BOSTRIG™ TYPE P SIGNAL CABLE 600V

Overall shielded multiconductor / armored and sheathed


TYPE P SIGNAL CABLE 600V, 20, 18 & 16 AWG

Applications Approvals
Bostrig™ Type P Marine and Offshore Cable is primarily IEEE 1580 and IEEE 45- Marine Shipboard Cable
designed for power, control, signal, and instrumentation
UL 1309- Marine Shipboard Cable Type X110
applications for offshore and land drilling rigs, marine
vessels, and offshore production facilities. CSA 22.2 No. 245- Marine Shipboard Cable Type X110
Det Norske Veritas (DNV)
Bostrig™ cables have excellent resistance to oil, abrasion,
moisture, vibration, sunlight, and ester based mud American Bureau of Shipping (ABS)
(Type P- MR). They are suitable for use in Class 1, Transport Canada Approved AMS400-20-2
Division 1 offshore applications (armored & sheathed).
Transport Canada 8700-20-2
The standard insulation has a continuous operating Lloyd’s Register of Shipping (LRS)
temperature of 125°C, allowing for higher ampacity levels.
United States Coast Guard-46CFR
These cables also meet cold bend requirements of -40°C
and cold impact of -35°C (CSA 22.2 N0. 0.3).
Construction
This product may be manufactured in an unarmored
or armored and sheathed version. CONDUCTORS: Soft annealed stranded tinned copper
per ASTM B 33. A polyester tape separator is used over
the conductor.
Features/Ratings
INSULATION: Bostrig Type P chemically cross-linked
- Superior resistance to oil, abrasion, moisture,
polyolefin (XLPO), meeting IEEE 1580.
sunlight, crush and impact
- High strand count conductors provide superior SHIELD: An aluminum/polyester tape with drain wire,
flexibility 100% coverage, is applied over the cabled core.
- Higher allowable conductor operating temperature JACKET: Flame-Retardant Thermosetting CPE (Chlorinated
results in increased ampacity Polyethylene) in accordance with the requirements of IEEE-
1580-2010. Thickness as shown in tables on opposite page
- Cold bend/ cold impact of -40°/ -35°C in accordance
with CSA 22.2 No. 0.3 Arctic Neoprene (Type N) also available as an option.

- Flame retardant in accordance with IEEE 1202 and ARMOR: Braided bronze in accordance with IEEE 1580.
IEC 60332-3-22 Category A
SHEATH: Flame-Retardant Thermosetting CPE (Chlorinated
- Meets IEEE standards for 600V and performance Polyethylene) applied over the armor in accordance with
requirements of IEC standards for 0.6/1 kV the requirements of IEEE-1580-2010. Thickness as shown
- Armored and sheathed cables suitable for use in in tables on opposite page. Arctic Neoprene (Type N) also
Class 1 Division 1 and Zone 1 hazardous locations available as an option.
offshore

Draka Marine, Oil & Gas


+1 281-209-1070 / +1 888-354-CABL (2225)
website: na.prysmiangroup.com/oil-gas
BOSTRIG™ TYPE P SIGNAL CABLE 600V
Overall shielded multiconductor / armored and sheathed
TYPE P SIGNAL CABLE 600V, 20, 18 & 16 AWG

20 AWG • 0.61 mm2


Type Draka Number of Insulation Sheath Cable Diameter Cable Weight
Designation Number Conductors Stranding Thickness Thickness (nominal) (approximate)

in mm in mm in mm Lbs/Mft Kg/Km

C(0S)20PNBS-3 T26503 3 19/32 .030 0.76 0.060 1.5 0.530 13.5 185 275

C(0S)20PNBS-4 T26504 4 19/32 .030 0.76 0.060 1.5 0.560 14.2 210 315

C(0S)20PNBS-5 T26505 5 19/32 .030 0.76 0.060 1.5 0.590 15.0 230 340

C(0S)20PNBS-6 T26506 6 19/32 .030 0.76 0.060 1.5 0.610 15.5 255 380

18 AWG • 0.96 mm2


Type Draka Number of Insulation Sheath Cable Diameter Cable Weight
Designation Number Conductors Stranding Thickness Thickness (nominal) (approximate)

in mm in mm in mm Lbs/Mft Kg/Km

C(0S)18PNBS-3 T26507 3 19/30 .030 0.76 0.060 1.5 0.540 13.7 205 305

C(0S)18PNBS-4 T26508 4 19/30 .030 0.76 0.060 1.5 0.570 14.5 230 340

C(0S)18PNBS-5 T26509 5 19/30 .030 0.76 0.060 1.5 0.620 15.7 260 385

C(0S)18PNBS-6 T26510 6 19/30 .030 0.76 0.060 1.5 0.630 16.0 286 425

C(0S)18PNBS-25 ------ 25 19/30 .030 0.76 0.080 2.0 1.110 28.2 705 1050

16 AWG • 1.23 mm2


Type Draka Number of Insulation Sheath Cable Diameter Cable Weight
Designation Number Conductors Stranding Thickness Thickness (nominal) (approximate)

