Vijaya Diagnostic Centre

3-6-16 & 17, Street No. 19, Himayatnagar, Hyderabad - 500 029

Email : info@vijayadiagnostic.com
www.vijayadiagnostic.com

LABORATORY TEST REPORT


Regn Date : 01/09/2021 15:44 Sample Collection : 01/09/2021 15:41

Name : MR. KRISHNA SINGH Print Date : 02/09/2021 10:42

Regn No : 52121520 Age / Sex : 34 Years / Male


Ref By : SELF Regn Centre : kavuri hills-5
Sample Type : Swab Ref no. : S121411777461

COVID -19 TESTING - SARS -CoV-2 RNA


TEST NAME RESULT

SARS-CoV-2 (RdRp gene) : NEGATIVE


Method: Real Time RT-PCR

--------------------------
INTERPRETATION:
--------------------------
Result | Remarks
------------------------------------------------------------------------
Positive | RNA specific to SARS-CoV-2 Detected.
------------------------------------------------------------------------
Negative | RNA specific to SARS-CoV-2 NOT Detected.
------------------------------------------------------------------------

Limit of Detection:
-------------------
• Analytical lower unit of detection <150 viral genome equivalents/mL

Comments:
-------------------
• Covid 19 Qualitative RT PCR test is an in vitro qualitative PCR assay for the qualitative detection
of Novel Corona Virus 2019 in respiratory specimens
• Test is conducted on Nasopharyngeal swab/ Oropharyngeal swabs and other respiratory specimens collected
in viral transport media.
• Detection of confirmatory(RdRp) genes indicates presence of SARS-CoV-2 RNA in the specimen tested.
• Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for
patient management decisions. They must be correlated with clinical observations, patient history
and epidemiological information.
• Mutations or polymorphisms in the primer and probe binding sites, presence of PCR inhibition due to host
factors may also cause false negative results.
• Fresh sample for RT PCR can be considered after a gap of 2-4 days if there is a strong clinical
suspicion/contact of Covid 19 patient
• Repeat sampling and testing of lower respiratory specimen is strongly recommended in a severe or progressive disease.
• This test is a qualitative assay and does not quantify viral load. Various host factors, variability in
sample collection / site and techniques used by the laboratories can affect CT values. Therfore, CT values are not
an absolute indication of viral load and should be interpreted with caution.

Note:
• ICMR-Registration Number : VIJAY001
• COVID-19 test is conducted with a kit approved by ICMR/CE-IVD/US-FDA.
• Kindly consult Referring Physician/Authorized Government Hospital for appropriate follow up

MC-2657 DR.SHANKARI
CONSULTANT PATHOLOGIST

Released Date 02/09/2021 10:35 Page 1 of 1


Vijaya Diagnostic Centre
3-6-16 & 17, Street No. 19, Himayatnagar, Hyderabad - 500 029

Email : info@vijayadiagnostic.com
www.vijayadiagnostic.com

LABORATORY TEST REPORT


Regn Date : 01/09/2021 15:44 Sample Collection : 01/09/2021 15:41

Name : MR. KRISHNA SINGH Print Date : 02/09/2021 10:42

Regn No : 52121520 Age / Sex : 34 Years / Male


Ref By : SELF Regn Centre : kavuri hills-5
Sample Type : Whole Blood - EDTA Ref no. : S121411777461

MALARIA PARASITE V & F / ANTIGEN METHOD (RAPID)


TEST NAME RESULT BIOLOGICAL REFERENCE INTERVAL

Plasmodium falciparum : Negative NA


Method : Immunochromatography

Plasmodium vivax : Negative NA


Method : Immunochromatography

Comments / Interpretation :
----------------------------------
- Positive test result indicates the infestation of Malarial parasite.
- This is only screening test. The results are to be interpreted within epidemiological, clinical & therapeutic context.
- Even after successful antimalarial therapy the clearance of parasite may take longer and reaction of the test may remain positive.
In such cases, test should be repeated after 5 to 10 days of start of treatment.

