Lecture5 - Electrocardiogram Electromyogram - 1
Lecture5 - Electrocardiogram Electromyogram - 1
Lecture5 - Electrocardiogram Electromyogram - 1
of the Hearth
And
Electrocardiogram
And
Electromyogram
§ Anatomy of the Heart
n The heart is a muscler organ the size of a large fist whose primary
function is to pump oxygen-rich blood throughout to body.
n Its anatomy is divided into two “mirrored” sides, left and right, which
support different circulatory systems but which pump in a
synchronized, rhythmic manner.
• Each side of the heart consists of
two chambers:
– The atrium à where the blood
enters
– The ventricular à where the
blood is forced into further
circulation.
Anatomy of the Heart (Cont.)
– Atrioventricular valves
• which are located between the
atria and the ventricles.
– Pulmonary and aortic valves
• which are located between the
ventricles and the arteries.
• A cardiac cycle can be assumed to start in the right atrium where the
blood is collected from all the veins in the body except those of the
lungs.
• When the right atrium is triggered to contract, it forces blood into the
right ventricle.
• When the right ventricle has been filled, it contracts and forces blood
into the lungs, where excess corbon dioxide is replaced by oxygen.
Anatomy of the Heart (Cont.)
5 mm
n The dark horizontal lines are 0.20 second 0.2 sec
(5 mm) apart. 1 mm
0.04 sec
n The light horizontal lines are 0.04 second 5 mm
0.5 mV
(1 mm) apart.
n The dark vertical lines are 5-mm apart
(0.5 mV)
n The light vertical lines are 1-mm apart
(0.1 mV).
ECG Waves and Time Intervals (Cont.)
• P wave
– depolarization of the right and left atria.
– positive polarity and a smooth morphology.
– its amplitude is normally less than 300uV
– its duration is less than 120ms.
– below 10-15Hz.
• QRS complex
– depolarization of the right and left ventricles.
– its duration is about 70-110ms.
– it has the largest amplitude of the ECG waveforms, sometimes reaching
2-3mV.
– the frequency content of the QRS complex is concentrated in the
interval 10-50 Hz.
ECG Waves and Time Intervals (Cont.)
• T wave
– reflects ventricular repolarization and extends about 300ms after the
QRS complex.
– The position of this wave is strongly dependent on the heart rate,
becoming narrower and closer to QRS complex at rapid rates.
– This contraction property does not apply to the P wave or the QRS
complex.
– The normal T wave has a smooth, rounded morphology which is
associated with a single positive peak.
ECG Waves and Time Intervals (Cont.)
• RR interval
– the length of a ventricular cardiac cycle measured between to succesive
R waves.
– is the fundamental rhythm quantity in any type of ECG interpretation.
– is used to characterize different arrhythmias as well as to study heart
rate variability.
• PQ interval
– time interval from the onset of atrial depolarization to the onset of
ventricular depolarization.
– This interval reflects the time required for the electrical impulse to
propagate from the SA node to the ventricles.
• QT interval
– represents the time from the onset of ventricular depolarization to the
completion of ventricular repolarization.
– Prolongation of this interval has been observed in various cardiac
disorders associated with increased risk of sudden death.
§ ECG Rhythms
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
ECG Rhythms (Cont.)
§ 12-Lead ECG - Einthoven’s Triangle
In 1924, Einthoven was awarded the
Nobel Prize in Medicine for inven6ng the first
prac6cal system of electrocardiography used in
medical diagnosis.
Williem Einthoven
1860-1927
12-Lead ECG - Einthoven’s Triangle (Cont.)
§ ECG leads
• An ECG lead is a record of the electrical activity generated by the
heart that is sensed by either one of two ways:
– two discrete electrodes of opposite polarity
– one discrete positive electrode and an “indifferent,” zero reference
point.
• A lead composed of two discrete electrodes of opposite polarity is
called a bipolar lead.
• A lead composed of a single discrete positive electrode and a zero
reference point is a unipolar lead.
• Depending on the ECG lead being recorded, the positive electrode may
be attached to
– the right arm
– the left arm
– the left foot
– around chest (in total 6 electrodes)
• The negative electrode is usually attached to an opposite arm or foot or
to a reference point made by connecting the limb electrodes together.
§ 12-Lead ECG
• For a detailed analysis of the heart’s electrical activity, usually in the hospital
setting, an ECG recorded from 12 separate leads (the 12-lead ECG) is used.
• The 12-lead ECG is also used in the prehospital phase of emergency care in
certain advanced life support services to diagnose acute myocardial infraction and
to help in the identification of certain arrhythmias.
• A 12-lead ECG consists of
– Three standard (bipolar) limb leads
• lead I
• lead II
• lead III
– Three augmented (unipolar) leads
• lead aVR
• lead aVL
• lead aVF
– Six precordial (unipolar) leads (V1, V2, V3, V4, V5, and V6)
• When monitoring the heart solely for arrhythmias, a single ECG lead, such as the
standard limb lead II, is commonly used, especially prehospital phase of
emergency care.
12-Lead ECG - Limb Leads (Cont.)
where
n VI + VIII = VII
Watch
video#2