in mm in mm in mm Lbs/Mft Kg/Km

C(0S)16PNBS-3 T26511 3 19/29 .030 0.76 0.060 1.5 0.570 14.5 220 325

C(0S)16PNBS-4 T26512 4 19/29 .030 0.76 0.060 1.5 0.600 15.2 255 380

C(0S)16PNBS-5 T26513 5 19/29 .030 0.76 0.060 1.5 0.640 16.3 285 425

C(0S)16PNBS-6 T26514 6 19/29 .030 0.76 0.060 1.5 0.670 17.0 315 470

C(0S)16PNBS-12 ------ 12 19/29 .030 0.76 0.060 1.5 0.820 20.8 470 700

This information is provided for reference only. Please consult the factory or your representative to confirm all engineering information.
This information is not intended to replace the information in the appropriate and applicable standard or code.

Draka Marine, Oil & Gas


+1 281-209-1070 / +1 888-354-CABL (2225)
website: na.prysmiangroup.com/oil-gas
BOSTRIG™ TYPE P SIGNAL CABLE 600V
Overall shielded multiconductor / armored and sheathed
TYPE P SIGNAL CABLE 600V, 20, 18 & 16 AWG

20 AWG • 0.61 mm2


GLAND SELECTION GLAND REFERENCE CHART
Explosion Proof: Non-Explosion Proof:
Type Draka Cable Diameter Explosion Proof: Non-Explosion Proof: Non-Explosion (Armored) (Armored) - NPT Thread
Designation Number (nominal) Armored Armored Proof: Armored Hub Size Reference Size Reference
in mm (metric) (NPT)
C(0S)20PNBS-3 T26503 0.530 13.5 424AN-02/ 10 474SW-52 474NP-04/ 07 01 = 1/2" 03 = 1/2" - 14 NPT
C(0S)20PNBS-4 T26504 0.560 14.2 424AN-02/ 10 474SW-52 474NP-04/ 07 02 = 3/4" 04 = 1/2" - 14 NPT
C(0S)20PNBS-5 T26505 0.590 15.0 424AN-02/ 10 474SW-53 474NP-05/ 08 03 = 1" 07 = 3/4" - 14 NPT
C(0S)20PNBS-6 T26506 0.610 15.5 424AN-02/ 10 474SW-53 474NP-05/ 08 04 = 1-1/4" 05 = 1/2" - 14 NPT
05 = 1-1/2" 08 = 3/4" - 14 NPT
06 = 2" 10 = 3/4" - 14 NPT
18 AWG • 0.96 mm2
07 = 2-1/2" 14 = 1" - 11-1/2 NPT
GLAND SELECTION 08 = 3" 15 = 1" - 11-1/2 NPT
09 = 3-1/2" 20 = 1-1/4" - 11-1/2 NPT
Type Draka Cable Diameter Explosion Proof: Non-Explosion Proof: Non-Explosion 10 = 1/2" 21 = 1-1/4" - 11-1/2 NPT
Designation Number (nominal) Armored Armored Proof: Armored
12 = 3/4" 27 = 1-1/2" - 11-1/2 NPT
in mm (metric) (NPT)
15 = 1" 28 = 1-1/2" - 11-1/2 NPT
C(0S)18PNBS-3 T26507 0.540 13.7 424AN-02/ 10 474SW-52 474NP-04/ 07
31 = 2" - 11-1/2 NPT
C(0S)18PNBS-4 T26508 0.570 14.5 424AN-02/ 10 474SW-52 474NP-04/ 07
32 = 2" - 11-1/2 NPT
C(0S)18PNBS-5 T26509 0.620 15.7 424AN-02/ 10 474SW-53 474NP-05/ 08
33 = 2" - 11-1/2 NPT
C(0S)18PNBS-6 T26510 0.630 16.0 424AN-02/ 10 474SW-53 474NP-05/ 08
38 = 2-1/2" - 8 NPT
39 = 2-1/2" - 8 NPT
16 AWG • 1.23 mm2 45 = 3" - 8 NPT

GLAND SELECTION 47 = 3" - 8 NPT

Type Draka Cable Diameter Explosion Proof: Non-Explosion Non-Explosion


Designation Number (nominal) Armored Proof: Proof: Armored
Armored
in mm (metric) (NPT)
C(0S)16PNBS-3 T26511 0.570 14.5 424AN-02/ 10 474SW-52 474NP-04/ 07
C(0S)16PNBS-4 T26512 0.600 15.2 424AN-02/ 10 474SW-53 474NP-05/ 08
C(0S)16PNBS-5 T26513 0.640 16.3 424AN-02/ 10 474SW-53 474NP-05/ 08
C(0S)16PNBS-6 T26514 0.670 17.0 424AN-02/ 10 474SW-53 474NP-05/ 08