1.0 ABSTRACT This paper reviews the applications of electric drives in the industries, taking into consideration the improving trend through the application of power electronics. Application of a variable frequency drive (Chassis drive) employed in driving Rolling Mills Machinery at Aluminum Rolling Mills (ARM), a subsidiary of Tower Aluminum Plc. Nigeria is briefly examined. The examination includes analysis of the power circuit and control circuit with waveforms, Design of power circuit, selection of devices employed in the drive system and problems associated with the use of the drive in the Industry.
2.0 INTRODUCTION Electric drive is an industrial system which performs the conversion of electrical energy to mechanical energy or vice versa for running various processes. Drives are employed for systems that require motion control e.g. transportation system, fans, robots, pumps, machine tools, etc. Prime movers are required in drive systems to provide the movement or motion and energy that is used to provide the motion can come from various sources: diesel engines, petrol engines, hydraulic motors, electric motors etc. Drives that use electric motors as the prime movers are known as electrical drives
There are several advantages of electrical drives: a. Flexible control characteristic This is particularly true when power electronic converters are employed where the dynamic and steady state characteristics of the motor can be controlled by controlling the applied voltage or current. b. Available in wide range of speed, torque and power c. High efficiency, lower noise, low maintenance requirements and cleaner operation d. Electric energy is easy to be transported.
2.1 Components of Electrical Drives: The main components of a modern electrical drive are the motors, power processor, control unit and electrical source. a) Motors: Motors obtain power from electrical sources. They convert energy from electrical to mechanical therefore can be regarded as energy converters. In braking mode, the flow of power is reversed. Depending upon the type of power converters used, it is also possible for the power to be fed back to the sources rather than dissipated as heat. There are several types of motors used in electric drives choice of type used depends on applications, cost, environmental factors and also the type of sources available. Broadly, they can be classified as either DC or AC motors: DC motors (wound or permanent magnet) AC motors: Induction motors squirrel cage, wound rotor Synchronous motors wound field, permanent magnet Brushless DC motor require power electronic converters Stepper motors require power electronic converters Synchronous reluctance motors or switched reluctance motor require power electronic converters
b) Power processor or power modulator: Since the electrical sources are normally uncontrollable, it is therefore necessary to be able to control the flow of power to the motor this is achieved using power processor or power modulator. With controllable sources, the motor can be reversed, brake or can be operated with variable speed. Conventional methods used, for example, variable impedance or relays, to shape the voltage or current that is supplied to the motor these methods however are inflexible and inefficient. Modern electric drives normally used power electronic converters to shape the desired voltage or current supplied to the motor. In other words, the characteristic the characteristic of the motors can be changed at will. Power electronic converters have several advantages over classical methods of power conversion such as: 1. More efficient since ideally no losses occur in power electronic converters 2. Flexible voltage and current can be shaped by simply controlling switching functions of the power converter 3. Compact smaller, compact and higher ratings solidstate power electronic devices are continuously being developed the prices are getting cheaper. Converters are used to convert and possibly regulate (i.e. using closed-loop control) the available sources to suit the load i.e. motors. These converters are efficient because the switches operate in either cut-off or saturation modes
c) Control Unit: The complexity of the control unit depends on the desired drive performance and the type of motors used. A controller can be as simple as few op-amps and/or a few digital ICs, or it canbe as complex as the combinations of several ASICs and digital signal processors (DSPs). The types of the main controllers can be: 1. analog - which is noisy, inflexible. However analog circuit ideally has infinite bandwidth. 2. digital immune to noise, configurable. The bandwidth is obviously smaller than the analog controllers depends on sampling frequency 3. DSP/microprocessor flexible, lower bandwidth compared to above. DSPs perform faster operation than microprocessors (multiplication in single cycle).With DSP/microp, complex estimations and observers can be easily implemented. d) Source Electrical sources or power supplies provide the energy to the electrical motors. For high efficiency operation, the power obtained from the electrical sources need to be regulated using power electronic converters. Power sources can be of AC or DC in nature and normally are uncontrollable, i.e. their magnitudes or frequencies are fixed or depend on the sources of energy such as solar or wind. AC source can be either three-phase or single-phase; 3-phase sources are normally for high power applications .There can be several factors that affect the selection of different configuration of electrical drive system such as: a) Torque and speed profile - determine the ratings of converters and the quadrant of operation required. b) Capital and running cost Drive systems will vary in terms of start-up cost and running cost, e.g. maintenance. c) Space and weight restrictions d) Environment and location
