Gravure Trouble-Shooting Guide: Chatter
Gravure Trouble-Shooting Guide: Chatter
Gravure Trouble-Shooting Guide: Chatter
Fountain too far away from cylinder Adjust fountain closer to cylinder
Ink flow valve not open enough Open valve wider / check for blockage
INK
Too little ink flow from fountain Ink filter clogged Change ink filter
FLOW
Ink pump not operating correctly Pressure gauge Replace ink pump
Fountain baffles are plugged or bent Clean / adjust baffles
Fountain too close to cylinder Adjust fountain away from cylinder
Too much ink flow from fountain
Ink flow valve open too wide Close valve slightly
Low temperature in dryer heat gun Raise dryer temperature
Low air flow in dryer magnehelic Increase dryer air flow
Ink not drying completely on web
Low steam pressure to dryer Notify maintenance
Press speed too high (small dryers only) Decrease press speed
High ink viscosity Solvent evaporation from ink viscosity test Slowly add more solvent to ink
PICKING Too much pressure on Impression roller measure nip flat area Decrease roller pressure
Too little pressure on impression roller measure nip flat area Increase roller pressure
Incorrect pressure on impression roller Impression roller is the wrong durameter durometer Tester Change roller durometer
Dirty impression roller Clean the impression roller
Defective / uneven impression roller Change the impression roller
Chill rollers too warm Water supply not cold enough / not flowing heat gun Notify maintenance
GRAVURE TROUBLE-SHOOTING GUIDE
DEFECT PROCESS PROBLEM PROBABLE CAUSE TEST POSSIBLE REMEDIES
Solvents blended incorrectly Have ink room adjust solvent blend
Incorrect solvent blend G.C. test (Add NPA for P-200 ink system)
High room temp causing evaporation Notify maintenance
Blade angle too sharp Flatten blade angle
Incorrect blade setting
Blade too thin Replace Blade
High ink viscosity Solvent evaporation from ink viscosity test Slowly add more solvent to ink
N Replace cylinder
Scum blower setting too high Lower air setting or turn off scum blower
N Too much air blowing on cylinder
Fan or draft blowing on cylinder puff tester Redirect air flow
E
Chill rollers too warm Water supply not cold enough / not flowing heat gun Notify maintenance
L
I Too much pressure on Impression roller measure nip flat area Decrease roller pressure
Incorrect pressure on impression roller Impression roller is the wrong durameter durometer Tester Change roller durometer
N
Defective / uneven impression roller Change impression roller
G High room temperature Notify maintenance
Install ink chillers
Ink temp too high
Impression nip point friction Decrease impression roller pressure
Too much agitation of the ink Check the ink pump
pressure gauge Change ink filter
Ink not thoroughly mixed Ink pump not operating correctly Unclog agitator elbow
Replace pump
GRAVURE TROUBLE-SHOOTING GUIDE
DEFECT PROCESS PROBLEM PROBABLE CAUSE TEST POSSIBLE REMEDIES
Add new ink to old ink
Low ink Viscosity Too much solvent in ink viscosity test
Replace ink
Ink pump not operating correctly pressure gauge Change ink filter
Unclog agitator elbow
Ink is not thoroughly mixed
M Replace pump
O Ink not properly mixed at formulation Return to ink room for mixing
T The ink has been "SHOCKED" Solvent poured too quickly into ink Replace ink
E Too little pressure on the impression roller measure nip flat area Increase pressure to the roller
Insufficient pressure at the nip point Impression roller is wrong durometer Change the roller to a harder durometer
Uneven wax coating weight on stock paper Change the paper
Incorrect cylinder engraving Engraving too deep / too shallow Replace the cylinder
I Too much ink flow from fountain Ink flow valve open too wide Close valve slightly
N
K Ink flowing over splash guard Blade angle too flat Adjust blade angle
.
S Ink splash guard leaking Splash guard set up incorrectly Reset splash guard inside ink pan
High ink viscosity Solvent evaporation from ink viscosity test Slowly add more solvent to ink
O Color mis-match at the ink room Wrong formulation used Replace ink
F Cylinder cells too deep / too shallow Cylinder is incorrectly engraved Replace cylinder
Wax coating weight on paper uneven Defective coating on stock paper Change paper
S Nicked blade
Filter ink
Blade polished incorrectly Change blade
Rough / high cylinder edges Have cylinder edges filed down
Lines are in the wax coating on the paper Defective coating on stock paper Change the paper
GRAVURE TROUBLE-SHOOTING GUIDE
DEFECT PROCESS PROBLEM PROBABLE CAUSE TEST POSSIBLE REMEDIES
Incorrect artwork used
Cylinder design incorrect Replace cylinder
G Insufficient pressure at the nip point Uneven pressure on impression roller Balance impression roller pressure
Defective or worn impression roller Replace impression roller
.
Cylinder mis-aligned in carriage Remount cylinder
P High ink viscosity viscosity test Slowly add more solvent to ink
R Clean / scrub out cylinder with solvent
I Too much air blowing on cylinder Turn off scum blowers or redirect fans
N Cylinder filled in with ink Clean / scrub out cylinder with solvent
Blade too far from nip point Move blade closer to nip point
T Ink pan too low Adjust ink pan
Ink temp too high thermometer Install ink chiller
GRAVURE TROUBLE-SHOOTING GUIDE
DEFECT PROCESS PROBLEM PROBABLE CAUSE TEST POSSIBLE REMEDIES
Low temperature in dryer heat gun Raise dryer temperature
Low air flow in dryer magnehelic Increase dryer air flow