Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Promass F

Download as pdf or txt
Download as pdf or txt
You are on page 1of 104

TI01034D/06/EN/08.

21 Products Solutions Services


71505580
2021-01-01

Technical Information
Proline Promass F 100
Coriolis flowmeter

The flowmeter with premium accuracy, robustness and an ultra-compact


transmitter
Application Your benefits
Measuring principle operates independently of physical fluid • Highest process safety – immune to fluctuating and harsh
properties such as viscosity or density environments
Device properties • Fewer process measuring points – multivariable
• Mass flow: measured error ±0.05 % (PremiumCal) measurement (flow, density, temperature)
• Pressure rating of sensor housing up to 40 bar (580 psi) • Space‐saving installation – no inlet/outlet run needs
• Nominal diameter: DN 8 to 250 (³⁄₈ to 10") • Space‐saving transmitter – full functionality on smallest
• Robust, ultra-compact transmitter housing footprint
• Highest degree of protection: IP69 • Time‐saving local operation without additional software and
• Local display available hardware – integrated web server
• Integrated verification – Heartbeat Technology
Proline Promass F 100

Table of contents

About this document . . . . . . . . . . . . . . . . . . . . . . . . 4 Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49


Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Interior cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . 49
Function and system design . . . . . . . . . . . . . . . . . . . 5
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Equipment architecture . . . . . . . . . . . . . . . . . . . . . . . . . 7 Medium temperature range . . . . . . . . . . . . . . . . . . . . . . 50
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Pressure-temperature ratings . . . . . . . . . . . . . . . . . . . . 50
Sensor housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Rupture disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Flow limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
System pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Thermal insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Vibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ex connection data . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mechanical construction . . . . . . . . . . . . . . . . . . . . 59
Low flow cut off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dimensions in SI units . . . . . . . . . . . . . . . . . . . . . . . . . 59
Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dimensions in US units . . . . . . . . . . . . . . . . . . . . . . . . . 79
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Process connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Pin assignment, device plug . . . . . . . . . . . . . . . . . . . . . . 30 Surface roughness . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Local display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . 39
Service interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Certificates and approvals . . . . . . . . . . . . . . . . . . . 96
CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
C-Tick symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Performance characteristics . . . . . . . . . . . . . . . . . . 41
Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Reference operating conditions . . . . . . . . . . . . . . . . . . . 41
Sanitary compatibility . . . . . . . . . . . . . . . . . . . . . . . . . 97
Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . 41
HART certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Certification PROFIBUS . . . . . . . . . . . . . . . . . . . . . . . . . 97
Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Certification PROFINET . . . . . . . . . . . . . . . . . . . . . . . . 98
Influence of ambient temperature . . . . . . . . . . . . . . . . . 43
EtherNet/IP certification . . . . . . . . . . . . . . . . . . . . . . . . 98
Influence of medium temperature . . . . . . . . . . . . . . . . . . 43
Modbus RS485 certification . . . . . . . . . . . . . . . . . . . . . 98
Influence of medium pressure . . . . . . . . . . . . . . . . . . . . 44
Pressure Equipment Directive . . . . . . . . . . . . . . . . . . . . 98
Design fundamentals . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Other standards and guidelines . . . . . . . . . . . . . . . . . . . 98

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Ordering information . . . . . . . . . . . . . . . . . . . . . . . 99


Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Application packages . . . . . . . . . . . . . . . . . . . . . . . 99
Special mounting instructions . . . . . . . . . . . . . . . . . . . . 47 Heartbeat Technology . . . . . . . . . . . . . . . . . . . . . . . . . 99
Installing the Safety Barrier Promass 100 . . . . . . . . . . . . 48 Concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Special density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 49 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 100
Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Communication-specific accessories . . . . . . . . . . . . . . . 100
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Service-specific accessories . . . . . . . . . . . . . . . . . . . . . 101
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 System components . . . . . . . . . . . . . . . . . . . . . . . . . . 102

2 Endress+Hauser
Proline Promass F 100

Supplementary documentation . . . . . . . . . . . . . . 102


Standard documentation . . . . . . . . . . . . . . . . . . . . . . . 102
Supplementary device-dependent documentation . . . . . . 103

Registered trademarks . . . . . . . . . . . . . . . . . . . . . 103

Endress+Hauser 3
Proline Promass F 100

About this document


Symbols used Electrical symbols

Symbol Meaning

Direct current

Alternating current

Direct current and alternating current

Ground connection
A grounded terminal which, as far as the operator is concerned, is grounded via a
grounding system.

Protective Earth (PE)


A terminal which must be connected to ground prior to establishing any other
connections.
The ground terminals are situated inside and outside the device:
• Inner ground terminal: Connects the protectiv earth to the mains supply.
• Outer ground terminal: Connects the device to the plant grounding system.

Symbols for certain types of information

Symbol Meaning

Permitted
Procedures, processes or actions that are permitted.

Preferred
Procedures, processes or actions that are preferred.

Forbidden
Procedures, processes or actions that are forbidden.

Tip
Indicates additional information.

Reference to documentation.

A Reference to page.

Reference to graphic.

Visual inspection.

Symbols in graphics

Symbol Meaning

1, 2, 3, ... Item numbers

1. , 2. , 3. , … Series of steps

A, B, C, ... Views

A-A, B-B, C-C, ... Sections

Hazardous area
-
Safe area (non-hazardous area)
.
Flow direction

4 Endress+Hauser
Proline Promass F 100

Function and system design


Measuring principle The measuring principle is based on the controlled generation of Coriolis forces. These forces are
always present in a system when both translational and rotational movements are superimposed.

Fc = 2 · ∆m (ν · ω)

Fc = Coriolis force

∆m = moving mass

ω = rotational velocity

ν = radial velocity in rotating or oscillating system

The amplitude of the Coriolis force depends on the moving mass ∆m, its velocity ν in the system and
thus on the mass flow. Instead of a constant rotational velocity ω, the sensor uses oscillation.
In the sensor, two parallel measuring tubes containing flowing fluid oscillate in antiphase, acting like
a tuning fork. The Coriolis forces produced at the measuring tubes cause a phase shift in the tube
oscillations (see illustration):
• At zero flow (when the fluid is at a standstill) the two tubes oscillate in phase (1).
• Mass flow causes deceleration of the oscillation at the inlet of the tubes (2) and acceleration at the
outlet (3).

1 2 3
A0028850

The phase difference (A-B) increases with increasing mass flow. Electrodynamic sensors register the
tube oscillations at the inlet and outlet. System balance is ensured by the antiphase oscillation of the
two measuring tubes. The measuring principle operates independently of temperature, pressure,
viscosity, conductivity and flow profile.
Density measurement
The measuring tube is continuously excited at its resonance frequency. A change in the mass and
thus the density of the oscillating system (comprising measuring tube and fluid) results in a
corresponding, automatic adjustment in the oscillation frequency. Resonance frequency is thus a
function of medium density. The microprocessor utilizes this relationship to obtain a density signal.
Volume measurement
Together with the measured mass flow, this is used to calculate the volume flow.
Temperature measurement
The temperature of the measuring tube is determined in order to calculate the compensation factor
due to temperature effects. This signal corresponds to the process temperature and is also available
as an output signal.

Endress+Hauser 5
Proline Promass F 100

Measuring system The device consists of a transmitter and a sensor. If a device with Modbus RS485 intrinsically safe is
ordered, the Safety Barrier Promass 100 is part of the scope of supply and must be implemented to
operate the device.
The device is available as a compact version:
The transmitter and sensor form a mechanical unit.

Transmitter

Promass 100 Device versions and materials:


• Compact, aluminum, coated:
Aluminum, AlSi10Mg, coated
• Compact, hygienic, stainless:
• Hygienic version, stainless steel 1.4301 (304)
• Optional: order code for "Sensor feature", option CC
A0016693 Hygienic version, for maximum corrosion resistance: stainless steel
1.4404 (316L)
• Ultra-compact, hygienic, stainless:
• Hygienic version, stainless steel 1.4301 (304)
• Optional: order code for "Sensor feature", option CC
Hygienic version, for maximum corrosion resistance: stainless steel
A0016694 1.4404 (316L)
Configuration:
• Via operating tools (e.g. FieldCare, DeviceCare)
• Additionally for device version with local display:
Via Web browser (e.g. Microsoft Internet Explorer)
• Also for device version with 4-20 mA HART, pulse/frequency/switch
A0016695
output:
Via Web browser (e.g. Microsoft Internet Explorer)
• Also for device version with EtherNet/IP output:
• Via Web browser (e.g. Microsoft Internet Explorer)
• Via Add-on Profile Level 3 for automation system from Rockwell
Automation
• Via Electronic Data Sheet (EDS)
• Also for device version with PROFINET output:
• Via Web browser (e.g. Microsoft Internet Explorer)
• Via device master file (GSD)

Sensor

PromassF • Excellent performance across a wide range of applications


• Simultaneous measurement of flow, volume flow, density and
temperature (multivariable)
• Immune to process influences
• Nominal diameter range: DN 8 to 250 (³⁄₈ to 10")
• Materials:
A0016507 • Sensor: stainless steel, 1.4301/1.4307 (304L); optional 1.4404
(316/316L)
• Measuring tubes: stainless steel, 1.4539 (904L); 1.4404
(316/316L); Alloy C22, 2.4602 (UNS N06022)
• Process connections: stainless steel, 1.4404 (316/316L); 1.4301
(304); Alloy C22, 2.4602 (UNS N06022)

Safety Barrier Promass 100

• Dual-channel safety barrier for installation in non-hazardous locations


or zone 2/div. 2:
• Channel 1: DC 24 V power supply
• Channel 2: Modbus RS485
• In addition to current, voltage and power limitation, it offers galvanic
isolation of circuits for explosion protection.
• Easy top-hat rail mounting (DIN 35 mm) for installation in control
A0016763
cabinets

6 Endress+Hauser
Proline Promass F 100

Equipment architecture
1
2 3 4 5

10

11

6 7 8

A0016779

1 Possibilities for integrating measuring devices into a system


1 Control system (e.g. PLC)
2 EtherNet/IP
3 PROFIBUS DP
4 PROFINET
5 Modbus RS485
6 4-20 mA HART, pulse/frequency/switch output
7 Safety Barrier Promass 100
8 Modbus RS485 intrinsically safe
9 Non-hazardous area
10 Non-hazardous area and Zone 2/Div. 2
11 Hazardous area and Zone 1/Div. 1

Safety IT security
We only provide a warranty if the device is installed and used as described in the Operating
Instructions. The device is equipped with security mechanisms to protect it against any inadvertent
changes to the device settings.
IT security measures in line with operators' security standards and designed to provide additional
protection for the device and device data transfer must be implemented by the operators themselves.

Endress+Hauser 7
Proline Promass F 100

Input
Measured variable Direct measured variables
• Mass flow
• Density
• Temperature

Calculated measured variables


• Volume flow
• Corrected volume flow
• Reference density

Measuring range Measuring ranges for liquids

DN Measuring range full scale values min(F) to max(F)

[mm] [in] [kg/h] [lb/min]

8 ³⁄₈ 0 to 2 000 0 to 73.50

15 ½ 0 to 6 500 0 to 238.9

25 1 0 to 18 000 0 to 661.5

40 1½ 0 to 45 000 0 to 1 654

50 2 0 to 70 000 0 to 2 573

80 3 0 to 180 000 0 to 6 615

100 4 0 to 350 000 0 to 12 860

150 6 0 to 800 000 0 to 29 400

250 10 0 to 2 200 000 0 to 80 850

Measuring ranges for gases


The full scale values depend on the density of the gas and can be calculated with the formula below:
max(G) =  max(F) · ρG : x

 max(G) Maximum full scale value for gas [kg/h]

 max(F) Maximum full scale value for liquid [kg/h]

 max(G) <  max(F)  max(G) can never be greater than  max(F)

ρG Gas density in [kg/m³] at operating conditions

x Constant dependent on nominal diameter

DN x

[mm] [in] [kg/m3]

8 ³⁄₈ 60

15 ½ 80

25 1 90

40 1½ 90

50 2 90

80 3 110

100 4 130

8 Endress+Hauser
Proline Promass F 100

DN x

[mm] [in] [kg/m3]

150 6 200

250 10 200

To calculate the measuring range, use the Applicator sizing tool →  101

Calculation example for gas


• Sensor: Promass F, DN 50
• Gas: Air with a density of 60.3 kg/m³ (at 20 °C and 50 bar)
• Measuring range (liquid): 70 000 kg/h
• x = 90 kg/m³ (for Promass F, DN 50)
Maximum possible full scale value:
 max(G) =  max(F) · ρG : x = 70 000 kg/h · 60.3 kg/m³ : 90 kg/m³ = 46 900 kg/h

Recommended measuring range


"Flow limit" section →  57

Operable flow range Over 1000 : 1.


Flow rates above the preset full scale value do not override the electronics unit, with the result that
the totalizer values are registered correctly.

Output
Output signal HART current output

Current output 4-20 mA HART (active)

Maximum output values • DC 24 V (no flow)


• 22.5 mA

Load 0 to 700 Ω

Resolution 0.38 µA

Damping Adjustable: 0.07 to 999 s

Assignable measured • Mass flow


variables • Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature

 The range of options increases if the measuring device has one or more
application packages.

Pulse/frequency/switch output

Function Can be set to pulse, frequency or switch output

Version Passive, open collector

Maximum input values • DC 30 V


• 25 mA

Voltage drop For 25 mA: ≤ DC 2 V

Pulse output

Pulse width Adjustable: 0.05 to 2 000 ms

Endress+Hauser 9
Proline Promass F 100

Maximum pulse rate 10 000 Impulse/s

Pulse value Adjustable

Assignable measured • Mass flow


variables • Volume flow
• Corrected volume flow

Frequency output

Output frequency Adjustable: 0 to 10 000 Hz

Damping Adjustable: 0 to 999 s

Pulse/pause ratio 1:1

Assignable measured • Mass flow


variables • Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature

 The range of options increases if the measuring device has one or more
application packages.

Switch output

Switching behavior Binary, conductive or non-conductive

Switching delay Adjustable: 0 to 100 s

Number of switching Unlimited


cycles

Assignable functions • Off


• On
• Diagnostic behavior
• Limit value
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1-3
• Flow direction monitoring
• Status
• Partially filled pipe detection
• Low flow cut off

 The range of options increases if the measuring device has one or more
application packages.

PROFIBUS DP

Signal encoding NRZ code

Data transfer 9.6 kBaud…12 MBaud

Modbus RS485

Physical interface In accordance with EIA/TIA-485-A standard

Terminating resistor • For device version used in non-hazardous areas or Zone 2/Div. 2: integrated
and can be activated via DIP switches on the transmitter electronics module
• For device version used in intrinsically safe areas: integrated and can be
activated via DIP switches on the Safety Barrier Promass 100

10 Endress+Hauser
Proline Promass F 100

EtherNet/IP

Standards In accordance with IEEE 802.3

PROFINET

Standards In accordance with IEEE 802.3

Signal on alarm Depending on the interface, failure information is displayed as follows:

Current output 4 to 20 mA

4 to 20 mA
Failure mode Choose from:
• 4 to 20 mA in accordance with NAMUR recommendation NE 43
• 4 to 20 mA in accordance with US
• Min. value: 3.59 mA
• Max. value: 22.5 mA
• Freely definable value between: 3.59 to 22.5 mA
• Actual value
• Last valid value

Pulse/frequency/switch output

Pulse output

Failure mode Choose from:


• Actual value
• No pulses

Frequency output

Failure mode Choose from:


• Actual value
• 0 Hz
• Defined value: 0 to 12 500 Hz

Switch output

Failure mode Choose from:


• Current status
• Open
• Closed

PROFIBUS DP

Status and alarm Diagnostics in accordance with PROFIBUS PA Profile 3.02


messages

Modbus RS485

Failure mode Choose from:


• NaN value instead of current value
• Last valid value

EtherNet/IP

Device diagnostics Device condition can be read out in Input Assembly

Endress+Hauser 11
Proline Promass F 100

PROFINET

Device diagnostics According to "Application Layer protocol for decentralized periphery", Version 2.3

Local display

Plain text display With information on cause and remedial measures

Backlight Red backlighting indicates a device error.

Status signal as per NAMUR recommendation NE 107

Interface/protocol
• Via digital communication:
• HART protocol
• PROFIBUS DP
• Modbus RS485
• EtherNet/IP
• PROFINET
• Via service interface
CDI-RJ45 service interface

Plain text display With information on cause and remedial measures

Additional information on remote operation →  92

Web server

Plain text display With information on cause and remedial measures

Light emitting diodes (LED)

Status information Status indicated by various light emitting diodes


The following information is displayed depending on the device version:
• Supply voltage active
• Data transmission active
• Device alarm/error has occurred
• EtherNet/IP network available
• EtherNet/IP connection established
• PROFINET network available
• PROFINET connection established
• PROFINET blinking feature

Ex connection data These values only apply for the following device version:
Order code for "Output", option M "Modbus RS485", for use in intrinsically safe areas

Safety Barrier Promass 100

Safety-related values
Terminal numbers

Supply voltage Signal transmission

2 (L-) 1 (L+) 26 (A) 27 (B)

Unom = DC 24 V Unom = DC 5 V
Umax = AC 260 V Umax = AC 260 V

12 Endress+Hauser
Proline Promass F 100

Intrinsically safe values


Terminal numbers

Supply voltage Signal transmission

20 (L-) 10 (L+) 62 (A) 72 (B)

Uo = 16.24 V
Io = 623 mA
Po = 2.45 W
With IIC 1): Lo = 92.8 µH, Co = 0.433 μF, Lo/Ro = 14.6 μH/Ω
With IIB: Lo= 372 µH, Co = 2.57 μF, Lo/Ro = 58.3 μH/Ω

 For an overview and for information on the interdependencies between the gas group - sensor - nominal
diameter, see the "Safety Instructions" (XA) document for the measuring device

1) The gas group depends on the sensor and nominal diameter ff.

