200 250 300 350 400 450 500 550
Fan speed H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L
Heating Performance
2 pipe systems
Heating capacity (70°C) (1) kW 2,40 2,00 1,46 2,65 2,19 1,55 3,70 2,95 2,02 4,05 3,18 2,20 5,50 4,46 3,47 6,15 4,92 3,77 7,15 5,74 4,32 7,82 6,29 4,57 8,50 7,31 5,27 9,75 8,34 5,82
Water flow rate (1) l/h 206 172 125 228 188 133 318 253 173 348 273 189 473 383 298 529 423 324 615 493 371 672 532 393 731 629 453 838 717 500
Pressure drop (1) kPa 9 6 4 14 10 6 20 13 7 31 20 11 17 12 7 28 19 12 32 21 11 22 13 9 42 42 42 33 25 14
Heating capacity (45°C) (2) kW 1,19 1,00 0,72 1,32 1,09 0,77 1,84 1,47 1,00 2,01 1,58 1,09 2,74 2,22 1,72 3,06 2,45 1,87 3,56 2,85 2,15 3,89 3,13 2,27 4,23 3,64 2,62 4,85 4,15 2,90
Water flow rate (2) l/h 207 173 126 229 189 134 319 254 174 350 274 190 475 385 299 531 425 325 617 495 373 675 543 394 734 631 455 842 720 502
Pressure drop (2) kPa 9 6 4 14 10 6 20 13 7 31 20 11 17 12 7 28 19 12 32 21 11 22 14 9 43 43 43 33 25 14
Cooling Performance
Total cooling capacity (3) kW 1,00 0,84 0,65 1,27 1,06 0,80 1,60 1,29 0,89 1,94 1,56 1,06 2,65 2,18 1,68 3,03 2,46 1,89 3,60 2,93 2,21 4,04 3,21 2,41 4,25 3,69 2,68 4,80 4,13 2,91
Sensible cooling capacity (3) kW 0,83 0,69 0,51 0,97 0,80 0,57 1,33 1,05 0,71 1,52 1,20 0,80 2,04 1,65 1,26 2,18 1,76 1,33 2,67 2,14 1,59 2,91 2,30 1,69 3,18 2,73 1,94 3,49 2,98 2,07
Water flow rate (3) l/h 172 144 112 219 182 138 275 221 153 334 267 182 456 374 288 560 460 350 619 503 379 694 552 414 731 634 460 824 711 501
Pressure drop (3) kPa 8 6 3 15 11 6 18 12 6 35 25 13 18 13 8 35 25 15 34 26 19 32 24 18 49 42 25 46 34 18
Fans
Centrifugal Fans n° 1 1 2 2 2
Air flow rate m3/h 200 160 110 200 160 110 290 220 140 290 220 140 450 350 260 450 350 260 600 460 330 600 460 330 720 600 400 720 600 400
Sound level
Sound power level (4) dB(A) 45 38 31 45 38 31 50 43 31 50 43 31 48 41 34 48 41 34 51 44 39 51 44 39 56 51 42 56 51 42
Sound pressure level dB(A) 37 30 23 37 30 23 42 35 23 42 35 23 40 33 26 40 33 26 43 36 31 43 36 31 48 43 34 48 43 34
Hydraulic connections
Main coil
Standard Ø 1/2" / 1/2" / 3/4" / 3/4" / 3/4" /
Oversized Ø / 1/2" / 1/2" / 3/4" / 3/4" / 3/4"
Electrical data
Absorbed power W 30 25 20 30 25 20 35 25 13 35 25 13 44 33 25 44 33 25 57 43 30 57 43 30 76 52 38 76 52 38
Max. input current A / / / / / / / / / /
Connected for speeds V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1
Power supply V/ph/Hz 230V~50Hz

