I1+I2+I3 - 10=0
𝟔𝟎 𝟒𝟎 𝟐𝟎
− + =10
𝑹𝟑 𝟐𝟎 𝟓
𝟔𝟎
− 2 + 4=10
𝑹𝟑
R3=7.5Ω
MUQuestionPapers.com
Q.P Code: 58654
(ii) Briefly describe the operation of any one type of stepper motor.
SOLUTION: Permanent magnet stepper motor: (4)
The stepper motor rotor is a permanent magnet when the current flows through the
stator winding, the stator winding to produce a vector magnetic field. The magnetic
field drives the rotor to rotate by an angle so that the pair of magnetic fields of the
rotor and the magnetic field direction of the stator are consistent. When the stator's
vector magnetic field is rotated by an angle, the rotor also rotates with the
magnetic field at an angle. Each time an electrical pulse is an input, the motor
rotates one degree further. The angular displacement it outputs is proportional to
the number of pulses input and the speed is proportional to the pulse frequency.
Change the order of winding power, the motor will reverse. Therefore, it can
control the rotation of the stepping motor by controlling the number of pulses, the
frequency and the electrical sequence of each phase winding of the motor.
(iii) Two pure circuits elements in a series connection have the following
current and applied voltage: V(t)=150sin(500t+10)v, i(t)=13.42sin(500t-53.3)A.
Find the supply frequency(in Hz) and value of circuit elements. (4)
MUQuestionPapers.com
Q.P Code: 58654
Resistance = R = 5Ω
𝟏𝟎
And XL=10 wL =10 , therefore Inductance L = = 20mH.
𝟓𝟎𝟎
(iv) A three phase, three wire, 100V system supplies a balanced delta-
connected load with per phase impedance of 20∠45 ohms. Determine the line
current drawn and active power taken by the load. (4)
SOLUTION: Given Z = 20∠45
Since it is a delta connected load therefore,
Vph = VL = 100V
𝐕𝐩𝐡 𝟏𝟎𝟎
Iph = = 𝟐𝟎∠𝟒𝟓 = 3.535∠ − 𝟒𝟓 A
𝒁
(v) Draw the phasor diagram of a single phase non ideal transformer feeding
resistive load. (4)
MUQuestionPapers.com
Q.P Code: 58654
SOLUTION:
(vi) Single phase induction motor is not self-starting . State true or false and
justify your answer. (4)
SOLUTION: In induction machine a rotating magnetic field is required to produce torque.
A rotating magnetic field can produced if we have balanced three phase supply and each phase
is electrically spaced 120 to each other OR we have required minimum two phase
BUT in single phase induction motor there is single phase supply to the stator of motor , A
SINGLE PHASE SUPPLY CANNOT PRODUCE A ROTATING MAGNETIC FIELD
BUT IT PRODUCE A PULSATING MAGNETIC FIELD WHICH DOES NOT ROTATE.
Due to this pulsating magnetic field torque cannot produce so motor is not self-start.
we can make single phase induction motor self-start by split single phase supply into two phase
supply with the help of auxilliary winding.
MUQuestionPapers.com
Q.P Code: 58654
Q2. (A) Find the current through 5Ω (IX) using superposition theorem without
using source transformation . (10)
𝟐×𝟔
Solving parallel resistors(2//6) = 1.5Ω
𝟐+𝟔
𝟏𝟎
I1= = 1.176A
𝟐+𝟓+𝟏.𝟓
(i) Only 10A current source acting alone:
(𝟐)×𝟏𝟎
Using current division rule: I2 = = 2.352A
(𝟐+𝟏.𝟓+𝟓)
(i) Only 20v voltage source acting alone:
MUQuestionPapers.com
Q.P Code: 58654
𝟐𝟎
I3 = = 2.352A
𝟏.𝟓+𝟓+𝟐
By superposition theorem the total current through 5Ω resistor by 10v, 10A & 20v
source will be,
IX = I1 + I2 + I3 = 1.176+2.352+2.352 = 5.88A
MUQuestionPapers.com
Q.P Code: 58654
Thus in this case, the maximum power will be transferred to the load when load
resistance is just equal to internal resistance of the battery.
