HRP Grid
HRP Grid
HRP Grid
EXPLANATION
S AND CLO
GUIDANCES SE
Assessor(s)
Supplier type
name(s)
Decathlon staff
Supplier status in charge of
HRP at
supplier
Did Decathlon
Number of employees staff attend the
evaluation?
Rate
Level: C 59%
:
Temp
CHA Comp REQUIRE orally
solved
CHAPTER
PTER l iance MENT REQUIREMENT Ans Com GUIDANCE & DEFINITIONS (NEW) Com
LEVE Rate LEVEL wer plies? during ments
L assess
ment?
Temp
orally
C ### REQUIRE
MENT 1 - CHILD Ans Com solved Explanation of the requirement Com
x
Specifically, a remediation procedure must define who in the supplier site is responsible for taking
which actions in case child labor is found. All parties should be aware of their responsibilities and
actions they must take.
2.0
country?
2. Male/Female ratio
Migrants : Any
INFO / person who is
2.0 PREPA recruited by a 3rd
party in one
country/province for
employment in a
company in another
country/province.
The scope of this
definition is
applicable to both
foreign and inter-
state/province (local)
migrants.
% of migrant
workers:
2.0 INFO / 1. Under supplier
x
PREPA contract
2. Under external
contract
If there are migrant
workers under
external contract,
2.0 INFO / what are the names
x
D responsibilities to
mitigate the risk of
forced labor when
using
intermediaries to
source workforce ?
Guidance:
A legal contract must be signed between the supplier site and its recruitment agency/broker.
Does the supplier The legal contract should cover the following:
2. have a legal 1. Suppliers' commitment to ethical recruitment.
ADVANCE contract with its 2. The due diligence procedures which shall be carried out.
2.12 No NOK
x
D labor 3. The list of sub-agents or headhunters involved and their nature of business.
agents/brokers? 4. The legal authorization certificate of the labor agency, attached to the contract.
5. The contract entry and validity date.
6. Duly signed by an authorized signatory
Also see Ethical Recruitment Guidelines section 2.4
Has the supplier Guidance: Risk Mapping should cover, at a minimum:
2.
2.13 done Risk Mapping No NOK 1. The legal framework of recruitment agencies in sending and receiving countries.
ADVANCE
x
of its labor supply 2. The risks for migrant workers in supply chains and countries. (Suppliers’ HR teams should do
D
chain ? a risk assessment based on the ILO indicators of forced labor)
3. The labour supply chain. (Suppliers HR teams should map the labour supply chain).
Also see Ethical Recruitment Guidelines section 2.1
Does the supplier Guidance: Due diligence means the supplier takes all reasonable measures to know of the business
conduct due structure, cost structure and relationships of recruitment agencies both in the host and origin country.
2. diligence of its The supplier takes reasonable measures to ensure the whole recruitment process is conducted legally
2.14 ADVANCE labor supply chain, No NOK and without any exploitation of workers.For a detailed due diligence checklist, see Decathlon
x
D contract clearly
stipulating
employment
conditions in their
local language?
If recruiting Guidance: Workers should not pay to work. The supplier should pay all recruitment fees, including
migrant workers, transportation, visa, and medical exams, among others. Fees that a worker must pay by law, such as
does the supplier airport departure fees or visa fees, the supplier must reimburse to the worker after the worker has
pay all legally paid.
allowed fees For more details on fees to be paid by the supplier, Also see Ethical Recruitment Guidelines
2.
associated with the section 3.2
2.16 ADVANCE No NOK
x
pre-departure For more details on what should be included in the pre-departure orientation, Also see Ethical
D orientation? Recruitment Guidelines section 3.3
Do migrant Guidance: When a worker arrives in the work country, the supplier should give an orientation that
2. workers receive introduces the new job, safety, rights, culture, among other details.
ADVANCE post-arrival For more details on what should be included in the post-arrival orientation, Also see Ethical
x
2.18 No NOK
D orientation/inductio Recruitment Guidelines section 4.1
n and support?
In case of Guidance: Any back pay, deposits taken, unpaid holidays, savings and legally entitled social
2. termination of a benefits like pension, etc.
ADVANCE migrant worker, Please refer to section 6.1 of Ethical recruitment guidelines
x
2.19 No NOK
D does the supplier
ensure the safe
return of the
worker to his home
country/province?
In case of
termination of a
2. migrant workers,
2.20 ADVANCE does the supplier No NOK
x
plies? during
LEVEL
ASSOCIAT assess Com
ment?
ION ments
Are there any
organizations of
INFO / worker
3.0 PREPA representatives
(trade union or free
association)?
INFO / Which
3.0 PREPA organization(s)?
What is the job
INFO /
3.0 content of the
PREPA
representatives?
Date of last
INFO /
3.0 representatives
PREPA
election:
Are employees
INFO / subject to a
3.0 PREPA collective
bargaining
agreement?
Does the facility
had any public
3.0 INFO / labour dispute in
PREPA the last 2 years
(e.g.: strike,
demonstration...)?
What is the role of
INFO / worker/union
PREPA representative
x
3.0
provided by the
local regulation?
What are the
requirements
INFO / regarding
3.0 worker/union
x
PREPA
representative
elections stipulated
by local regulation?
Are all workers, Guidance: The supplier should not take any measures to restrict this freedom such as acts that
regardless of their establish or promote the domination, financing or control of a trade union by employers.
1. contractual status, Consistent with country law, in cases where a single union represents employees, the supplier shall
3.1 CONSOLI free to join a union Yes OK not attempt to influence or interfere in employees’ ability to form other organizations that represent
DATED or employee employees. The supplier will not interfere with the right to freedom of association by favoring one
representative union over another.
group of their The use of “blacklists” to contravene the right to freely associate, for instance, blacklists based on
choosing? union membership or participation in lawful union activity, is specifically prohibited
If there is no union, Guidance: Where country law substantially restricts freedom of association, the supplier shall
is there an facilitate alternative means such as Workers participation committee, workers committee, workers
alternative worker welfare committee to individually and collectively engage with its employees and for employees to
1. representative express their grievances and protect their rights regarding working conditions and terms of
3.2 CONSOLI system available to Yes OK employment.
DATED workers, which
allows independent
and free association
and bargaining
regardless of
contractual status?
Are there worker Definition: Aware and capable means that worker representatives should have:- a job sheet that
representatives and includes their duties- access to training with regards to their duties- information on their
are they aware of and representation rightsGuidance: The supplier is encouraged as a good practice to allow reasonable
1. capable to execute time off with pay for employee/union representatives to carry out their duties, such as grievance
3.3 Yes OK
x
CONSOLID their roles and handling and representing members, and provide such facilities as may be reasonably required to
ATED responsibilities (e.g. enable the representatives to function effectively. The facilities and time-off which may be
sufficient HR time appropriate will vary depending upon the number of represented employees, number of worker
allocated)? representatives, provisions in the collective agreement, etc.
For internal Definition: Employees have the right to elect leaders and representatives of their unions
organizations without supplier interference, which includes acts that establish or promote the domination,
(internal union or financing or control of a trade union by employers.
free association),
1. have the
CONSOLI representatives
3.4 Yes OK
DATED been elected
without
interference from
the company and
according to local
legislation?