2.2 Comparison between DC and AC drives Motors: 1. DC require maintenance, heavy, expensive, speed limited by mechanical construction 2. AC less maintenance, light, cheaper, robust, high speed (esp. squirrelcage type)
Control unit: 1. DC drives: Simple control decoupling torque and flux by mechanical commutator the controller can be implemented using simple analog circuit even for high performance torque control cheaper. 2. AC drives, the types of controllers to be used depend on the required drive performance obviously, cost increases with performance. Scalar control drives technique does not require fast processor/DSP whereas in FOC or DTC drives, DSPs or fast processors are normally employed. Performance: 1. In DC motors, flux and torque components are always perpendicular to one another thanks to the mechanical commutator and brushes. The torque is controlled via the armature current while maintaining the field component constant. Fast torque and decouple control between flux and torque components can be achieved easily. 2. In AC machines, in particular the induction machines, magnetic coupling between phases and between stator and rotor windings makes the modeling and torque control difficult and complex. Control of the steady state operating conditions is accomplished by controlling the magnitude and the frequency of the applied voltage; which is known as the scalar control technique. This is satisfactory in some applications. The transient states or the dynamics of the machine can only be controlled by applying the vector control technique whereby the decoupling between the torque and flux components is achieved through frame transformations. Implementation of this control technique is complex thus requires fast processors such as Digital Signal Processors (DSPs).
3.0 HISTORICAL BACKGROUND 3.0.1 Electrical drives in industry Prior to the availability of electronics, clever electromechanical solutions involving combinations of dc and ac machines (e.g., Krmer and Scherbius systems) were developed early in the 20th century to control the speed of electric machines in industrial processes. The emergence of mature triggered-arc power switch technology (e.g., grid-controlled mercury-arc rectifiers, thyratrons, ignitrons) in the 1920s and 1930s provided a major boost to dc commutator machines as preferred prime movers for industrial drive application. This situation persisted for several decades until solid-state thyristors finally provided the crucial power switch breakthrough needed to build practical adjustable-frequency ac machine drives in the 1970s. Since that time, new generations of gate-controlled power switches have successively improved the performance and cost-effectiveness of ac drives in comparison to their dc drive counterparts. Although most of todays growth in the worldwide industrial drive market can be ascribed to ac drives, modern generations of dc drives continue to hold a significant share of the total industrial drive market.
3.0.2 Induction motors The AC squirrel-cage induction motors are the largest group of all electrical drives in the industry. It has been estimated that they are used in 70-80% of all industrial drive applications, especially in fixed-speed applications such as pump or fan drives. The benefits of induction motor are undisputable: simple construction, low cost compared to other motors, simple maintenance, high efficiency and satisfactory characteristics at the high speeds. With appropriate power electronics converters induction motors are used in wide power range from kW to MW levels. A common structure of induction motor is represented in Fig.1.4. Stator rotation field induces an electromotive force in the short-circuited rotor winding. Due to the induced voltage and short-circuited winding, current occurs in the rotor and electromagnetic torque is produced. Induction motor was invented in the end of 19th century. Its theory is well-known and power electronic converter technology provides appropriate variable-voltage/current, variable-frequency supply for efficient and stable variable-speed control. Thus, it is possible to obtain a dynamic performance in all respects better than which could be obtained with a phase-controlled DC drive combination. The significant characteristic of the induction motor is a slip caused by the rotor lagging the rotating stator magnetic field. Rotor copper losses are directly proportional to the slip. For example, the rotor copper losses in 4 kW motor are approximately 4.7% of the nominal power if the efficiency of 85% is supposed. The slip has also impact when a high dynamic performance is needed, since it derates the transient response of the motor. The main disadvantage of the induction motor for the servo control systems is the nonlinear speed versus torque and speed versus control voltage characteristics. Therefore such motors are inconvenient for the implementation of the belt-drives. Servo drives are applied for example in such areas of industry as: Paper industry Machine tools and metal working machinery Packaging machinery Woodworking In spite of the wide spread occurrence of electrical motors, the precision requirements for servo drives constantly increase.
