Hand Expansion Valves Bulletin No.

82-00A

“Built Stronger to Last Longer”


Sizes: 6mm (¼”) to 305mm (4”)
Suitable For: Ammonia, Fluorocarbons,
Nitrogen and Carbon Dioxide

Features
• ASTM 352 LCB Cast Steel Body (1/4” thru 2”)
• Maximum Safe Working Pressure 400 PSIG
• Fluid Temperature Range: -60°F to +300°F
• Stainless Steel Stem
• Optional Stainless Steel Trim May 2004
• Reliable Back Seating Installation, Service and Parts Information
• Complete Line of Bolted Bonnets
• 25% Carbon Filled PTFE Seat (1/4” thru 2”)
• Available Connections: MACHINED
BONNET BORE PACKING NUT
¼” thru 1-1/2”, Screwed End
¼” thru 2”, Socket Weld
1-1/4” thru 2”, Butt Weld CARBON PTFE
• “T” Pattern Globe Body For Easy Insulation O-RING CARRIER
• Extended Bonnets For Thicker Insulation CARBON PTFE
WASHERS NON ASBESTOS
Description GRAPHITE
PACKING
This complete line of all steel bodied valves with
bolt-on bonnets are designed and built to maintain
reliability both in their seating and back seating
functions. This entire line is supplied with stainless
steel stems and backseating capability. Corrosion
resistant, high-grade stainless steel trim is available R/S Bonnet Design
upon request. A unique carbon filled PTFE seat is (Typical of 3/4" and 1")
standard throughout the line, lending durability to the
seating surface. In addition a dual O-Ring stem
packing design along with a stem packing seal is
standard on all valves from ¼” thru 2”. This innova-
tive design seals both the valve stem and bonnet resistance will be negligible allowing the valve to be
bore with independent O-Rings, which are captured easily repositioned.
in a carbon PTFE carrier. The addition of the pack-
ing provides for backup sealing capability in the Note: The New Hand Expansion Valve plugs
unlikely event of an O-Ring failure. and Bonnet Assemblies wil not retrofit to either
a prior design hand expansion valve body or to a
A packing nut design with either 1/4” or 5/16” flats prior design stop valve.
provide a generous wrench engagement area, with
little likelihood of “rounding” the flat. With the O-Ring The extended bonnet is available for globe style
cartridge used in all valve bonnets, there will typi- valves in the Tee body configuration and in angle
cally be no need to loosen the packing nut when style bodies. Bonnet bolts, extension boss boss
opening or closing a valve. In most cases, stem clamp, packing nut, and stem are all of 300 series
corrosion resistant stainless steels.

Refrigerating Specialties Division 1


309278
Screwed End (1/4"- 1-1/2") Angle

Screwed End Angle HEV Dimensions In Inches


Valve Size L L1 H H1 D
1/4" Angle 1.75 1.75 4.50 7.25 2.50
3/8" Angle 1.75 1.75 4.50 7.25 2.50
1/2" Angle 1.75 1.75 4.50 7.25 2.50
3/4" Angle 1.50 2.00 5.75 8.50 2.50
1" Angle 1.50 2.00 5.75 8.50 2.50
1-1/4" Angle 1.63 2.50 8.00 9.25 3.25
1-1/2" Angle 1.63 2.50 8.00 9.25 3.25

Screwed End (1/4" - 1-1/2") Globe

Installation
Screwed End. The most important factor other than the
valve itself in achieving a leak-tight and secure threaded
valve installation is selection and preparation of mating
piping. Pipe 1-1/2” and smaller should be Schedule 80
Steel ASTM A-106 Grade B or equal, properly cut to
correct length and cleanly and properly threaded with U.S.
National Tapered Male Pipe Threads. The male thread
sealant is recommended. Sealant should be applied
evenly to act as a lubricant between the threads to avoid
any chance of metal to metal galling. Valve and piping
should be adequately tightened with two wrenches posi-
tioned as close together as possible, but not touching the
pipe threads. In horizontal piping of suction, overfeed gas
return, or condenser drain lines, glove valve or angle valve
stems should be should be horizontal to avoid liquid
trapping of gas flow at the valve body casting seat orifice.
Screwed End Globe HEV Dimensions In Inches
Before putting valves into service, all pipe connections, Valve Size L H H1 D
valve seats, bonnet seals and stem seals should be 1/4" Globe 3.75 5.75 7.25 2.50
tested for leaks at pressure levels called for in appropri- 3/8" Globe 3.75 5.75 7.25 2.50
1/2" Globe 3.75 5.75 7.25 2.50
ate codes
3/4" Globe 3.88 5.75 8.50 2.50
1" Globe 3.88 5.75 8.50 2.50
1-1/4" Globe 5.00 8.00 9.25 3.25
1-1/2" Globe 5.00 8.00 9.25 3.25