Are there regular Guidance: Supplier shall establish committee(s) comprised of worker and management
meetings between representatives that meet regularly (e.g. monthly) to adress any social-related incident or worker
1. worker grievance, ensure workplace inspections are performed, and make recommendations for actions by
3.5 CONSOLI representatives and Yes OK the committee. Maintain a log of such committee(s) activities and keep a copy available for review
DATED management
(frequency
following minimum
local legislation)?
Are the meeting Guidance: All employees should be informed of their right to join a union, how to engage with
minutes union representatives and the activities of such unions. Meeting minutes and details of worker
2. communicated to representatives should be posted prominently in the workplace.
3.6 ADVANCE all employees and No NOK
D the concerned
authority of
Government?
Does the supplier Guidance: An effective grievance process includes:
have an effective - Multiple channels for employees to raise concerns and provide input to management. For
process/procedure example: grievance/suggestion boxes; supervisors/team leaders; HR
2. by which employees department/counselors;
ADVANCE can raise trade union/worker representatives; “open door” policy; company “hotlines”; third-parties, worker
3.7 No NOK
D grievances? committees, worker voice survey, meetings between management and workers representatives, etc.;
Is the process - The ability to raise concerns confidentially (and/or anonymously), subject to the requirements
communicated and of country law, if the employee so desires without fear of retaliation.
understood by - A timely process for resolution with clear designation of responsibilities
people on site (HR, - A mechanism for employees to respond to and/or appeal the settlement of grievances
Effective communication of the grievance policy/procedures to employees so that employees are
security agents, line aware of the grievance process and their right to raise concerns, including posting of of details of
managers, etc..)? worker representatives prominently in the workplace-Training of staff responsible for responding to
grievances regarding the policy and their roles and responsibilities.
1. Legitimate: Mechanisms are fair and trustworthy
2. Accessible: To all who may be impacted by a company’s actions
3. Predictable: In terms of process and available outcomes (remedies)
4. Equitable: Fair and even access to information and advice for both sides of a complaint
5. Transparent: About the process and progress of grievances
6. Compatible with internationally recognized human rights
7. A source of continuous learning and improvement for the company
8. Based on engagement and dialogue with right’s holders and employee representatives
Are the grievances Guidance: Employees should be informed of the grievance resolution rate and the solution found
treated and is the where appropriate and only with prior consent of the concerned worker. Solutions to sensitive
2. result grievances such as sexual harassment should not be communicated to all workers. As a rule, the
3.8 ADVANCE communicated to No NOK name of any worker reporting a grievance should not be revealed to protect anonymity.
D all workers (if not
sensitive or
confidential)?
Definition: Reguar means at least annual. Teammate satisfaction surveys should be conducted
anonymously, they should be easily accessible and understandable for all workers. Worker surveys
should focus on continuous improvement rather than a total happiness score. Decathlon is using the
Engagement and Wellbeing Survey for this purpose, the survey can be made available to suppliers
upon request and is mandatory for partners in autonomy status.
Does the supplier
conduct regular
teammate If the supplier uses their own survey, this survey should be statistically sound and relevant e.g.:
satisfaction - Use a confidence interval of minimum 95%
surveys, analyze - Avoid leading questions
results (e.g. - Include control questions (e.g. ask questions with the same objective twice in different wording)
2. - Avoid absolutes like 'never', 'always' etc.
answers, response
3.9 ADVANCE No NOK - To focus on continous improvement it is better to use a lickert scale rather than yes/no questions
x
rate, repetition of
D
grievance) and
define The supplier is recommended to analyze worker voice survey on the following indicators (example
improvement only, defined by supplier)
actions? - Response rate (e.g. why is it low)
- Time it takes to resolve grievances
- Repetition of same grievances or improvement/stagnation/deterioration in score
- Type of grievances
- Root causes and corrective actions
- Improvement rate
The supplier should involve worker representatives and employee participation in the resolution of
grievances.
3.
3.FR
4.0
environmental
certifications?
List all the
equipments on-site
concerned by local
4.0 INFO / regulation and
x
PREPA requiring
certification (ex:
forklift, boiler,
pressurize tanks...)?
Does the supplier
site have the
required local
operating
1. authorizations
4.1 CONSOLI including supplier Yes OK Guidance: The supplier shall have relevant local operating authorizations including:- Building plan
DATED site license, on file for the production site and related supplier sites (dormitory, canteen and child care)- Fire
business license, License from local Fire Brigade- Building Compliance/Construction license (needs to be updated if
fire safety and structures change, needs to match with building plan and actual buildings (number of
updated building floor,activity))- Building facility has to match authorised purpose- Business / Supplier site
structure Operational License- Environmental Clearance/permission Certificate (if required)
compliance
documents?
Are electrical
installations in
good condition?
(e.g.: No burning or
overheating signs,
no multi looping,
no improper
connection joint, no
1. damaged wires,
4.2 CONSOLI loose wires or Yes OK
DATED exposed wires,
restricted access to Guidance: To guarantee the safety of the working stations and to ensure they are not susceptible to
high voltage areas, electrical shocks and/or fires.
electrical Electrical panels shall be labeled with proper signage mentioning maximum
distribution boxes voltage handled, accessible, and covered /dust & vermin proof or specified
kept locked, Cables Ingress Protection (IP) graded. Electrical wiring shall not be damaged or
suitably exposed and not pose a trip hazard. To prevent overloading, extension cords
insulated....) shall not be used instead of wall outlets for permanent electrical installations.
Are the equipments
concerned by local
regulation (forklift,
lifts, automatics
doors, boiler,
compressors,pressu
1.
rized
4.3 CONSOLI Yes OK Definition: Legal requirement in terms of inspections (frequency, certified organization...) has to be
tanks,crane…) in
DATED available.
good condition and
certified by a The following info's has to be in the maintenance and inspection reports:
recognized - Name and address of a certified company
- Date (matching with legal frequency)
organization?
If required by law, - Address (matching with address of the assessed site(s))
do they have the - Findings or non-conformities
legal licence? - Conclusion of the report => installation with or without risk
Are boilers and Guidance:Pressure equipment means steam boilers, pressure vessels, piping, safety valves and
1. pressurized tanks other components and assemblies subject to pressure loading which generally have over one litre in
4.4 CONSOLI (over 0.5 Bar) Yes OK volume and a maximum pressure load of more than 0.5 bar gauge. Such equipments shalle be
DATED safely located located outside of the workers production area and surrounded by walls or cages to minimize risk of
(separated from
production areas) any explosion and collateral damages. For details see Pressure Equipment Directive
with protection in (Source:Pressure Equipment Directive)
place (against
explosion)?
Is there a process to Definition: System could mean an reminder process or a procedure to ensure expiry date is notified
alert the to relevant person
2. responsible person
4.10 ADVANCE of expiry date for No NOK
x
D the legal
authorization and
certification?
3.
4.LE
plies? during
LEVEL
MANAGE assess Com
ment?