3.0.3 Common motor types in motion control With invention of the motor the important question arisen is: how it can be controlled? The first speed-controlled drive was introduced by Harry Ward Leonard and it required three machines for scheme implementation. After the invention of transistor and rapid development of electronics, new possibilities for accurate control of DC motor, such as PWM technology, appeared. Brushless DC motors with permanent magnets were introduced in early 1960s, but their power was limited due to not enough powerful PM materials. Brushless DC motors for higher power application became available only after
the invention of PM materials with high energy density in the beginning of 1980s. Later on, when the field-oriented control was introduced, it was possible to apply AC motors for speed-controlled applications. First speed-controlled AC drives were induction motors but in early 1990s the vector control was also developed for PMSMs. Also, with rapid development of computer science became accessible control of stepper motors directly from microcontrollers. All these motor types are available for wide range of motion control applications.
3.1 CURRENT STATE OF THE DRIVE This past decade has witnessed major advances in power electronics technology for both industrial and traction drives. These advances have made it possible to significantly improve the electrical performance of these systems while simultaneously reducing their size and weight and, perhaps most importantly, reducing their cost. Improvements in all of these key metrics are expected to continue during coming years, with a few trends meriting special attention:
1) Modularization and Automated Manufacturing: Improved packaging of the power electronics components and subsystems is expected to be one of the most active development areas because of the significant cost reductions that are achievable by modularizing the power electronics and automating its manufacturing. Major progress toward these objectives can already be observed in many of the new industrial drive products with ratings of 10 kW or less. Wider acceptance of power electronics in automotive applications during coming years both for traction and accessory applicationswill likely provide a substantial boost for this trend by focusing the energies of the automotive industry on achieving these manufacturing economies. 2) Increasing Silicon Content: As the cost of power switches and their driver circuitry continues to diminish, trends toward increasing the proportion of active silicon- based power electronics in future drive products at the expense of passive components (i.e., capacitors, inductors, transformers) is certain to continue. Particularly in industrial drives, international trends toward tighter regulation of the input power quality of new products is expected to motivate the wider introduction of active rectifier stages using additional power switches with less dependence on special transformers and passive L-C filters. Direct ac/ac power converter topologies such as the matrix converter are expected to appear in some new applications, although their ability to broadly displace the dominant rectifier-inverter topology is very uncertain. Serious efforts are under way to use new high-voltage power switches in innovative configurations to eliminate the need for heavy and expensive transformers in future heavy-rail traction drives operating directly from 25-kV ac catenary supplies.
3) Power Converter/Machine Integration: The third notable technology trend, and perhaps the most controversial, is wider adoption of integrated packaging of the power electronics and the electrical machine in the same mechanical
package. Several industrial drive manufacturers have introduced product offerings ( 10 kW) based on this approach during recent years with limited initial market appeal, but anecdotal evidence indicates that acceptance among skeptical customers is gradually improving. Automotive manufacturers are exploring this approach as a long-term approach for modularizing the EV and HEV electric propulsion units while simultaneously reducing EMI emissions by eliminating long interconnecting cables between the inverter and machine. Significant technical hurdles associated with the ability of the power electronics to survive the heat and vibration of the harsh machine environments are, gradually being overcome, making the electronic motor concept increasingly attractive for many drive applications from both a technical and economic standpoint. 3.2 APPLICATION OF POWER ELECTRONICS IN DRIVES
The power electronic converters are used to obtain an adjustable DC voltage applied to the armature of a DC motor. There are basically two types of converters normally employed in DC drives: (i) controlled rectifier (ii) switch mode converter. (i) Controlled rectifier: Controlled rectifier can be operated from a single phase or three phase input. Output voltage contain low frequency ripple which may require a large inductor inserted in armature circuit, in order to reduce the armature current ripple. A large armature current ripple is undesirable since it may be reflected in speed response if the inertia of the motorload is not large enough. Controlled rectifier has a low bandwidth. The average output voltage response to a control signal, which is the delay angle, is relatively slow. Therefore cont rolled rectifier is not suitable for drives requiring a fast response. Eg. servo applications. In terms of quadrant of operations, a single phase or a three phase rectifier is only capable of operating in first and fourth quadrants which is no suitable for drives requiring forward breaking mode. To be able to operate in all four quadrants, configurations using back to back rectifiers or contactors shown below must be employed.