Refrigerating Specialties Division 2


SPARE PARTS FOR SCREWED END
HAND EXPANSION VALVES
PORT SIZE
ITEM DESCRIPTION 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2"
1,2,4,7 Tee Handle 204265 204265 204265 204265 204265 204276 204276
1,2,4,7 SS Tee Handle 205712 205712 205712 205712 205712 205713 205713
9 -12, Packing Kit 204471 204471 204471 204471 204471 204272 204272
9 -12, 16, 18 Plug Stem Kit Expansion 204309 204309 204309 204313 204313
9 -12, 16, 18 SS Plug Stem Kit Expansion 205675 205675 205675 205679 205679 205680 205680
9- 16, 18 Bonnet Assembly 205697 205697 205697 205701 205701 205702 205702
9- 16, 18 Bonnet Assembly, Extended 205698 205698 205698 205972 205972 205973 205973
16 Gasket Pkg, Bonnet 204281 204281 204281 204282 204282 204283 204283
8 Gasket Pkg, Seal Cap 204292 204292 204292 204292 204292 204292 204292

Note: The New Hand Expansion Valve plugs and


Bonnet Assemblies wil not retrofit to either a prior
design hand expansion valve body or to a prior
design stop valve.

Item Description
1 Screw, Cap
2 Lockwasher
3 Nameplate
4 Washer
5 Handwheel, std
5a Handwheel, deep
6 Seal Cap
7 Tee Handle
8 Gasket, Seal Cap
9 Packing nut
10 O-ring carrier
11 Washer
12 Packing
13 Cap, Thread
14 Bolt
15 Bonnet
16 Gasket
17 Plug/Stem Asy
18 Plug/Stem Asy
19 Plug/Stem Asy
20 Body
21 Gasket
22 Seat Disc
23 Washer
24 Retainer

Refrigerating Specialties Division 3


Socket Weld, Butt Weld. Welding valves may be Socket Weld (1/4" - 4") Angle
installed in horizontal or vertical pipelines. Stems may be
horizontal or vertical or angled upward. Globe valves in
horizontal suction lines or liquid overfeed return lines,
condenser drain lines, purge lines, oil pot drain lines and
level control column isolation valves should preferably
have stems horizontal rather than upward to avoid liquid
or gas trapping at valve seat orifices. Inlet pressure for
all valve sizes should normally be under valve seat disc.

The valve stem should be open during welding. Normally


it is not necessary to disassemble valves for welding.
However, if welding is prolonged enough to overheat the
body, a wet rag should be wrapped around the valve
bonnet and upper body during welding. The codes
applicable to the welding of socket weld valves require
that the pipe be inserted into the socket until bottomed
against the stop. The pipe is then to be backed out
approximately 1/16 of an inch before welding.
Socket Weld Angle HEV Dimensions In Inches
Use of welding rings is optional but recommended for Valve Size L L1 H H1 D
butt weld valves. They help alignment, control gap for 1/4" Angle 1.75 1.75 4.50 7.25 2.50
3/8" Angle 1.75 1.75 4.50 7.25 2.50
full penetration welding and reduce welding debris entry.
1/2" Angle 1.75 1.75 4.50 7.25 2.50
Welds should be annealed as necessary in accordance 3/4" Angle 1.50 2.00 5.75 8.50 2.50
with good practice. Painting of valves and welds is 1" Angle 1.50 2.00 5.75 8.50 2.50
recommended for corrosion protection. Pipe covering 1-1/4" Angle 2.75 2.75 7.88 9.00 3.25
where applied, should have proper moisture barrier. 1-1/2" Angle 2.75 2.75 7.88 9.00 3.25
2" Angle 3.12 3.12 8.38 10.25 3.25

Shut-off valves leading to the atmosphere, even if it is


temporary, must be plugged or capped to prevent
Socket Weld (1/4" - 2-1/2") Globe T
corrosion inside of the valve as well as leakage due to
vibration, pressure shock, or improper opening; the
valve seat should be cracked open to prevent hydro-
static expansion between the valve and the cap. Valves
should never directly feed a water tank because of
potential internal corrosion or seat opening caused by
vibration.