MENT ments
Number of pregnant
INFO / / in maternity leave /
5.0 PREPA breastfeeding
workers:
Risk
INFO / assessment/manage
5.0
x
Breaks or the reduction of daily hours of work shall be counted as working time and remunerated
accordingly.
Are all areas of the Guidance: There shall be appropriate protections on machines and shop floor to ensure immediate
premises safe risks are covered. (ex: mezzanines have full protection to prevent fall, pits are well covered)
1. and not causing
5.3 CONSOLI any injury to the Yes OK
DATED workers or putting
the worker at
immediate risk?
Are the machines Guidance: Dangerous machines shall be equipped with engineering controls such as completed
equipped with guard, two handed operation switches, sensors etc. to ensure the safety of operators.
sufficient and Safe operating procedures shall be posted visibly and follow at least what is provided by the
efficient machine designer/manufacturer.
protection/safety
1. devices (completed
5.4 Yes OK
CONSOLI guard, two handed
DATED operation switches,
sensors etc) on the
parts or
components that
are dangerous for
operators?
Do employees Guidance: Prior to starting a new job, workers receive necessary safety information on how to
receive basic health protect themselves from any direct hazards. As a minimum, the induction training covers appropriate
1. & safety training use of PPE relevant for job role and the safe handling of risk equipment.
5.5 CONSOLI on the appropriate Yes OK
x
Definition: Personal protective equipment (PPE) is used to create a protective barrier between a
Is PPE distributed
worker and hazards in the workplace. PPE includes such equipment as chemical resistant
and replaced free
1. gloves, safety shoes, hard hats, safety glasses, respirators, and clothing such as gowns and
of charge to the
5.7 CONSOLI personnel and Yes OK aprons.
Guidance: The supplier shall
x
risk assessment to respective risk (probability that a person will be harmed if exposed to a hazard). The scope of the
DATED
identify hazards, risk assessment should include assessment of machines, operational processes and the
evaluate risks and workstation/working environment. The risk assessment should be updated annually or in case of new
take corrective machines and/or new factory layout.
actions? (Including At the minimum a basic risk assessment should cover
fire safety, a. Identify hazards: Identification of tasks and their potential hazards for all operational processes
chemical safety...) (to identify hazards e.g. machine specifications/limits must be known)
Is the risk b. Evaluate risk: For each identified hazard evaluate the risk based on exposure (=probability that
assessment updated the hazard will occur) and severity (=potential damage to worker)
annually and e.g. in RISK = PROBABILITY x EXPOSURE x SEVERITY
case of new d.Take corrective actions: Where the risk is high, take immediate corrective actions
machines/new
chemical The risk assessment as an example can cover the following operational processes / aspects / hazards
formulations (based on necessity, example only, list non-exhaustive):
and/or new factory - Ergonomic risks based on workflow / workstation
layout? - heat stress (hot/ cold)
- Storage safety: Loading, unloading, storage of materials
- Machine safety: Machine purchase, installation, operation, maintenance, disposal
- Pressure vessels
- Electrical safety
- Fire safety
- Chemical safety
- Building safety (structure, Fall protection, etc;)
- Occupational exposure limits (noise, chemicals, fumes, heat, radiation, asbestos etc.)
- Hazardous operational processes such as hot work, abrasive blasting
- Emergency response cases
- Injury and illness hazards
- Disease hazards
- Sanitation (toilets, drinking water etc.)
- Risks related to dormitory use, canteen etc.
Guidance: The objective of a comprehensive risk assessment is to eliminate risks in a durable way.
Following the risk assessment, the supplier;
a. Identifies already existing risk prevention measures and evaluates residual risk (e.g. PPE
According to the already exists but there is a residual risk of PPE not being used correctly by employees)
risk assessment
2. does the supplier b. Prioritizes risks for which prevention measures are needed based on the risk evaluation
5.14 No NOK
ADVANCE define preventive (exposure and severity) and already existing prevention measures
D measures to
eliminate or reduce c. For prioritized riske identifies control measures to eliminate or reduce the risk long-term (e.g.
the risk? engineering controls, PPE, emergency plans and procedures, training, alarm system, control
center, etc)
Guidance: Convenient means that the work station is setup in an ergonomic way. Ergonomics is
the study of human movement at the work station and when using machinery. The truth of the matter
is ergonomics can have a direct impact on the bottom line. Poor posture, overreaching for tools,
repetitive bending over, too heavy lifting and inadequate lighting, amongst a host of other issues,
Is the workstation can lead to long-term health issues such as back pain, loss of eyesight, workplace stress and
convenient/ergono repetitive strain injury. All of this results in lost time, reduced productivity, poor employee health,
mic for the low morale and higher costs. Therefore it is important for the supplier to consider ergonomic factors
2. in the workplace. An ergonomic workstation facilitates work and maintains good health.As a
5.15 ADVANCE requested type of No NOK minimum1. Risk assessment should identify ergenomic risk and hazards. If there is no inhouse
x
For machines Definition: The system to "lockout and tagout" is displayed in order to ensure no accidental
where lock-out operation of machinery when any maintenance work is being done on the machine.
procedures must be
2. followed, are
5.16 ADVANCE procedures and No NOK
D records available
and known by all
concerned
workers?
Are standard Definition: SOP means Standard Operating Procedure, it is an A4 document posted at the
operating workstation. All step of work should be included in the risk analysis. The SOP should be
procedures (SOP) understandable by all workers, visual and practical. Minimum information on the SOP: Hazards,
properly posted at protective equipment, emergency procedure.
2. risky workstations
5.17 ADVANCE and updated No NOK
x
D regularly based on
the risk analysis?
(Cutting dept,
general storage
area, etc.)
Definition:
Does the supplier
Injury is any injury (including a fatality) which results from a work-related incident or exposure
keep records of
involving a single incident. Examples are:
recordable work
2. • Thermal and chemical burns
related injuries and
ADVANCE illnesses? • Cuts, abrasions and punctures
5.18 No NOK
x
The annual summary of injuries/illnesses must be posted in areas accessible to employees. This
should include:
• Total number of injuries and illnesses events.
• Total number of deaths.
• Total number of days away from work.
• Total number of cases restricted work activity or job transfer.
• Data should be reported to Decathlon yearly. (FACTORIES WITH 10 or FEWER
WORKERS ARE EXEMPT FROM THIS REQUIREMENT)
The OSHA Form 300 provides a template for how to log work related injuries and illnesses
The OSHA Form 301 provides a template for how to record an individual incident of a work related
injury or death, this form should be sent to Decathlon.
The OSHA Form 300A provides a template for an annual injury and illness
report. https://www.osha.gov/recordkeeping/new-osha300form1-1-04-
FormsOnly.pdf
Guidance: All fatalities or serious injuries (e.g. incidents resulting in 24 hour inpatient
hospitalization, permanent disfigurement, loss of any body part or loss of sight, etc.) must be
communicated to a Decathlon representative within 8 hours of incident occurrence.
In case of death or Incident investigation report must be submitted to Decathlon representative within 48 hours. The
hospitalisation, is report must include as a minimum:
2.
there a process to • Name of site location.
5.19 ADVANCE No NOK
ensure that • Specific location and time of the incident.
x
D
Decathlon is • Relevant facts and witness information.
informed • Name and number of fatalities or hospitalized employees.
immediately? • Contact person and phone number.