FCZ 600 650 700 750 800 850 900 950 1000
Fan speed H M L H M L H M L H M L H M L H M L H M L H M L H M L
Hating Performance
2 pipe systems
Heating capacity (70°C) (1) kW 10,00 8,10 5,70 11,50 9,15 6,21 11,00 9,80 8,10 12,50 11,30 9,10 12,00 10,80 9,80 14,00 12,35 11,30 15,14 13,35 10,77 17,10 14,42 11,20 17,02 15,24 12,56
Water flow rate (1) l/h 860 696 490 989 785 534 946 843 696 1075 972 782 1032 929 843 1204 1062 972 1328 1171 945 1500 1295 982 1493 1337 1101
Pressure drop (1) kPa 25 17 9 54 36 12 37 30 21 20 16 11 42 35 29 24 19 16 21 16 11 32 23 15 43 34 24
Heating capacity (45°C) (2) kW 4,98 4,03 2,84 5,72 4,55 3,09 5,47 4,88 4,03 6,22 5,62 4,53 5,97 5,37 4,88 6,97 6,14 5,62 7,53 6,64 5,36 8,51 7,17 5,57 8,47 7,58 6,25
Water flow rate (2) l/h 863 699 492 993 790 536 950 846 699 1079 975 786 1036 932 846 1209 1066 975 1307 1152 930 1476 1245 967 1469 1316 1084
Pressure drop (2) kPa 25 18 9 54 36 12 37 30 21 20 17 11 43 35 30 24 19 17 20 15 11 31 21 15 42 33 23
Cooling Performance
Total cooling capacity (3) kW 4,65 3,90 2,85 5,67 4,80 3,46 5,50 4,89 3,92 6,14 5,34 4,27 6,10 5,67 4,84 6,91 6,29 5,26 6,91 5,00 4,29 8,60 7,32 5,77 7,62 6,88 5,69
Sensible cooling capacity (3) kW 3,92 3,17 2,28 4,13 3,44 2,42 4,31 3,76 2,99 4,72 4,06 3,20 4,83 4,42 3,72 5,36 4,84 4,00 5,68 3,78 2,97 5,78 4,87 2,80 5,53 5,35 4,42
Water flow rate (3) l/h 800 671 490 975 825 595 946 841 675 1056 918 734 1049 974 833 1189 1082 904 1189 860 738 1479 1259 992 1311 1183 979
Pressure drop (3) kPa 26 19 11 49 36 20 35 28 19 18 14 9 41 36 27 23 19 14 22 12 9 30 22 15 37 31 22
Fans
Fans Centrifugal n° 3 3 3 3 3
Air flow rate m3/h 920 720 400 920 720 400 1140 930 700 1140 930 700 1300 1120 900 1300 1120 900 1140 930 700 1140 930 700 1300 1120 900
Sound level
Sound power level (4) dB(A) 57 51 42 57 51 42 62 57 51 61 57 51 66 61 56 66 61 56 61 57 51 61 57 51 66 61 56
Sound pressure level dB(A) 49 43 34 49 43 34 54 49 43 53 49 43 58 53 48 58 53 48 53 49 43 53 49 43 58 53 48
Hydraulic connections
Main coil
Standard Ø 3/4" / 3/4" / 3/4" / 3/4" / 3/4"
Oversized Ø / 3/4" / 3/4" / 3/4" / 3/4" /
Electrical data
Absorbed power W 82 61 40 82 61 40 106 80 59 106 80 59 131 100 80 131 100 80 106 80 59 106 80 59 131 100 80
Max. input current A / / / / / / / / /
Connected for speeds V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1
Power supply V/ph/Hz 230V~50Hz

(1) Room air temperature 20°C d.b.; Water (in/out) 70°C/60°C;


(2) Room air temperature 20°C d.b.; Water (in/out) 45°C/40°C (EUROVENT)
(3) Room air temperature 27°C d.b./19°C w.b.; Water (in/out) 7°C/12°C (EUROVENT)
(4) Sound power level: based on mesurement in compliance with Eurovent 8/2
Sound pressure level (A-weighted) measured indoors with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Technical data - with main + supplementary coil
FCZ 101 102 201 202 301 302 401 402
Fan speed H M L H M L H M L H M L H M L H M L H M L H M L
Heating Performance
4 pipe systems
Heating capacity (1) kW 1,31 1,14 0,84 2,20 1,86 1,38 1,80 1,52 1,14 3,05 2,49 1,76 2,87 2,45 2,02 4,84 4,01 3,18 3,50 2,97 2,38 5,92 4,86 3,75
Water flow rate (1) l/h 113 98 73 190 160 119 155 130 98 262 214 152 247 210 174 416 345 274 301 255 205 509 418 322
Pressure drop (1) kPa 5 4 2 4 3 2 12 9 6 9 6 4 36 27 19 27 19 13 10 8 5 9 5 4
Cooling Performance
Total cooling capacity (2) kW 1,00 0,84 0,65 1,00 0,84 0,65 1,60 1,29 0,89 1,60 1,29 0,89 2,65 2,18 1,68 2,65 2,18 1,68 3,60 2,93 2,21 3,60 2,93 2,21
Sensible cooling capacity (2) kW 0,83 0,69 0,51 0,83 0,69 0,51 1,33 1,05 0,71 1,33 1,05 0,71 2,04 1,65 1,26 2,04 1,65 1,26 2,67 2,14 1,59 2,67 2,14 1,59
Water flow rate (2) l/h 172 144 112 172 144 112 275 221 153 275 221 153 456 374 288 456 374 288 619 503 379 619 503 379
Pressure drop (2) kPa 8 6 3 8 6 3 18 12 6 18 12 6 18 13 8 18 13 8 34 26 19 34 26 19
Fans
Centrifugal fans n° 1 1 2 2
Air flow rate m3/h 200 160 110 200 160 110 290 220 140 290 220 140 450 350 260 450 350 260 600 460 330 600 460 330
Sound level
Sound power level (3) dB(A) 45 38 31 45 38 31 50 43 31 50 43 31 48 41 34 48 41 34 51 44 39 51 44 39
Sound pressure level dB(A) 37 30 23 37 30 23 42 35 23 42 35 23 40 33 26 40 33 26 43 36 31 43 36 31
Hydraulic connections
Main coil
Standard Ø 1/2" 1/2" 3/4" 3/4"
Additional coil
Standard Ø 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4"
Oversized Ø 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"
Electrical data
Absorbed power W 30 25 20 30 25 20 35 25 13 35 25 13 44 33 25 44 33 25 57 43 30 57 43 30
Max. input current A / / / / / / / /
Connected for speeds V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1
Power supply V/ph/Hz 230V~50Hz