Transmitter

Intrinsically safe values


Order code for Terminal numbers
"Approval"
Supply voltage Signal transmission

20 (L-) 10 (L+) 62 (A) 72 (B)

• Option BM: ATEX II2G + IECEx Z1 Ex ia, II2D Ex tb Ui = 16.24 V


• Option BO: ATEX II1/2G + IECEx Z0/Z1 Ex ia, II2D Ii = 623 mA
• Option BQ: ATEX II1/2G + IECEx Z0/Z1 Ex ia Pi = 2.45 W
• Option BU: ATEX II2G + IECEx Z1 Ex ia Li = 0 µH
• Option C2: CSA C/US IS Cl. I, II, III Div. 1 Ci = 6 nF
• Option 85: ATEX II2G + IECEx Z1 Ex ia + CSA C/US
IS Cl. I, II, III Div. 1

 For an overview and for information on the interdependencies between the gas group - sensor - nominal
diameter, see the "Safety Instructions" (XA) document for the measuring device

Low flow cut off The switch points for low flow cut off are user-selectable.

Protocol-specific data HART

Manufacturer ID 0x11

Device type ID 0x4A

HART protocol revision 7

Device description files Information and files under:


(DTM, DD) www.endress.com

HART load Min. 250 Ω

Endress+Hauser 13
Proline Promass F 100

Dynamic variables Read out the dynamic variables: HART command 3


The measured variables can be freely assigned to the dynamic variables.
Measured variables for PV (primary dynamic variable)
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary
dynamic variable)
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3

 The range of options increases if the measuring device has one or more
application packages.
Heartbeat Technology application package
Additional measured variables are available with the Heartbeat Technology
application package:
• Carrier pipe temperature
• Oscillation amplitude 0

Device variables Read out the device variables: HART command 9


The device variables are permanently assigned.
A maximum of 8 device variables can be transmitted:
• 0 = mass flow
• 1 = volume flow
• 2 = corrected volume flow
• 3 = density
• 4 = reference density
• 5 = temperature
• 6 = totalizer 1
• 7 = totalizer 2
• 8 = totalizer 3
• 13 = target mass flow
• 14 = carrier mass flow
• 15 = concentration

PROFIBUS DP

Manufacturer ID 0x11

Ident number 0x1561

Profile version 3.02

Device description files (GSD, Information and files under:


DTM, DD) • www.endress.com
On the product page for the device: Documents/Software → Device drivers
• www.profibus.org

14 Endress+Hauser
Proline Promass F 100

Output values Analog input 1 to 8


(from measuring device to • Mass flow
automation system) • Volume flow
• Corrected volume flow
• Target mass flow
• Carrier mass flow
• Density
• Reference density
• Concentration
• Temperature
• Carrier pipe temperature
• Electronic temperature
• Oscillation frequency
• Oscillation amplitude
• Frequency fluctuation
• Oscillation damping
• Tube damping fluctuation
• Signal asymmetry
• Exciter current
Digital input 1 to 2
• Partially filled pipe detection
• Low flow cut off
Totalizer 1 to 3
• Mass flow
• Volume flow
• Corrected volume flow

Input values Analog output 1 to 3 (fixed assignment)


(from automation system to • Pressure
measuring device) • Temperature
• Reference density
Digital output 1 to 3 (fixed assignment)
• Digital output 1: switch positive zero return on/off
• Digital output 2: perform zero point adjustment
• Digital output 3: switch switch output on/off
Totalizer 1 to 3
• Totalize
• Reset and hold
• Preset and hold
• Stop
• Operating mode configuration:
• Net flow total
• Forward flow total
• Reverse flow total

Supported functions • Identification & Maintenance


Simplest device identification on the part of the control system and
nameplate
• PROFIBUS upload/download
Reading and writing parameters is up to ten times faster with PROFIBUS
upload/download
• Condensed status
Simplest and self-explanatory diagnostic information by categorizing
diagnostic messages that occur

Configuration of the device • DIP switches on the I/O electronics module


address • Via operating tools (e.g. FieldCare)

Modbus RS485

Protocol Modbus Applications Protocol Specification V1.1

Device type Slave

Slave address range 1 to 247

Broadcast address range 0

Endress+Hauser 15
Proline Promass F 100

Function codes • 03: Read holding register


• 04: Read input register
• 06: Write single registers
• 08: Diagnostics
• 16: Write multiple registers
• 23: Read/write multiple registers

Broadcast messages Supported by the following function codes:


• 06: Write single registers
• 16: Write multiple registers
• 23: Read/write multiple registers

Supported baud rate • 1 200 BAUD


• 2 400 BAUD
• 4 800 BAUD
• 9 600 BAUD
• 19 200 BAUD
• 38 400 BAUD
• 57 600 BAUD
• 115 200 BAUD

Data transfer mode • ASCII


• RTU

Data access Each device parameter can be accessed via Modbus RS485.

 For Modbus register information, see "Description of device parameters"


documentation

EtherNet/IP

Protocol • The CIP Networks Library Volume 1: Common Industrial Protocol


• The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP

Communication type • 10Base-T


• 100Base-TX

Device profile Generic device (product type: 0x2B)

Manufacturer ID 0x49E

Device type ID 0x104A

Baud rates Automatic ¹⁰⁄₁₀₀ Mbit with half-duplex and full-duplex detection

Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs

Supported CIP connections Max. 3 connections

Explicit connections Max. 6 connections

I/O connections Max. 6 connections (scanner)

Configuration options for • DIP switches on the electronics module for IP addressing
measuring device • Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• Electronic Data Sheet (EDS) integrated in the measuring device

Configuration of the EtherNet • Speed: 10 MBit, 100 MBit, auto (factory setting)
interface • Duplex: half-duplex, full-duplex, auto (factory setting)

Configuration of the device • DIP switches on the electronics module for IP addressing (last octet)
address • DHCP
• Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• EtherNet/IP tools, e.g. RSLinx (Rockwell Automation)

Device Level Ring (DLR) No

16 Endress+Hauser
Proline Promass F 100

Fix Input

RPI 5 ms to 10 s (factory setting: 20 ms)

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0x66 64

T → O configuration: 0x64 44

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0x66 64

T → O configuration: 0x64 44

Input only Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0xC7 -

T → O configuration: 0x64 44

Input only Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0xC7 -

T → O configuration: 0x64 44

Input Assembly • Current device diagnostics


• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3

Configurable Input

RPI 5 ms to 10 s (factory setting: 20 ms)

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0x66 64

T → O configuration: 0x65 88

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0x66 64

T → O configuration: 0x65 88

Input only Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0xC7 -

T → O configuration: 0x65 88

Input only Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0xC7 -

T → O configuration: 0x65 88

Endress+Hauser 17
Proline Promass F 100

Configurable Input Assembly • Current device diagnostics


• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3

 The range of options increases if the measuring device has one or


more application packages.

Fix Output

Output Assembly • Activation of reset totalizers 1-3


• Activation of pressure compensation
• Activation of reference density compensation
• Activation of temperature compensation
• Reset totalizers 1-3
• External pressure value
• Pressure unit
• External reference density
• Reference density unit
• External temperature
• Temperature unit

Configuration

Configuration Assembly Only the most common configurations are listed below.
• Software write protection
• Mass flow unit
• Mass unit
• Volume flow unit
• Volume unit
• Corrected volume flow unit
• Corrected volume unit
• Density unit
• Reference density unit
• Temperature unit
• Pressure unit
• Length
• Totalizer 1-3:
• Assignment
• Unit
• Operating mode
• Failsafe mode
• Alarm delay

PROFINET

Protocol "Application layer protocol for decentral device periphery and distributed
automation", version 2.3

Conformity class B

Communication type 100 MBit/s

Device profile Application interface identifier 0xF600


Generic device

Manufacturer ID 0x11

Device type ID 0x844A

Device description files (GSD, Information and files under:


DTM) • www.endress.com
On the product page for the device: Documents/Software → Device drivers
• www.profibus.org

Baud rates Automatic 100 Mbit/s with full-duplex detection

18 Endress+Hauser
Proline Promass F 100

Cycle times From 8 ms

Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs

Supported connections • 1 x AR (Application Relation)


• 1 x Input CR (Communication Relation)
• 1 x Output CR (Communication Relation)
• 1 x Alarm CR (Communication Relation)

Configuration options for • DIP switches on the electronics module, for device name assignment (last
measuring device part)
• Manufacturer-specific software (FieldCare, DeviceCare)
• Web browser
• Device master file (GSD), can be read out via the integrated Web server of
the measuring device

Configuration of the device • DIP switches on the electronics module, for device name assignment (last
name part)
• DCP protocol

Output values Analog Input module (slot 1 to 14)


(from measuring device to • Mass flow
automation system) • Volume flow
• Corrected volume flow
• Target mass flow
• Carrier mass flow
• Density
• Reference density
• Concentration
• Temperature
• Carrier pipe temperature
• Electronic temperature
• Oscillation frequency
• Oscillation amplitude
• Frequency fluctuation
• Oscillation damping
• Tube damping fluctuation
• Signal asymmetry
• Exciter current
Discrete Input module (slot 1 to 14)
• Empty pipe detection
• Low flow cut off
Diagnostics Input module (slot 1 to 14)
• Last diagnostics
• Current diagnosis
Totalizer 1 to 3 (slot 15 to 17)
• Mass flow
• Volume flow
• Corrected volume flow
Heartbeat Verification module (fixed assignment)
Verification status (slot 23)

 The range of options increases if the measuring device has one or more
application packages.

Endress+Hauser 19
Proline Promass F 100

Input values Analog Output module (fixed assignment)


(from automation system to • External pressure (slot 18)
measuring device) • External temperature (slot 19)
• External reference density (slot 20)
Discrete Output module (fixed assignment)
• Activate/deactivate positive zero return (slot 21)
• Perform zero point adjustment (slot 22)
Totalizer 1 to 3 (slot 15 to 17)
• Totalize
• Reset and hold
• Preset and hold
• Stop
• Operating mode configuration:
• Net flow total
• Forward flow total
• Reverse flow total
Heartbeat Verification module (fixed assignment)
Start verification (slot 23)

 The range of options increases if the measuring device has one or more
application packages.

Supported functions • Identification & Maintenance


Simple device identification via:
• Control system
• Nameplate
• Measured value status
The process variables are communicated with a measured value status
• Blinking feature via the local display for simple device identification and
assignment

Administration of software options


Input/output value Process variable Category Slot

Output value Mass flow Process variable 1 to 14

Volume flow

Corrected volume flow

Density

Reference density

Temperature

Electronic temperature

Oscillation frequency

Frequency fluctuation

Oscillation damping

Oscillation frequency

Signal asymmetry

Exciter current

Empty pipe detection

Low flow cut off

Current device diagnostics

Previous device diagnostics

Output value Target mass flow Concentration 1) 1 to 14

Carrier mass flow

Concentration

Output value Carrier pipe temperature Heartbeat 2) 1 to 14

20 Endress+Hauser
Proline Promass F 100

Input/output value Process variable Category Slot

Oscillation damping 1

Oscillation frequency 1

Oscillation amplitude 0

Oscillation amplitude 1

Frequency fluctuation 1

Tube damping fluctuation 1

Exciter current 1

Input value External density Process monitoring 18

External temperature 19

External reference density 20

Flow override 21

Zero point adjustment 22


2)
Status verification Heartbeat Verification 23

1) Only available with the "Concentration" application package.


2) Only available with the "Heartbeat" application package.

Endress+Hauser 21
Proline Promass F 100

Startup configuration
Startup configuration If startup configuration is enabled, the configuration of the most important
(NSU) device parameters is taken from the automation system and used.
The following configuration is taken from the automation system:
• Management
• Software revision
• Write protection
• System units
• Mass flow
• Mass
• Volume flow
• Volume
• Corrected volume flow
• Corrected volume
• Density
• Reference density
• Temperature
• Pressure
• Concentration application package
• Coefficients A0 to A4
• Coefficients B1 to B3
• Sensor adjustment
• Process parameter
• Damping (flow, density, temperature)
• Flow override
• Low flow cut off
• Assign process variable
• Switch-on/switch-off point
• Pressure shock suppression
• Empty pipe detection
• Assign process variable
• Limit values
• Response time
• Max. damping
• Corrected volume flow calculation
• External reference density
• Fixed reference density
• Reference temperature
• Linear expansion coefficient
• Square expansion coefficient
• Measuring mode
• Medium
• Gas type
• Reference sound velocity
• Temperature coefficient sound velocity
• External compensation
• Pressure compensation
• Pressure value
• External pressure
• Diagnostic settings
• Diagnostic behavior for diverse diagnostic information

22 Endress+Hauser
Proline Promass F 100

Power supply
Terminal assignment Overview: housing version and connection versions

1 2

1.1 1.2 1.3 2.1 2.2

3 4

C 3.1 3.2 4.1 4.2

A0016770

A Housing version: compact, aluminum coated


B Housing version: compact, hygienic, stainless
C Housing version: ultra-compact, hygienic, stainless
1 Connection version: 4-20 mA HART, pulse/frequency/switch output
1.1 Signal transmission: pulse/frequency/switch output
1.2 Signal transmission: 4-20 mA HART
1.3 Supply voltage
2 Connection version: Modbus RS485
2.1 Signal transmission
2.2 Supply voltage
3 Connection versions: EtherNet/IP and PROFINET
3.1 Signal transmission
3.2 Supply voltage
4 Connection version: PROFIBUS DP
4.1 Signal transmission
4.2 Supply voltage

Transmitter

Connection version 4-20 mA HART with pulse/frequency/switch output


Order code for "Output", option B

Endress+Hauser 23
Proline Promass F 100

Depending on the housing version, the transmitters can be ordered with terminals or device plugs.

Connection methods available


Order code Possible options for order code
"Housing" Power "Electrical connection"
Outputs
supply

Options Terminals Terminals • Option A: coupling M20x1


A, B • Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

Options Device plugs Terminals • Option L: plug M12x1 + thread NPT ½"
A, B →  31 • Option N: plug M12x1 + coupling M20
• Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

Options Device plugs Device plugs Option Q: 2 x plug M12x1


A, B, C →  31 →  31

Order code for "Housing":


• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C ultra-compact, hygienic, stainless

24 +
_ 3
25

26 +
_ 2
27

1 L+
1
2 L_

A0016888

2 Terminal assignment 4-20 mA HART with pulse/frequency/switch output


1 Power supply: DC 24 V
2 Output 1: 4-20 mA HART (active)
3 Output 2: pulse/frequency/switch output (passive)

Terminal number
Order code
Power supply Output 1 Output 2
"Output"
2 (L-) 1 (L+) 27 (–) 26 (+) 25 (–) 24 (+)

Option B DC 24 V 4-20 mA HART (active) Pulse/frequency/switch


output (passive)

Order code for "Output":


Option B: 4-20 mA HART with pulse/frequency/switch output

24 Endress+Hauser
Proline Promass F 100

PROFIBUS DP connection version


For use in the non-hazardous area and Zone 2/Div. 2

Order code for "Output", option L


Depending on the housing version, the transmitters can be ordered with terminals or device plugs.

Connection methods available


Order code Possible options for order code
"Housing" Power "Electrical connection"
Output
supply

Options Terminals Terminals • Option A: coupling M20x1


A, B • Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

Options Device plug Terminals • Option L: plug M12x1 + thread NPT ½"
A, B connectors • Option N: plug M12x1 + coupling M20
→  31 • Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

Options Device plug Device plug Option Q: 2 x plug M12x1


A, B, C connectors connectors
→  31 →  31

Order code for "Housing":


• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C ultra-compact, hygienic, stainless

26 B
27 A 2

1 L+
1
2 L_

A0022716

3 PROFIBUS DP terminal assignment


1 Power supply: DC 24 V
2 PROFIBUS DP

Terminal number

Order code Power supply Output


"Output"
2 (L-) 1 (L+) 26 (RxD/TxD-P) 27 (RxD/TxD-
N)

Option L DC 24 V B A

Order code for "Output":


Option L: PROFIBUS DP, for use in non-hazardous areas and Zone 2/Div. 2

Endress+Hauser 25
Proline Promass F 100

Modbus RS485 connection version


For use in the non-hazardous area and Zone 2/Div. 2

Order code for "Output", option M


Depending on the housing version, the transmitters can be ordered with terminals or device plugs.

Connection methods available


Order code Possible options for order code
"Housing" Power "Electrical connection"
Output
supply

Options Terminals Terminals • Option A: coupling M20x1


A, B • Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

Options Device plugs Terminals • Option L: plug M12x1 + thread NPT ½"
A, B →  31 • Option N: plug M12x1 + coupling M20
• Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

Options Device plugs Device plugs Option Q: 2 x plug M12x1


A, B, C →  31 →  31

Order code for "Housing":


• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C: ultra-compact, hygienic, stainless

26 B
2
27 A

1 L+
1
2 L_

A0019528

4 Modbus RS485 terminal assignment, connection version for use in non-hazardous areas and Zone 2/Div.
2
1 Power supply: DC 24 V
2 Modbus RS485

Terminal number
Order code
Power supply Output
"Output"
1 (L+) 2 (L-) 26 (B) 27 (A)

Option M DC 24 V Modbus RS485

Order code for "Output":


Option M: Modbus RS485, for use in non-hazardous areas and Zone 2/Div. 2

26 Endress+Hauser
Proline Promass F 100

Modbus RS485 connection version


For use in the intrinsically safe area. Connection via Safety Barrier Promass 100.

Order code for "Output", option M


Depending on the housing version, the transmitters can be ordered with terminals or device plugs.

Connection methods available


Order code Possible options for order code
"Housing" Power "Electrical connection"
Output
supply

Options Terminals Terminals • Option A: coupling M20x1


A, B • Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

A, B, C Device plugs Option I: plug M12x1


→  31

Order code for "Housing":


• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C ultra-compact, hygienic, stainless

62 B
2
72 A

10 L+
1
20 L_

A0030219

5 Modbus RS485 terminal assignment, connection version for use in intrinsically safe areas (connection via
Safety Barrier Promass 100)
1 Intrinsically safe power supply
2 Modbus RS485

Order code
10 (L+) 20 (L-) 62 (B) 72 (A)
"Output"

Option M Intrinsically safe supply voltage Modbus RS485 intrinsically safe

Order code for "Output":


Option M: Modbus RS485, for use in the intrinsically safe area (connection via Safety Barrier Promass 100)

Endress+Hauser 27
Proline Promass F 100

EtherNet/IP connection version


Order code for "Output", option N
Depending on the housing version, the transmitters can be ordered with terminals or device plugs.