• Complete description of the incident and all contributing causes.
• Plan for injury management (communication with injured employee, covering of medical
costs, plan for return to work, potential legal management)
• Corrective measures necessary to prevent recurrence.
2. Does the supplier Guidance: Procedure on injury and illness management should define
5.20 ADVANCE have a formal No NOK - Reporting and record requirements (timeframe, who to report to etc.)
x
D procedure - Root cause analysis / incident investigation report + link to risk assessment
regarding root - Process for taking corrective and preventive measures
cause analysis, - Injury/illness management:
corrective and • Incident confidentiality.
preventive actions • What to do in case of severe injuries ((transportation, local hospital arrangements, people
in case of work to contact etc.)
related injury and • Communication with injured employee (e.g. wages, medical restrictions, etc.).
illness? • Return to work provisions (including any work restrictions and transitional work).
Is the procedure • Enforcement of any work restrictions.
communicated and
understood by
people on site
(workers, HR,
security agents, line
managers, etc..)?
Is an annual noise Guidance: If a internal system is used, some information is needed: protocole of measurements,
measurement areas of measurements, number of workers, date, tool calibration, noise level limits, tools
2. record available maintenance
5.21 ADVANCE and done by a third No NOK If done by a third-party, it should be certified third-party with relevant expertise. Protocole of
D party or with measurements, areas of measurements, number of workers, date, tool calibration, noise level limits,
internal tools maintenance should be available.
measurement
system?
Guidance: Supplier sites with identified noise levels above 85 dB should have implemented
procedures to reduce or eliminate the risk of hearing loss which must cover, as a minimum, the
following:
Is the supplier - Evaluate the risk associated with high noise (e.g., hearing loss, concentration, unable to hear
proactively fire alarms) as part of the risk assessment
implementing - Evaluate engineering controls to reduce noise exposure to less than a minimum of 85 dB
measures to reduce - Noise monitoring when there has been a significant change in machinery or production processes.
2. exposure to noise - Signs indicating areas where hearing protection is required.
ADVANCE other than PPE
x
ADVANCE health & safety - Management must respond to all H&S committee recommendations before the next meeting,
D procedures or within 30 days, whichever happens first.
(including chemical - The committee must establish and or approve procedures for investigating all H&S
and fire safety)? Is related incidents including injury
this committee accidents, illnesses, deaths, chemical spills and fires.
comprised of - All HSE committee members must be trained H&S requirements and committee functioning
managers and Handbook for HS Committees
worker
representatives ?
Guidance: Managers, supervisors and line leaders have an important role to play in creating a
Do managers,
health & safety culture in the supplier site and implementing the health & safety system. They
supervisors and
should be trained more in-depth on important HS safety procedures/aspects related to their job
line leaders receive
function/workstation regularily e.g. annually (e.g. chemical manager should get additional training
additional training
2. on chemical safety, training can be on near miss, fire safety, building safety, machine safety
regarding the
ADVANCE supplier's health & depending on job function etc.) and how to implement them in their daily work and with workers.
5.25 No NOK
x
D They should be aware of the facility's emergency response plan and their role in case of an
safety procedures
emergency.
and all health &
They should be aware of how to quickly respond to and correctly report any work-related injury.
safety requirements
They should be aware of the implementation of the fire safety procedure/system and their role in
related to their job
case of emergency (what do they need to do, what is the overall fire safety procedure, which
function?
colleagues are responsible for what)
Are there Guidance: Unless specified otherwise by local law, per shift minimum 2 workers out of 50 should
2. employees trained be trained as first-aid practitioners.
5.26 ADVANCE as first-aid No NOK
D practitioners for
each shift worked?
Guidance: The emergency response plan/plans can cover all kinds of emergencies such as
Does the facility
accidents, fire, building collapse, chemical, social unrest, natural disaster etc.
have a formal
emergency
response plan on Based on the risk assessment, the emergency response plan/plans should cover the following
2. the actions to take aspects:
ADVANCE in case of serious - Identify events that may likely lead to an emergency situation (e.g. fire, building collapse,
5.27 No NOK
x
If required by law, Definition:If there is a clinic of first aid station, all health care staff should be trained in the practice
2. is there an in-house of occupational and emergency medicine and have a certification by a recognized institution. The
5.28 ADVANCE clinic or first aid No NOK clinic should have infection Control and appropriate first aid equipment on hand (e.g. sterile gloves,
D station in the CPR barrier mask, autoclave, disposable needles, and suture kits).
supplier site?
Is there a Definition:The health & safety responsible person based on training and experience can evaluate
responsible health & safety standards in the supplier site and implement strategies to continuously improve these
person/people standards. Typically, this person has been certified/trained by a reputable third party. A reputable
assigned for health third party can be a specialized training provider or consultancy, university, industry organization or
2. & safety government agency.
5.29 ADVANCE management with a No NOK
x
D certified skill level As a minimum, the training/certificate the health & safety responsible person holds should cover
(e.g. external skills related to all health & safety chapter of this grid.
certificate,
university
diploma)?
Does the supplier Definition: Occupational Health and Safety management system certifications include OHSAS
engage a third- 18001, AS/NZS 4801 and ISO 45001, a range of organizations are accredited to certify according to
party to evaluate these standards. Other local OHS certifications may also exist.
3. all aspects of their Not
5.30 EXCELLE Health & Safety Asse NOK
x
plies? during
LEVEL
MANAGE assess Com
ment?
MENT ments
Guidance: All chemicals present in the supplier site should be included in the chemical list:
Is the inventory of manufacturing process, and tooling/ equipment, machine cleaning, office cleaning, laboratory,
all the chemicals degreasing... except office materials unless required by law. A complete chemical inventory
used in the supplier includes: chemical name, chemical supplier's name and contact, Safety Data Sheet (SDS) revision
INFO /
site available date, function, hazard classification, location of use, storage conditions and location, quantities,
6.0 PREPA
(Excluding SDS for CAS number
office materials e.g.
white glue, unless
required by law.) ?
Guidance: Working with chemicals can interfere with the pregnancy, damage the child's
development, health and future fertility. They can also contaminate the breast milk.
Are pregnant or As soon as the worker is aware about her pregnancy the following requirements are mandatory or
breastfeeding according to country law (whichever is higher). For breastfeeding workers, the following
0. workers working at requirements are mandatory until the end of the breastfeeding period:
6.1 UNACCE a workstation using No OK - no work at workstation using hazardous chemicals especially with hazard identification H340,
x
P TABLE hazardous H341, H350, H351, H360, H360F, H360D, H360FD, H360Fd, H360Df, H361, H361f, H361d,
chemicals ? H361fd, H362 (Be careful, no pictogram for H362)
- No work near the area of workshops using hazardous chemicals unless there is evidence of no risk
- Employer must offer pregnant employees another temporary job compatible with their
conditions. This assignment must not lead to a reduction in their remuneration.
In case of use of
Toxic or CMR
chemicals 6.2, 6.3,
6.4 need to be assess
according to the risk
x
DATED management
(Purchasing,
storage, health and
safety) ?