Before putting valves into service, all pipe connections,


valve seats, bonnet seals and stem seals should be
tested for leaks at pressure levels called for in appropri-
ate codes

Socket Weld Globe HEV Dimensions In Inches


Valve Size L H H1 D
1/4" Globe 3.75 5.75 7.25 2.50
3/8" Globe 3.75 5.75 7.25 2.50
1/2" Globe 3.75 5.75 7.25 2.50
3/4" Globe 3.88 5.75 8.50 2.50
1" Globe 3.88 5.75 8.50 2.50
1-1/4" Globe 7.00 8.88 9.00 3.25
1-1/2" Globe 8.25 10.00 9.00 3.25
2" Globe 8.25 10.00 10.25 3.25

Refrigerating Specialties Division 4


SPARE PARTS FOR SOCKET WELD
HAND EXPANSION VALVES
PORT SIZE
ITEM DESCRIPTION 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"
1,2,4,7 Tee Handle 204265 204265 204265 204265 204265 204276 204276 204276
1,2,4,7 SS Tee Handle 205712 205712 205712 205712 205712 205713 205713 205713
6,8 Cap Kit, Seal 204273 204273 204273 204273 204273 204274 204274 204274
9 -12, Packing Kit 204471 204471 204471 204471 204471 204472 204472 204472
9 -12,16,17 Plug Stem Kit, Expansion 204309 204309 204309 204313 204313 204315 204315 204316
9 -12,16,17 SS Plug Stem Kit, Expansion 205675 205675 205675 205679 205679 205681 205682 205682
9-16. 17 Bonnet Assembly Expansion 205697 205698 205699 205700 205701 205703 205703 205704
9-16. 17a Bonnet Assembly Extended 205968 205968 205968 205972 205972 205973 205973 205974
16 Gasket Pkg, Bonnet 204281 204281 204281 204282 204282 204283 204283 204284
8 Gasket Pkg, Seal Cap 204292 204292 204292 204292 204292 204292 204292 204292

Item Description
1 Screw, Cap
2 Lockwasher
3 Nameplate
4 Washer
5 Handwheel, std
5a Handwheel, deep
6 Seal Cap
7 Tee Handle
8 Gasket, Seal Cap
9 Packing nut
10 O-ring carrier
11 Washer
12 Packing
13 Cap, Thread
14 Bolt
15 Bonnet
16 Gasket
17 Plug/Stem Asy
18 Plug/Stem Asy
19 Plug/Stem Asy
20 Body
21 Gasket
22 Seat Disc
23 Washer
24 Retainer

Refrigerating Specialties Division 5


Butt Weld (1-1/4" - 12") Angle

Butt Weld Angle HEV Dimensions In Inches


Valve Size L L1 H H1 D
1-1/4" Angle 2.75 2.75 7.75 10.50 3.25
1-1/2" Angle 2.63 2.63 8.12 10.50 3.25
2" Angle 3.00 3.00 8.50 11.00 3.25

Item Description
1 Screw, Cap
2 Lockwasher
3 Nameplate
4 Washer
5 Handwheel, std
5a Handwheel, deep
6 Seal Cap
7 Tee Handle
8 Gasket, Seal Cap
9 Packing nut
10 O-ring carrier
11 Washer
12 Packing SPARE PARTS FOR BUTT WELD
13 Cap, Thread HAND EXPANSION VALVES
14 Bolt PORT SIZE
15 Bonnet ITEM DESCRIPTION 1-1/4" 1-1/2" 2"
16 Gasket 1,2,4,7 Tee Handle 204276 204276 204276
1,2,4,7 SS Tee Handle 205713 205713 205713
17 Plug/Stem Asy
9 -12, Packing Kit 204472 204472 204472
18 Plug/Stem Asy 9 -12,16,17 Plug Stem Kit, Expansion 204315 204315 204316
19 Plug/Stem Asy 9 -12,16,17 SS Plug Stem Kit, Expansion 205681 205681 205682
20 Body 9-16. 17a Bonnet Assembly Expansion 205703 205703 205704
21 Gasket 9- 16, 18 Bonnet Assembly, Extended 205973 205973 205974
16 Gasket Pkg, Bonnet 204283 204283 204284
22 Seat Disc 8 Gasket Pkg, Seal Cap 204292 204292 204292
23 Washer
24 Retainer

