DISCONNECTORS

400 kV, 2000 Amps Center Break Isolator Installed At RRVPNL, Heerapura, Since 2000.
Motor Operating Mechanism 400 kV, DBRB Isolator Contacts

TM

Where Innovation is LIFE

TM

Where Innovation is LIFE

SALIENT FEATURES
Practically maintenance free Robust design and construction Encapsulation of rotary pedestals and heads No significant change of contact resistance over many years of service Constant contact pressure Stable rotary pedestals ensure no deflection even with high static loads.

INTERLOCKS
On request the following interlocking arrangement can be provided Disconnectors and earthing switches manual operator. Disconnecors with a motor operated mechanism & with manual operating mechanism A blocking magnet can be installed as an additional interlocking facility. The operating mechanisms can be provided with a lockable door

STANDARDS
The disconnectors comply with the requirement of IS9921/ 9920, IEC - 129 and IEC - 694, IEC -62271-102 2001 and Part 1000 and most other international standards.

INSULATORS
A wide range of insulators meeting the requirement of IEC : 168 or ISS 2544 for 420 / 245 / 145 / 36 / 12 kV insulators respectively of the stack/ solid core type with various cantilever strength, creepage distance and insulation levels can also be supplied along with disconnectors.

TESTS & QUALITY CONTROL


Successful type tests on the disconnectors have been carried out in our own and independent test laboratories in accordance with the latest Indian and international standards. Quality control in individual parts during manufacture ensures consistent product quality. Each equipment is subjected to the routine test as per relevant standard at our works before dispatch.

RESEARCH AND DEVELOPMENT


We are constantly working on developing new products and improvementing the existing design. In line with the latest technological advancements we have successfully developed a wide range of design to suit site requirements.

A.C. MOTOR OPERATING MECHANISMS


Disconnectors can be provided with manual or A.C. / D.C. motor operated mechanisms. Normally gang operated mechanisms are offered. But on specific request individual three pole electrical gang operation can also be provided. The earthing switch consist of moving / fix contact, provided with silver plated contacts at both ends. The earthing switches have been designed constructionally interlocked with the main isolator so that the earthing switches can be operated only when the isolators is open and vice versa in addition to that electrical interlocks also provided for 400 KV Isolators and above.

INSTALLATION
All disconnectors and earthing switches are preassembled and adjusted in our works. The construction is designed in such a way that installation at site can be done very easily without need of any special tools. The phases can be installed in series. In parallel (normal) and tandem type as per site requirement and application.

MAINTENANCE
The disconnectors and earthing switches made by Elektrolites are virtually free of maintenance. However to ensure a long and trouble-free service period we advise to carry out a visual inspection of the equipment once every three years.

TM

Where Innovation is LIFE

(POWER) PVT. LTD.

INTRODUCTION
'Elektrolites' started in 1966 with trading in power station equipments. The company commenced production of 11 kV Isolator in 1982 and with the induction of technocrat Mr. Anil Saboo, expanded its product range upto 420 kV. The company further diversified in 2008 into various electro-mechanical products for power sector upto 800 kV range at its newly built world class industrial complex at Bagru in Jaipur district (Rajasthan)

APPLICATION
These disconnectors are , no load switching devices which physically isolate the lines. They are designed for horizontal outdoor application and can also be designed for vertical installation. For earthing and closing of switchyard portions of the installation, the earthing switches are provided on disconnector. If required.

RATING
CURRENT RATING 400 Amps 630 Amps 800 Amps VOLTAGE RATING 12 kV 36 kV 72.5 kV 1250 Amps 2000 Amps 2500 Amps 110 kV 145 kV 245 kV 3150 Amps 4000 Amps

420 kV 765 kV

GENERAL
The Isolators and Accessories conform in general to IEC 62271-Part-102-2002 or IS 9921 / 9920, IEC -129 to IEC 694.

DESIGN
Our designs are proven over two decades. Special care is taken to keep low contact resistance through out life of Isolator and maintenance free smooth operations. The Main / Earth contact are of self aligning and so designed that binding cannot occur after remaining closed for a long periods of time in a heavily polluted atmosphere. The contacts and S.S. Spring are so designed that contacts independently sprung and full pressure is maintained on all contact at all times. Contact springs are insulated and will not carry any current and not loose their characteristics due to heating effect. All current carrying parts are made of hard drawn electrolytic copper and silver plated.

TYPES
(a) Center Break (b) Double Break Turn & Twist (c) Double Break Banging (d) Vertical Break (e) Semi Pentograph (f) Pentograph

TM

Where Innovation is LIFE

CENTRE BREAK - SERIES EC


Very low operating torque Self-wiping contacts Vertical/Horizontal terminal take off. Simultaneous operation of three poles by single operating mechanism upto 420 kV Individual pole operation for 400 kV

CSB

Main Dimension (mm)

Rated Rated Voltage current

Rated short time current

Rated inputs withstand voltage 1.2/50s

a 700 1100 1700 2700 2700 4800 7000

- b

c 450 800 2000 2000 2000 4000 6000

kV 36 72.5 145 170 245 420 765

A
630/ 1250 1250/ 3150 800 1250/ 2500 2000 3150 1250/ 2500 2000/ 3150 3150/ 4000

kA 25 31.5 40 40 40 50 50

kVp 170 325 650 750 1050 1425 3000

kVp 195 375 750 860 1200 1425 3000

- 1000 - 1400 - 2125 - 2900 - 2800 - 4800 - 7000 -

CENTRALROTATING SERIES ED
Turn and twist contacts for higher current rating Vertical/Horizontal terminal take off B a n g i n g t y p e Tu b u l a r contacts for lower current rating Simultaneous operating of three poles by single operating mechanism upto 420 kV Individual pole operating for 800 kV and above

DBCR

Main Dimension (mm)

Rated Rated Voltage current

Rated short time current

Rated inputs withstand voltage 1.2/50s

a 600 800 1200 2000 2800 4800 7000

- b - 265 - 850

c 375 450 500 1500 2500 3000 4500

kV 12 36 42.5 145 245 420 765

A
400/500 630/ 1250 2000/ 3150 1250/ 2000 2000/ 3150 3150/ 4000 3150/ 4000

kA 16/25 25/31.5 40 31.5/40 40 40/50 50

kVp 75 170 325 650 1050 1425 3000

kVp 85 195 370 750 1200 1425 3000

- 1300 - 2100 - 2800 - 4400 - 6500 -

TM

B I

TM

ELEKTROLITES (POWER) PVT. LTD.


UNIT I : S-758 (A), Road No. 9F, VKI Area, JAIPUR - 302 013 India Phone : + 91-141-2330576, 2331624 Fax : + 91-141-2333572 E-mail : info@elektrolites.com Website : www.elektrolites.com UNIT II : E-148 to 150, RIICO Ind. Area extn. Phase-II, BAGRU-303007 (Jaipur)

Where Innovation is LIFE

ISO 9001:2008 Company