Connection methods available


Order code Possible options for order code
"Housing" Power "Electrical connection"
Output
supply

Options Device plug Terminals • Option L: plug M12x1 + thread NPT ½"
A, B connectors • Option N: plug M12x1 + coupling M20
→  32 • Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

Options Device plug Device plug Option Q: 2 x plug M12x1


A, B, C connectors connectors
→  32 →  32

Order code for "Housing":


• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C ultra-compact, hygienic, stainless

1 L+
1
2 L_

A0017054

6 EtherNet/IP terminal assignment


1 Power supply: DC 24 V
2 EtherNet/IP

Terminal number
Order code
Power supply Output
"Output"
2 (L-) 1 (L+) Device plug M12x1

Option N DC 24 V EtherNet/IP

Order code for "Output":


Option N: EtherNet/IP

28 Endress+Hauser
Proline Promass F 100

PROFINET connection version


Order code for "Output", option R
Depending on the housing version, the transmitters can be ordered with terminals or device plugs.

Connection methods available


Order code Possible options for order code
"Housing" Power "Electrical connection"
Output
supply

Options Device plug Terminals • Option L: plug M12x1 + thread NPT ½"
A, B connectors • Option N: plug M12x1 + coupling M20
→  30 • Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

Options Device plug Device plug Option Q: 2 x plug M12x1


A, B, C connectors connectors
→  30 →  30

Order code for "Housing":


• Option A: compact, coated aluminum
• Option B: compact, hygienic, stainless
• Option C ultra-compact, hygienic, stainless

1 L+
1
2 L_

A0017054

7 PROFINET terminal assignment


1 Power supply: DC 24 V
2 PROFINET

Terminal number
Order code
Power supply Output
"Output"
2 (L-) 1 (L+) Device plug M12x1

Option R DC 24 V PROFINET

Order code for "Output":


Option R: PROFINET

Endress+Hauser 29
Proline Promass F 100

Safety Barrier Promass 100

2 1 26 27
L L+ B A
Power Modbus
supply RS485
1 24VDC

Safe area

Power
Lift panel for
bus termination
Communication
A

Safety Barrier
Promass 100

Hazardous area
A Power Modbus
supply RS485

L L+ B A
20 10 62 72

2
A0030220

8 Safety Barrier Promass 100 with terminals


1 Non-hazardous area, Zone 2, Class I Division 2
2 Intrinsically safe area

Pin assignment, device plug Order codes for the M12x1 connectors, see the "Order code for electrical connection" column:
• 4-20 mA HART, pulse/frequency/switch output →  23
• PROFIBUS DP→  25
• Modbus RS485 →  26
• EtherNet/IP →  28
• PROFINET→  29

Supply voltage

For all connection versions except MODBUS RS485 intrinsically safe (device side)
Device plug MODBUS RS485 intrinsically safe with supply voltage →  31

2 Pin Assignment

1 L+ DC 24 V

2 Not assigned
3 1
3 Not assigned
5 4 L- DC 24 V
4
A0029042
5 Grounding/shielding

Coding Plug/socket

A Plug

The following is recommended as a socket:


• Binder, series 763, part no. 79 3440 35 05
• Alternatively: Phoenix part no. 1669767 SAC-5P-M12MS
• With the order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output
• With the order code for "Output", option N: EtherNet/IP
• When using the device in a hazardous location: Use a suitably certified socket.

30 Endress+Hauser
Proline Promass F 100

4-20 mA HART with pulse/frequency/switch output

Device plug for signal transmission (device side)

2 Pin Assignment

1 + 4-20 mA HART (active)

2 - 4-20 mA HART (active)


1 3
3 + Pulse/frequency/switch output (passive)
5 4 - Pulse/frequency/switch output (passive)
4
A0016810
5 Grounding/shielding

Coding Plug/socket

A Socket

 •• When
Recommended plug: Binder, series 763, part no. 79 3439 12 05
using the device in a hazardous location, use a suitably certified plug.

PROFIBUS DP
For use in the non-hazardous area and Zone 2/Div. 2.

Device plug for signal transmission (device side)

2 Pin Assignment

1 Not assigned

2 A PROFIBUS DP
1 3
3 Not assigned
5 4 B PROFIBUS DP
4
A0016811
5 Grounding/shielding

Coding Plug/socket

B Socket

 •• When
Recommended plug: Binder, series 763, part no. 79 4449 20 05
using the device in a hazardous location, use a suitably certified plug.

MODBUS RS485

Device plug for signal transmission with supply voltage (device side), MODBUS RS485 (intrinsically
safe)

2 Pin Assignment

1 L+ Supply voltage, intrinsically safe

2 A
3 1 Modbus RS485 intrinsically safe
3 B
5 4 L- Supply voltage, intrinsically safe
4
A0029042
5 Grounding/shielding

Coding Plug/socket

A Plug

 •• Recommended socket: Binder, series 763, part no. 79 3439 12 05


When using the device in a hazardous location: Use a suitably certified socket.

Endress+Hauser 31
Proline Promass F 100

Device plug for signal transmission (device side), MODBUS RS485 (not intrinsically safe)
For use in the non-hazardous area and Zone 2/Div. 2.

2 Pin Assignment

1 Not assigned

2 A Modbus RS485
1 3
3 Not assigned
5 4 B Modbus RS485
4
A0016811
5 Grounding/shielding

Coding Plug/socket

B Socket

 •• When
Recommended plug: Binder, series 763, part no. 79 4449 20 05
using the device in a hazardous location, use a suitably certified plug.

EtherNet/IP

Device plug for signal transmission (device side)

2 Pin Assignment

1 + Tx

2 + Rx
1 3
3 - Tx

4 - Rx
4
A0016812
Coding Plug/socket

D Socket

 Recommended plug:
• Binder, series 763, part no. 99 3729 810 04
• Phoenix, part no. 1543223 SACC-M12MSD-4Q
• When using the device in a hazardous location, use a suitably certified plug.

PROFINET

Device plug for signal transmission (device side)

2 Pin Assignment

1 + TD +

2 + RD +
1 3
3 - TD –

4 - RD –
4
A0016812
Coding Plug/socket

D Socket

 Recommended plug:
• Binder, series 763, part no. 99 3729 810 04
• Phoenix, part no. 1543223 SACC-M12MSD-4Q
• When using the device in a hazardous location, use a suitably certified plug.

Supply voltage The power unit must be tested to ensure it meets safety requirements (e.g. PELV, SELV).

32 Endress+Hauser
Proline Promass F 100

Transmitter
For device version with communication type:
• HART, PROFIBUS DP, EtherNet/IP: DC 20 to 30 V
• Modbus RS485, device version:
• For use in the non-hazardous area and Zone 2/Div. 2: DC 20 to 30 V
• For use in the intrinsically safe area: power supply via Safety Barrier Promass 100

Promass 100 safety barrier


DC 20 to 30 V

Power consumption Transmitter

Maximum
Order code for "Output"
Power consumption

Option B: 4-20 mA HART with pulse/frequency/switch output 3.5 W

Option L: PROFIBUS DP 3.5 W

Option M Modbus RS485, for use in non-hazardous areas and Zone 2/


3.5 W
Div. 2

Option M: Modbus RS485, for use in intrinsically safe areas 2.45 W

Option N: EtherNet/IP 3.5 W

Option R: PROFINET 3.5 W

Promass 100 safety barrier


Maximum
Order code for "Output"
Power consumption

Option M: Modbus RS485, for use in intrinsically safe areas 4.8 W

Current consumption Transmitter

Maximum Maximum
Order code for "Output"
Current consumption switch-on current

Option B: 4-20mA HART, pul./freq./switch output 145 mA 18 A (< 0.125 ms)

Option L: PROFIBUS DP 145 mA 18 A (< 0.125 ms)

Option M Modbus RS485, for use in non-hazardous


90 mA 10 A (< 0.8 ms)
areas and Zone 2/Div. 2

Option M: Modbus RS485, for use in intrinsically safe


145 mA 16 A (< 0.4 ms)
areas

Option N: EtherNet/IP 145 mA 18 A (< 0.125 ms)

Option R: PROFINET 145 mA 18 A (< 0.125 ms)

Promass 100 safety barrier

Maximum Maximum
Order code for "Output"
Current consumption switch-on current

Option M: Modbus RS485, for use in intrinsically safe


230 mA 10 A (< 0.8 ms)
areas

Power supply failure Depending on the device version, the configuration is retained in the device memoryor in the
pluggable data memory (HistoROM DAT).

Endress+Hauser 33
Proline Promass F 100

Electrical connection Connecting the transmitter

A B C

1 2 1 2 3 4
A0016924

A Housing version: compact, aluminum coated


B Housing version: compact hygienic, stainless
1 Cable entry or device plug for signal transmission
2 Cable entry or device plug for supply voltage
C Housing version: ultra-compact, hygienic, stainless, M12 device plug
3 Device plug for signal transmission
4 Device plug for supply voltage

• Terminal assignment→  23
• Pin assignment, device plug→  30
In the case of device versions with a connector, the transmitter housing does not need to be
opened to connect the signal cable or power supply cable.

Connection examples

Current output 4 to 20 mA HART

1 2 3
4...20 mA

4 5
A0029055

9 Connection example for 4 to 20 mA HART current output (active)


1 Automation system with current input (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  39
3 Connection for HART operating devices →  92
4 Resistor for HART communication (≥ 250 Ω): observe maximum load
5 Analog display unit: observe maximum load
6 Transmitter

34 Endress+Hauser
Proline Promass F 100

1 2 3 4

4...20 mA

A0028762

 10 Connection example for 4 to 20 mA HART current output (passive)


1 Automation system with current input (e.g. PLC)
2 Power supply
3 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  39
4 Analog display unit: observe maximum load
5 Transmitter

Pulse/frequency output

1 2

12345
A0028761

 11 Connection example for pulse/frequency output (passive)


1 Automation system with pulse/frequency input (e.g. PLC)
2 Power supply
3 Transmitter: Observe input values →  9

Switch output

1 2

A0028760

 12 Connection example for switch output (passive)


1 Automation system with switch input (e.g. PLC)
2 Power supply
3 Transmitter: Observe input values

Endress+Hauser 35
Proline Promass F 100

PROFIBUS DP

1 2 3

A A
4
B
B

A
4
B

A0028765

 13 Connection example for PROFIBUS DP, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications
3 Transmitter

If baud rates > 1.5 MBaud an EMC cable entry must be used and the cable shield must continue
as far as the terminal wherever possible.

Modbus RS485

Modbus RS485, non-hazardous area and Zone 2/Div. 2

1 2 3

A A
4
B
B

A
4
B

A0028765

 14 Connection example for Modbus RS485, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  39
3 Distribution box
4 Transmitter

36 Endress+Hauser
Proline Promass F 100

Modbus RS485 intrinsically safe

1 2 3 4

A A
A A B B
L+ 8
B L+
B
L- L+ L- L-

5 6 7
A0028766

 15 Connection example for Modbus RS485 intrinsically safe


1 Control system (e.g. PLC)
2 Cable shield, observe cable specifications
3 Safety Barrier Promass 100
4 Observe cable specifications
5 Non-hazardous area
6 Non-hazardous area and Zone 2/Div. 2
7 Intrinsically safe area
8 Transmitter

EtherNet/IP

1 2 3 4

A0028767

 16 Connection example for EtherNet/IP


1 Control system (e.g. PLC)
2 Ethernet switch
3 Observe cable specifications
4 Device plug
5 Transmitter

Endress+Hauser 37
Proline Promass F 100

PROFINET

1 2 3 4

A0016805

 17 Connection example for PROFINET


1 Control system (e.g. PLC)
2 Ethernet switch
3 Observe cable specifications
4 Device plug
5 Transmitter

HART input

1 2 3 4

4...20 mA
+
5
-

-
+ 6

A0019828

 18 Connection example for HART input (burst mode) via current output (active)
1 Cable shield, observe cable specifications
2 Resistor for HART communication (≥ 250 Ω): observe maximum load
3 Connection for HART operating devices
4 Analog display unit
5 Transmitter
6 Sensor for external measured variable

38 Endress+Hauser
Proline Promass F 100

1 2 3 4 5

4...20 mA
+
+ 6
-
-
-
+
-
7
+
4...20 mA

2 3 4 5
A0019830

 19 Connection example for HART input (master mode) via current output (active)
1 Automation system with current input (e.g. PLC).
Prerequisite: automation system with HART version 6, HART commands 113 and 114 can be processed.
2 Cable shield, observe cable specifications
3 Resistor for HART communication (≥ 250 Ω): observe maximum load
4 Connection for HART operating devices
5 Analog display unit
6 Transmitter
7 Sensor for external measured variable

Potential equalization Requirements


No special measures for potential equalization are required.
Please consider the following to ensure correct measurement:
• Same electrical potential for the fluid and sensor
• Company-internal grounding concepts
For devices intended for use in hazardous locations, please observe the guidelines in the
Ex documentation (XA).

Terminals Transmitter
Spring terminals for wire cross-sections0.5 to 2.5 mm2 (20 to 14 AWG)
Promass 100 safety barrier
Plug-in screw terminals for wire cross-sections0.5 to 2.5 mm2 (20 to 14 AWG)

Cable entries • Cable gland: M20 × 1.5 with cable Ø 6 to 12 mm (0.24 to 0.47 in)
• Thread for cable entry:
• M20
• G ½"
• NPT ½"

Cable specification Permitted temperature range


• The installation guidelines that apply in the country of installation must be observed.
• The cables must be suitable for the minimum and maximum temperatures to be expected.

Power supply cable


Standard installation cable is sufficient.

Signal cable

Current output 4 to 20 mA HART


A shielded cable is recommended. Observe grounding concept of the plant.

Pulse/frequency/switch output
Standard installation cable is sufficient.

Endress+Hauser 39
Proline Promass F 100

PROFIBUS DP
The IEC 61158 standard specifies two types of cable (A and B) for the bus line which can be used for
every transmission rate. Cable type A is recommended.

Cable type A

Characteristic impedance 135 to 165 Ω at a measuring frequency of 3 to 20 MHz

Cable capacitance < 30 pF/m

Wire cross-section > 0.34 mm2 (22 AWG)

Cable type Twisted pairs

Loop resistance ≤110 Ω/km

Signal damping Max. 9 dB over the entire length of the cable cross-section

Shield Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.

Modbus RS485
The EIA/TIA-485 standard specifies two types of cable (A and B) for the bus line which can be used
for every transmission rate. Cable type A is recommended.

Cable type A

Characteristic impedance 135 to 165 Ω at a measuring frequency of 3 to 20 MHz

Cable capacitance < 30 pF/m

Wire cross-section > 0.34 mm2 (22 AWG)

Cable type Twisted pairs

Loop resistance ≤110 Ω/km

Signal damping Max. 9 dB over the entire length of the cable cross-section

Shield Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.

EtherNet/IP
The standard ANSI/TIA/EIA-568-B.2 Annex specifies CAT 5 as the minimum category for a cable
used for EtherNet/IP. CAT 5e and CAT 6 are recommended.
For more information on planning and installing EtherNet/IP networks, please refer to the
"Media Planning and Installation Manual. EtherNet/IP" of ODVA Organization

PROFINET
Standard IEC 61156-6 specifies CAT 5 as the minimum category for a cable used for PROFINET. CAT
5e and CAT 6 are recommended.
For more information on planning and installing PROFINET networks, see: "PROFINET Cabling
and Interconnection Technology", Guideline for PROFINET

Connecting cable between Safety Barrier Promass 100 and measuring device

Cable type Shielded twisted-pair cable with 2x2 wires. When grounding the cable shield,
observe the grounding concept of the plant.

Maximum cable resistance 2.5 Ω, one side

Comply with the maximum cable resistance specifications to ensure the operational reliability
of the measuring device.

40 Endress+Hauser
Proline Promass F 100

The maximum cable length for individual wire cross-sections is specified in the table below. Observe
the maximum capacitance and inductance per unit length of the cable and connection values for
hazardous areas .

Wire cross-section Maximum cable length

[mm2] [AWG] [m] [ft]

0.5 20 70 230

0.75 18 100 328

1.0 17 100 328

1.5 16 200 656

2.5 14 300 984

Performance characteristics
Reference operating • Error limits based on ISO 11631
conditions • Water with +15 to +45 °C (+59 to +113 °F) at2 to 6 bar (29 to 87 psi)
• Specifications as per calibration protocol
• Accuracy based on accredited calibration rigs that are traced to ISO 17025.
To obtain measured errors, use the Applicator sizing tool →  101

Maximum measured error o.r. = of reading; 1 g/cm³ = 1 kg/l; T = medium temperature

Base accuracy
Design fundamentals →  44

Mass flow and volume flow (liquids)


±0.05 % o.r. (PremiumCal; order code for "Calibration flow", option D, for mass flow)
±0.10 % o.r.

Mass flow (gases)


±0.25 % o.r.

Density (liquids)

Under reference conditions Standard density calibration Wide-range


Density specification 1) 2)

[g/cm³] [g/cm³] [g/cm³]

±0.0005 ±0.0005 ±0.001

1) Valid range for special density calibration: 0 to 2 g/cm³, +5 to +80 °C (+41 to +176 °F)
2) Order code for "Application package", option EE "Special density"

Temperature
±0.5 °C ± 0.005 · T °C (±0.9 °F ± 0.003 · (T – 32) °F)

Endress+Hauser 41
Proline Promass F 100

Zero point stability

DN Zero point stability

[mm] [in] [kg/h] [lb/min]

8 ³⁄₈ 0.030 0.001

15 ½ 0.200 0.007

25 1 0.540 0.019

40 1½ 2.25 0.083

50 2 3.50 0.129

80 3 9.0 0.330

100 4 14.0 0.514

150 6 32.0 1.17

250 10 88.0 3.23

Flow values
Flow values as turndown parameter depending on nominal diameter.

SI units

DN 1:1 1:10 1:20 1:50 1:100 1:500

[mm] [kg/h] [kg/h] [kg/h] [kg/h] [kg/h] [kg/h]

8 2 000 200 100 40 20 4

15 6 500 650 325 130 65 13

25 18 000 1 800 900 360 180 36

40 45 000 4 500 2 250 900 450 90

50 70 000 7 000 3 500 1 400 700 140

80 180 000 18 000 9 000 3 600 1 800 360

100 350 000 35 000 17 500 7 000 3 500 700

150 800 000 80 000 40 000 16 000 8 000 1 600

250 2 200 000 220 000 110 000 44 000 22 000 4 400

US units

DN 1:1 1:10 1:20 1:50 1:100 1:500

[inch] [lb/min] [lb/min] [lb/min] [lb/min] [lb/min] [lb/min]

³⁄₈ 73.50 7.350 3.675 1.470 0.735 0.147

½ 238.9 23.89 11.95 4.778 2.389 0.478

1 661.5 66.15 33.08 13.23 6.615 1.323

1½ 1 654 165.4 82.70 33.08 16.54 3.308

2 2 573 257.3 128.7 51.46 25.73 5.146

3 6 615 661.5 330.8 132.3 66.15 13.23

4 12 860 1 286 643.0 257.2 128.6 25.72

6 29 400 2 940 1 470 588 294 58.80

10 80 850 8 085 4 043 1 617 808.5 161.7

42 Endress+Hauser
Proline Promass F 100

Accuracy of outputs
The output accuracy must be factored into the measured error if analog outputs are used, but
can be ignored for fieldbus outputs (e.g. Modbus RS485, EtherNet/IP).
The outputs have the following base accuracy specifications.

Current output

Accuracy Max. ±5 µA

Pulse/frequency output
o.r. = of reading

Accuracy Max. ±50 ppm o.r. (over the entire ambient temperature range)

Repeatability o.r. = of reading; 1 g/cm3 = 1 kg/l; T = medium temperature

Base repeatability
Design fundamentals →  44

Mass flow and volume flow (liquids)


±0.025 % o.r. (PremiumCal, for mass flow)
±0.05 % o.r.

Mass flow (gases)


±0.20 % o.r.

Density (liquids)
±0.00025 g/cm3

Temperature
±0.25 °C ± 0.0025 · T °C (±0.45 °F ± 0.0015 · (T–32) °F)

Response time The response time depends on the configuration (damping).

Influence of ambient Current output


temperature
o.r. = of reading

Temperature coefficient Max. ±0.005 % o.r./°C

Pulse/frequency output

Temperature coefficient No additional effect. Included in accuracy.

Influence of medium Mass flow and volume flow


temperature
o.f.s. = of full scale value
When there is a difference between the temperature for zero point adjustment and the process
temperature, the additional measured error of the sensor is typically ±0.0002 % o.f.s./°C (±0.0001 %
o. f.s./°F).
The effect is reduced if zero point adjustment is performed at process temperature.

Density
When there is a difference between the density calibration temperature and the process
temperature, the typical measured error of the sensor is
±0.00005 g/cm3 /°C (±0.000025 g/cm3 /°F). Field density calibration is possible.

Endress+Hauser 43
Proline Promass F 100

Wide-range density specification (special density calibration)


If the process temperature is outside the valid range (→  41) the measured error is
±0.00005 g/cm3 /°C (±0.000025 g/cm3 /°F)

3
[kg/m ]
18
16
14
12 1
10
8
2
6
4
2
0
-50 0 100 200 300 [°C]

-80 0 80 160 240 320 400 480 560 [°F]


A0034654

1 Field density calibration, for example at +20 °C (+68 °F)


2 Special density calibration

Temperature
±0.005 · T °C (± 0.005 · (T – 32) °F)

Influence of medium The table below shows the effect on accuracy of mass flow due to a difference between calibration
pressure pressure and process pressure.
o.r. = of reading
It is possible to compensate for the effect by:
• Reading in the current pressure measured value via the current input.
• Specifying a fixed value for the pressure in the device parameters.
Operating Instructions .

DN [% o.r./bar] [% o.r./psi]

[mm] [in]

8 3/8 no influence

15 ½ no influence

25 1 no influence

40 1½ –0.003 –0.0002

50 2 –0.008 –0.0006

80 3 –0.009 –0.0006

100 4 –0.007 –0.0005

150 6 –0.009 –0.0006

250 10 –0.009 –0.0006

Design fundamentals o.r. = of reading, o.f.s. = of full scale value


BaseAccu = base accuracy in % o.r., BaseRepeat = base repeatability in % o.r.
MeasValue = measured value; ZeroPoint = zero point stability

44 Endress+Hauser
Proline Promass F 100

Calculation of the maximum measured error as a function of the flow rate


Flow rate Maximum measured error in % o.r.

ZeroPoint
³ BaseAccu ⋅ 100 ± BaseAccu
A0021339
A0021332

ZeroPoint ZeroPoint
< BaseAccu ⋅ 100 MeasValue ⋅ 100
±
A0021333 A0021334

Calculation of the maximum repeatability as a function of the flow rate


Flow rate Maximum repeatability in % o.r.

½ ⋅ ZeroPoint
³ BaseRepeat ⋅ 100
A0021340
A0021335

½ ⋅ ZeroPoint ZeroPoint
< BaseRepeat ⋅ 100 ± ½ ⋅ MeasValue ⋅ 100
A0021336 A0021337

Example for maximum measured error

E [%]
2.5
2.0
1.5
1.0
0.5
0
0 10 20 30 40 50 60 70 80 90 100 Q [%]
A0028808

E Maximum measured error in % o.r. (example with PremiumCal)


Q Flow rate in % of maximum full scale value

Installation
No special measures such as supports etc. are necessary. External forces are absorbed by the
construction of the device.

Mounting location

A0028772

To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid
the following mounting locations in the pipe:
• Highest point of a pipeline.
• Directly upstream of a free pipe outlet in a down pipe.

Endress+Hauser 45
Proline Promass F 100

Installation in down pipes


However, the following installation suggestion allows for installation in an open vertical pipeline.
Pipe restrictions or the use of an orifice with a smaller cross-section than the nominal diameter
prevent the sensor running empty while measurement is in progress.

A0028773

 20 Installation in a down pipe (e.g. for batching applications)


1 Supply tank
2 Sensor
3 Orifice plate, pipe restriction
4 Valve
5 Batching tank

DN Ø orifice plate, pipe restriction

[mm] [in] [mm] [in]

8 ³⁄₈ 6 0.24

15 ½ 10 0.40

25 1 14 0.55

40 1½ 22 0.87

50 2 28 1.10

80 3 50 1.97

100 4 65 2.60

150 6 90 3.54

250 10 150 5.91

Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the
flow direction (direction of medium flow through the piping).

Orientation Recommendation

A Vertical orientation

A0015591

1)
B Horizontal orientation, transmitter at
top Exceptions:
→  21,  47
A0015589

46 Endress+Hauser
Proline Promass F 100

Orientation Recommendation
2)
C Horizontal orientation, transmitter at
bottom Exceptions:
→  21,  47
A0015590

D Horizontal orientation, transmitter at


side
A0015592

1) Applications with low process temperatures may decrease the ambient temperature. To maintain the
minimum ambient temperature for the transmitter, this orientation is recommended.
2) Applications with high process temperatures may increase the ambient temperature. To maintain the
maximum ambient temperature for the transmitter, this orientation is recommended.

If a sensor is installed horizontally with a curved measuring tube, match the position of the sensor to
the fluid properties.

1 2
A0028774

 21 Orientation of sensor with curved measuring tube


1 Avoid this orientation for fluids with entrained solids: Risk of solids accumulating.
2 Avoid this orientation for outgassing fluids: Risk of gas accumulating.

Inlet and outlet runs No special precautions need to be taken for fittings which create turbulence, such as valves, elbows
or T-pieces, as long as no cavitation occurs →  57.

Special mounting Rupture disk


instructions
Information that is relevant to the process: (Verweisziel existiert nicht, aber @y.link.required='true').
The position of the rupture disk is indicated on a sticker beside it.
The transportation guard must be removed.
The existing connecting nozzles are not intended for the purpose of rinsing or pressure monitoring,
but instead serve as the mounting location for the rupture disk.
In the event of a failure of the rupture disk, a discharge device can be screwed onto the internal
thread of the rupture disk in order to drain off any escaping medium.

Endress+Hauser 47
Proline Promass F 100

DN 8 (!⁄#")...150 (6") DN 250 (10")

RUPTURE DISK

2 3 1 2 3

A0028903

1 Rupture disk label


2 Rupture disk with 1/2" NPT internal thread with 1" width across flat
3 Transport protection

For information on the dimensions: see the "Mechanical construction -> Accessories" section

Zero point adjustment


All measuring devices are calibrated in accordance with state-of-the-art technology. Calibration
takes place under reference conditions→  41. Therefore, a zero point adjustment in the field is
generally not required.
Experience shows that zero point adjustment is advisable only in special cases:
• To achieve maximum measuring accuracy even with low flow rates.
• Under extreme process or operating conditions (e.g. very high process temperatures or very high-
viscosity fluids).

Installing the Safety Barrier


> 22.5 > 22.5
Promass 100
(> 0.89) (> 0.89)

A0016894

 22 Minimum distance between additional Safety Barrier Promass 100 or other modules. Engineering unit
mm (in)

48 Endress+Hauser
Proline Promass F 100

Environment
Ambient temperature range Measuring device • –40 to +60 °C (–40 to +140 °F)
• Order code for "Test, certificate", option JM:
–50 to +60 °C (–58 to +140 °F)

Safety Barrier Promass 100 –40 to +60 °C (–40 to +140 °F)

‣ If operating outdoors:
Avoid direct sunlight, particularly in warm climatic regions.

Storage temperature –40 to +80 °C (–40 to +176 °F), preferably at +20 °C (+68 °F) (standard version)
–50 to +80 °C (–58 to +176 °F) (Order code for "Test, certificate", option JM)

Climate class DIN EN 60068-2-38 (test Z/AD)

Degree of protection Transmitter and sensor


• As standard: IP66/67, type 4X enclosure
• With the order code for "Sensor options", option CM: IP69 can also be ordered
• When housing is open: IP20, type 1 enclosure
• Display module: IP20, type 1 enclosure
Safety Barrier Promass 100
IP20

Vibration resistance • Oscillation, sinusoidal, following IEC 60068-2-6


• 2 to 8.4 Hz, 3.5 mm peak
• 8.4 to 2 000 Hz, 1 g peak
• Oscillation, broadband noise following IEC 60068-2-64
• 10 to 200 Hz, 0.003 g2/Hz
• 200 to 2 000 Hz, 0.001 g2/Hz
• Total: 1.54 g rms

Shock resistance Shock, half-sine according to IEC 60068-2-27


6 ms 30 g

Shock resistance Shock due to rough handling following IEC 60068-2-31

Interior cleaning • Cleaning in place (CIP)


• Sterilization in place (SIP)
Options
• Oil- and grease-free version for wetted parts, without declaration
Order code for "Service", option HA
• Oil- and grease-free version for wetted parts as per IEC/TR 60877-2.0 and BOC 50000810-4, with
declaration
Order code for "Service", option HB

Electromagnetic • Depends on the communication protocol:


compatibility (EMC) • HART, PROFIBUS DP, EtherNet/IP:
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
• Modbus RS485:
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
• PROFINET: as per IEC/EN 61326
• Complies with emission limits for industry as per EN 55011 (Class A)
• Device version with PROFIBUS DP: Complies with emission limits for industry as per EN 50170
Volume 2, IEC 61784
The following applies for PROFIBUS DP: If baud rates > 1.5 MBaud, an EMC cable entry must be
used and the cable shield must continue as far as the terminal wherever possible.
Details are provided in the Declaration of Conformity.

Endress+Hauser 49
Proline Promass F 100

Process
Medium temperature range
Standard version –50 to +150 °C (–58 to +302 °F) Order code for "Measuring tube
mat., wetted surface", option HA,
SA, SB, SC

Extended temperature version –50 to +240 °C (–58 to +464 °F) Order code for "Measuring tube
mat., wetted surface", option SD, SE,
SF, TH

Dependency of ambient temperature on medium temperature

Ta

A
B

Tm
A0031121

 23 Exemplary representation, values in the table below.


Ta Ambient temperature range
Tm Medium temperature
A Maximum permitted medium temperature Tm at Ta max = 60 °C (140 °F); higher medium temperatures Tm
require a reduced ambient temperature Ta
B Maximum permitted ambient temperature Ta for the maximum specified medium temperature Tm of the
sensor

Values for devices used in the hazardous area:


Separate Ex documentation (XA) for the device .

Not insulated Insulated

A B A B

Version Ta Tm Ta Tm Ta Tm Ta Tm

Standard version 60 °C (140 °F) 150 °C (302 °F) – – 60 °C (140 °F) 110 °C (230 °F) 55 °C (131 °F) 150 °C (302 °F)

Extended 60 °C (140 °F) 160 °C (320 °F) 55 °C (131 °F) 240 °C (464 °F) 60 °C (140 °F) 110 °C (230 °F) 50 °C (122 °F) 240 °C (464 °F)
temperature
version

Density 0 to 5 000 kg/m3 (0 to 312 lb/cf)

Pressure-temperature The following pressure/temperature diagrams apply to all pressure-bearing parts of the device and
ratings not just the process connection. The diagrams show the maximum permissible medium pressure
depending on the specific medium temperature.
Pressure-temperature curves with temperature range +151 to +240 °C (+304 to +464 °F)
exclusively for extended temperature version of measuring devices.

50 Endress+Hauser
Proline Promass F 100

Flange according to EN 1092-1 (DIN 2501)

[psi] [bar]
100
1400 PN 100
90
1200 80
1000 70
60 PN 63
800
50
600 40
PN 40
400 30
20
200
10 PN 16
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0034658-EN

 24 With flange material 1.4404 (F316/F316L), Alloy C22

Flange according to ASME B16.5

[psi] [bar]
100
1400 Class 600
90
1200 80
1000 70
60
800
50
Class 300
600 40

400 30
20
200 Class 150
10
0 0
-50 0 50 100 150 200 250[°C]

-80 0 80 160 240 320 400 480 [°F]


A0034659-EN

 25 With flange material 1.4404 (F316/F316L)

Endress+Hauser 51
Proline Promass F 100

[psi] [bar]
100 Class 600
1400
90
1200 80
1000 70
60
800
50
Class 300
600 40

400 30
20
200 Class 150
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0034660-EN

 26 With flange material Alloy C22

Flange JIS B2220

[psi] [bar]
1200 70
60 63K
800
50
600 40
40K
400 30
20
200 20K
10
10K
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0034665-EN

 27 With flange material 1.4404 (F316/F316L), Alloy C22

Flange DIN 11864-2 Form A

[psi] [bar]
50
600 40

400 30 DN 8…40
20
200
10 ≥ DN 50
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028782-EN

 28 With connection material 1.4404 (316/316L)

52 Endress+Hauser
Proline Promass F 100

Lap joint flange according to EN 1092-1 (DIN 2501)

[psi] [bar]
50
600 40
PN 40
400 30
20
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028784-EN

 29 With flange material 1.4301 (F304); wetted parts Alloy C22

Lap joint flange according to ASME B16.5

[psi] [bar]
100
1400 Class 600
90
1200 80
1000 70
60
800 Class 300
50
600 40

400 30
Class 150
20
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028785-EN

 30 With flange material 1.4301 (F304); wetted parts Alloy C22

Lap joint flange JIS B2220

[psi] [bar]
400 30
20
200 20K
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028786-EN

 31 With flange material 1.4301 (F304); wetted parts Alloy C22

Endress+Hauser 53
Proline Promass F 100

Thread DIN 11851

[psi] [bar]
50
600 40
DN 8…40
400 30
20 ≥ DN 50
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028794-EN

 32 With connection material 1.4404 (316/316L)

DIN 11851 allows for applications up to +140 °C (+284 °F) if suitable sealing materials are used.
Please take this into account when selecting seals and counterparts, as these components can limit
the pressure and temperature range.

Thread DIN 11864-1 Form A

[psi] [bar]
50
600 40
DN 8…40
400 30
20 ≥ DN 50
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028798-EN

 33 With connection material 1.4404 (316/316L)

Thread ISO 2853

[psi] [bar]
400
20
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028799-EN

 34 With connection material 1.4404 (316/316L)

54 Endress+Hauser
Proline Promass F 100

Thread SMS 1145

[psi] [bar]
400
20
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028800-EN

 35 With connection material 1.4404 (316/316L)

SMS 1145 allows for applications up to 16 bar (232 psi) if suitable sealing materials are used. Please
take this into account when selecting seals and counterparts, as these components can limit the
pressure and temperature range.

VCO

[psi] [bar]
100
1400
90
1200 80
1000 70
60
800
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0028801-EN

 36 With connection material 1.4404 (316/316L)

Tri-Clamp

[psi] [bar]
400
20
200
10
0 0
-50 0 50 100 150 200 250 [°C]

-80 0 80 160 240 320 400 480 [°F]


A0032216-EN

The clamp connections are suitable up to a maximum pressure of 16 bar (232 psi). Please observe
the operating limits of the clamp and seal used as they can be over 16 bar (232 psi). The clamp and
seal are not included in the scope of supply.

Sensor housing
For standard versions with the temperature range –50 to +150 °C (–58 to +302 °F), the sensor
housing is filled with dry nitrogen gas and protects the electronics and mechanics inside.
For all other temperature versions the sensor housing is filled with dry inert gas.
If a measuring tube fails (e.g. due to process characteristics like corrosive or abrasive fluids), the
fluid will initially be contained by the sensor housing.

Endress+Hauser 55
Proline Promass F 100

In the event of a tube failure, the pressure level inside the sensor housing will rise according to the
operating process pressure. If the user judges that the sensor housing burst pressure does not
provide an adequate safety margin, the device can be fitted with a rupture disk. This prevents
excessively high pressure from forming inside the sensor housing. Therefore, the use of a rupture
disk is strongly recommended in applications involving high gas pressures, and particularly in
applications in which the process pressure is greater than 2/3 of the sensor housing burst pressure.
If there is a need to drain the leaking medium into a discharge device, the sensor should be fitted
with a rupture disk. Connect the discharge to the additional threaded connection →  78.

If the sensor is to be purged with gas (gas detection), it should be equipped with purge connections.
Do not open the purge connections unless the containment can be filled immediately with a
dry, inert gas. Use only low pressure to purge.
Maximum pressure:
• DN 08 to 150 (3/8 to 6"): 5 bar (72.5 psi)
• DN 250 (10"):
• Medium temperature ≤ 100 °C (212 °F): 5 bar (72.5 psi)
• Medium temperature > 100 °C (212 °F): 3 bar (43.5 psi)

Burst pressure of the sensor housing

The following sensor housing burst pressures are only valid for standard devices and/or devices
equipped with closed purge connections (not opened/as delivered).
If a device fitted with purge connections (order code for "Sensor option", option CH "Purge
connection") is connected to the purge system, the maximum pressure is determined by the purge
system itself or by the device, depending on which component has the lower pressure classification.
If the device is fitted with a rupture disk (order code for "Sensor option", option CA "Rupture disk"), the
rupture disk trigger pressure is decisive .
The sensor housing burst pressure refers to a typical internal pressure which is reached prior to
mechanical failure of the sensor housing and which was determined during type testing. The
corresponding type test declaration can be ordered with the device (order code for "Additional
approval", option LN "Sensor housing burst pressure, type test").

