Test Solutions Et Kits
Test Solutions Et Kits
Test Solutions Et Kits
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding
Kittiwake
Make fast on-site maintenance decisions fast with Parker Kittiwake’s complete range
of oil test kits. An economical range, providing reliable oil condition results in minutes.
Parker Kittiwake’s oil test kit range provides a complete set of economically priced equipment,
with a level of accuracy suited to routine analysis. Oil test kits provide you with a condition
monitoring tool enabling you to make informed operational and maintenance decisions about
your critical plant and equipment. The ability to test on-site at the point of use enables engineers
and facilities managers to conduct oil analysis quickly and easily. Detecting out-of-spec fuels
and lubricants can identify potential problems, before become critical. Choose from a range of
equipment and parameters to use either individually, or combined as a single test kit.
Protect your assets, improve productivity & increase uptime with regular on-site oil analysis
FG-K1-102-KW DIGI Water / Viscosity Kit DIGI Water in Oil Cell 0.02-1%, 200-10,000 ppm, 0-10%, 0-20%
version ECON Viscostick go/no go
FG-K1-103-KW DIGI Basic Kit DIGI Water in Oil Cell 0.02-1%, 200-10,000 ppm, 0-10%, 0-20%
version ECON Salt Test go/no go
ECON Insolubles Test qualitative
ECON Viscostick go/no go
FG-K1-107-KW DIGI Industrial Kit DIGI Combined Water in Oil/BN cell 0.02-1%, 200-10,000 ppm, 0-10%, 0-20% / 5-100 BN
version ECON Insolubles Test qualitative
ECON Viscostick go/no go
FG-K1-108-KW DIGI Field Kit DIGI Combined Water in Oil/BN cell 0.02-1%, 200-10,000 ppm, 0-10%, 0-20% / 5-100 BN
version ECON Insolubles Test qualitative
ECON Viscostick go/no go
ECON AN Test AN: 0-6
FG-K1-110-KW DIGI Combined Kit DIGI Combined Water in Oil/BN cell 0.02-1%, 200-10,000 ppm, 0-10%, 0-20% / 5-100 BN
version ECON Salt Test go/no go
ECON Insolubles Test qualitative
ECON Viscostick go/no go
FG-K14971-KW DIGI Clean Oil Kit DIGI Water in Oil Cell 0.02-1%, 200-10,000 ppm, 0-10%, 0-20%
DIGI Viscotube 20-600 cSt @ 40°C
ECON AN Test AN: 0-6
FG-K16897-KW DIGI Biodiesel Test Kit DIGI Low Range Water in Oil Cell 0.02-1%, 100-3000 ppm, 0-10%
Low Range Falling Ball Viscometer 1-10 cSt @ 40°C
Density Hydrometer 850-950 kg/m3
Free Fatty Acid Test / AN Test Acid Content / 0-6 AN
Visual Test (Cleanliness) qualitative
NB: Electronic laboratory grade analysis equipment is also available for Water in Oil, Base Number (BN), Acid Number (AN) and
Insolubles. See the Oil Analysis Solutions Brochure for further details.
Parker Kittiwake Test Cells
At the heart of Parker Kittiwake’s on-site oil test solution Latest transducer
technology for
range, is the DIGI Test Cell, providing simple, accurate
improved accuracy
results for Water in Oil and Base Number (BN). Electronic display and ease of cleaning
gives step by step test
With an easy to read digital display providing instructions and instructions
results, a five year (5000 tests) battery life and built in memory Nonslip twist
for recording previous test results, the Parker Kittiwake DIGI grips
Cell has become a favoured test method worldwide for on- Simple to use key pad for
ease of use
site and on-board testing. Test cells are available individually
for either Water in Oil or Base Number. Alternatively, a DIGI
Combined Test Cell is available that performs both test
Lightweight glass
parameters in a single cell. reinforced plastic body
Both types of test cells have recently been upgraded to offer
increased functionality and usability. All reagents and test
methods remain the same.
Water in Oil
Maintain and protect your equipment, whilst
Ordering Information
eliminating damage caused by water in your oil.
The DIGI Water in Oil Test Kit provides state of the FG-K1-101-KW: DIGI Water in Oil Kit
FG-K17032-KW: DIGI Water in Oil Kit
art, digital analysis and gives fast, accurate results (Low Range)
for easy monitoring of trends. The DIGI Water in
Oil Test Kit contains the test cell together with all Range: 0.02-1%, 200-1000 ppm, 0-10%, 0-20%
Range: (LR): 0.02-1%, 100-3000 ppm, 0-10%
necessary reagents and equipment for an easy to Test Time: 3 minutes
use, economical test. Memory: Previous test, plus five oils
Battery Life: Five years (5000 tests)
• Prevent corrosion, cavitation or failure of your machinery by detecting water in oil, before any damage occurs
• Minimise instability of additive packages and damaging microbe growth by monitoring your oil
• Fully portable for use on-board or in the field, test kits are extremely robust, durable and easy to use
• Avoid fouling within the engine and corrosion of engine components by monitoring the Base Number (BN) of your lubricating
oils
• Simple, economical monitoring of lubricants
Viscosity
Viscosity is widely regarded as an oils most
DIGI Viscotube Ordering Information
important characteristic. It is the viscosity
that shows the oil’s resistance to flow and the FG-K14828-KW: DIGI Viscotube
strength of the oil film between surfaces.
Range: 20-600 cSt @ 40°C using three sizes of ball
The Parker Kittiwake DIGI Viscometer (or Application: Lubricating oils, hydraulic oil, warm
Viscotube) uses the falling ball technique fuel oil
No. of Tests: Unlimited
to measure the viscosity of an oil. The DIGI Test Time: 1-10 minutes
Viscotube is provided with viscosity calculation
software and a Digital Thermometer for accurate FG-K3-020-KW: ECON Viscostick
results.
Range: go/no go
The ECON Viscostick gives a simple go/no go Application: Lubricating oils, viscous hydraulics
No. of Tests: Unlimited
result. Typically it will detect 5-10% distillate fuel
Test Time: 1 minute
dilution of an SAE 30 to 40 engine oil as well as
increases in viscosity due to oil contamination.
• Make informed maintenance decisions and prevent costly machinery downtime ECON Viscostick
• Test kit is supplied with up to fifty tests, enabling you to monitor AN level trends
• Simple to use drop test - the result is shown by a colour change, providing you with easy to interpret results, suitable for
use by non-technical personnel
Parker Kittiwake test kits for individual parameters contain reagents, consumables and
full instructions for multiple tests.