Guidance: SDS of all chemicals present in the supplier site : manufacturing process, and tooling/
Are SDS for ALL equipment, machine cleaning, office cleaning, laboratory, degreasing... except office materials
chemicals available unless required by law. Definition: Understandable for the person/people in charge of chemicals
1. ? Is the language means the chemical manager, storage manager, hazardous waste manager can read and understand
6.6 CONSOLI understandable for Yes OK the content of the SDS
DATED the person/people
in charge of
chemicals ?
Are workers who Guidance: Workers handling chemicals should know the risk when using chemicals and the
are engaged in the equipments and procedure to protect themselves.
handling, usage, A formal training is not asked on question 6.9
1. storage and
6.7 CONSOLI purchasing of Yes OK
x
DATED workstation using contamination by hazardous chemicals. This requirement limits the risk of ingestion of hazardous
hazardous chemicals.
chemicals ?
In case of use of
any hazardous
chemicals 6.9/
6.10/6.11/6.12
need to be assess
according to the
risk analysis and
the SDS. If SDS
are not available,
6.9/ 6.10/6.11/6.12
will be assessed as
not ok.
Are ALL chemical Guidance: At reception all chemicals are identified (name + supplier name). The hazardous ones
containers and sub- have hazards pictograms consistent with the Safety Data Sheet.
1. containers/chemical Chemical label means a clear identification of the hazard of the chemicals, name and pictograms
CONSOLI transfer containers Yes OK should be present on all chemical containers and sub-containers in the supplier site.
6.9
DATED identified by
labelling (name +
hazard
pictograms)?
Are PPE Definition:PPE means Personal protective equipment: Masks, gloves, goggles, protective clothes.
appropriate to the Appropriate to the risk and efficient means that the PPE is selected according to the chemical(s) used
risk, efficient, in at the workstation. In good working order means gloves are not damaged, mask is clean and the
good working order cartridge have opening date. The overall is clean (regularly washed) and liquid proof.
and stored in tidy
1. condition ? A periodical chemical exposure diagnosis for the concerned workstation(s) means that supplier
6.10 CONSOLI
Yes OK
should provide proof and evidence that there is no risk for workers exposed to hazardous chemicals.
DATED If not, supplier must Supplier needs to evaluate the exposure and can ask external expert.
provide a periodical
chemical exposure Guidance: PPE are stored in tidy condition means there is a dedicated area to store the PPE. PPE
diagnosis for the should be stored in visible closet or box, easy to access and ready to use. PPE are stored in a dry
concerned place, away from light, dust, chemicals and extreme temperature. Mask are stored in a sealed bag.
workstation(s).
Are workstations Definition: A periodical chemical exposure diagnosis for the concerned workstation(s) means that
equipped with supplier should provide proof and evidence that there is no risk for workers exposed to hazardous
efficient collective chemicals. Supplier needs to evaluate the exposure and can ask external expert.
protection system,
e.g. ventilation / Guidance: Collective equipments are used to reduce the exposure of workers to hazardous
isolation / chemicals.
exhaustion ? Efficient collective equipment means that the system is the most adapted to the workstation and
(Fan and natural follows the basic rules below:
6.11 1. air ventilation are - As close as possible to the emission source
CONSOLI not efficient Yes OK - Follow the airflow of the emission
DATED engineering - Power is enough to decrease significantly the amount of chemicals in the air: air flow at 0.5 - 2.5
equipment) m/s (anemometer)
- The emission source should be surrounded
If not, supplier must - Do not disturb the worker and train him on how to use collective equipments.
provide a periodical
chemical exposure
diagnosis for the
concerned
workstation(s).
Definition: Efficient emergency PPE and equipment means accessible to the worker in case of
accident within less than 1 minute. Appropriate extinguisher means adapted ones, especially for the
Are workstations chemical area, the type of extinguisher depends on the chemicals stored, you should select the good
and chemical ones (Water, CO...)
storage areas close
1. to efficient Guidance: In the chemical storage area, emergency PPE are outside the storage area at the front
6.12 CONSOLI emergency PPE door.
Yes OK
DATED and equipments Emergency PPE and emergency equipments should be easily accessible < 1 min away), maintained
(e.g.:eye wash and stored in tidy condition
station, Stair, doors should not block the way to the emergency equipments.
shower.,spillage kit,
appropriate fire - check if eye washers are in good working condition => test the pressure to wash two eyes
extinguishers...)? (water jet height between 5cm <-> 20cm), should contain enough water to clean the eye during
15 min.
- check the shower => water is clean and water pressure/quantity is sufficient to cover all the
body of the victim during at least 15 min (Should contain enough water).
- check the nearest 1st aid box (unlocked with emergency PPE)
- spillage kit
Guidance: Secondary containers are necessary when using hazardous liquid chemicals for several
Are there adapted reason:
equipments to - Avoid cross contamination in case of leakage of chemicals
ensure that there is - Avoid contamination of the environment
no leakage of - Avoid leakage in the floor
1. hazardous liquid
6.13 CONSOLI chemicals in
Yes OK
Secondary containment materials should be impervious and adapted to chemical stored
DATED storage and Incompatible chemicals should have their own secondary containment.
production areas Volume of secondary containment must be adapted to the volume of chemicals stored, you can use
eg.secondary the secondary containment tools to help you with the calculation.
containers,
retention tanks ? Retention tanks are accepted only if not compatible chemicals are not stored together, please refer to
the section 7 and 10 of the SDS.
For hazardous Definition: Access limited means only people trained and authorised are allowed to enter into the
chemicals storage area, there is a system to block or control the access to the storage area.
area (new and Well-ventilated means the air inside the storage area should be renewed at least 4 to 6 times per hour
already in use), is with a mechanical ventilation.
the access limited, Relevant information means that SDS or any documents with detail explanation about the chemical
temperature (Hazard, condition of storage...) should be present in the chemical storage.
monitored, in a
separated area and Guidance: Temperature is monitored: High temperature increases the release of hazardous and
6.14 1. good ventilation volatile chemicals in the air. This increases the risk for workers working in the chemical storage and
CONSOLI ensured eg: Yes OK
the risk of explosion.
DATED mechanical
ventilation, in
accordance with
SDS? Is relevant
information about
the chemicals
available in the
storage area ?
Are flammable, Guidance: Incompatible chemicals should not be stored in the same area (Please check the storage
explosive, corrosive recommendation on SDS).
and oxidiser The separation of hazardous chemicals should be done according to the compatibility chart.
chemicals stored Incompatible chemicals are chemicals that require different extinguishing agents, different
separately and temperature conditions or in case of mixing will interact together. Some chemicals can react with
1. securely? Are each other, sometimes causing explosions, fires, splashes or emissions of dangerous gases. These
6.15 Yes OK
CONSOLI incompatible incompatible products must be physically separated.
DATED chemicals Flammable, explosive, corrosive and oxidiser should be physically separated in a dedicated and
physically constantly ventilated enclosure.
separated Some other products react violently with water: they should be stored in such a way that contact
according to the with water is impossible, even in the event of a flood.
SDS ?
