GC9C96

Heating Input: 40,000–100,000 BTU/h Two-Stage, Multi-Speed


ECM Gas Furnace
Up to 96% AFUE
Contents
Nomenclature......................................... 2
Product Specifications............................ 3
Dimensions............................................. 4
Airflow Specifications............................. 5
Wiring Diagrams................................... 10
Accessories........................................... 11

Standard Features Cabinet Features


• Energy-efficient, multi-speed ECM blower motor • Designed for multi-position installation —
• Heavy-duty, aluminized-steel tubular heat exchanger down flow, horizontal left or right
• Stainless-steel secondary heat exchanger • Certified for direct vent (2-pipe)
• Two-stage gas valve provides quiet, economical heating or non-direct vent (1-pipe)
• Durable Silicon Nitride igniter • Easy-to-install top venting with optional side venting
• Quiet two-speed induced draft blower • Convenient left or right connection
• Self-diagnostic control board with constant for gas and electrical service
memory fault code history output to a LED • Cabinet air leakage (QLeak) ≤ 2%
• Color-coded low-voltage terminals with provisions • Heavy-gauge steel cabinet with durable finish
for electronic air cleaner and humidifier • Fully insulated heat exchanger and blower section
• Low continuous fan speed options offer quiet air circulation • Airtight solid bottom or side return with easy-cut tabs
• All models comply with California 40 ng/J for effortless removal in bottom air-inlet applications
Low NOx emissions standard
• Can no longer be installed in California’s South Coast
Air Quality Management District (SCAQMD)
on or after October 1, 2019.
• AHRI Certified; ETL Listed

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long
as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Québec.

SS-GC9C96 www.goodmanmfg.com 9/21


Nomenclature

G C 9 C 96 040 4 C * **
1 2 3 4 5,6 7,8,9 10 11 12 13,14

Brand Engineering
G - Goodman® Brand Major/Minor Revisions
A - Initial Release
B - 1st Revision

Configuration NOx
M - Upflow/Horizontal N = > 40 NG/J NOx
C - Downflow/Horizontal X = < 40 NG/J NOx

Motor Cabinet Width


9 - Nine Speed ECM A - 14" C - 21"
B - 17½" D - 24½"

Gas Valve Maximum CFM


C - 2 Stage 3 - 1200 CFM 4 - 1600 CFM
5 - 2000 CFM

AFUE MBTU/h
80 - 80% AFUE 92 - 92% AFUE 030 - 30,000 BTU/h 080 - 80,000 BTU/h
96 - 96% AFUE 97 - 97% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h
060 - 60,000 BTU/h 120 - 120,000 BTU/h

2 www.goodmanmfg.com SS-GC9C96
Product Specifications

GC9C96 GC9C96 GC9C96 GC9C96


0403BNA 0603BNA 0803BNA 1005CNA
Heating Data
High Fire Input¹ 40,000 60,000 80,000 100,000
High Fire Output¹ 38,400 57,600 76,800 96,000
Low-Fire Input¹ 28,000 42,000 56,000 70,000
Low-Fire Output¹ 26,880 40,320 53,760 67,200
AFUE² 96 96 96 96
Temp. Rise Range (°F) 25- 55 25- 55 40- 70 35- 65
Vent Diameter³ 2"- 3" 2"- 3" 2"- 3" 2"- 3"
No. of Burners 2 3 4 5
Circulator Blower
Available AC @ 0.5" ESP 1.5- 3 1.5- 3 1.5- 3 3- 5
Size (D x W) 10" x 8" 11" x 8" 11" x 8" 11" x 10"
Horsepower @ 1075 RPM 1/2 1/2 1/2 1
Speed 9 9 9 9
Electrical Data
Min. Circuit Ampacity⁴ 8 8 8 13.3
Max. Overcurrent (amps)⁵ 15 15 15 20
Shipping Weight (lbs) 112 115 118 140
¹ Natural Gas BTU/h
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter, depending upon
furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or
3” diameter PVC.
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs
will require larger wire sizes.
⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½” FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
• For servicing or cleaning, a 24” front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed
above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