FCZ 501 502 601 602 701 702 801 802 901 1001
Fan speed H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L
Heating Performance
4 pipe systems
Heating capacity (1) kW 4,18 3,74 2,90 7,21 6,33 4,66 4,88 4,11 2,83 8,50 6,98 5,14 5,54 4,80 4,10 9,85 8,37 6,98 5,97 5,36 4,71 10,75 9,51 8,18 6,41 6,30 5,30 6,81 6,23 5,43
Water flow rate (1) l/h 360 322 249 619 544 401 419 353 243 731 600 442 476 413 353 847 720 600 513 461 405 924 817 703 562 553 465 597 547 476
Pressure drop (1) kPa 12 10 6 9 8 4 19 14 9 15 11 6 25 19 18 20 15 13 28 23 15 23 18 14 15 14 11 19 16 13
Cooling Performance
Total cooling capacity (2) kW 4,25 3,69 2,68 4,25 3,69 2,68 4,65 3,90 2,85 4,65 3,90 2,85 5,50 4,89 3,92 5,50 4,89 3,92 6,10 5,67 4,84 6,10 5,67 4,84 6,91 5,00 4,29 7,62 6,88 5,69
Sensible cooling capacity (2) kW 3,18 2,73 1,94 3,18 2,73 1,94 3,92 3,17 2,28 3,92 3,17 2,28 4,31 3,76 2,99 4,31 3,76 2,99 4,83 4,42 3,72 4,83 4,42 3,72 5,68 3,78 2,97 5,53 5,35 4,42
Water flow rate (2) l/h 731 634 460 731 634 460 800 671 490 800 671 490 946 841 675 946 841 675 1049 974 833 1049 974 833 1189 860 738 1311 1183 979
Pressure drop (2) kPa 49 42 25 49 42 25 26 19 11 26 19 11 35 28 19 35 28 19 41 36 27 41 36 27 22 12 9 37 31 22
Fans
Centrifugal fans n° 2 3 3 3 3 3
Air flow rate m3/h 720 600 400 720 600 400 920 720 400 920 720 400 1140 930 700 1140 930 700 1300 1120 900 1300 1120 900 1140 930 700 1300 1120 900
Sound level
Sound power level (3) dB(A) 56 51 42 56 51 42 57 51 42 57 51 42 61 57 51 61 57 51 66 61 56 66 61 56 61 57 51 66 61 56
Sound pressure level dB(A) 48 43 34 48 43 34 49 43 34 49 43 34 53 49 43 53 49 43 58 53 48 58 53 48 53 49 43 58 53 48
Hydraulic connections
Main coil
Standard Ø 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Additional coil
Standard Ø 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Oversized Ø 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"
Electrical data
Absorbed power W 76 52 38 76 52 38 82 61 40 82 61 40 106 80 59 106 80 59 131 100 80 131 100 80 106 80 59 131 100 80
Max. input current A / / / / / / / / / /
Connected for speeds V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1 V3 V2 V1
Power supply V/ph/Hz 230V~50Hz

(1) Room air temperature 20°C d.b.; Water (in/out) 70°C/60°C;


(2) Room air temperature 27°C d.b./19°C w.b.; Water (in/out) 7°C/12°C (EUROVENT)
(3) Sound power level: based on mesurement in compliance with Eurovent 8/2
Sound pressure level (A-weighted) measured indoor with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Dimensions and Weights

C
FCZ_P / PO / PPC 100 101 102 150 200 201 202 250 300 301 302 350 400 401 402 450 500 501 502 550
D
Dimensions for all versions
Height A mm 453 453 453 453 453
B* mm 452 562 793 1013 1013
Width
D mm 412 522 753 973 973
Depth C mm 216 216 216 216 216 A
Weight kg 12 12 13 13 12 13 14 14 14 15 16 16 20 21 22 22 23 23 24 24
B

FCZ_P / PO / PPC 600 601 602 650 700 701 702 750 800 801 802 850 900 901 / 950 1000 1001 / /
Cod.: SFCZPUY.01 / 1604

Dimensions for all versions


Height A mm 453 453 453 558 558
B* mm 1147 1147 1147 1147 1147
Width
D mm 1122 1122 1122 1122 1122
Depth C mm 216 216 216 216 216
Weight kg 29 30 31 31 26 27 28 28 26 27 28 28 32 32
C
* maximum dimensions D
Aermec reserves the right to make all the modifications deemed Aermec S.p.A.
necessary for improving the product, including technical data. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia