Organization Name:
Project Name:
Contents
A. Foundation Materials ........................................................................................................ 2
B. Masonry ............................................................................................................................... 2
C. Tools and Fasteners ........................................................................................................... 2
D. Metal Items.......................................................................................................................... 3
E. Carpentry and Furniture................................................................................................... 3
F. Thermal Moisture Protection ........................................................................................... 3
G. Doors and Windows (excluding locks) .......................................................................... 4
H. Finishes ................................................................................................................................ 4
I. Plumbing and Mechanical Systems ................................................................................ 4
J. Electrical Items ................................................................................................................... 5
K. Other Miscellaneous .......................................................................................................... 5
All items listed as “inspectable” may be procured locally using allotted random
procurement percentages. All items that are “non-inspectable” must be procured in the
US and securely shipped to the construction site.
Page 1 of 5
A. Foundation Materials
* Note:
1. Aggregate cement, sand and gravel should be poured through an appropriate sized mesh, and a magnet
should be utilized to occasionally check for inappropriate metallic particles.
2. At least 10% of the rebar should be examined for internal voids using ultrasonic testing. If the ultrasonic
tester is unavailable, then destructive testing may be used.
DESCRIPTION INSPECTABLE INSPECTION METHOD
Water Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Sand Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Cement Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Aggregate Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Gravel Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Rebar Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Rebar ties & mesh Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
B. Masonry
*Note:
1. Precast is not acceptable if created off site unless constructed in the US and shipped secure. If a CST
inspects the precast as it is made, it is acceptable.
2. Stonework for the façade needs only visual inspection. Internal stone work must undergo a 3% random
destruction test.
3. Scaffolding should be inspected internally before allowed on site.
DESCRIPTION INSPECTABLE INSPECTION METHOD
Cement blocks & Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
brick
Precast concrete Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Stone Work Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Forms Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Scaffolding/work Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
platforms
Page 2 of 5
D. Metal Items
*Note:
Visual inspection applies only to common, commercially available items. Items requiring special fabrication
are not inspectable unless CST is present during fabrication.
DESCRIPTION INSPECTABLE INSPECTION METHOD
Structural Steel Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Metal Decking Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Metal Fabrications Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Metal Stairs Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Page 3 of 5
G. Doors and Windows (excluding locks)
DESCRIPTION INSPECTABLE INSPECTION METHOD
Metal Doors/Frames Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Wood Doors/Frames Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Metal Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Windows/Frames
Wood Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Windows/Frames
Vault Doors/Frames Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Glazing Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
H. Finishes
* Note:
Bundles of tiles will be unpacked and no more than two tiles at a time will be examined.
DESCRIPTION INSPECTABLE INSPECTION METHOD
Plaster Lath Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Plaster Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Gypsum Wallboard Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Raised Flooring Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Carpet and Curtains Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Paint Varnishes Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Adhesives Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Wall Coverings Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Ceramic Tile Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Acoustical Tile Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Page 4 of 5
J. Electrical Items
DESCRIPTION INSPECTABLE INSPECTION METHOD
Wire Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Conduit Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Junction boxes Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Outlets w/out built Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
ins
Outlets w/built ins Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Switches, Breakers Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Incandescent light Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
fixtures
Florescent light Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
fixtures
Light bulbs (tubes) Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Circuit breaker Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
boards
Electrical Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
component boards
Transformers Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Transient Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
suppressor
Voltage regulators Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Generators Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Power line Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
conditioners
Switch gears Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Telephone systems Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
K. Other Miscellaneous
DESCRIPTION INSPECTABLE INSPECTION METHOD
Chalk & tack boards Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Fire extinguishers Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Fire alarm systems Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Fire alarm sensors Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Sprinkler/gas heads Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Kitchen appliances Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
Electrical dark room Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
equipment
Security alarm Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
systems
Acoustical Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test
insulation
Locks Yes No X-Ray Ultrasonic Visual Metal Detector Destructive Test