SS-GC9C96 www.goodmanmfg.com 3
Dimensions

A 6½
B
2⅝
C 1⅝ 2½ 18¼
1⅞
1⅜ 23 1⅞ Alternate Vent/

1½ Low-Voltage
Electrical Outlet

Low-Voltage
Electrical Outlet
14
Alternate Gas
Alternate
Gas Supply
High-Voltage
Electrical Outlet
25⅛
34½

25⅛
14⅞
14¾ 14¾

11⅜ 11⅜
6⅞ 6⅞
4⅛

High-Voltage
Drain Trap Holes 18⅛
2 D Electrical Outlet
Standard Drain Trap Unfolded Flanges
Unfolded Flanges
2½ 20⅛
E 2
3½ Folded Flanges
28¾ Folded Flanges
2⅝
Right-Side View
Front View Right Side Exterior
Drain Trap Holes
Air Air
Discharge Discharge

Air Air
Discharge Return
Model A B C D E
GC9C960403BNA 17½" 16" 13⅞" 12⅛" 13⅝"

GC9C960603BNA 17½" 16" 13⅞" 12⅛" 13⅝"

GC9C960803BNA 17½” 16” 13⅞” 12⅛” 13⅝”

GC9C961005CNA 21" 19½" 17⅜" 16" 17½"

Minimum Clearances to Combustible Materials

Position Sides Rear Front Bottom Flue Top


Downflow 0" 0" 3" NC 0" 1"
Horizontal 6" 0" 3" C 0" 6"
C = If placed on combustible floor, the floor MUST be wood ONLY.
NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

4 www.goodmanmfg.com SS-GC9C96
GC9C96 Low Stage Cooling Airflow Data

LOW STAGE COOLING AIFLOW


EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
THER-
MODEL MOSTAT TAP # 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CALL
CFM CFM CFM CFM CFM CFM CFM CFM
F01 727 677 623 565 510 455 403 351
F02 923 882 841 798 752 704 660 614
F03 632 574 510 448 388 332 277 234
F04^ 878 839 797 751 701 653 607 561
*C9C96
Y/Y1 F05 1106 1076 1044 1010 974 939 899 860
0403BN
F06 1188 1156 1123 1091 1062 1029 998 964
F07 1237 1205 1174 1145 1115 1081 1050 1016
F08 1281 1252 1222 1195 1163 1134 1104 1071
F09 1382 1354 1327 1302 1276 1246 1219 1190
F01 1167 1118 1069 1022 974 928 877 833
F02 1332 1289 1245 1200 1160 1120 1081 1036
F03 680 609 532 460 397 337 252 201
F04^ 903 839 783 719 661 601 546 497
*C9C96
Y/Y1 F05 1248 1204 1159 1113 1071 1028 983 943
0603BN
F06 963 907 852 803 745 689 639 587
F07 1393 1348 1309 1267 1230 1189 1152 1116
F08 1450 1407 1366 1330 1290 1251 1221 1186
F09 1468 1436 1393 1359 1323 1285 1248 1210
F01 1167 1124 1087 1040 995 954 916 869
F02 1317 1277 1240 1201 1161 1122 1081 1045
F03 733 669 606 543 482 424 372 300
F04^ 1217 1174 1130 1086 1045 1003 962 925
*C9C96 F05 1300 1263 1225 1186 1142 1099 1062 1023
Y/Y1
0803BN
F06 919 872 820 764 711 658 605 553
F07 1126 1085 1042 998 953 910 866 824
F08 1375 1341 1301 1264 1226 1189 1154 1118
F09 1440 1402 1366 1330 1295 1260 1224 1187
F01 1366 1307 1248 1188 1130 1069 1007 938
F02 1833 1785 1736 1688 1640 1593 1543 1497
F03 1295 1230 1168 1105 1044 981 911 843
F04^ 1634 1578 1525 1471 1416 1363 1311 1265
*C9C96
Y/Y1 F05 2028 1994 1937 1899 1863 1814 1769 1724
1005CN
F06 1773 1721 1671 1621 1571 1521 1470 1421
F07 1908 1860 1813 1766 1720 1672 1624 1578
F08 1965 1919 1873 1829 1783 1736 1688 1643
F09 2096 2053 2014 1973 1931 1890 1849 1803

Notes
• ^ DEFAULT SPEED
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

SS-GC9C96 www.goodmanmfg.com 5
GC9C96 High Stage Cooling Airflow Data

HIGH STAGE COOLING AIFLOW


EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
THER-
MODEL MOSTAT TAP # 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CALL
CFM CFM CFM CFM CFM CFM CFM CFM
F01 727 677 623 565 510 455 403 351
F02 923 882 841 798 752 704 660 614
F03 632 574 510 448 388 332 277 234
F04 878 839 797 751 701 653 607 561
*C9C96
Y2 F05^ 1106 1076 1044 1010 974 939 899 860
0403BN
F06 1188 1156 1123 1091 1062 1029 998 964
F07 1237 1205 1174 1145 1115 1081 1050 1016
F08 1281 1252 1222 1195 1163 1134 1104 1071
F09 1382 1354 1327 1302 1276 1246 1219 1190
F01 1167 1118 1069 1022 974 928 877 833
F02 1332 1289 1245 1200 1160 1120 1081 1036
F03 680 609 532 460 397 337 252 201
F04 903 839 783 719 661 601 546 497
*C9C96
Y2 F05^ 1248 1204 1159 1113 1071 1028 983 943
0603BN
F06 963 907 852 803 745 689 639 587
F07 1393 1348 1309 1267 1230 1189 1152 1116
F08 1450 1407 1366 1330 1290 1251 1221 1186
F09 1468 1436 1393 1359 1323 1285 1248 1210
F01 1167 1124 1087 1040 995 954 916 869
F02 1317 1277 1240 1201 1161 1122 1081 1045
F03 733 669 606 543 482 424 372 300
F04 1217 1174 1130 1086 1045 1003 962 925
*C9C96 F05^ 1300 1263 1225 1186 1142 1099 1062 1023
Y2
0803BN
F06 919 872 820 764 711 658 605 553
F07 1126 1085 1042 998 953 910 866 824
F08 1375 1341 1301 1264 1226 1189 1154 1118
F09 1440 1402 1366 1330 1295 1260 1224 1187
F01 1366 1307 1248 1188 1130 1069 1007 938
F02 1833 1785 1736 1688 1640 1593 1543 1497
F03 1295 1230 1168 1105 1044 981 911 843
F04 1634 1578 1525 1471 1416 1363 1311 1265
*C9C96
Y2 F05^ 2028 1994 1937 1899 1863 1814 1769 1724
1005CN
F06 1773 1721 1671 1621 1571 1521 1470 1421
F07 1908 1860 1813 1766 1720 1672 1624 1578
F08 1965 1919 1873 1829 1783 1736 1688 1643
F09 2096 2053 2014 1973 1931 1890 1849 1803

Notes
• ^ DEFAULT SPEED
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

6 www.goodmanmfg.com SS-GC9C96
GC9C96 Circulation Airflow Data

CIRCULATION AIFLOW
EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
THER-
MODEL MOSTAT TAP # 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CALL
CFM CFM CFM CFM CFM CFM CFM CFM
F01 727 677 623 565 510 455 403 351
F02 923 882 841 798 752 704 660 614
F03 632 574 510 448 388 332 277 234
F04 878 839 797 751 701 653 607 561
*C9C96
G F05 1106 1076 1044 1010 974 939 899 860
0403BN
F06 1188 1156 1123 1091 1062 1029 998 964
F07 1237 1205 1174 1145 1115 1081 1050 1016
F08 1281 1252 1222 1195 1163 1134 1104 1071
F09 1382 1354 1327 1302 1276 1246 1219 1190
F01 1167 1118 1069 1022 974 928 877 833
F02 1332 1289 1245 1200 1160 1120 1081 1036
F03 680 609 532 460 397 337 252 201
F04 903 839 783 719 661 601 546 497
*C9C96
G F05 1248 1204 1159 1113 1071 1028 983 943
0603BN
F06 963 907 852 803 745 689 639 587
F07 1393 1348 1309 1267 1230 1189 1152 1116
F08 1450 1407 1366 1330 1290 1251 1221 1186
F09 1468 1436 1393 1359 1323 1285 1248 1210
F01 1167 1124 1087 1040 995 954 916 869
F02 1317 1277 1240 1201 1161 1122 1081 1045
F03 733 669 606 543 482 424 372 300
F04 1217 1174 1130 1086 1045 1003 962 925
*C9C96 F05 1300 1263 1225 1186 1142 1099 1062 1023
G
0803BN
F06 919 872 820 764 711 658 605 553
F07 1126 1085 1042 998 953 910 866 824
F08 1375 1341 1301 1264 1226 1189 1154 1118
F09 1440 1402 1366 1330 1295 1260 1224 1187
F01 1366 1307 1248 1188 1130 1069 1007 938
F02 1833 1785 1736 1688 1640 1593 1543 1497
F03 1295 1230 1168 1105 1044 981 911 843
F04 1634 1578 1525 1471 1416 1363 1311 1265
*C9C96
G F05 2028 1994 1937 1899 1863 1814 1769 1724
1005CN
F06 1773 1721 1671 1621 1571 1521 1470 1421
F07 1908 1860 1813 1766 1720 1672 1624 1578
F08 1965 1919 1873 1829 1783 1736 1688 1643
F09 2096 2053 2014 1973 1931 1890 1849 1803

Notes
• ^ DEFAULT SPEED
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

SS-GC9C96 www.goodmanmfg.com 7
GC9C96 Heating Airflow Data

HEATING AIFLOW
EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
THER- TEMP TEMP
MODEL MOSTAT TAP # 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 RANGE RANGE
CALL LOW HIGH
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM
F01^ 727 34 677 37 623 40 565 44 510 49 455 403 351
W/W1 F03^^ 632 N/A 574 N/A 510 N/A 448 N/A 388 N/A 332 277 234

*C9C96 F04 878 28 839 30 797 31 751 33 701 36 653 607 561
20-50 25-55
0403BN F02^ 923 39 882 40 841 42 798 45 752 47 704 660 614
W2 F04 878 41 839 42 797 45 751 47 701 51 653 607 561
F05 1106 32 1076 33 1044 34 1010 35 974 37 939 899 860
F01^ 1167 32 1118 33 1069 35 1022 37 974 38 928 877 833
W/W1 F03^^ 680 N/A 609 N/A 532 N/A 460 N/A 397 N/A 337 252 201

*C9C96 F04 903 N/A 839 N/A 783 N/A 719 N/A 661 N/A 601 546 497
20-50 25-55
0603BN F02^ 1332 40 1289 41 1245 43 1200 44 1160 46 1120 1081 1036
W2 F04^^ 903 N/A 839 N/A 783 N/A 719 N/A 661 N/A 601 546 497
F05 1248 43 1204 44 1159 46 1113 48 1071 50 1028 983 943
F01^ 1167 43 1124 44 1087 46 1040 48 995 50 954 916 869
W/W1 F03^^ 733 N/A 669 N/A 606 N/A 543 N/A 482 N/A 424 372 300

*C9C96 F04 1217 41 1174 42 1130 44 1086 46 1045 48 1003 962 925
30-60 40-70
0803BN F02^ 1317 54 1277 56 1240 57 1201 59 1161 61 1122 1081 1045
W2 F04 1217 58 1174 61 1130 63 1086 65 1045 68 1003 962 925
F05 1300 55 1263 56 1225 58 1186 60 1142 62 1099 1062 1023
F01^ 1366 46 1307 48 1248 50 1188 52 1130 55 1069 1007 938
W/W1 F03^^ 1295 48 1230 51 1168 53 1105 56 1044 58 981 911 843

*C9C96 F04 1634 N/A 1578 N/A 1525 N/A 1471 N/A 1416 N/A 1363 1311 1265
30 - 60 35-65
1005CN F02^ 1833 48 1785 50 1736 51 1688 53 1640 54 1593 1543 1497
W2 F04^^ 1634 54 1578 56 1525 58 1471 60 1416 62 1363 1311 1265
F05 2028 44 1994 45 1937 46 1899 47 1863 48 1814 1769 1724

Notes
• ^ DEFAULT SPEED
• ^^NOT RECOMMENDED FOR HEATING
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

8 www.goodmanmfg.com SS-GC9C96
OUTPUT
BTUBTU TEMPERATURE
OutputvsVs. Temperature Rise CHART
RISEChart