The thyristor d.c. drive remains an important speed-controlled industrial drive, especially where the higher maintenance cost associated with the d.c. motor brushes (c.f. induction motor) is tolerable. The controlled (thyristor) rectifier provides a low-impedance adjustable 'd.c.' voltage for the motor armature, thereby providing speed control.
3.2.1THYRISTOR D.C. DRIVES GENERAL For motors up to a few kilowatts the armature converter can be supplied from either single-phase or threephase mains, but for larger motors three-phase is always used. A separate thyristor or diode rectifier is used to supply the field of the motor: the power is much less than the armature power, so the supply is often single-phase, as shown in Figure 3(a). The arrangement shown in Figure 3(a) is typical of the majority of d.c. drives and provides for closed-loop speed control.
The main power circuit consists of a six-thyristor bridge circuit which rectifies the incoming a.c. supply to produce a d.c. supply to the motor armature. The assembly of thyristors, mounted on a heatsink, is usually referred to as the 'stack'. By altering the firing angle of the thyristors the mean value of the rectified voltage can be varied, thereby allowing the motor speed to be controlled. The controlled rectifier produces a crude form of d.c. with a pronounced ripple in the output voltage. This ripple component gives rise to pulsating currents and fluxes in the motor, and in order to avoid excessive eddy-current losses and commutation problems, the poles and frame should be of laminated construction. It is accepted practice for motors supplied for use with thyristor drives to have laminated construction, but older motors often have solid poles and/or frames, and these will not always work satisfactorily with a rectifier supply. It is also the norm for drive motors to be supplied with an attached 'blower' motor as standard. This provides continuous through ventilation and allows the motor to operate continuously at full torque even down to the lowest speeds without overheating. Low power control circuits are used to monitor the principal variables of interest (usually motor current and speed), and to generate appropriate firing pulses so that the motor maintains constant speed despite variations in the load. The 'speed reference' (Figure 1) is typically an analogue voltage varying from 0 to 10 V, and obtained from a manual speed-setting potentiometer or from elsewhere in the plant. The combination of power, control, and protective circuits constitutes the converter. Standard modular converters are available as off-the-shelf items in sizes from 0.5 kW up to several hundred kW, while larger drives will be tailored to individual requirements. Individual converters may be mounted in enclosures with isolators, fuses etc., or groups of converters may be mounted together to form a multi-motor drive.
4.0 APPLICATION OF DRIVES IN ALUMINIUM ROLLING MILLS(ARM). Set up in 1983, Aluminium Rolling Mils was a major step in backward integration for Tower Aluminium. Aluminium Rolling Mills ( ARM) is today one of the largest Rolling Mills in West Africa, with facilities for converting its basic raw material, aluminium ingots, into high quality coils & discs. The present installed capacity is 12,000 tons / annum.
Thickness 0.43 to 1.2 mm Used in roofing sheets. Thickness 1.2 mm upto 2 mm Used for cash boxes, port cabins, pick up van bodies, metal furniture.
Stucco Coils
Circles ( Discs )
Special coils
4.1 Roll Milling Machine Steel rolling mill machinery is used for making or shaping the metal. This machinery is very helpful in making or giving shape to the metals or steel. This steel rolling mill machinery varies on the basis of process. This machinery is mostly used in steel and metal factories. This machinery is proving its worth in mechanical industry. The unit which uses this steel rolling mill machinery is known as steel rolling mill plants. Steel is rolled in steel rolling mill plants. Following type of items are rolled in steel rolling mill machinery plants: Simple rounds, Steel rods, Wire rod in coils, Plates, Hot strips, H-beams, I-beams. Steel rolling mill machinery is categorized in two ways that is hot rolling mill machinery and cold rolling mill machinery. Hot rolling mill machinery- if the temperature of the metal is marked above its recrystallization temperature then the metal is rolled into hot rolling mill machinery.