MC-2657 DR.TAPOSHI DAS


CONSULTANT PATHOLOGIST

Released Date 02/09/2021 10:03 Page 1 of 4


Vijaya Diagnostic Centre
3-6-16 & 17, Street No. 19, Himayatnagar, Hyderabad - 500 029

Email : info@vijayadiagnostic.com
www.vijayadiagnostic.com

LABORATORY TEST REPORT


Regn Date : 01/09/2021 15:44 Sample Collection : 01/09/2021 15:41

Name : MR. KRISHNA SINGH Print Date : 02/09/2021 10:42

Regn No : 52121520 Age / Sex : 34 Years / Male


Ref By : SELF Regn Centre : kavuri hills-5
Sample Type : Whole Blood - EDTA Ref no. : S121411777461

COMPLETE BLOOD PICTURE (CBP)


TEST NAME RESULT BIOLOGICAL REFERENCE INTERVAL

Haemoglobin : 17.2 13.0 - 17.0 g/dL


Photometric measurement

Total RBC Count : 5.66 4.5 - 5.5 millions/cumm


Coulter Principle

Packed Cell Volume / Hematocrit : 51.70 40.0 - 50.0 Vol%


Calculated

MCV : 91.30 83.0 - 101.0 fl


Derived from RBC Histogram

MCH : 30.50 27 - 32 pg
Calculated

MCHC : 33.40 31.5 - 34.5 gm/dL


Calculated

RDW : 15.5 11.6 - 14.0 %


Derived from RBC Histogram

Total WBC Count : 7400 4000 - 10000 Cells/cumm


Coulter Principle
Differential count

Neutrophils : 55 40 - 80 %
VCSn Technology / Microscopy

Lymphocytes : 30 20 - 40 %
VCSn Technology / Microscopy

Eosinophils : 5 1-6 %
VCSn Technology / Microscopy

Monocytes : 9 2 - 10 %
VCSn Technology / Microscopy

Basophils : 1 0-2 %
VCSn Technology / Microscopy
Absolute Leucocyte Count

Absolute Neutrophil Count : 4070 2000 - 7000 Cells/cumm


Method : Calculation

Absolute Lymphocyte Count : 2220 1000 - 3000 Cells/cumm


Method : Calculation

Absolute Eosinophil Count : 370 20 - 500 Cells/cumm


Method : Calculation

Absolute Monocyte Count : 666 200 - 1000 Cells/cumm


Method : Calculation

Platelet Count : 169000 150000 - 410000 /cumm


Coulter Principle
Peripheral Smear

RBC : Normocytic Normochromic


Released Date 02/09/2021 08:55 Page 2 of 4
Vijaya Diagnostic Centre
3-6-16 & 17, Street No. 19, Himayatnagar, Hyderabad - 500 029

Email : info@vijayadiagnostic.com
www.vijayadiagnostic.com

LABORATORY TEST REPORT


Regn Date : 01/09/2021 15:44 Sample Collection : 01/09/2021 15:41

Name : MR. KRISHNA SINGH Print Date : 02/09/2021 10:42

Regn No : 52121520 Age / Sex : 34 Years / Male


Ref By : SELF Regn Centre : kavuri hills-5
Sample Type : Whole Blood - EDTA Ref no. : S121411777461

COMPLETE BLOOD PICTURE (CBP)


TEST NAME RESULT BIOLOGICAL REFERENCE INTERVAL
Microscopy : Leishman stain/Modified Giemsa Stain

WBC : Normal in morphology,maturity and distribution


Microscopy : Leishman stain/Modified Giemsa Stain

Platelets : Adequate

MC-2657 DR.TAPOSHI DAS


CONSULTANT PATHOLOGIST

Released Date 02/09/2021 08:55 Page 3 of 4


Vijaya Diagnostic Centre
3-6-16 & 17, Street No. 19, Himayatnagar, Hyderabad - 500 029

Email : info@vijayadiagnostic.com
www.vijayadiagnostic.com

LABORATORY TEST REPORT


Regn Date : 01/09/2021 15:44 Sample Collection : 01/09/2021 15:41

Name : MR. KRISHNA SINGH Print Date : 02/09/2021 10:42

Regn No : 52121520 Age / Sex : 34 Years / Male


Ref By : SELF Regn Centre : kavuri hills-5
Sample Type : Whole Blood - EDTA Ref no. : S121411777461

ERYTHROCYTE SEDIMENTATION RATE (ESR)


TEST NAME RESULT BIOLOGICAL REFERENCE INTERVAL

Erythrocyte Sedimentation Rate (ESR) : 3 0 - 15 mm/hr


Method : Automated (Modified Westergren)

Comments / Interpretation :
----------------------------------
- ESR is a nonspecific parameter, clinically useful in disorders associated with an increased production of acute phase proteins.
- Elevated in acute and chronic infections and malignancies.
- Extremely high ESR values are seen in multiple myeloma, leukemias, lymphomas, breast and lung carcinomas, rheumatoid
arthritis, Systemic Lupus Erythematosus and pulmonary infarction.

MC-2657 DR.TAPOSHI DAS


CONSULTANT PATHOLOGIST