SS-GC9C96
100

600 CFM
90
700

80 800

900

70 1000
1100

RISE
1200
60
1400

1600
50
1800

Temperature Rise
2000

TEMPERATURE

www.goodmanmfg.com
40 2200
2400 CFM

30
Formulas
FORMULAS
OUTPUT
BTUBTU/h Output== CFM 1.08
CFM xx1.08 x RISE
x Rise
20 BTU OUTPUT
RISE
Rise
= = BTU/H Output ÷ CFM
1.08
CFM x 1.08

10
30 40 50 60 70 80 90 100 110 120 130 140 150

OUTPUT BTU/HR
Output BTU/h x 1000
x 1,000

9
Temperature Rise Range Chart
Wiring Diagram — GC9C96******AA

GRD

GN
TO
GND 115 VAC/ 1 Ø /60 HZ

JUNCTION BOX
POWER SUPPLY WITH
ID BLOWER TWO-STAGE PRESSURE OVERCURRENT
PROTECTION DEVICE
SWITCH ASSEMBLY
HOT L

YL
GY SURFACE
OR
OR HIGH FIRE BK WARNING:DISCONNECT
IGNITER
PRESSURE POWER BEFORE
LOW FIRE SWITCH N SERVICING. WIRING
YL

C C
PRESSURE WH TO UNIT MUST BE

OR
NO NO PROPERLY POLARIZED
SWITCH DISCONNECT
AND GROUNDED.
2 CIRCUIT
2 1
CONNECTOR
OR TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH
HI 3 PU OVERCURRENT PROTECTION DEVICE
RD

L N
FLAME WARNING: GND
WH

BR
C


C 2 GY GY SENSOR
TWO STAGE NO
DISCONNECT POWER
GAS VALVE LO 1 BR BEFORE SERVICING.
WIRING TO UNIT
(WHITE RODGERS)
MUST BE PROPERLY

sources may be present. Failure to do so may cause property damage, personal injury, or death.
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
POLARIZED AND
DISCONNECT
SOME UNITS MAY HAVE GROUNDED.
1 ROLL OUT SWITCH

PU
PU PK DOOR
SWITCH

BL
JUNCTION BOX
AUTO RESET PRIMARY
LIMIT CONTROL
RD
GND
INDUCED INDOOR
3 WH AIR
DRAFT CIRCULATOR
2 RD BLOWER BLWR
RD

1 BK
GND

BURNER COMPARTMENT GND


LINE NEUTRAL

BLOWER COMPARTMENT

INTEGRATED CONTROL MODULE


RD

INTEGRATED CONTROL MODULE


WH

AUTO RESET HUM-OUT


PU
PU

AUXILIARY NEUTRAL
HUMIDIFIER
LIMIT CONTROL YL PK
RD

HUM
EAC NEUTRAL
ELECTRONIC
AIR CLEANER

IND HI
NEUTRAL
ID
BLWR
BK

IND LO NEUTRAL
IGN

HOT SURFACE
IGNITER
BK
WH

FS
WH

BK
WH

FLAME SENSOR
E39

E20
E15

E1

E2
E6
E4

E7
E3

E8
E5

LINE 115 VAC NEUTRAL


EAC-H
XFMR-H
CIRC-H
LINE-H
LINE-N
XFMR-N
HUM-N
EAC-N
CIRC-N
NEUT1
NEUT2

40 VA
TRANSFORMER
24 VAC
TH (3)
RD

1 5

RLO (6)
PU

W14 E26 E25


RD

WH

MANUAL RESET ROLLOUT LIMIT SWITCH


PU
WH

HUM-H
K8
R
BR

RLI (12) AUTO RESET


BL T1 AUTO RESET AUX LIMIT PRIMARY LIMIT
RD T2 TO
OR T3 +VDC
24V THERMOSTAT CONNECTIONS N.E.C. CLASS 2 WIRE

BK T4
Y1
YL T5
HLO (1)
RD COM
BR

LOW FIRE
PK

PRESS. SWITCH
BL
RD

6 R226
R223
PS1(5) C
W1
3 SW1 1 3 SW2 1 3 SW3
CENTER

RIGHT
LEFT

NO
3
2
1

PS2 (9)
PU

NO
6
5
4

W2
YL

Warning
C
12 9

10 7
11 8

TO HIGH FIRE
Y2 MICRO PRESS. SWITCH
READ CODES FROM LEFT TO RIGHT HLI (8)
G
PU
GY

MVL (10)
O LO
GY

INTEGRATED CONTROL MODULE DEHUM MVC (11) C


C
C NO
24V HUM

OR

MVH (4)
E21
HI
GAS
TWIN


E24

VALVE
TR (7)
VAC
115
VAC
24

W2 W/W1R G C Y/Y1 Y2 TO
BK R
BK

RD YL
OR ECM MTR
BL INDOOR
unit for the most up-to-date wiring.
Wiring is subject to change. Always
refer to the wiring diagram on the