Cold rolling mil machinery- if the temperature of the metal is marked below the recrystallisation temperature then the metal is rolled into cold rolling mill machinery. These procedures are carried out to harden the metal according to the requirements of different companies. The Chassis drive is one of the drives used in controlling the speed of the gears of the steel rolling mill machines. This drive will be chosen for detailing in this paper.
5.0
5.1 WAVEFORMS
Figure 5: (a) Stator current waveform (b) Stator voltage and current The power waveform of the motor is as shown above using a computer based monitor.
6.0 DESIGN OF THE POWER CIRCUITS The architecture for a typical panel-mounted chassis drive in the 50-kW power range is illustrated in Fig. 4. The core of the power circuitry for this drive consists of an input three-phase diode rectifier, a precharge circuit, dc link capacitor bank, and IGBT inverter stage. Other power components shown in this figure including the input line ac reactor, input electromagnetic interference (EMI) filter, dc link reactor, dynamic brake, and output filter are all optional depending on the application requirements.
1) Inverter Stage: Modern IGBTs have matured to a high state of electrical ruggedness that makes it possible to design the inverter stages with a minimum of additional snubber circuitry to limit either the rate of current change ( di/dt) or the rate of voltage change (dv/dt ) at the IGBT terminals. In fact, many new IGBT inverters are designed without any snubbers at all. This approach has the advantage of saving cost, space, and losses in the inverterall positive effects. However, the resulting switching rates at the IGBT output terminals in snubberless inverter designs can sometimes exceed 1000 A s and 10 000 V s, which is undesired and, in some cases, harmful consequences. For example, it has been confirmed that the high switching rates can interact with the inverter output cables and the machine windings to cause large transient voltages to appear across the outermost turns of the stator windings. Field experience has demonstrated that this situation sometimes leads to catastrophic failure of the stator winding insulation. Such conditions are most likely to occur in installations with unusually long cables between the drive inverter and machine. Some machine manufacturers have responded by strengthening the stator winding insulation, at least for the outermost turns. It was also found that the high switching rates can induce unbalanced charge build-ups on the machine rotor by means of parasitic capacitances coupling the machine stator, the rotor, inverter switches, and ground.
This accumulated rotor charge eventually discharges through the bearings if no other galvanic current path is provided. Over time, these discharges can cause serious pitting of the bearing balls and races that eventually leads to bearing failures under some circumstances that have been experienced in field installations. The introduction of insulated bearings or grounded rotor shaft brushes is among the solutions adopted by machine manufacturers to prevent these bearing failures. A third problem caused by the high and switching rates is elevated levels of conducted EMI in the drive input lines and ground that can easily exceed acceptable levels. Common-mode EMI can be significantly reduced by adding common-mode inductors in both the input and output lines, together with small capacitors between each dc link bus and earth ground to prevent these high-frequency currents from reaching the utility grid or machine. Modifications of the PWM switching algorithm can also be introduced to minimize the generation of common-mode EMI. Differential-mode EMI can be reduced by adding passive or active filters on the inverter output lines. Another effective, albeit somewhat ironic solution to these EMI problems is to use the IGBT gate drives to artificially slow their switching speeds, trading reduced EMI for elevated switching losses.
2) Input Rectifier Stage: By showing a diode rectifier stage in Fig. 4, the illustrated architecture is typical of the large majority of todays industrial drives ( 90%) that do not permit braking power to be returned to the utility lines. Although the diode rectifier has the advantage of low cost, it also imposes several constraints and disadvantages on the drive system that are attracting more attention every year. Perhaps most importantly, the basic diode rectifier draws current from each input line that is significantly distorted from its desired sinusoidal shape [Fig. 6(a)]. One of the purposes of including either a dc link reactor or three-phase input line reactors in the drive power circuitry is to reduce the amplitude of the input current harmonics in addition to limiting the peak dc link capacitor current and reducing the conducted EMI. However, Fig. 6(b) shows that, even when the ac line reactors are introduced with typical ratings (3% of the drive base impedance, in this case), the input line current harmonics are still very substantial, containing a fifth harmonic component greater than 40% of the fundamental component. Another constraint imposed by diode rectifiers is the need for pre-charging of the dc link capacitors to avoid dangerous surge current when the drive is initially connected to the ac line. A variety of pre-charge circuits are used depending on the drive power rating, including the parallel combination of resistor and bypass contactor illustrated in Fig. 4. For industrial drives with ratings greater than 30 kW, the diodes in the input rectifier stage are often partially or completely replaced by phase-controlled thyristors. Although more expensive than the diodes, the thyristors serve multiple purposes by providing the pre-charge function and serving as a fast electronic circuit breaker to remove power from the dc link in case of ground-fault or inverter failures.