DN Sensor housing burst pressure

[mm] [in] [bar] [psi]

8 ³⁄₈ 400 5 800

15 ½ 350 5 070

25 1 280 4 060

40 1½ 260 3 770

50 2 180 2 610

80 3 120 1 740

100 4 95 1 370

150 6 75 1 080

250 10 50 720

For information on the dimensions: see the "Mechanical construction" section

Rupture disk To increase the level of safety, a device version with a rupture disk with a trigger pressure of
10 to 15 bar (145 to 217.5 psi)can be used (order code for "Sensor option", option CA "rupture disk").
The use of rupture disks cannot be combined with the separately available heating jacket.
For information on the dimensions: see the "Mechanical construction" section (accessories) →  78

56 Endress+Hauser
Proline Promass F 100

Flow limit Select the nominal diameter by optimizing between the required flow range and permissible pressure
loss.
For an overview of the full scale values for the measuring range, see the "Measuring range"
section →  8
• The minimum recommended full scale value is approx. 1/20 of the maximum full scale value
• In most applications, 20 to 50 % of the maximum full scale value can be considered ideal
• A low full scale value must be selected for abrasive media (such as liquids with entrained solids):
flow velocity < 1 m/s (< 3 ft/s).
• For gas measurement the following rules apply:
• The flow velocity in the measuring tubes should not exceed half the sound velocity (0.5 Mach).
• The maximum mass flow depends on the density of the gas: formula →  8
To calculate the flow limit, use the Applicator sizing tool →  101

Pressure loss To calculate the pressure loss, use the Applicator sizing tool →  101

Promass F with reduced pressure loss: order code for "Sensor option", option CE "Reduced pressure
loss"

System pressure It is important that cavitation does not occur, or that gases entrained in the liquids do not outgas.
This is prevented by means of a sufficiently high system pressure.
For this reason, the following mounting locations are recommended:
• At the lowest point in a vertical pipe
• Downstream from pumps (no danger of vacuum)

A0028777

Thermal insulation In the case of some fluids, it is important to keep the heat radiated from the sensor to the
transmitter to a low level. A wide range of materials can be used for the required insulation.
The following device versions are recommended for versions with thermal insulation:
• Version with extended neck for insulation:
Order code for "Sensor option", option CG with an extended neck length of 105 mm (4.13 in).
• Extended temperature version:
Order code for "Measuring tube material", option SD, SE, SF or TH with an extended neck length of
105 mm (4.13 in).

NOTICE
Electronics overheating on account of thermal insulation!
‣ Recommended orientation: horizontal orientation, transmitter housing pointing downwards.
‣ Do not insulate the transmitter housing .
‣ Maximum permissible temperature at the lower end of the transmitter housing: 80 °C (176 °F)
‣ Thermal insulation with extended neck free: We recommend that you do not insulate the
extended neck in order to ensure optimum dissipation of heat.

A0034391

 37 Thermal insulation with extended neck free

Endress+Hauser 57
Proline Promass F 100

Heating Some fluids require suitable measures to avoid loss of heat at the sensor.
Heating options
• Electrical heating, e.g. with electric band heaters
• Via pipes carrying hot water or steam
• Via heating jackets
Heating jackets for the sensors can be ordered as accessories from Endress+Hauser. →  100

NOTICE
Danger of overheating when heating
‣ Ensure that the temperature at the lower end of the transmitter housing does not exceed
80 °C (176 °F).
‣ Ensure that sufficient convection takes place at the transmitter neck.
‣ Ensure that a sufficiently large area of the transmitter neck remains exposed. The uncovered part
serves as a radiator and protects the electronics from overheating and excessive cooling.
‣ When using in potentially explosive atmospheres, observe the information in the device-specific
Ex documentation. For detailed information on the temperature tables, see the separate
document entitled "Safety Instructions" (XA) for the device.

Vibrations The high oscillation frequency of the measuring tubes ensures that the correct operation of the
measuring system is not influenced by plant vibrations.

58 Endress+Hauser
Proline Promass F 100

Mechanical construction
Dimensions in SI units Compact version

A G

B C

K
D
L M

A0033787

Order code for "Housing", option A "Compact, aluminum, coated"


1) 1)
DN A B C D E 2) 3) F 2) 3) G K L M

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
4)
8 148 94 54 75 185 260 136 5.35 70
4)
15 148 94 54 75 185 260 136 8.30 70
4)
25 148 94 54 75 185 260 136 12.0 70
4)
40 148 94 54 105 189.5 294.5 136 17.6 79
4)
50 148 94 54 141 199.5 340.5 136 26.0 99
4)
80 148 94 54 200 219.5 419.5 136 40.5 139
4)
100 148 94 54 254 238 492 136 51.2 176
4)
150 148 94 54 378 259 637 136 68.9 218
4)
250 148 94 54 548 302.5 850.5 136 102.3 305

1) Depending on the cable gland used: values up to + 30 mm


2) With order code for "Sensor option", option CG or order code for "Measuring tube material", option SD, SE,
SF, TH: values +70 mm
3) If using a display, order code for "Display; operation", option B: values +28 mm
4) Depending on respective process connection→  61

Order code for "Housing", option B "Compact hygienic, stainless"


1) 1)
DN A B C D E 2) 3) F 2) 3) G K L M

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
4)
8 137 78 59 75 180 255 134 5.35 70
4)
15 137 78 59 75 180 255 134 8.30 70
4)
25 137 78 59 75 180 255 134 12.0 70
4)
40 137 78 59 105 184.5 289.5 134 17.6 79
4)
50 137 78 59 141 194.5 335.5 134 26.0 99
4)
80 137 78 59 200 214.5 414.5 134 40.5 139
4)
100 137 78 59 254 233 487 134 51.2 176

Endress+Hauser 59
Proline Promass F 100

1) 1)
DN A B C D E 2) 3) F 2) 3) G K L M

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
4)
150 137 78 59 378 254 632 134 68.9 218
4)
250 137 78 59 548 297.5 845.5 134 102.3 305

1) Depending on the cable gland used: values up to + 30 mm


2) With order code for "Sensor option", option CG or order code for "Measuring tube material", option SD, SE,
SF, TH: values +70 mm
3) If using a display, order code for "Display; operation", option B: values +28 mm
4) Depending on respective process connection→  61

Order code for "Housing", option C "Ultra-compact hygienic, stainless"


1) 1)
DN A B C D F 2) 3) F 2) 3) G K L M

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
4)
8 124 68 56 75 180 255 112 5.35 70
4)
15 124 68 56 75 180 255 112 8.30 70
4)
25 124 68 56 75 180 255 112 12.0 70
4)
40 124 68 56 105 184.5 289.5 112 17.6 79
4)
50 124 68 56 141 194.5 335.5 112 26.0 99
4)
80 124 68 56 200 214.5 414.5 112 40.5 139
4)
100 124 68 56 254 233 487 112 51.2 176
4)
150 124 68 56 378 254 632 112 68.9 218
4)
250 124 68 56 548 297.5 845.5 112 102.3 305

1) Depending on the cable gland used: values up to + 30 mm


2) With order code for "Sensor option", option CG or order code for "Measuring tube material", option SD, SE,
SF, TH: values +70 mm
3) If using a display, order code for "Display; operation", option B: values +14 mm
4) Depending on respective process connection→  61

60 Endress+Hauser
Proline Promass F 100

Flange connections

Fixed flange EN 1092-1, ASME B16.5, JIS B2220

C
A
B
E
D L

A0015621

Length tolerance for dimension L in mm:


• DN ≤ 100: +1.5 / –2.0
• DN ≥ 125: +3.5

Flange according to EN 1092-1 (DIN 2501): PN16


1.4404 (F316/F316L): order code for "Process connection", option D1S
Alloy C22: order code for "Process connection", option D1C

Flange with groove according to EN 1092-1 Form D (DIN 2512N): PN16


1.4404 (F316/F316L): order code for "Process connection", option D5S
Alloy C22: order code for "Process connection", option D5C

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

100 220 180 8 × ⌀18 20 107.1 1 127/1 400 1)

150 285 240 8 × ⌀22 22 159.3 1 330/1 700 1)

250 405 355 12 × ⌀26 26 260.4 1 775

Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm

1) Installation length in accordance with NAMUR recommendation NE 132 optionally available (order code
for "Process connection", option D1N or D5N (with groove))

Flange according to EN 1092-1 (DIN 2501): PN16 with reduction in nominal diameter
1.4404 (F316/F316L

DN reduction Order code for A B C D E L


[mm] to DN "Process [mm] [mm] [mm] [mm] [mm] [mm]
[mm] connection",
option

100 80 DHS 220 180 8 × ⌀18 20 107.1 874

150 100 DJS 285 240 8 × ⌀22 22 159.3 1 167

200 150 DLS 340 295 12 × ⌀22 24 206.5 1 461

Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm

Endress+Hauser 61
Proline Promass F 100

Flange according to EN 1092-1 (DIN 2501): PN 40


1.4404 (F316/F316L): order code for "Process connection", option D2S
Alloy C22: order code for "Process connection", option D2C

Flange with groove according to EN 1092-1 Form D (DIN 2512N): PN 40


1.4404 (F316/F316L): order code for "Process connection", option D6S
Alloy C22: order code for "Process connection", option D6C

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 95 65 4 × ⌀14 16 17.3 370/510 2)

15 95 65 4 × ⌀14 16 17.3 404/510 2)

25 115 85 4 × ⌀14 18 28.5 440/600 2)

40 150 110 4 × ⌀18 18 43.1 550

50 165 125 4 × ⌀18 20 54.5 715/715 2)

80 200 160 8 × ⌀18 24 82.5 840/915 2)

100 235 190 8 × ⌀22 24 107.1 1 127

150 300 250 8 × ⌀26 28 159.3 1 370

250 450 385 12 × ⌀33 38 258.8 1 845

Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm

1) DN 8 with DN 15 flanges as standard


2) Installation length in accordance with NAMUR recommendation NE 132 optionally available (order code
for "Process connection", option D2N or D6N (with groove))

Flange according to EN 1092-1 (DIN 2501): PN 40 (with DN 25 flanges)


1.4404 (F316/F316L): order code for "Process connection", option R2S

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 115 85 4 × ⌀14 18 28.5 440

15 115 85 4 × ⌀14 18 28.5 440

Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm

Flange according to EN 1092-1 (DIN 2501): PN 40 with reduction in nominal diameter


1.4404 (F316/F316L)

DN reduction Order code for A B C D E L


[mm] to DN "Process [mm] [mm] [mm] [mm] [mm] [mm]
[mm] connection",
option

50 40 DFS 165 125 4 × ⌀18 20 54.5 555

80 50 DGS 200 160 8 × ⌀18 24 82.5 840

100 80 DIS 235 190 8 × ⌀22 24 107.1 874

150 100 DKS 300 250 8 × ⌀26 28 159.3 1 167

200 150 DMS 375 320 12 × ⌀30 34 206.5 1 461

Surface roughness (flange): EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm

62 Endress+Hauser
Proline Promass F 100

Flange according to EN 1092-1 (DIN 2501): PN 63


1.4404 (F316/F316L): order code for "Process connection", option D3S
Alloy C22: order code for "Process connection", option D3C

Flange with groove according to EN 1092-1 Form D (DIN 2512N): PN 63


1.4404 (F316/F316L): order code for "Process connection", option D7S
Alloy C22: order code for "Process connection", option D7C

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

50 180 135 4 × ⌀22 26 54.5 724

80 215 170 8 × ⌀22 28 81.7 875

100 250 200 8 × ⌀26 30 106.3 1 127

150 345 280 8 × ⌀33 36 157.1 1 410

250 470 400 12 × ⌀36 46 255.4 1 885

Surface roughness (flange):


EN 1092-1 Form B1 (DIN 2526 Form C), Ra 3.2 to 12.5 µm EN 1092-1 Form B2 (DIN 2526 Form E), Ra
0.8 to 3.2 µm

Flange according to EN 1092-1 (DIN 2501): PN 100


1.4404 (F316/F316L): order code for "Process connection", option D4S
Alloy C22: order code for "Process connection", option D4C

Flange with groove according to EN 1092-1 Form D (DIN 2512N): PN 100


1.4404 (F316/F316L): order code for "Process connection", option D8S
Alloy C22: order code for "Process connection", option D8C
DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 105 75 4 × ⌀14 20 17.3 400

15 105 75 4 × ⌀14 20 17.3 420

25 140 100 4 × ⌀18 24 28.5 470

40 170 125 4 × ⌀22 26 42.5 590

50 195 145 4 × ⌀26 28 53.9 740

80 230 180 8 × ⌀26 32 80.9 885

100 265 210 8 × ⌀30 36 104.3 1 127

150 355 290 12 × ⌀33 44 154.0 1 450

Surface roughness (flange): EN 1092-1 Form B2 (DIN 2526 Form E), Ra 0.8 to 3.2 µm

1) DN 8 with DN 15 flanges as standard

Flange according to EN 1092-1 (DIN 2501): PN 100


Alloy C22: order code for "Process connection", option D4C

Flange with groove according to EN 1092-1 Form D (DIN 2512N): PN 100


Alloy C22: order code for "Process connection", option D8C

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

250 505 430 12 × ⌀39 60 248.0 1 949

Surface roughness (flange): EN 1092-1 Form B2 (DIN 2526 Form E), Ra 0.8 to 3.2 µm

Endress+Hauser 63
Proline Promass F 100

Flange according to ASME B16.5: Class 150


1.4404 (F316/F316L): order code for "Process connection", option AAS
Alloy C22: order code for "Process connection", option AAC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 90 60.3 4 × ⌀15.7 11.2 15.7 370

15 90 60.3 4 × ⌀15.7 11.2 15.7 404

25 110 79.4 4 × ⌀15.7 14.2 26.7 440

40 125 98.4 4 × ⌀15.9 15.9 40.9 550

50 150 120.7 4 × ⌀19.1 19.1 52.6 715

80 190 152.4 4 × ⌀19.1 23.9 78.0 840

100 230 190.5 8 × ⌀19.1 23.9 102.4 1 127

150 280 241.3 8 × ⌀22.4 25.4 154.2 1 398

250 405 362 12 × ⌀25.4 30.2 254.5 1 832

Surface roughness (flange): Ra 3.2 to 6.3 µm

1) DN 8 with DN 15 flanges as standard

Flange according to ASME B16.5: Class 150 with reduction in nominal diameter
1.4404 (F316/F316L)

DN reduction Order code for A B C D E L


[mm] to DN "Process [mm] [mm] [mm] [mm] [mm] [mm]
[mm] connection",
option

50 40 AHS 150 120.7 4 × ⌀19.1 19.1 52.6 550

80 50 AJS 190 152.4 4 × ⌀19.1 23.9 78.0 720

100 80 ALS 230 190.5 8 × ⌀19.1 23.9 102.4 874

150 100 ANS 280 241.3 8 × ⌀22.4 25.4 154.2 1 167

200 150 APS 345 298.5 8 × ⌀22.4 29 202.7 1 461

Surface roughness (flange): Ra 3.2 to 6.3 µm

Flange according to ASME B16.5: Class 300


1.4404 (F316/F316L): order code for "Process connection", option ABS
Alloy C22: order code for "Process connection", option ABC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 95 66.7 4 × ⌀15.7 14.2 15.7 370

15 95 66.7 4 × ⌀15.7 14.2 15.7 404

25 125 88.9 4 × ⌀19.1 17.5 26.7 440

40 155 114.3 4 × ⌀22.3 20.6 40.9 550

50 165 127 8 × ⌀19.1 22.3 52.6 715

80 210 168.3 8 × ⌀22.3 28.4 78.0 840

100 255 200 8 × ⌀22.3 31.7 102.4 1 127

150 320 269.9 12 × ⌀22.3 36.5 154.2 1 417

250 445 387.4 16 × ⌀28.4 47.4 254.5 1 863

Surface roughness (flange): Ra 3.2 to 6.3 µm

1) DN 8 with DN 15 flanges as standard

64 Endress+Hauser
Proline Promass F 100

Flange according to ASME B16.5: Class 300 with reduction in nominal diameter
1.4404 (F316/F316L)

DN reduction Order code for A B C D E L


[mm] to DN "Process [mm] [mm] [mm] [mm] [mm] [mm]
[mm] connection",
option

50 40 AIS 165 127 8 × ⌀19.1 22.3 52.6 615

80 50 AKS 210 168.3 8 × ⌀22.3 28.4 78.0 732

100 80 AMS 255 200 8 × ⌀22.3 31.7 102.4 894

150 100 AOS 320 269.9 12 × ⌀22.3 36.5 154.2 1 187

200 150 AQS 380 330.2 12 × ⌀25.4 41.7 202.7 1 461

Surface roughness (flange): Ra 3.2 to 6.3 µm

Flange according to ASME B16.5: Class 600


1.4404 (F316/F316L): order code for "Process connection", option ACS
Alloy C22: order code for "Process connection", option ACC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 95 66.7 4 × ⌀15.7 20.6 13.9 400

15 95 66.7 4 × ⌀15.7 20.6 13.9 420

25 125 88.9 4 × ⌀19.1 23.9 24.3 490

40 155 114.3 4 × ⌀22.3 28.7 38.1 600

50 165 127 8 × ⌀19.1 31.8 49.2 742

80 210 168.3 8 × ⌀22.3 38.2 73.7 900

100 275 215.9 8 × ⌀25.4 48.4 97.3 1 157

150 355 292.1 12 × ⌀28.4 47.8 154.2 1 467

250 510 431.8 16 × ⌀35.1 69.9 254.5 1 946

Surface roughness (flange): Ra 3.2 to 6.3 µm

1) DN 8 with DN 15 flanges as standard

Flange JIS B2220: 10K


1.4404 (F316/F316L): order code for "Process connection", option NDS
Alloy C22: order code for "Process connection", option NDC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