HARNESS AIR
5

TO
4

CIRCULATOR
WH
TRANSFORMER
40 VA
3

N MICRO BLWR
GN
2

GND
BK
1

G GN
L BK INTEGRATED CONTROL MODULE
WH

C RD BK
NOTES:
GND 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
WH

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED


BLOWER WHEN SERVICING.
CHASSIS
CIRCULATOR BLOWER COMPARTMENT 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE
GROUND DOOR SWITCH MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL
(OPEN WHEN HAVING A TEMPERATURE RATING OF AT LEAST 105v C. USE COPPER
CONDUCTORS ONLY.
DOOR OPEN) 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.
AND LOCAL CODES.
Seven Segment Display 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT,
Status DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY
Seg# Seg# Seg# (NO THERMOSTAT INPUTS)
Internal Faults or IRQ Loss E E E COLOR CODES: EQUIPMENT GND
Lockout Due to Excessive Retries Recycle E E 0 PK PINK FIELD GND
Low Stage Pressure Switch Stuck Closed E E 1 BR BROWN
FIELD SPLICE
Low Stage pressure Switch Open E E 2 WH WHITE
Open High Limit Switch E E 3 BL BLUE SWITCH (TEMP.)
GY GRAY
Flame Detected When no Flame Should be E E 4 RD RED
IGNITER
Open Fuse E E 5 YL YELLOW SWITCH (PRESS.)
Low Flame Signal E E 6 OR ORANGE OVERCURRENT
Ignitor Relay Fault E E L PU PURPLE PROT. DEVICE
High Stage Pressure Switch Stuck Closed E E 8 GN GREEN JUNCTION
BK BLACK
High Stage Pressure Switch Open E E 9 TERMINAL
Reversed Line Polarity or Grounding Error E E A INTERNAL TO
Internal Gas Valve Error E E b INTEGRATED CONTROL
External Gas Valve Error E E C PLUG CONNECTION
Open Rollout Switch E 1 1 LOW VOLTAGE (24V)
ignitor Open E E N LOW VOLTAGE FIELD
Inducer Relay Error E E j HI VOLTAGE (115V)
TWIN Error E E H HI VOLTAGE FIELD
GROUNDING ERROR E 1 0 0140F02639-A

10 www.goodmanmfg.com SS-GC9C96
Accessories

GC9C96 GC9C96 GC9C96 GC9C96


Model Description
0403BNA 0603BNA 0803BNA 1005CNA

72950 Concentric Vent Kit (2") √ √ √ √


72951 Concentric Vent Kit (3") √ √ √ √
CFSB17 Downflow Sub-Base 17.5" √ √ √ ―
CFSB21 Downflow Sub-Base 21" ― ― ― √
RF000142 Drain Kit-Horizontal Left Vertical Flue √ √ √ √
0170K00000S Flush Mount Vent Kit- 3" or 2" √ √ √ √
0170K00001S Flush Mount Vent Kit- 2" √ √ √ √
AFE18-60A Fossil Fuel (Dual Fuel) Kit √ √ √ √
HASFK High-Altitude Natural Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-2

HASFK High-Altitude LP Gas Kit TBD TBD TBD TBD

0270F05405 Horizontal Drain Tubing Kit √ √ √ √


LPLP03 Low LP Gas Pressure Switch √ √ √ √
LPM-08 LP Conversion Kits √ √ √ √

SS-GC9C96 www.goodmanmfg.com 11
Notes

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs
without notice or without incurring obligations. © 2021 Goodman Manufacturing Company, L.P. • Houston, Texas

12 www.goodmanmfg.com SS-GC9C96