Elastoliquid en 3
Elastoliquid en 3
Elastoliquid en 3
METHOD OF USE
• SUBSTRATE PREPARATION thickness of the waterproofing coating. Usually, accelerated with negative consequences regard-
Concrete surfaces to be waterproofed must be when applying two or more coats, equal to a yield of ing the adhesion of the product to the support.
clean, dry and free of dirt and powder. Any holes, 1 kg/m2, a dry film thickness of 0.4 mm is obtained, • Do not apply ELASTOLIQUID in foggy weather
fissures or cavities should have been previously filled which will be sufficient to guarantee the waterproof- or in very humid conditions which delay the
and levelled with RESISTO UNIFIX mortar; where ing of the surface. filming and drying processes. Do not apply the
necessary, falls must be constructed to allow for the product when there is a risk of imminent rainfall
complete drainage of rainwater. PRECAUTIONS which could wash away the paint which has not
• APPLICATION dried yet.
elastoliquid must be carefully mixed in its con- • Apply ELASTOLIQUID only on surfaces with a • The ELASTOLIQUID film cannot be considered
tainer before use (1). The first coat may be diluted regular water flow. Do not apply on surfaces to be a coating which can be walked on. The
with approximately 5-30% of water depending on subject to ponding. coating can be walked on only during occasional
the type and porosity of the support. • It is unadvisable to apply the product on new bi- maintenance operations.
The product can be applied by brush, roller, broom tuminous surfaces, which have just been applied • After work, clean tools with water and in the pres-
or spray (2). Surfaces to be painted must have suffi- and normally show superficial efflorescence of ence of dry product, remove with white spirits
cient falls to allow the complete drainage of rainwater hydrocarbons which creates some difficulties for or hot water.
which would otherwise cause ponding, softening the total adhesion of the ELASTOLIQUID film.
METHOD OF USE
the film coating, seriously affecting its adhesion to • When the use of ELASTOLIQUID is envisaged
the support. To achieve good protective results it is
necessary to apply two coats of ELASTOLIQUID
on a new bituminous surface, the last layer of this
surface must have a mineral protected surface. +5°C
coating; the second coat should be applied at least • When painting old bituminous surfaces, it is MIX SPRAY BRUSH ROLLER MINIMUN
APPLICATION
24 hours after the first coat has completely dried. On necessary to remove water-soluble dust before MECHANICALLY APPLICATION APPLICATION APPLICATION TEMPERATURE
1st DIVISION
1st LINE
TECHNICAL CHARACTERISTICS
ELASTOLIQUID
Appearance Pasty liquid
Colour White RAL 9010
Grey RAL 7004
Red RAL 3009
responsibility, must establish the suitability of the product for the envisaged use.
Flammability not flammable
Storage in the original containers 12 months
The figures shown are average indicative figures relevant to current production
warning. The advice and technical information provided, is what results from our
and may be changed or updated by INDEX S.p.A at any time without previous
best knowledge regarding the properties and the use of the product. Conside
© INDEX S.p.A.