Are containers Definition: Appropriate container means exposure of workers is limited from production line to
closed and waste storage : size of containers is adapted to a shift use, automatic dispensers are used or
appropriate from containers are closed when not in use.
storage to the Transportation tools means any devices that transport chemicals drum/containers safely such as
1. production line barrel transport trolley, transportation-tank in order to decrease the risk of drop, leakage and
6.16 CONSOLI until the waste Yes OK
accident.
DATED storage? Are
adequate
transportation tools
used to transport
chemical products
to the workstation?
Is the inventory of Guidance: All chemicals present in the supplier site should be included in the chemical list:
all chemicals manufacturing process, and tooling/ equipment, machine cleaning, office cleaning, laboratory,
complete and degreasing... except office materials unless required by law. A complete chemical inventory
updated? (At least includes: chemical name, chemical supplier's name and contact, Safety Data Sheet (SDS) revision
chemical name, date, function, hazard classification, location of use, storage conditions and location, quantities, CAS
chemical supplier's numberFor textile components suppliers only: Please use the BHive tool to create your inventory
name and contact, and scan all your chemical products. The % of conformity should be communicated to Decathlon's
2. Safety Data Sheet team.https://www.thebhive.net/
6.17 ADVANCE (SDS) revision date, Yes OK
D function, hazard
classification,
location of use,
storage conditions
and location,
quantities, CAS
number)
Guidance: SDS of all chemicals present in the supplier site: manufacturing process, and tooling/
Are SDS of all equipment, machine cleaning, office cleaning, laboratory, degreasing... except office materials
chemicals used in unless required by law.
the supplier site
complete and A SDS should be up to date, revision date <3 year old and include 16 chapters.
2. updated (<3 years)? Not NOK At minimum, information included:
6.18
ADVANCE (Chemical products Asse - Chemical supplier contact details
D name, contact, ssed - Hazard of the mixture, pictogram + Hazard statement (Phrase H)
pictograms, hazard - Composition of the mixture and hazard linked by substance (CAS Number/Hazards/Concentration)
statement, - Handling and storage recommendations
composition...)
A procedure to check to collecte and review SDS is set-up.
Is there a Guidance: The procedure should contain information about the person in charge of PPE purchase,
2. procedure for Not PPE suppliers and contact, distribution, maintenance of PPE, replacement frequency, sign of
6.19 ADVANCE chemical PPE Asse NOK impaired such as a hole in gloves, a broken mask.. , storage, register of each workers with assigned
D management ? Is it ssed PPE.
applied ?
Is there a Guidance: The procedure should contain information such as :
procedure for Parameter to control (Air flow, filters, alarm system...)
collective protective Date and result of the last control
2. equipments Not Control frequency
6.20 ADVANCE (ventilation system, Asse NOK
D control ssed
engineering,
shower, air flow, ...)
management ? Is it
applied ?
Is the occupational Guidance: The supplier must evaluate and measure the occupational exposure to chemicals
exposure of considering all exposure pathways (respiratory tract, dermal route, digestive tract and bloodstream in
workers to case of open wound).
chemicals
measured ? Is there Internal air quality control is part of the evaluation of the risk of exposure of workers to chemicals.
a control of the The supplier should provide an annual test report from an external laboratory or based on internal
2. Not
internal air quality method about the quality of the air in the workstation using chemicals.
6.21 ADVANCE Asse NOK
which is compliant If not controlled by local regulation please refer to section 8 (exposure control) of the SDS
D ssed
with local This test report should contain: Risk analysis of chemicals used in the supplier site, protocol
regulation or/and of measurement, result and conclusion.
the relevant
chemical exposure Attention: Check if all volatile chemicals used in the supplier site are listed in the report.
limits defined in
SDS?
Guidance:
Even if all precautions to limit the exposure of workers to chemicals are taken, it is necessary to set
For all workers up an individual medical monitoring. Medical exam linked to chemical risks means a medical
working with monitoring (clinical and biological) for early detection of health effects regarding chemicals
hazardous exposure.
chemicals, is a This follow-up is done by a healthcare practitioner after a deep analysis of workstations and
medical exam professional risks. Health of the workers is checked by blood or urine tests on the relevant
conducted which substances.
2. Not Medical checks should be done at a frequency defined by the occupational doctor and in line with
6.22 evaluates potential
ADVANCE Asse NOK the risk related to the activity.The first visit should be done within 3 months after taking the new
health damage due
D ssed position and the time between 2 visit should not exceed 5 years. Unless otherwise specified,
to chemical
exposure? Are workers working with CMR agents are subject to a strengthened follow-up of their state of health,
actions taken for an annual checkup is recommended.
those employees
whose health is Action taken should be decided in accordance with the occupational doctor recommendations
impacted? (communication with injured employee, covering of medical costs, plan for return to work, potential
legal management, possible reassignment, no more work with chemicals, corrective measures
necessary to prevent recurrence)
Are there SOPs Definition: SOP means (Standard operating procedure), it is a A4 document posted at the
(standard workstation .There is only one SOP per workstation even if using several chemicals. All chemicals
operating should be included in the risk analysis for all steps of work. Should be understandable by all
procedures) that workers, visual and practical. The SOP should contain at least : Approved chemical risk, chemical
cover chemical classification, steps of work, safe chemical handling, chemical disposal...
management (Such
as an approved
2. chemical risk, Not
6.23 ADVANCE chemical Asse NOK
D classification, steps ssed
of work, safe
chemical handling,
chemical disposal...)
posted near the
place of use of the
chemicals ?
Does the supplier Guidance: An emergency procedure has to be written everywhere a chemical risk is identified.
have an emergency It should contain as a minimum:
procedure for What to do in the event of a chemical accident, the alarm and alert systems or other communication
2. chemical accidents? Not systems to be used, the people to contact (outside help, occupational doctor, occupational nurses,
6.24 ADVANCE Does the supplier Asse NOK first aid managers, line managers),
D keep records of all ssed the rules for limiting the access or evacuation of personnel to be applied in case of accident and the
employee incidents first aid and personal protective equipment to be used
related to chemicals
?
Are regular Guidance: Same as fire safety drills, emergency exercises are performed to simulate chemical
emergency accidents in order to test and ensure that procedures are known, applied and work well.
exercises
performed to
2. ensure that Not
ADVANCE workers know how Asse NOK
6.25
x
D to manage a ssed
chemical incident
(simulation of
people fainting,
spillage procedure
etc) ?
Does the supplier Guidance: When validating a new chemical, the supplier should use this opportunity to minimise
site use a procedure the chemical risk to employees from the moment of chemical selection by considering the SDS
to validate quality, hazard statement, condition of use...
2. chemicals to be The parameters to evaluate and rank chemical products should be defined such as hazard
6.26 ADVANCE purchased and No NOK classification, volume per year, SDS quality, chemical supplier level...
x
D rank chemicals
used in the supplier You can use Decathlon's risk evaluation file, procedure or any other tools to do the ranking of
site against their chemicals
health impact(s)? Chemical assessment tool
Are the responsible Guidance: The chemical safety manager based on training and experience has the necessary
person/people knowledge to evaluate chemical safety standards in the supplier site and implement strategies to
assigned for continously improve these standards. Typically, this person has been certified/trained on chemical
2. chemical safety Not safety topics.