50 155 120 4 × ⌀19 16 50 715

80 185 150 8 × ⌀19 18 80 832

100 210 175 8 × ⌀19 18 100 1 127

150 280 240 8 × ⌀23 22 150 1 354

250 400 355 12 × ⌀25 24 250 1 775

Surface roughness (flange): Ra 3.2 to 6.3 µm

Endress+Hauser 65
Proline Promass F 100

Flange JIS B2220: 20K


1.4404 (F316/F316L): order code for "Process connection", option NES
Alloy C22: order code for "Process connection", option NEC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 95 70 4 × ⌀15 14 15 370

15 95 70 4 × ⌀15 14 15 404

25 125 90 4 × ⌀19 16 25 440

40 140 105 4 × ⌀19 18 40 550

50 155 120 8 × ⌀19 18 50 715

80 200 160 8 × ⌀23 22 80 832

100 225 185 8 × ⌀23 24 100 1 127

150 305 260 12 × ⌀25 28 150 1 386

250 430 380 12 × ⌀27 34 250 1 845

Surface roughness (flange): Ra 1.6 to 3.2 µm

1) DN 8 with DN 15 flanges as standard

Flange JIS B2220: 40K


1.4404 (F316/F316L): order code for "Process connection", option NGS
Alloy C22: order code for "Process connection", option NGC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 115 80 4 × ⌀19 20 15 400

15 115 80 4 × ⌀19 20 15 425

25 130 95 4 × ⌀19 22 25 485

40 160 120 4 × ⌀23 24 38 600

50 165 130 8 × ⌀19 26 50 760

80 210 170 8 × ⌀23 32 75 890

100 250 205 8 × ⌀25 36 100 1 167

150 355 295 12 × ⌀33 44 150 1 498

Surface roughness (flange): Ra 1.6 to 3.2 µm

1) DN 8 with DN 15 flanges as standard

Flange JIS B2220: 63K


1.4404 (F316/F316L): order code for "Process connection", option NHS
Alloy C22: order code for "Process connection", option NHC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 1) 120 85 4 × ⌀19 23 12 420

15 120 85 4 × ⌀19 23 12 440

25 140 100 4 × ⌀23 27 22 494

40 175 130 4 × ⌀25 32 35 620

50 185 145 8 × ⌀23 34 48 775

80 230 185 8 × ⌀25 40 73 915

100 270 220 8 × ⌀27 44 98 1 167

66 Endress+Hauser
Proline Promass F 100

Flange JIS B2220: 63K


1.4404 (F316/F316L): order code for "Process connection", option NHS
Alloy C22: order code for "Process connection", option NHC

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

150 365 305 12 × ⌀33 54 146 1 528

Surface roughness (flange): Ra 1.6 to 3.2 µm

1) DN 8 with DN 15 flanges as standard

Endress+Hauser 67
Proline Promass F 100

Fixed flange DIN 11864-2

X X

C
A
B
E
D
L

A0015627

 38 Detail X: Asymmetrical process connection; the part shown in blue is provided by the supplier.

Length tolerance for dimension L in mm:


+1.5 / –2.0

Flange DIN11864-2 Form A, for pipe according to DIN11866 series A, flat with notch
1.4404 (316/316L)
Order code for "Process connection", option KCS

DN A B C D E L
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 54 37 4 × ⌀9 10 10 387

15 59 42 4 × ⌀9 10 16 418

25 70 53 4 × ⌀9 10 26 454

40 82 65 4 × ⌀9 10 38 560

50 94 77 4 × ⌀9 10 50 720

80 133 112 8 × ⌀11 12 81 900

100 159 137 8 × ⌀11 14 100 1 127

3A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE or
Ramax = 0.38 µm: order code for "Measuring tube material", option SC, SF
Ramax = 0.38 µm electropolished: order code for "Measuring tube material", option BC

68 Endress+Hauser
Proline Promass F 100

Lap joint flange EN 1092-1, ASME B16.5, JIS B2220

C
A
B
E
F
D L

A0022221

Length tolerance for dimension L in mm:


+1.5 / –2.0

Lap joint flange according to EN 1092-1 Form D: PN 40


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option DAC

DN A B C D E F L Ldiff 1)
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 2) 95 65 4 × ⌀14 14.5 45 17.3 370 0

15 95 65 4 × ⌀14 14.5 45 17.3 404 0

25 115 85 4 × ⌀14 16.5 68 28.5 444 +4

40 150 110 4 × ⌀18 21 88 43.1 560 +10

50 165 125 4 × ⌀18 23 102 54.5 719 +4

80 200 160 8 × ⌀18 29 138 82.5 848 +8

100 235 190 8 × ⌀22 34 162 107.1 1 131 +4

Surface roughness (flange): Ra 3.2 to 12.5 µm

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
D2C)
2) DN 8 with DN 15 flanges as standard

Lap joint flange according to ASME B16.5: Class 150


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option ADC

DN A B C D E F L Ldiff 1)
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 2) 90 60.3 4 × ⌀ 15.7 15 35.1 15.7 370 0

15 90 60.3 4 × ⌀ 15.7 15 35.1 15.7 404 0

25 110 79.4 4 × ⌀ 15.7 16 50.8 26.7 440 0

40 125 98.4 4 × ⌀ 15.7 15.9 73.2 40.9 550 0

50 150 120.7 4 × ⌀ 19.1 19 91.9 52.6 715 0

80 190 152.4 4 × ⌀ 19.1 22.3 127.0 78.0 840 0

Endress+Hauser 69
Proline Promass F 100

Lap joint flange according to ASME B16.5: Class 150


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option ADC

DN A B C D E F L Ldiff 1)
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

100 230 190.5 8 × ⌀ 19.1 26 157.2 102.4 1 127 0

Surface roughness (flange): Ra 3.2 to 12.5 µm

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
AAC)
2) DN 8 with DN 15 flanges as standard

Lap joint flange according to ASME B16.5: Class 300


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option AEC

DN A B C D E F L Ldiff 1)
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 2) 95 66.7 4 × ⌀ 15.7 16.5 35.1 15.7 376 +6

15 95 66.7 4 × ⌀ 15.7 16.5 35.1 15.7 406 +2

25 125 88.9 4 × ⌀ 19.1 21.0 50.8 26.7 450 +10

40 155 114.3 4 × ⌀ 22.3 23.0 73.2 40.9 564 +14

50 165 127 8 × ⌀ 19.1 25.5 91.9 52.6 717 +2

80 210 168.3 8 × ⌀ 22.3 31.0 127.0 78.0 852.6 +12.6

100 255 200 8 × ⌀ 22.3 32.0 157.2 102.4 1 139 +12

Surface roughness (flange): Ra 3.2 to 12.5 µm

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
ABC)
2) DN 8 with DN 15 flanges as standard

Lap joint flange according to ASME B16.5: Class 600


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option AFC

DN A B C D E F L Ldiff 1)
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 2) 95 66.7 4 × ⌀ 15.7 17.0 35.1 13.9 400 0

15 95 66.7 4 × ⌀ 15.7 17.0 35.1 13.9 420 0

25 125 88.9 4 × ⌀ 19.1 21.5 50.8 24.3 490 0

40 155 114.3 4 × ⌀ 22.3 25.0 73.2 38.1 600 0

50 165 127 8 × ⌀ 19.1 28.0 91.9 49.2 742 0

80 210 168.3 8 × ⌀ 22.3 35.0 127.0 73.7 900 0

100 275 215.9 8 × ⌀ 25.4 44.0 157.2 97.3 1 167 +10

Surface roughness (flange): Ra 3.2 to 12.5 µm

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
ACC)
2) DN 8 with DN 15 flanges as standard

70 Endress+Hauser
Proline Promass F 100

Lap joint flange JIS B2220: 20K


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option NIC

DN A B C D E F L Ldiff 1)
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

8 2) 95 70 4 × ⌀ 15 14 51 15 370 0

15 95 70 4 × ⌀ 15 14 51 15 404 0

25 125 90 4 × ⌀ 19 18.5 67 25 440 0

40 140 105 4 × ⌀ 19 18.5 81 40 550 0

50 155 120 8 × ⌀ 19 23 96 50 715 0

80 200 160 8 × ⌀ 23 29 132 80 844 +12

100 225 185 8 × ⌀ 23 29 160 100 1 127 0

Surface roughness (flange): Ra 3.2 to 12.5 µm

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
NEC)
2) DN 8 with DN 15 flanges as standard

Endress+Hauser 71
Proline Promass F 100

Clamp connections

Tri-Clamp

B
L

A0015625

Length tolerance for dimension L in mm:


+1.5 / –2.0

Tri-Clamp (½"), for pipe according to DIN 11866 series C


1.4404 (316/316L)
Order code for "Process connection", option FDW

DN Clamp A B L
[mm] [in] [mm] [mm] [mm]

8 ½ 25.0 9.5 367

15 ½ 25.0 9.5 398

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE or
Ramax = 0.38 µm: order code for "Measuring tube material", option SC, SF
Ramax = 0.38 µm electropolished: order code for "Measuring tube material", option BC

Tri-Clamp ( ≥ 1"), for pipe according to DIN 11866 series C


1.4404 (316/316L)
Order code for "Process connection", option FTS
DN Clamp A B L
[mm] [in] [mm] [mm] [mm]

8 1 50.4 22.1 367

15 1 50.4 22.1 398

25 1 50.4 22.1 434

40 1½ 50.4 34.8 560

50 2 63.9 47.5 720

80 3 90.9 72.9 900

100 4 118.9 97.4 1 127

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE or
Ramax = 0.38 µm: order code for "Measuring tube material", option SC, SF
Ramax = 0.38 µm electropolished: order code for "Measuring tube material", option BC

72 Endress+Hauser
Proline Promass F 100

Threaded couplings

Thread DIN 11851, DIN11864-1, SMS 1145

A
B
L

A0015628

Length tolerance for dimension L in mm:


+1.5 / –2.0

Thread DIN 11851, for pipe according to DIN11866, series A


1.4404 (316/316L)
Order code for "Process connection", option FMW

DN A B L
[mm] [in] [mm] [mm]

8 Rd 34 × ¹⁄₈ 16 367

15 Rd 34 × ¹⁄₈ 16 398

25 Rd 52 × ¹⁄₆ 26 434

40 Rd 65 × ¹⁄₆ 38 560

50 Rd 78 × ¹⁄₆ 50 720

80 Rd 110 × ¹⁄₄ 81 900

100 Rd 130 × ¹⁄₄ 100 1 127

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE

Thread DIN11864-1 Form A, for pipe according to DIN11866, series A


1.4404 (316/316L)
Order code for "Process connection", option FLW

DN A B L
[mm] [in] [mm] [mm]

8 Rd 28 × ¹⁄₈ 10 367

15 Rd 34 × ¹⁄₈ 16 398

25 Rd 52 × ¹⁄₈ 26 434

40 Rd 65 × ¹⁄₆ 38 560

50 Rd 78 × ¹⁄₆ 50 720

80 Rd 110 × ¹⁄₄ 81 900

100 Rd 130 × ¹⁄₄ 100 1 127

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE or
Ramax = 0.38 µm: order code for "Measuring tube material", option SC, SF
Ramax = 0.38 µm electropolished: order code for "Measuring tube material", option BC

Endress+Hauser 73
Proline Promass F 100

Thread SMS 1145


1.4404 (316/316L)
Order code for "Process connection", option SCS

DN A B L
[mm] [in] [mm] [mm]

8 Rd 40 × ¹⁄₆ 22.6 367

15 Rd 40 × ¹⁄₆ 22.6 398

25 Rd 40 × ¹⁄₆ 22.6 434

40 Rd 60 × ¹⁄₆ 35.6 560

50 Rd 70 × ¹⁄₆ 48.6 720

80 Rd 98 × ¹⁄₆ 72.9 900

100 Rd 132 × ¹⁄₆ 97.6 1 127

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE

74 Endress+Hauser
Proline Promass F 100

Thread ISO 2853

A
B
L

A0015623

Length tolerance for dimension L in mm:


+1.5 / –2.0

Thread ISO 2853, for pipe according to ISO 2037


1.4404 (316/316L)
Order code for "Process connection", option JSF

DN A 1) B L
[mm] [mm] [mm] [mm]

8 37.13 22.6 367

15 37.13 22.6 398

25 37.13 22.6 434

40 52.68 35.6 560

50 64.16 48.6 720

80 91.19 72.9 900

100 118.21 97.6 1 127

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 0.76 µm: order code for "Measuring tube material", option SB, SE or
Ramax = 0.38 µm: order code for "Measuring tube material", option SC, SF
Ramax = 0.38 µm electropolished: order code for "Measuring tube material", option BC

1) Max. thread diameter as per ISO 2853 annex A

Endress+Hauser 75
Proline Promass F 100

VCO

B
L

A0015624

Length tolerance for dimension L in mm:


+1.5 / –2.0

8-VCO-4 (½")
1.4404 (316/316L)
Order code for "Process connection", option CVS

DN A B L
[mm] [in] [mm] [mm]

8 AF 1 10.2 390

12-VCO-4 (¾")
1.4404 (316/316L)
Order code for "Process connection", option CWS

DN A B L
[mm] [in] [mm] [mm]

15 AF 1½ 15.7 430

76 Endress+Hauser
Proline Promass F 100

Safety Barrier Promass 100


Top-hat rail EN 60715:
• TH 35 x 7.5
• TH 35 x 15

C
B D

A0016777

A B C D

[mm] [mm] [mm] [mm]

108 114.5 99 22.5

Endress+Hauser 77
Proline Promass F 100

Accessories

Rupture disk/purge connections

DN 8 (!⁄#")...150 (6") DN 250 (10")

1 1;2 1 1;2
45°

A
L L A

35 (1.38) ca. 75 (approx. 2.95)


SW 1"

½" NPT

½" NPT
1 2
A0028914

 39
1 Connection nipple for purge connections: order code for "Sensor options", option CH "Purge connection"
2 Connection nipple with rupture disk: order code for "Sensor option", option CA "Rupture disk"

DN A L

[mm] [mm] [mm]

8 62 216

15 62 220

25 62 260

40 67 310

50 79 452

80 101 560

100 120 684

150 141 880

250 182 380

78 Endress+Hauser
Proline Promass F 100

Dimensions in US units Compact version

A G

B C

K
D
L M

A0033787

Order code for "Housing", option A "Compact, aluminum, coated"


DN A 1) B 1) C D F 2) 3) F 2) 3) G K L M

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]
4)
³⁄₈ 5.83 3.70 2.13 2.95 7.28 10.24 5.35 0.211 2.76
4)
½ 5.83 3.70 2.13 2.95 7.28 10.24 5.35 0.33 2.76
4)
1 5.83 3.70 2.13 2.95 7.28 10.24 5.35 0.47 2.76
4)
1½ 5.83 3.70 2.13 4.13 7.46 11.59 5.35 0.69 3.11
4)
2 5.83 3.70 2.13 5.55 7.85 13.41 5.35 1.02 3.90
4)
3 5.83 3.70 2.13 7.87 8.64 16.52 5.35 1.59 5.47
4)
4 5.83 3.70 2.13 10 9.37 19.37 5.35 2.02 6.93
4)
6 5.83 3.70 2.13 14.88 10.2 25.08 5.35 2.71 8.58
4)
10 5.83 3.70 2.13 21.57 11.91 33.48 5.35 4.03 12.01

1) Depending on the cable gland used: values up to + 1.18 in


2) With order code for "Sensor option", option CG or order code for "Measuring tube material", option SD, SE,
SF, TH: values +2.76 in
3) If using a display, order code for "Display; operation", option B: values +1.1 in
4) Depending on respective process connection→  81

Order code for "Housing", option B "Compact hygienic, stainless"


DN A 1) B C D F 2) 3) F 2) 3) G K L M

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]
4)
³⁄₈ 5.39 3.07 2.32 2.95 7.09 10.04 5.28 0.211 2.76
4)
½ 5.39 3.07 2.32 2.95 7.09 10.04 5.28 0.33 2.76
4)
1 5.39 3.07 2.32 2.95 7.09 10.04 5.28 0.47 2.76
4)
1½ 5.39 3.07 2.32 4.13 7.26 11.4 5.28 0.69 3.11
4)
2 5.39 3.07 2.32 5.55 7.66 13.21 5.28 1.02 3.90
4)
3 5.39 3.07 2.32 7.87 8.44 16.32 5.28 1.59 5.47
4)
4 5.39 3.07 2.32 10 9.17 19.17 5.28 2.02 6.93

Endress+Hauser 79
Proline Promass F 100

DN A 1) B C D F 2) 3) F 2) 3) G K L M

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]
4)
6 5.39 3.07 2.32 14.88 10 24.88 5.28 2.71 8.58
4)
10 5.39 3.07 2.32 21.57 11.71 33.29 5.28 4.03 12.01

1) Depending on the cable gland used: values up to +1.18 in


2) With order code for "Sensor option", option CG or order code for "Measuring tube material", option SD, SE,
SF, TH: values +2.76 in
3) If using a display, order code for "Display; operation", option B: values +1.1 in
4) Depending on respective process connection→  81

Order code for "Housing", option C "Ultra-compact hygienic, stainless"


DN A 1) B C D F 2) 3) F 2) 3) G K L M

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]
4)
³⁄₈ 4.88 2.68 2.20 2.95 7.09 10.04 4.41 0.21 2.76
4)
½ 4.88 2.68 2.20 2.95 7.09 10.04 4.41 0.33 2.76
4)
1 4.88 2.68 2.20 2.95 7.09 10.04 4.41 0.47 2.76
4)
1½ 4.88 2.68 2.20 4.13 7.26 11.4 4.41 0.69 3.11
4)
2 4.88 2.68 2.20 5.55 7.66 13.21 4.41 1.02 3.90
4)
3 4.88 2.68 2.20 7.87 8.44 16.32 4.41 1.59 5.47
4)
4 4.88 2.68 2.20 10 9.17 19.17 4.41 2.02 6.93
4)
6 4.88 2.68 2.20 14.88 10 24.88 4.41 2.71 8.58
4)
10 4.88 2.68 2.20 21.57 11.71 33.29 4.41 4.03 12.01

1) Depending on the cable gland used: values up to +1.18 in


2) With order code for "Sensor option", option CG or order code for "Measuring tube material", option SD, SE,
SF, TH: values +2.76 in
3) If using a display, order code for "Display; operation", option B: values +1.1 in
4) Depending on respective process connection→  81