Many industrial drive applications that demand only limited and infrequent machine braking capability (e.g., conveyors) can be satisfied by means of a dynamic brake assembly that dissipates the excess electrical
energy appearing on the dc link in external resistors (see Fig. 4). However, applications that involve frequent and extended periods of
braking (e.g., cranes) can justify the introduction of a regenerative input converter bridge as shown in Fig. 4 to provide the drive with bidirectional power conversion capabilities. The topology of the input converter bridge is identical to that of the inverter using six controlled switches (i.e., IGBTs) and six diodes, as shown previously in Fig. 3. Three-phase input line reactors are essential with the active input bridge configuration to provide the necessary input impedance characteristics to the bridge terminals. The addition of the regenerative active input bridge clearly represents an expensive solution that can only be justified today in applications that truly need bidirectional power flow. However, appropriate PWM control of the active input bridge results in significant system advantages by eliminating all of the undesirable low-order current harmonics that are associated with either diode or thyristor bridges, as well as providing independent control of the input power factor. Fig. 7 shows typical input line and dc link voltage/current waveforms for a regenerative drive system, illustrating the major improvement in line current harmonics compared to the diode rectifier waveform shown earlier in Fig. 6. This figure also illustrates the fast response that regenerative input stages can provide using vector control principles handling a step change in drive operation from full-load motoring to full-load braking with minimal perturbations of the dc link voltage.
3) Bus Capacitors: Electrolytic capacitors are the preferred choice for the dc link capacitors in almost all industrial drives. Minimum dc link capacitance requirements are usually determined by the rms currentcarrying capacity of the electrolytic capacitors and the need for sufficient dc link energy storage to allow the drive to ride through transient utility voltage sags. Typical electrolytic capacitor bank values for generalpurpose drives fall between 25 and 50 F per amp of inverter rms output current. Since the voltage ratings of electrolytic capacitors are usually limited to 500 Vdc or less, series and parallel combinations are required in many drive applications to support dc link voltages that exceed these ratings. Newer film capacitors are available with higher rms current ratings per F of capacitance and better reliability characteristics than their electrolytic counterparts. However, film capacitors are seldom used in place of electrolytics today because they are more expensive and smaller bus capacitance provides less drive ridethrough protection during utility voltage sag events.
7.0
Fig. 6. Three-phase diode rectifier characteristics. (a) Input voltage and current waveforms. (b) Input current frequency spectrum.
Figure 7: Block diagram of IGBT controlled drive of a 6Hi Cold Rolling Mill motors
8.0
The input voltage directly sets the oscillator and hence the inverter frequency. The input setting also determines the link voltage, so maintaining the voltage/frequency relationship. In order to march the motor speed with the increasing frequency, the frequency must start from zero and rise at a rate such that the torque can accelerate the rotor to this rate. The ramp unit delays the rise of voltage resulting from any step input, and allows the inverter frequency to rise slowly, so maintaining stability during the accelerating period. The accuracy of the drive depends on the oscillator frequency.The DC link voltage adjustment controls the motor voltage magnitude and frequency within the inverter can be controlled.
The use of insulated gate bipolar transistors enables switching within the inverter to be faster and more efficient than thyristor circuit.
Figure 8 : Diode-IGBT current switching characteristics for one inverter-leg, according to Martin (1996). T+ refers to the upper and T to the lower transistor and+ is the freewheeling diode of the upper transistor.