MUQuestionPapers.com
Q.P Code: 58654
MUQuestionPapers.com
Q.P Code: 58654
Q3. (A) The open Circuit(OC) and Short Circuit(SC) tests on a 5KVA, 200/400 V, 50 Hz
single phase transformer gave the following results:
OC: 200V, 1A, 100W(lv side), SC: 15V, 10A, 85W(hv side). Draw the equivalent circuit
referred to primary and put all values. (10)
SOLUTION:
From OC test,
100
No load(or OC) power factor cosøo = = 0.5
200 ×1
E = e *Z/A
= (PФN/60) *Z/A
E = (ФZN/60)* P/A
For a wave wound machine A = 2
E = ФZNP/120 Volt
Lap wound machine A =P
E = ФZN/60 Volt
(C) Find the Root Mean Square Value (RMS) value of the following
waveform. (5)
SOLUTION:
2
For triangular waveform slope of line m= = 1
2
From o<t<2
Y = mx + c , V=1t + 0=t
From 2<t<4
MUQuestionPapers.com
Q.P Code: 58654
V= -1
4 2 4 𝑡3 8
∫0 𝑣2(t) = ∫0 𝑡2dt + ∫2 (−1)2dt = [ ]20 + [1]42 =( + 2) = 4.67
3 3
Q4. (A)With a neat circuit diagram and phasor diagram, prove that by two
wattmeter method active power and reactive power of a three phase load can
be measured. (10)
SOLUTION:
The load is considered as an inductive load, and thus, the phasor diagram of the
inductive load is drawn below.
MUQuestionPapers.com
Q.P Code: 58654
The three voltages VRN, VYN and VBN, are displaced by an angle of 120 degrees
electrical as shown in the phasor diagram. The phase current lag behind their
respective phase voltages by an angle ϕ.
Now, the current flowing through the current coil of the Wattmeter, W1 will be
given as
W1 = IR
Potential difference across the pressure or potential coil of the Wattmeter, W1 will
be
To obtain the value of VYB, reverse the phasor VBN and add it to the phasor VYN as
shown in the phasor diagram above. The phase difference between VRB and IR is
(30⁰ – ϕ)
W2 = IY
IR = IY = IB = IL and
√𝟑
W1 + W2 = VLIL(2 𝐜𝐨𝐬 𝛟)
𝟐
W1 + W2 = √𝟑VLIL𝐜𝐨𝐬 𝛟 = P ………….(1)
The above equation (1) gives the Active power absorbed by a 3 phase balanced
load.
As we know that,
W1 + W2 = √𝟑VLIL𝐜𝐨𝐬 𝛟
Now,
Pr = √𝟑 (W1 – W2)
MUQuestionPapers.com
Q.P Code: 58654
C=10µF=10× 𝟏𝟎-6=10-5
𝟏 𝟏 𝟏 𝟏
(i) The resonant frequency fo = √ = √ = 159.15Hz
𝟐𝝅 𝑳𝑪 𝟐𝝅 𝟎.𝟏×𝟏𝟎−𝟓
𝑽 𝟐𝟎𝟎
Irms = = = 10A
𝒁 𝟐𝟎
𝑾×𝑳 𝟐𝛑×𝟏𝟓𝟗.𝟏𝟓×𝟎.𝟏
(iii) Q factor = = =5
𝑹 𝟐𝟎
MUQuestionPapers.com
Q.P Code: 58654
MUQuestionPapers.com
Q.P Code: 58654
Consider a delta system that’s three corner points are A, B and C as shown in the
figure. Electrical resistance of the branch between points A and B, B and C and C
and A are R1, R2 and R3 respectively.
𝑹𝟏. (𝑹𝟐 + 𝑹𝟑 )
RAB = R1 || (R2 + R3) =
𝑹𝟏 + 𝑹𝟐 + 𝑹𝟑
Now, one star system is connected to these points A, B, and C as shown in the
figure. Three arms RA, RB and RC of the star system are connected with A, B and C
respectively. Now if we measure the resistance value between points A and B, we
will get,
RAB = RA + RB
Since the two systems are identical, resistance measured between terminals A and
B in both systems must be equal.