6.27 ADVANCE management with a Asse NOK
x
D certified skill level ssed As a minimum, the training/certificate the health & safety responsible person holds should cover
(e.g. external skills realted to all chemicals management chapter of this grid.
certificate,
university
diploma)?
Are training Guidance: Training minimizes the risk of accidents linked to chemicals, all relevant workers should
records maintained be trained on minimum knowledge regarding chemical management.
to demonstrate that Training records should be kept for all trained employees with the name and the date of the last
2. facility personnel Not training.
ADVANCE handling chemicals Asse NOK A formal training is asked in question 6.28
6.28
x
D have training and ssed The training should include at minimum know-how on hazards and risks linked to the use of
skills to perform chemicals, purchasing requirements, how to use PPE, how to use collective protection, SDS, storage
their assigned of chemicals, SOP, Emergency Procedure, chemicals disposal.
responsibilities and
activities?
Does the supplier Guidance: The hazardous chemical reduction plan should focus on continous improvement to
have a hazardous reduce the risk linked to chemicals and :
chemical reduction a. Be developed taking into consideration high risks (per risk assessment), legal and other
plan with clearly requirements, technological options, financial, operational, and business requirements, and views
3. set targets? Does of stakeholders.
6.29 EXCELLE the supplier have a Yes OK b. Include SMART (Specific, measurable, achievable, realistic and time bound) objectives.
x
EXCELLE
NCE communicated by
the chemical
suppliers ?
3. proposal for inspiration
Does the chemical
EXCELLE
x
storage contains:
NCE
Definition:
3.
6.31 The storage plan is a clear and visual plan of the storage area. It is possible to identify the chemicals
EXCELLE > Storage plan Yes OK
x
stored in the area , know the quantity or volume of chemicals stored and visualize the emergency
NCE
responses.
Definition:
An explosimeter is a gas detector which is used to measure the amount of the volume of flammable
gas in a gas/air mixture present in a sample. When the lower explosive limit (LEL) of an atmosphere
is exceeded, or or upper explosive limit (UEL) is not exceed, an alarm signal on the instrument is
3. activated.
6.32 EXCELLE > An explosimeter Yes OK Explosive limits specify the concentration range of a material in air which will burn or explode in
x
NCE the presence of an ignition source. There are two types of explosive limits: lower explosive limit
(LEL) and upper explosive limit (UEL)
It is a very useful tool in the chemical storage to check the safety of potentially explosive areas and
prevent risk of explosion.
Guidance :
3. Temperature is monitored and controlled at a fixed temperature: High temperature increases the
> Temperature
6.33 EXCELLE Yes OK
x
control release of hazardous and volatile chemicals in the air. This increases the risk for workers working in
NCE the chemical storage and the risk of explosion.
3. > Whenever Guidance: Minimize human handling
6.34 EXCELLE possible, automated Yes OK
x
NCE changed ? Is work (Once contaminated, they must be disposed of as waste chemicals).
clothes cleaning Wash hands before each break.
managed by the If necessary, take a shower at the end of the shift.
supplier site ?
3.
Other Best Practice
6.37 EXCELLE Yes OK
carried out:
NCE
Com
LEVEL
SAFETY / during ments
EVACUAT assess
ment?
ION
Is the supplier site
located in a shared
INFO / building?
7.0 PREPA If so, what are the
other activities of
each floor?
Precise for each
floor the number of
people + number of
INFO /
7.0 exits needed
PREPA (according to law)
and what is currently
existing:
Describe the alarm
INFO /
7.0 system and how it is
PREPA
working:
Do all the buidlings Guidance: All the buidlings at the supplier site are connected to a centrale fire drill system. In case
0. covered by the of a fire drill in one building, there is a central system to alert other buildings.
7.1 UNACCEP assessment scope Yes OK
TABLE have a fire alarm
system?
Is the fire alarm Guidance: System must be operational at all times except when testing or undergoing repairs or
0.
7.2 working when Yes OK maintenance.
UNACCEP
tested? (Tested
TABLE
during audit)
Is the fire alarm Guidance: Notification/alarm that is perceivable above ambient noise and light levels.
audible/visible/conn
0.
7.3 ected in all areas of Yes OK
UNACCEP
the premises
TABLE
covered by the
audit scope?
In case of a shared Definition: Shared building means under the same roof
building, is the
alarm system
0.
7.4 audible for both Yes OK
UNACCEP
sides (other
TABLE
suppliers and
Decathlon
factories)?
Is the sound of the Definition: Different means that is distinctive and recognizable
0.
7.5 fire alarm different Yes OK
UNACCEP
to the other existing
TABLE
signals in the
supplier site (e.g.:
the end of shift or
break alarms)?
Does the fire alarm Definition: Back up system means battery or independent power supply.
have an automatic
back-up system
0.
7.6 when the main Yes OK
UNACCEP
power is off?
TABLE
(Tested during
audit - no ringing
shortage)
Can the alarm ring Guidance: Maximum expected time of the evacuation is 5 min.
as long as the time
0.
7.7 of evacuation Yes OK
UNACCEP
whatever the power
TABLE
source? (Main
power or back up)
Are there various
0. manual call points
7.8 UNACCEP throughout the Yes OK
TABLE supplier site as
required by law?
Do workers know Guidance: Any employee should be able to indicate the nearest manual call point from his/her
0.
7.9 where the manual Yes OK workstation and know how to use it.
UNACCEP
call points are and
TABLE
how to use them?
0. Are only validated Guidance: There is an assigned person who is trained and responsible to turn off the alarm after the
7.10 UNACCEP people able to turn Yes OK evacuation is validated complete.
TABLE off the alarm?
Whatever the
regulation, are
there minimum 2
accessible
emergency exits
(minimum 5 meters
between 2 exits)
0. for:
7.11 UNACCEP - all production Yes OK
TABLE areas (including
warehouses)
- any non
production areas
where it happens
that 20 people are
present at the same
time?
Are the emergency Guidance: Emergency exits are unlocked during regular working hours and opening outwards to a
exit doors/fire place of safety. In case of mechanical or electronic door, a simple manual system should allow any
evacuation lines in person to evacuate.
0. good working order
7.12 UNACCE and never locked Yes OK
P TABLE during working
hours (this includes
night time, lunch
time…)?
Is there at least one Guidance: Assembly area should not be:
assembly area - near an external stock of hazardous chemicals, wastes.
which is known by - in the middle of the road
0. the employees? Is it - near an explosive equipment
UNACCE safe, at a minimum Assembly area should not prevent emergency vehicles to access the supplier site.
7.13 Yes OK
P TABLE of 10 meters away
from any building
and can it
accommodate all
the workers?
Is the time of Guidance: Until the last person left the building means all persons present in the supplier site
evacuation drill less including visitor/ external parties/ contractors/sub-contractors. This confirmation should come from
than 5 minutes the evacuation leader at the assembly area.
0. (starting from the Definition: Evacuation leader (or team) are assigned and trained persons from the supplier staff, in
UNACCE call point being charge to organize and drive efficiently the evacuation. One of their tasks it to check that
7.14 Yes OK
P TABLE pushed until the buildings are empty and people are gathering at the assembly area.
evacuation leader
has confirmed
there is no one left
in the building)?