80 Endress+Hauser
Proline Promass F 100

Flange connections

Fixed flange ASME B16.5

C
A
B
E
D L

A0015621

Length tolerance for dimension L in inch:


• DN ≤ 4": +0.06 / –0.08
• DN ≥ 5": +0.14

Flange according to ASME B16.5: Class 150


1.4404 (F316/F316L): order code for "Process connection", option AAS
Alloy C22: order code for "Process connection", option AAC

DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]

³⁄₈ 1) 3.54 2.37 4 × ⌀0.62 0.44 0.62 14.57

½ 3.54 2.37 4 × ⌀0.62 0.44 0.62 15.91

1 4.33 3.13 4 × ⌀0.62 0.56 1.05 17.32

1½ 4.92 3.87 4 × ⌀0.63 0.63 1.61 21.65

2 5.91 4.75 4 × ⌀0.75 0.75 2.07 28.15

3 7.48 6.00 4 × ⌀0.75 0.94 3.07 33.07

4 9.06 7.50 8 × ⌀0.75 0.94 4.03 44.37

6 11.02 9.50 8 × ⌀0.88 1 6.07 55.04

10 15.94 14.25 12 × ⌀1.0 1.19 10.02 72.13

Surface roughness (flange): Ra 126 to 248 µin

1) DN ³⁄₈" with DN ½" flanges as standard

Flange according to ASME B16.5: Class 150 with reduction in nominal diameter
1.4404 (F316/F316L)

DN reduction Order code for A B C D E L


[in] to DN "Process [in] [in] [in] [in] [in] [in]
[in] connection",
option

2 1½ AHS 5.91 4.75 4 × ⌀0.75 0.75 2.07 21.65

3 2 AJS 7.48 6 4 × ⌀0.75 0.94 3.07 28.35

4 3 ALS 9.06 7.5 8 × ⌀0.75 0.94 4.03 34.41

6 4 ANS 11.02 9.5 8 × ⌀0.88 1 6.07 45.94

8 6 APS 13.58 11.75 8 × ⌀0.88 1.14 7.98 57.52

Surface roughness (flange): Ra 126 to 248 µin

Endress+Hauser 81
Proline Promass F 100

Flange according to ASME B16.5: Class 300


1.4404 (F316/F316L): order code for "Process connection", option ABS
Alloy C22: order code for "Process connection", option ABC

DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]

³⁄₈ 1) 3.74 2.63 4 × ⌀0.62 0.56 0.62 14.57

½ 3.74 2.63 4 × ⌀0.62 0.56 0.62 15.91

1 4.92 3.50 4 × ⌀0.75 0.69 1.05 17.32

1½ 6.10 4.50 4 × ⌀0.88 0.81 1.61 21.65

2 6.50 5.00 8 × ⌀0.75 0.88 2.07 28.15

3 8.27 6.63 8 × ⌀0.88 1.12 3.07 33.07

4 10.04 7.87 8 × ⌀0.88 1.25 4.03 44.37

6 12.6 10.63 12 × ⌀0.88 1.44 6.07 55.79

10 17.52 15.25 16 × ⌀1.12 1.87 10.02 73.35

Surface roughness (flange): Ra 126 to 248 µin

1) DN ³⁄₈" with DN ½" flanges as standard

Flange according to ASME B16.5: Class 300 with reduction in nominal diameter
1.4404 (F316/F316L)

DN reduction Order code for A B C D E L


[in] to DN "Process [in] [in] [in] [in] [in] [in]
[in] connection",
option

2 1½ AIS 6.5 5 8 × ⌀0.75 0.88 2.07 24.21

3 2 AKS 8.27 6.63 8 × ⌀0.88 1.12 3.07 28.82

4 3 AMS 10.04 7.87 8 × ⌀0.88 1.25 4.03 35.2

6 4 AOS 12.6 10.63 12 × ⌀0.88 1.44 6.07 46.73

8 6 AQS 14.96 13 12 × ⌀1 1.64 7.98 57.52

Surface roughness (flange): Ra 126 to 248 µin

Flange according to ASME B16.5: Class 600


1.4404 (F316/F316L): order code for "Process connection", option ACS
Alloy C22: order code for "Process connection", option ACC

DN A B C D E L
[in] [in] [in] [in] [in] [in] [in]

³⁄₈ 1) 3.74 2.63 4 × ⌀0.62 0.81 0.55 15.75

½ 3.74 2.63 4 × ⌀0.62 0.81 0.55 16.54

1 4.92 3.50 4 × ⌀0.75 0.94 0.96 19.29

1½ 6.10 4.50 4 × ⌀0.88 1.13 1.5 23.62

2 6.50 5.00 8 × ⌀0.75 1.25 1.94 29.21

3 8.27 6.63 8 × ⌀0.88 1.5 2.9 35.43

4 10.83 8.50 8 × ⌀1.00 1.91 3.83 45.55

6 13.98 11.50 12 × ⌀1.12 1.88 6.07 57.76

10 20.08 17.00 16 × ⌀1.38 2.75 10.02 76.61

Surface roughness (flange): Ra 126 to 248 µin

1) DN ³⁄₈" with DN ½" flanges as standard

82 Endress+Hauser
Proline Promass F 100

Lap joint flange ASME B16.5

C
A
B
E
F
D L

A0022221

Length tolerance for dimension L in inch:


+0.06 / –0.08

Lap joint flange according to ASME B16.5: Class 150


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option ADC

DN A B C D E F L Ldiff 1)
[in] [in] [in] [in] [in] [in] [in] [in] [in]

³⁄₈ 2) 3.54 2.37 4 × ⌀ 0.62 0.59 1.38 0.62 14.57 0

½ 3.54 2.37 4 × ⌀ 0.62 0.59 1.38 0.62 15.91 0

1 4.33 3.13 4 × ⌀ 0.62 0.63 2 1.05 17.32 0

1½ 4.92 3.87 4 × ⌀ 0.62 0.63 2.88 1.61 21.65 0

2 5.91 4.75 4 × ⌀ 0.75 0.75 3.62 2.07 28.15 0

3 7.48 6.00 4 × ⌀ 0.75 0.88 5 3.07 33.07 0

4 9.06 7.50 8 × ⌀ 0.75 1.02 6.19 4.03 44.37 0

Surface roughness (flange): Ra 126 to 492 µin

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
AAC)
2) DN ³⁄₈" with DN ½" flanges as standard

Lap joint flange according to ASME B16.5: Class 300


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option AEC

DN A B C D E F L Ldiff 1)
[in] [in] [in] [in] [in] [in] [in] [in] [in]

³⁄₈ 2) 3.74 2.63 4 × ⌀ 0.62 0.65 1.38 0.62 14.8 +0.23

½ 3.74 2.63 4 × ⌀ 0.62 0.65 1.38 0.62 15.98 +0.07

1 4.92 3.50 4 × ⌀ 0.75 0.83 2 1.05 17.72 +0.40

1½ 6.10 4.50 4 × ⌀ 0.88 0.91 2.88 1.61 22.2 +0.55

2 6.50 5.00 8 × ⌀ 0.75 1 3.62 2.07 28.23 +0.08

3 8.27 6.63 8 × ⌀ 0.88 1.22 5 3.07 33.57 +0.50

Endress+Hauser 83
Proline Promass F 100

Lap joint flange according to ASME B16.5: Class 300


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option AEC

DN A B C D E F L Ldiff 1)
[in] [in] [in] [in] [in] [in] [in] [in] [in]

4 10.04 7.87 8 × ⌀ 0.88 1.26 6.19 4.03 44.84 +0.47

Surface roughness (flange): Ra 126 to 492 µin

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
AAC)
2) DN ³⁄₈" with DN ½" flanges as standard

Lap joint flange according to ASME B16.5, Class 600


1.4301 (F304), wetted parts Alloy C22
Order code for "Process connection", option AFC

DN A B C D E F L Ldiff 1)
[in] [in] [in] [in] [in] [in] [in] [in] [in]

³⁄₈ 2) 3.74 2.63 4 × ⌀ 0.62 0.67 1.38 0.55 15.75 0

½ 3.74 2.63 4 × ⌀ 0.62 0.67 1.38 0.55 16.54 0

1 4.92 3.50 4 × ⌀ 0.75 0.85 2 0.96 19.29 0

1½ 6.10 4.50 4 × ⌀ 0.88 0.98 2.88 1.5 23.62 0

2 6.50 5.00 8 × ⌀ 0.75 1.1 3.62 1.94 29.21 0

3 8.27 6.63 8 × ⌀ 0.88 1.38 5 2.9 35.43 0

4 10.83 8.50 8×⌀1 1.73 6.19 3.83 45.94 +0.39

Surface roughness (flange): Ra 126 to 492 µin

1) Difference to installation length of the welding neck flange (order code for "Process connection", option
AAC)
2) DN ³⁄₈" with DN ½" flanges as standard

84 Endress+Hauser
Proline Promass F 100

Clamp connections

Tri-Clamp

B
L

A0015625

Length tolerance for dimension L in inch:


+0.06 / –0.08

Tri-Clamp (½"), DIN 11866 series C


1.4404 (316/316L)
Order code for "Process connection", option FDW

DN Clamp A B L
[in] [in] [in] [in] [in]

³⁄₈ ½ 0.98 0.37 14.4

½ ½ 0.98 0.37 15.7

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 30 µin: order code for "Measuring tube material", option SB, SE or
Ramax = 15 µin: order code for "Measuring tube material", option SC, SF
Ramax = 15 µin electropolished: order code for "Measuring tube material", option BC

Tri-Clamp ( ≥ 1"), DIN 11866 series C


1.4404 (316/316L)
Order code for "Process connection", option FTS
DN Clamp A B L
[in] [in] [in] [in] [in]

³⁄₈ 1 1.98 0.87 14.4

½ 1 1.98 0.87 15.7

1 1 1.98 0.87 17.1

1½ 1½ 1.98 1.37 22.0

2 2 2.52 1.87 28.3

3 3 3.58 2.87 35.4

4 4 4.68 3.83 44.4

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 30 µin: order code for "Measuring tube material", option SB, SE or
Ramax = 15 µin: order code for "Measuring tube material", option SC, SF
Ramax = 15 µin electropolished: order code for "Measuring tube material", option BC

Endress+Hauser 85
Proline Promass F 100

Threaded couplings

Thread SMS 1145

A
B
L

A0015628

Length tolerance for dimension L in inch:


+0.06 / –0.08

Thread SMS 1145


1.4404 (316/316L)
Order code for "Process connection", option SCS

DN A B L
[in] [in] [in] [in]

³⁄₈ Rd 40 × ¹⁄₆ 0.89 14.45

½ Rd 40 × ¹⁄₆ 0.89 15.67

1 Rd 40 × ¹⁄₆ 0.89 17.09

1½ Rd 60 × ¹⁄₆ 1.4 22.05

2 Rd 70 × ¹⁄₆ 1.91 28.35

3 Rd 98 × ¹⁄₆ 2.87 35.43

4 Rd 132 × ¹⁄₆ 3.84 44.37

3-A version available: order code for "Additional approval", option LP in conjunction with
Ramax = 30 µin: order code for "Measuring tube material", option SB, SE

86 Endress+Hauser
Proline Promass F 100

VCO

B
L

A0015624

Length tolerance for dimension L in inch:


+0.06 / –0.08

8-VCO-4 (½")
1.4404 (316/316L)
Order code for "Process connection", option CVS

DN A B L
[in] [in] [in] [in]

³⁄₈ AF 1 0.4 15.35

12-VCO-4 (¾")
1.4404 (316/316L)
Order code for "Process connection", option CWS

DN A B L
[in] [in] [in] [in]

½ AF 1½ 0.62 16.93

Safety Barrier Promass 100


Top-hat rail EN 60715:
• TH 35 x 7.5
• TH 35 x 15
A

B D

A0016777

A B C D

[in] [in] [in] [in]

4.25 4.51 3.9 0.89

Endress+Hauser 87
Proline Promass F 100

Accessories

Rupture disk/purge connections

DN 8 (!⁄#")...150 (6") DN 250 (10")

1 1;2 1 1;2
45°

A
L L A

35 (1.38) ca. 75 (approx. 2.95)


SW 1"

½" NPT

½" NPT
1 2
A0028914

1 Connection nipple for purge connections: order code for "Sensor options", option CH "Purge connection"
2 Connection nipple with rupture disk: order code for "Sensor option", option CA "Rupture disk"

DN A L

[in] [in] [in]

³⁄₈ 2.44 8.50

½ 2.44 8.66

1 2.44 10.24

1½ 2.64 12.20

2 3.11 17.78

3 3.98 22.0

4 4.72 27.0

6 5.55 34.6

10 7.17 14.96

Weight All values (weight exclusive of packaging material) refer to devices with EN/DIN PN 40 flanges.
Weight specifications including transmitter: order code for "Housing", option A "Compact, aluminum
coated".
Different values due to different transmitter versions:

Weight in SI units

DN [mm] Weight [kg]

8 9

15 10

25 12

40 17

50 28

80 53

100 94

88 Endress+Hauser
Proline Promass F 100

DN [mm] Weight [kg]

150 152

250 398

Weight in US units

DN [in] Weight [lbs]

3/8 20

½ 22

1 26

1½ 37

2 62

3 117

4 207

6 335

10 878

Safety Barrier Promass 100


49 g (1.73 ounce)

Materials Transmitter housing


• Order code for "Housing", option A "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option B "Compact, hygienic, stainless":
• Hygienic version, stainless steel 1.4301 (304)
• Optional: order code for "Sensor feature", option CC
Hygienic version, for maximum corrosion resistance: stainless steel 1.4404 (316L)
• Order code for "Housing", option C "Ultra-compact, hygienic, stainless":
• Hygienic version, stainless steel 1.4301 (304)
• Optional: order code for "Sensor feature", option CC
Hygienic version, for maximum corrosion resistance: stainless steel 1.4404 (316L)
• Window material for optional local display (→  92):
• For order code for "Housing", option A: glass
• For order code for "Housing", option B and C: plastic

Cable entries/cable glands

3
A0020640

 40 Possible cable entries/cable glands


1 Female thread M20 × 1.5
2 Cable gland M20 × 1.5
3 Adapter for cable entry with internal thread G ½" or NPT ½"

Endress+Hauser 89
Proline Promass F 100

Order code for "Housing", option A "Compact, aluminum, coated"


The various cable entries are suitable for hazardous and non-hazardous areas.

Cable entry/cable gland Material

Cable gland M20 × 1.5

Adapter for cable entry with internal thread G ½" Nickel-plated brass

Adapter for cable entry with internal thread NPT ½"

Order code for "Housing", option B "Compact hygienic, stainless"


The various cable entries are suitable for hazardous and non-hazardous areas.

Cable entry/cable gland Material

Cable gland M20 × 1.5 Stainless steel, 1.4404 (316L)

Adapter for cable entry with internal thread G ½"

Adapter for cable entry with internal thread NPT ½"

Device plug

Electrical connection Material

Plug M12x1 • Socket: Stainless steel, 1.4404 (316L)


• Contact housing: Polyamide
• Contacts: Gold-plated brass

Sensor housing
The material of the sensor housing depends on the option selected in the order code for
"Measuring tube mat., wetted surface".

Order code for "Measuring tube mat., wetted Material


surface"

Option HA, SA, SD, TH • Acid and alkali-resistant outer surface


• Stainless steel 1.4301 (304)

 "316L
With order code for "Sensor option", option CC
Sensor housing": stainless steel, 1.4404
(316L)

Option SB, SC, SE, SF • Acid and alkali-resistant outer surface


• Stainless steel 1.4301 (304)

Measuring tubes
• DN 8 to 100 (3/8…4"): stainless steel, 1.4539 (904L);
Manifold: stainless steel, 1.4404 (316/316L)
• DN 150 (6"), DN 250 (10"): stainless steel, 1.4404 (316/316L);
Manifold: stainless steel, 1.4404 (316/316L)
• DN 8 to 250 (3/8 to 10"): Alloy C22, 2.4602 (UNS N06022);
Manifold: Alloy C22, 2.4602 (UNS N06022)

90 Endress+Hauser
Proline Promass F 100

Process connections
• Flanges according to EN 1092-1 (DIN2501) / according to ASME B 16.5 / as per JIS B2220:
• Stainless steel, 1.4404 (F316/F316L)
• Alloy C22, 2.4602 (UNS N06022)
• Lap joint flanges: stainless steel, 1.4301 (F304); wetted parts Alloy C22
• All other process connections:
Stainless steel, 1.4404 (316/316L)
Available process connections→  91

Seals
Welded process connections without internal seals

Safety Barrier Promass 100


Housing: Polyamide

Process connections • Fixed flange connections:


• EN 1092-1 (DIN 2501) flange
• EN 1092-1 (DIN 2512N) flange
• Namur lengths in accordance with NE 132
• ASME B16.5 flange
• JIS B2220 flange
• DIN 11864-2 Form A flange, DIN 11866 series A, flange with notch
• Clamp connections:
Tri-Clamp (OD tubes), DIN 11866 series C
• Thread:
• DIN 11851 thread, DIN 11866 series A
• SMS 1145 thread
• ISO 2853 thread, ISO 2037
• DIN 11864-1 Form A thread, DIN 11866 series A
• VCO connections:
• 8-VCO-4
• 12-VCO-4
Process connection materials

Surface roughness All data relate to parts in contact with fluid. The following surface roughness quality can be ordered.
• Not polished
• Ramax = 0.76 µm (30 µin)
• Ramax = 0.38 µm (15 µin)
• Ramax = 0.38 µm (15 µin) electropolished

Operability
Operating concept Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Quick and safe commissioning
• Individual menus for applications
• Menu guidance with brief explanations of the individual parameter functions

Endress+Hauser 91
Proline Promass F 100

Reliable operation
• Operation in the following languages:
• Via "FieldCare", "DeviceCare" operating tool:
English, German, French, Spanish, Italian, Chinese, Japanese
• Via integrated Web browser(only available for device versions with HART, PROFIBUS DP,
PROFINET and EtherNet/IP):
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech, Swedish, Korean
• Uniform operating philosophy applied to operating tools and Web browser
• If replacing the electronic module, transfer the device configuration via the plug-in memory
(HistoROM DAT) which contains the process and measuring device data and the event logbook. No
need to reconfigure.
For devices with Modbus RS485, the data recovery function is implemented without the plug-in
memory (HistoROM DAT).
Efficient diagnostics increase measurement availability
• Troubleshooting measures can be called up via the operating tools and web browser
• Diverse simulation options
• Status indicated by several light emitting diodes (LEDs) on the electronic module in the housing
compartment

Local display A local display is only available for device versions with the following communication protocols:
HART, PROFIBUS-DP, PROFINET, EtherNet/IP
The local display is only available with the following device order code:
Order code for "Display; operation", option B: 4-line; illuminated, via communication
Display element
• 4-line liquid crystal display with 16 characters per line.
• White background lighting; switches to red in event of device errors.
• Format for displaying measured variables and status variables can be individually configured.
• Permitted ambient temperature for the display: –20 to +60 °C (–4 to +140 °F). The readability of
the display may be impaired at temperatures outside the temperature range.

