3-Pile Cap-Eurocode
3-Pile Cap-Eurocode
3-Pile Cap-Eurocode
PILE REACTIONS kN
PILE 1 PILE 2 PILE 3 OVERTURNING MOMENTS - kNm characteristic
Gk + Qk 141.0 169.4 192.5 . DEAD IMPOSED WIND
Gk + Qk +Wk 139.9 173.4 199.6 Mx 10.0 5.0 2.0
1.35Gk + 1.5Qk 194.9 234.7 267.0 My 20.0 10.0 5.0
1.0Gk + 1.5Wk 108.8 135.4 155.4 .
1.35Gk + 1.5Qk + 0.75Wk 193.8 238.7 274.1 .