9.0
The Chassis drive is used for controlling the speed, torque, voltage and current of the 6Hi Cold Rolling Mill motors. The aim is to reduce the thickness of hot rolled coil. Also, the drive is used for controlling the uncoiler motor, the edge trimmer, motor, and the recoiler motor as shown below:
10.0
The devices used are: (a) Insulated Gate Bipolar Transistor based inverter (b) Converter transformer (c) Thyristor supply unit for conversion (d) Motor (e) Air Circuit Breakers (ACB) (f) Moulded Case Circuit Breakers (MCCB) (g) Contactor (h) Relays (i) Indicator Lamp (j) Fuse (k) Encoder
11.0 PROBLEMS ASSOCIATED WITH THE USE OF THE DRIVE IN THE INDUSTRY 1. The drive discussed above is a variable frequency drive, hence the introduction of harmonic Pollution by non-linear elements in the make up of the drive is a challenge the industries Face with the application of the drive. 2. The resulting switching rates at the IGBT output terminals in snubberless inverter designs Employed in the drive can sometimes exceed 1000 A s and 10 000 V s, which is undesired and, in some cases, harmful. 3. This high switching rates can induce unbalanced charge build-ups on the machine rotor by means of parasitic capacitances coupling the machine stator, the rotor, inverter switches, and ground. This accumulated rotor charge eventually discharges through the bearings if no other galvanic current path is provided. Over time, these discharges can cause serious pitting of the bearing balls and races that eventually leads to bearing failures under so circumstances that have been experienced in field installa tions 4. Erratic power supply from the supply authority can cause huge damage during manufacturing
12.0 RECOMMENDATION The stator winding insulation should be strengthened, at least the outer most insulation. Necessary filter circuit should be introduced to reduced the effect of harmonics. Insulated bearings or grounded rotors should be Incorporated to reduce the effect of bearing failure in the applications of the drive. Technology transfer method should be adopted to develop our local industry. Research and development of drives that suit the local industry should be vigorously pursued.
13.0
CONCLUSIONS
Drives are important in every manufacturing industry as they provide means of adjusting torque, speed, voltage, current as regards to a given motor leading to reduction in the electrical energy demand of a system and industry at large. Local manufacture of drives will go a long way to developing our local technology as well as human resources.
REFERENCES [1] Ashfaq Amhed, Power Electronics for Technology, Prentice Hall, New Jersey, 1999. [2] J.A. Odunsi, Electrical Installation, Design and Drafting, Yabatech Press, Lagos, 2000.
[3] Cyril W. Lander, Power Electronics, McGRAW-HILL Book Company, England, 1993. [4] Katsuhiko Ogata, Modern Control Engineering, Prentice Hall, India, 2009. [5] O.D. Osunde, Bridgeless Asymmetrical Single Phase AC-DC Boost Converter for Power Factor Correction, Proceedings of the 3rd International Conference on Power Systems and Telecommunications, UNILAG, July 22nd-24th, 2009, pp52-55. [6] J.M.D. Murphy and F.G. Turnbull, Power Electronic Control of AC Motors, Pergamon Press, New York, 1988. [7] www.ABB.com(downloaded 25th April, 2010). [8] T. M. Jahns and E. L. Owen, AC adjustable-speed drives at the new millennium: Howdid we get here?, in Proc. 2000 IEEE Appl. Power Elec. Conf., New Orleans, LA, Feb. 2000, pp. 1826. [9] D. P. J. Link, Minimizing electric gearing currents in SSD systems,IEEE Ind. Appl. Mag., pp. 5566, July/Aug. 1999. [10] S. Bhattacharya, L. Resta, D. M. Divan, and D.W. Novotny, Experimental comparison of motor bearing currents with PWM hard- and soft-switched voltage-source inverters, IEEE Trans. Power Electron., vol. 14, pp. 552562, May 1999. [11] M. Cacciato, A. Consoli, G. Scarcella, and A. Testa, Reduction ofcommon-mode currents in PWMinverter motor drives, IEEE Trans. Ind. Applicat., vol. 35, pp. 469477, Mar./Apr. 1999. [12] G. Oriti, A. Julian, and T. Lipo, Elimination of common mode voltage in three phase sinusoidal power converters, in Proc. IEEE Power Elec. Spec. Conf., Baveno, Italy, June 1996, pp. 19681972.