During the Guidance: The supplier should engage a procedure of counting as soon as the employees reach the
evacuation drill, assembly area. To complete the counting, the supplier should compare it with an updated presence
0. does the supplier list of the day of the evacuation. As an example, an efficient counting procedure could include
7.15 UNACCE count all people at Yes OK assigning a responsible person for counting per zone, which reports to evacuation leader if all
x
P TABLE the assembly area employees allocated to his/her zone have reached the assembly area.
including external
visitors & sub-
contractors?
If the building has Guidance:If the buildings has 3 or more floors (included ground floor);
3 or more floors The emergency exit doors has to be fire proof door and should be leading to the exit.
(included ground Fire proof doors should be fireproof certified with an auto-closing system during fire drill.
1. floor): Definition: An external staircase is suitable for fire escape only if it's construction is strong enough
CONSOLI Are emergency to support the cumulated weight and the vibrations caused by the total number of people
7.16 Yes OK
DATED evacuation internal concerned in the floor(s). The staircase should provide sufficient width and guardrail(s) for people
stairs protected to use it safely.
from smoke (i.e.:
are they enclosed
by fire proof doors
at each floor that
are auto-closed
during evacuation?
or are there
external stairs for
emergency
evacuation?)
Does the supplier Guidance: During fire drill the supplier should include the external visitors in their emergency
make external procedure. Visitors should be included in the headcounting during an evacutation.
visitors aware of its
1. fire emergency
7.17 CONSOLI procedure/protocol Yes OK
x
Are emergency Definition: Flammable means a material that catches fire immediately on exposure to flame (textile
evacuation fabrics, cardboxes, paper, flammable and explosive chemicals...)
stairways leading
1. through a
7.19 CONSOLI flammable No OK
DATED materials area (or
flammable
materials stored
under stairways)?
Are the emergency
exits doors clearly
identified, free
from obstacles,
1. easy to operate,
7.20 CONSOLI open out in the Yes OK
Guidance:EMERGENCY EXIT GATES:
DATED direction of
- Exit signage should be available and illuminated on the top of the exit gate or not.
evacuation, with no
- There should be nothing in front of the exit gates , the exit gate, easy to open to outwards
special effort and at
(towards the way of out)
least 80 cm in
- The width of the exit gate should be min 80 cm to easily to pass.
width?
1. Are the premises Guidance: Suppliers shall provide emergency lighting with backup power along the emergency exit
7.21 CONSOLI equipped with Yes OK pathway and shall maintain emergency lighting.
DATED efficient emergency
safety lighting in all
buildings and
stairways?
Are safety Definition: Appropriate extinguishers means adapted ones (Water, CO...), depends on the type of
equipment (fire fire (electrical, paper/wood, flammable liquid, gas, chemicals, metal). Feel free to refer to some of
hose station, those guideline 1- 2 to help you find the one stated by your local law.
extinguishers, etc.)
present,
appropriate, highly
1.
visible, accessible,
7.22 CONSOLI Yes OK
in good working,
DATED
and in sufficient
numbers (as stated
by local law or
following the
recommendation of
1 per 200 m²)?
Is a fire drill Guidance: The purpose of fire drills in buildings is to ensure that everyone knows how to exit safely
1. conducted at least as quickly as possible if a fire, smoke, carbon monoxide or other emergency occurs and to
7.23 CONSOLI once per year (all Yes OK familiarize building occupants with the sound of the fire alarm.[Fire drill should performed by all
DATED shifts, all employees (Day shift and night shift). The record has available which is mentioned drill date & time
personnel)? Are & picture & employees name with their signature at that drill.
records available?
Are possible causes
of fire prevented in
the supplier site?
1. (e.g.: no cigarettes
7.24 CONSOLI or matches in the Yes OK Definition: possible causes of fire mean no operation which is creating fire spark and this spark is
DATED chemical storage moving towards an electric panel board or easy flammable materials including chemicals.
area / no sparks Guidance: it should be internal rules which is forbidden to smoke cigarette in the toilet or
near electrical anywhere. There is specific fire permit before performing some maintenance with "hotspot" (eg :
appliances...) welding)
Are the premises
equipped with a
2. fire detection
7.25 ADVANCE system in No NOK
D accordance with
the risk analysis
and local
regulations?
Is there an updated
evacuation map
2. (different maps if
7.26 ADVANCE there are several No NOK
D levels or buildings)
visibly posted in all
buildings and
showing ''where
you are ''?
Is a basic fire safety Guidance: All employees must receive fire safety training upon initial hire and at least annually
training given upon thereafter. Training must include as a minimum:
2. initial hire • Fire hazards.
7.27 ADVANCE (induction No NOK • Evacuation procedure, emergency routes and exits.
D program) and at • Roles and responsibilities.
least annually
thereafter?
Guidance: A documented procedure is a written description of prescribed course of action or
Is there a fire safety process to manage and control organisations activities. At the minimum the fire safety procedure
procedure covering should clearly define actions and roles and responsibilities on the following
at least fire 1. Measures for fire prevention (e.g. storage of flammable substances in an approved
2. prevention and cabinet, ensuring electrical equipment is maintained in a safe and good working condition
7.28 ADVANCE protection No NOK etc.)
x
D measures? Is the 2. Measures for fire protection (e.g. appropriate fire detectors and alarm systems in place, use
procedure of sprinkler systems, firefighting equipment appropriate for type of fire expected etc.)
implemented on- 3. Measures for fire precaution (e.g. sufficient number of emergency routes and exits indicated
site? by signs, posted diagrams showing emergency routes and exits)
4. The Fire Procedure can also include the Fire Emergency Response Plan. This is already
covered in question 5.27.
Per shift, are
minimum 2
workers out of 50
trained (or
following local law,
whichever
requirement is
2. higher) on the
7.29 ADVANCE implementation of No NOK
D the fire safety
procedure/system
and their role in
case of emergency?
(e.g. organize
evacuation, check
building is empty
etc.)
Are fire safety Guidance: As a good practice fire and safety equipments should be numbered to allow easy
equipments (alarm, mainteanance follow up. Equipment should be maintained monthly and must be maintained at least
backup battery, annually or in line with local regulation (whichever is higher). If the supplier cannot guarantee good
2. emergency lighting, maintenance internally for equipment, and external company should be used.
7.30 ADVANCE fire hose station, No NOK
D extinguishers, etc.)
regularly
maintained and
checked at least
once a year or
according to the
local regulation
(precise the
frequency)?
Is the supplier site Guidance: If based on the findings of the risk assessment a sprinkler system is not needed or only
2. equipped with a required for specific factory areas (e.g. warehouse), this question is either not applicable (first case)
7.31 ADVANCE sprinkler system in No NOK or ok (second case). A sprinkler system is mainly recommended for areas of high fire risk such as
x
during
LEVEL ENVIRON plies?
assess Com
MENT ment? ments
Temp
REQUIRE 9- orally
C ### solved GUIDANCE & DEFINITIONS
MENT WORKING Com
x