Refrigerating Specialties Division 6


Safe Operation (See also Bulletin RSB) Warranty
People doing any work on a refrigeration system All Refrigerating Specialties products are warranted
must be qualified and completely familiar with against defects in workmanship and materials for a
the system and the Refrigerating Specialties period of one year from date of shipment from
Division valves involved, or all other precautions originating factory. This warranty is in force only
will be meaningless. This includes reading and when products are properly installed, field as-
understanding pertinent Refrigerating Special- sembled, maintained, and operated in use and
ties Division product Bulletins and Safety Bulle- service as specifically stated in Refrigerating Spe-
tin RSB prior to installation or servicing work. cialties Catalogs or Bulletins for normal refrigeration
applications, unless otherwise approved in writing
Where cold refrigerant liquid lines are used, it is by Refrigerating Specialties Division. Defective
necessary that certain precautions be taken to avoid products, or parts thereof returned to the factory
damage that could result from liquid expansion. with transportation charges prepaid and found to be
Temperature increase in a piping section full of solid defective by factory inspection will be replaced or
liquid will cause high pressure due to the expanding repaired at Refrigerating Specialties option, free of
liquid that can possibly rupture a gasket, pipe or charge F.O.B. factory. Warranty does not cover
valve. All hand valves isolating such sections products that have been altered, or repaired in the
should be marked, warning against accidental field; damaged in transit, accidents, misuse, or
closing, and must not be closed until the liquid is abuse. Products disabled by dirt or other foreign
removed. Check valves must never be installed substances will not be considered defective.
upstream of solenoid valves, or regulators with The express warranty above constitutes the only
electric shut-off, nor should hand valve upstream of warranty of Refrigerating Specialties products, and
solenoid valves or downstream of check valves be is in lieu of all other warranties, expressed or im-
close until the liquid has been removed. It is advis- plied, written or oral, including any warranty of
able to properly install relief devices in any section merchantability or warranty of fitness for a particular
where liquid expansion could take place. purpose and in no event is Refrigerating Specialties
responsible for any consequential damages of any
Avoid all piping or control arrangements that might nature whatsoever. No employee, agent, dealer or
produce thermal or pressure shock. For the protec- other person is authorized to give any warranties on
tion of people and products, all refrigerant must be behalf of Refrigerating Specialties nor to assume for
removed from the section to be worked on before a Refrigerating Specialties any other liability in con-
valve, strainer, or other device is opened or re- nection with any of it products.
moved. Flanges with ODS connections are not
suitable for ammonia service.

Refrigerating Specialties Division 7


TR Flow Cap.vs. Turns Open:
1/2" H. Ex. V. HxTee Body; With or W/O Extended Bonnet

1000.0

100.0
TR, Log Sc.

10.0

1.0
1 10 100
Press. Diff., Psid

1-Turn 2-turns 4-Turns

TR Flow Cap.vs. Turns Open:


3/4" H. Ex. V. Tee Style; With or W/O Extended Bonnet

1000.0

100.0
TR, Log Sc.

10.0

1.0
1 10 100
Press. Diff., Psid

1-Turn 3-turns 5-Turns

Refrigerating Specialties Division 8


TR Flow Cap.vs. Turns Open:
1" H. Ex. V. Tee Style; With or W/O Extended Bonnet

1000.0

100.0
TR, Log Sc.

10.0

1.0
1 10 100
Press. Diff., Psid

1-Turn 3-turns 5-Turns

TR Capacity vs. Turns:


1-1/4" H. Ex. V.; T-Type or Extended Bonnet

10000.

1000.
TR, Log Sc.

100.

10.

1.
1 10 100
Press. Diff., Psid

1-Turn 3-turns 5-Turns 7-Turns

Refrigerating Specialties Division 9


TR Capacity vs. Turns:
1-1/2" H. Ex. V.; T-Type or Extended Bonnet

10000.

1000.
TR, Log Sc.

100.

10.

1.
1 10 100
Press. Diff., Psid

1-Turn 3-turns 5-Turns 7-Turns

Refrigerating Specialties Division 10


REFRIGERATING SPECIALTIES HAND VALVE SPECIFICATIONS
FLOW PATH GLOBE ANGLE GLOBE ANGLE GLOBE ANGLE
Connections Threaded & S.W. Threaded & S.W. S.W. & B.W.
Sizes 1/4", 3/8", 1/2" 3/4", 1", 1-1/4", 1-1/2" 2"
Bonnet Type Forged Steel Forged Steel Ductile Iron
Body Materials Cast Steel Cast Steel Cast Steel
Packing Materials Non-Asbestos Graphite Non-Asbestos Graphite Non-Asbestos Graphite
Seat Materials 25% Carbon Filled PTFE 25% Carbon Filled PTFE 25% Carbon Filled PTFE

TORQUE REQUIREMENTS
BOLT DIAMETER VALVE PORT SIZE TORQUE
5/16" (8mm) 1/4" - 1/2" (6 - 13mm) 11.0 ft lb (1.5 mkg)
5/16" (8mm) 3/4" - 1" (20 - 25mm) 12.5 ft lb (1.7 mkg)
3/8" (9.5mm) 1-1/4" - 1-1/2" (32 - 38mm) 20.8 ft lb (2.9 mkg)
7/16" (11mm) 2" (50mm) 25.0 ft lb (3.5 mkg)

PACKING NUT VALVE PORT SIZE TORQUE


1/4"- 4" (6 - 100mm) 2.5 ft lb (0.3 mkg)

Refrigerating Specialties Division 11