Remote operation Via HART protocol


This communication interface is available in device versions with a HART output.

4 6

1 2 3 5
A0028747

 41 Options for remote operation via HART protocol


1 Control system (e.g. PLC)
2 Field Communicator 475
3 Computer with operating tool (e.g. FieldCare, AMS Device Manager, SIMATIC PDM)
4 Commubox FXA195 (USB)
5 Field Xpert SFX350 or SFX370
6 VIATOR Bluetooth modem with connecting cable
7 Transmitter

Via PROFIBUS DP network


This communication interface is available in device versions with PROFIBUS DP.

92 Endress+Hauser
Proline Promass F 100

1 2

4 4 4
A0020903

 42 Options for remote operation via PROFIBUS DP network


1 Automation system
2 Computer with PROFIBUS network card
3 PROFIBUS DP network
4 Measuring device

Via EtherNet/IP network


This communication interface is available in device versions with EtherNet/IP.

Star topology

1 2 3

5 5 5
A0032078

 43 Options for remote operation via EtherNet/IP network: star topology


1 Automation system, e.g. "RSLogix" (Rockwell Automation)
2 Workstation for measuring device operation: with Custom Add-On Profile for "RSLogix 5000" (Rockwell
Automation) or with Electronic Data Sheet (EDS)
3 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or
computer with operating tool (e.g. FieldCare, DeviceCare) with COM DTM "CDI Communication TCP/IP"
4 Ethernet switch
5 Measuring device

Via PROFINET network


This communication interface is available in device versions with PROFINET.

Endress+Hauser 93
Proline Promass F 100

Star topology

1 3 2

4 4 4
A0026545

 44 Options for remote operation via PROFINET network: star topology


1 Automation system, e.g. Simatic S7 (Siemens)
2 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or
computer with operating tool (e.g. FieldCare, DeviceCare, SIMATIC PDM) with COM DTM "CDI Communication
TCP/IP"
3 Switch, e.g. Scalance X204 (Siemens)
4 Measuring device

Service interface Via service interface (CDI-RJ45)


This communication interface is present in the following device version:
• Order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output
• Order code for "Output", option L: PROFIBUS DP
• Order code for "Output", option N: EtherNet/IP
• Order code for "Output", option R: PROFINET

HART

1
A0016926

 45 Connection for the order code for "Output", option B: 4-20 mA HART, pulse/frequency/switch output
1 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server
2 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
3 Standard Ethernet connecting cable with RJ45 plug

94 Endress+Hauser
Proline Promass F 100

PROFIBUS DP

1
A0021270

 46 Connection for order code for "Output", option L: PROFIBUS DP


1 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server
2 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
3 Standard Ethernet connecting cable with RJ45 plug

EtherNet/IP

1
A0016940

 47 Connection for order code for "Output", option N: EtherNet/IP


1 Service interface (CDI -RJ45) and EtherNet/IP interface of the measuring device with access to the integrated
Web server
2 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
3 Standard Ethernet connecting cable with RJ45 plug

Endress+Hauser 95
Proline Promass F 100

PROFINET

1
A0016940

 48 Connection for order code for "Output", option R: PROFINET


1 Service interface (CDI -RJ45) and PROFINET interface of the measuring device with access to the integrated
Web server
2 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
3 Standard Ethernet connecting cable with RJ45 plug

Via service interface (CDI)


This communication interface is present in the following device version:
Order code for "Output", option M: Modbus RS485

Modbus RS485

2 1
A0030216

1 Service interface (CDI) of measuring device


2 Commubox FXA291
3 Computer with "FieldCare" operating tool with COM DTM "CDI Communication FXA291"

Certificates and approvals


CE mark The device meets the legal requirements of the applicable EU Directives. These are listed in the
corresponding EU Declaration of Conformity along with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.

C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media
Authority (ACMA)".

96 Endress+Hauser
Proline Promass F 100

Ex approval The measuring device is certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
the nameplate.
The separate Ex documentation (XA) containing all the relevant explosion protection data is
available from your Endress+Hauser sales center.

ATEX/IECEx
Currently, the following versions for use in hazardous areas are available:

Ex ia
Category (ATEX) Type of protection

II1/2G Ex ia IIC T6…T1 Ga/Gb or Ex ia IIB T6…T1 Ga/Gb

II2G Ex ia IIC T6…T1 Gb or Ex ia IIB T6…T1 Gb

II1/2G, II2D Ex ia IIC T6…T1 Ga/Gb or Ex ia IIB T6…T1 Ga/Gb


Ex tb IIIC Txx °C Db

II2G, II2D Ex ia IIC T6…T1 Gb or Ex ia IIB T6…T1 Gb


Ex tb IIIC Txx °C Db

Ex nA
Category (ATEX) Type of protection

II3G Ex nA IIC T6…T1 Gc or Ex nA IIC T5-T1 Gc

CCSAUS

Currently, the following versions for use in hazardous areas are available:
IS (Ex i)
• Class I Division 1 Groups ABCD
• Class II Division 1 Groups EFG and Class III
NI (Ex nA)
Class I Division 2 Groups ABCD

Sanitary compatibility • 3-A approval


Only devices with the order code for "Additional approval", option LP "3A" have 3-A approval.
• EHEDG-tested
Only devices with the order code for "Additional approval", option LT "EHEDG" have been tested and
meet the requirements of the EHEDG.
To meet the requirements for EHEDG certification, the device must be used with process
connections in accordance with the EHEDG position paper entitled "Easy Cleanable Pipe Couplings
and Process Connections" (www.ehedg.org).

HART certification HART interface


The measuring device is certified and registered by the FieldComm Group. The measuring system
meets all the requirements of the following specifications:
• Certified according to HART 7
• The device can also be operated with certified devices of other manufacturers (interoperability)

Certification PROFIBUS PROFIBUS interface


The measuring device is certified and registered by the PNO (PROFIBUS User Organization
Organization). The measuring system meets all the requirements of the following specifications:
• Certified in accordance with PROFIBUS PA Profile 3.02
• The device can also be operated with certified devices of other manufacturers (interoperability)

Endress+Hauser 97
Proline Promass F 100

Certification PROFINET PROFINET interface


The measuring device is certified and registered by the PNO (PROFIBUS User Organization
Organization). The measuring system meets all the requirements of the following specifications:
• Certified according to:
• Test specification for PROFINET devices
• PROFINET Security Level 1 – Netload Class
• The device can also be operated with certified devices of other manufacturers (interoperability)

EtherNet/IP certification The measuring device is certified and registered by the ODVA (Open Device Vendor Association).
The measuring system meets all the requirements of the following specifications:
• Certified in accordance with the ODVA Conformance Test
• EtherNet/IP Performance Test
• EtherNet/IP PlugFest compliance
• The device can also be operated with certified devices of other manufacturers (interoperability)

Modbus RS485 certification The measuring device meets all the requirements of the MODBUS/TCP conformity test and has the
"MODBUS/TCP Conformance Test Policy, Version 2.0". The measuring device has successfully passed
all the test procedures carried out.

Pressure Equipment The devices can be ordered with or without a PED approval. If a device with a PED approval is
Directive required, this must be explicitly stated in the order. For devices with nominal diameters less than or
equal to DN 25 (1"), this is neither possible nor necessary.
• With the identification PED/G1/x (x = category) on the sensor nameplate, Endress+Hauser
confirms conformity with the "Essential Safety Requirements" specified in Appendix I of the
Pressure Equipment Directive 2014/68/EU.
• Devices bearing this marking (PED) are suitable for the following types of medium:
• Media in Group 1 and 2 with a vapor pressure greater than, or smaller and equal
to0.5 bar (7.3 psi)
• Unstable gases
• Devices not bearing this marking (PED) are designed and manufactured according to good
engineering practice. They meet the requirements of Article 4 paragraph 3 of the Pressure
Equipment Directive 2014/68/EU. The range of application is indicated in tables 6 to 9 in Annex II
of the Pressure Equipment Directive 2014/68/EU.

Other standards and • EN 60529


guidelines Degrees of protection provided by enclosures (IP code)
• IEC/EN 60068-2-6
Environmental influences: Test procedure - Test Fc: vibrate (sinusoidal).
• IEC/EN 60068-2-31
Environmental influences: Test procedure - Test Ec: shocks due to rough handling, primarily for
devices.
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use -
general requirements
• IEC/EN 61326
Emission in accordance with Class A requirements. Electromagnetic compatibility (EMC
requirements).
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment
• NAMUR NE 32
Data retention in the event of a power failure in field and control instruments with
microprocessors
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
• NAMUR NE 80
The application of the pressure equipment directive to process control devices
• NAMUR NE 105
Specifications for integrating fieldbus devices in engineering tools for field devices
• NAMUR NE 107
Self-monitoring and diagnosis of field devices

98 Endress+Hauser
Proline Promass F 100

• NAMUR NE 131
Requirements for field devices for standard applications
• NAMUR NE 132
Coriolis mass meter
• NACE MR0103
Materials resistant to sulfide stress cracking in corrosive petroleum refining environments.
• NACE MR0175/ISO 15156-1
Materials for use in H2S-containing Environments in Oil and Gas Production.

Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field ->
Open product page -> The "Configure" button to the right of the product image opens the Product
Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop

Application packages
Many different application packages are available to enhance the functionality of the device. Such
packages might be needed to address safety aspects or specific application requirements.
The application packages can be ordered with the device or subsequently from Endress+Hauser.
Detailed information on the order code in question is available from your local Endress+Hauser sales
center or on the product page of the Endress+Hauser website: www.endress.com.
Detailed information on the application packages:
Special Documentation for the device →  103

Heartbeat Technology Package Description

Heartbeat Verification Heartbeat Verification


+Monitoring Meets the requirement for traceable verification to DIN ISO 9001:2008 Chapter
7.6 a) "Control of monitoring and measuring equipment".
• Functional testing in the installed state without interrupting the process.
• Traceable verification results on request, including a report.
• Simple testing process via local operation or other operating interfaces.
• Clear measuring point assessment (pass/fail) with high test coverage within the
framework of manufacturer specifications.
• Extension of calibration intervals according to operator's risk assessment.
Heartbeat Monitoring
Continuously supplies data, which are characteristic of the measuring principle, to
an external condition monitoring system for the purpose of preventive
maintenance or process analysis. These data enable the operator to:
• Draw conclusions - using these data and other information - about the impact
process influences (such as corrosion, abrasion, buildup etc.) have on the
measuring performance over time.
• Schedule servicing in time.
• Monitor the process or product quality, e.g. gas pockets.

Endress+Hauser 99
Proline Promass F 100

Concentration Package Description

Concentration Calculation and outputting of fluid concentrations


The measured density is converted to the concentration of a substance of a binary
mixture using the "Concentration" application package:
• Choice of predefined fluids (e.g. various sugar solutions, acids, alkalis, salts,
ethanol etc.)
• Common or user-defined units (°Brix, °Plato, % mass, % volume, mol/l etc.) for
standard applications.
• Concentration calculation from user-defined tables.
The measured values are output via the digital and analog outputs of the device.

Special density Package Description

Special density Many applications use density as a key measured value for monitoring quality or
controlling processes. The device measures the density of the fluid as standard and
makes this value available to the control system.
The "Special Density" application package offers high-precision density
measurement over a wide density and temperature range particularly for
applications subject to varying process conditions.

Accessories
Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are
available for the device. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.

Device-specific accessories For the sensor

Accessories Description

Heating jacket Is used to stabilize the temperature of the fluids in the sensor.
Water, water vapor and other non-corrosive liquids are permitted for use as fluids.
If using oil as a heating medium, please consult with Endress+Hauser.
Heating jackets cannot be used with sensors fitted with a rupture disk.

 For details, see Operating Instructions BA00132D


Communication-specific Accessories Description
accessories
Commubox FXA195 For intrinsically safe HART communication with FieldCare via the USB interface.
HART
 For details, see "Technical Information" TI00404F
Commubox FXA291 Connects Endress+Hauser field devices with a CDI interface (= Endress+Hauser
Common Data Interface) and the USB port of a computer or laptop.

 For details, see the "Technical Information" document TI405C/07


HART Loop Converter Is used to evaluate and convert dynamic HART process variables to analog current
HMX50 signals or limit values.

 BA00371F
For details, see "Technical Information" TI00429F and Operating Instructions

Wireless HART adapter Is used for the wireless connection of field devices.
SWA70 The WirelessHART adapter can be easily integrated into field devices and existing
infrastructures, offers data protection and transmission safety and can be operated
in parallel with other wireless networks with minimum cabling complexity.

 For details, see Operating Instructions BA00061S

100 Endress+Hauser
Proline Promass F 100

Fieldgate FXA320 Gateway for the remote monitoring of connected 4 to 20 mA measuring devices via
a Web browser.

 BA00053S
For details, see "Technical Information" TI00025S and Operating Instructions

Fieldgate FXA520 Gateway for the remote diagnostics and remote configuration of connected HART
measuring devices via a Web browser.

 For details, see "Technical Information" TI00025S and Operating Instructions


BA00051S

Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices and can be used in non-hazardous areas.

 For details, see Operating Instructions BA01202S


Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices and can be used in the non-hazardous area and in the hazardous
area.

 For details, see Operating Instructions BA01202S


Service-specific accessories Accessories Description

Applicator Software for selecting and sizing Endress+Hauser measuring devices:


• Choice of measuring devices for industrial requirements
• Calculation of all the necessary data for identifying the optimum flowmeter: e.g.
nominal diameter, pressure loss, flow velocity and accuracy.
• Graphic illustration of the calculation results
• Determination of the partial order code, administration, documentation and
access to all project-related data and parameters over the entire life cycle of a
project.
Applicator is available:
• Via the Internet: https://wapps.endress.com/applicator
• As a downloadable DVD for local PC installation.

W@M W@M Life Cycle Management


Improved productivity with information at your fingertips. Data relevant to a plant
and its components is generated from the first stages of planning and during the
asset’s complete life cycle.
W@M Life Cycle Management is an open and flexible information platform with
online and on-site tools. Instant access for your staff to current, in-depth data
shortens your plant’s engineering time, speeds up procurement processes and
increases plant uptime.
Combined with the right services, W@M Life Cycle Management boosts
productivity in every phase. For more information, visit
www.endress.com/lifecyclemanagement

FieldCare FDT-based plant asset management tool from Endress+Hauser.


It can configure all smart field units in your system and helps you manage them. By
using the status information, it is also a simple but effective way of checking their
status and condition.

 For details, see Operating Instructions BA00027S and BA00059S


DeviceCare Tool for connecting and configuring Endress+Hauser field devices.

 For details, see Innovation brochure IN01047S


Commubox FXA291 Connects Endress+Hauser field devices with a CDI interface (= Endress+Hauser
Common Data Interface) and the USB port of a computer or laptop.

 For details, see "Technical Information" TI00405C

Endress+Hauser 101
Proline Promass F 100

System components Accessories Description

Memograph M graphic The Memograph M graphic data manager provides information on all the relevant
data manager measured variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on a SD card or USB stick.

 BA00247R
For details, see "Technical Information" TI00133R and Operating Instructions

iTEMP The temperature transmitters can be used in all applications and are suitable for
the measurement of gases, steam and liquids. They can be used to read in the
medium temperature.

 For details, see "Fields of Activity", FA00006T

Supplementary documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
• The W@M Device Viewer (www.endress.com/deviceviewer): Enter serial number from
nameplate
• The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
2-D matrix code (QR code) on the nameplate.

Standard documentation Brief Operating Instructions

Brief Operating Instructions for the sensor


Measuring device Documentation code

Proline Promass F KA01261D

Transmitter Brief Operating Instructions


Measuring device Documentation code

Proline Promass 100 KA01334D


KA01333D
KA01335D
KA01332D
KA01336D

Technical Information

Measuring device Documentation code

Proline Promass F 100 TI01034D

Description of Device Parameters

Measuring device Documentation code

Proline Promass 100 GP01033D

Proline Promass 100 GP01034D

Proline Promass 100 GP01035D

Proline Promass 100 GP01036D

Proline Promass 100 GP01037D

102 Endress+Hauser
Proline Promass F 100

Supplementary device- Safety Instructions


dependent documentation
Content Documentation code

ATEX/IECEx Ex i XA00159D

ATEX/IECEx Ex nA XA01029D

cCSAus IS XA00160D

INMETRO Ex i XA01219D

INMETRO Ex nA XA01220D

NEPSI Ex i XA01249D

NEPSI Ex nA XA01262D

Special Documentation

Content Documentation code

Information on the Pressure Equipment Directive SD00142D

Modbus RS485 Register Information SD00154D

Concentration measurement SD01152D

Concentration measurement SD01503D

Heartbeat Technology SD01153D

Heartbeat Technology SD01493D

Web server SD01820D

Web server SD01821D

Web server SD01822D

Web server SD01823D

Installation Instructions

Contents Comment

Installation instructions for spare part sets and accessories Documentation code: specified for each individual accessory .

Registered trademarks
HART®
Registered trademark of the FieldComm Group, Austin, Texas, USA
PROFIBUS®
Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
Modbus®
Registered trademark of SCHNEIDER AUTOMATION, INC.
EtherNet/IP™
Trademark of ODVA, Inc.
PROFINET®
Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
Microsoft®
Registered trademark of the Microsoft Corporation, Redmond, Washington, USA
TRI-CLAMP®
Registered trademark of Ladish & Co., Inc., Kenosha, USA

Endress+Hauser 103
*71505580*
71505580

www.addresses.endress.com

You might also like