𝑹𝟏 .(𝑹𝟐 +𝑹𝟑 )
RA + RB = ………..(i)
𝑹𝟏 +𝑹𝟐 +𝑹𝟑
Similarly, resistance between points B and C being equal in the two systems,
𝑹𝟐 .(𝑹𝟑 +𝑹𝟏 )
RB+ RC = ……….. (ii)
𝑹𝟏 +𝑹𝟐 +𝑹𝟑
MUQuestionPapers.com
Q.P Code: 58654
And resistance between points C and A being equal in the two systems,
𝑹𝟑 .(𝑹𝟏 +𝑹𝟐 )
RC + RA = ………. (iii)
𝑹𝟏 +𝑹𝟐 +𝑹𝟑
Subtracting equations (I), (II) and (III) from equation (IV) we get,
𝑹𝟑 .𝑹𝟏
RA = ………..(v)
𝑹𝟏 + 𝑹𝟐 +𝑹𝟑
𝑹𝟏 .𝑹𝟐
RB = ………..(vi)
𝑹𝟏 + 𝑹𝟐 +𝑹𝟑
𝑹𝟐 .𝑹𝟑
RC= ………….(vii)
𝑹𝟏 + 𝑹𝟐 +𝑹𝟑
For star – delta transformation we just multiply equations (v), (VI) and (VI),
(VII) and (VII), (V) that is by doing (v) × (VI) + (VI) × (VII) + (VII) × (V) we get,
MUQuestionPapers.com
Q.P Code: 58654
𝑹𝟏 𝑹𝟐 𝑹𝟑 (𝑹𝟏 + 𝑹𝟐 +𝑹𝟑 )
=
(𝑹𝟏 + 𝑹𝟐 +𝑹𝟑 )𝟐
𝑹𝟏 𝑹𝟐 𝑹𝟑
= …….. (viii)
𝑹𝟏 + 𝑹𝟐 +𝑹𝟑
Now dividing equation (VIII) by equations (V), (VI) and equations (VII)
separately we get,
𝑹𝑨 𝑹𝑩 + 𝑹𝑩 𝑹𝑪 + 𝑹𝑪 𝑹𝑨
R2 =
𝑹𝑨
𝑹𝑨 𝑹𝑩 + 𝑹𝑩 𝑹𝑪 + 𝑹𝑪 𝑹𝑨
R3 =
𝑹𝑩
𝑹𝑨 𝑹𝑩 + 𝑹𝑩 𝑹𝑪 + 𝑹𝑪 𝑹𝑨
R1 =
𝑹𝑪
(B) In the parallel circuit, voltmeter across 3 Ω resistor reads 45V. What is the
indication on the ammeter? Also find input power factor. (10)
MUQuestionPapers.com
Q.P Code: 58654
SOLUTION:
𝟒𝟓
I1 = = 9A
𝟓
MUQuestionPapers.com
Q.P Code: 58654
To find VTH
Now using nodal analysis at V1
V2=100v
𝐕𝟏−𝐕𝟐 𝐕𝟏−𝟏𝟐𝟎 𝐕𝟏−𝟏𝟎𝟎 𝐕𝟏−𝟏𝟐𝟎
+ = + =0
𝟏𝟎 𝟏𝟎 𝟏𝟎 𝟏𝟎
𝟏𝟎×𝟏𝟎
RTH = (10//10)= = 5Ω
𝟏𝟎+𝟏𝟎
MUQuestionPapers.com
Q.P Code: 58654
(B) A 20KVA Transformer has iron loss of 450W and full load copper loss of
900W. Assume power factor of load as 0.8 lagging. Find full load and half
load efficiency of the transformer. (5)
SOLUTION: Given Wi = 450W, Wcu = 900W
At full load x = 1
(𝒙×𝒇𝒖𝒍𝒍−𝒍𝒐𝒂𝒅 𝑲𝑽𝑨×𝒑𝒇)
%ɳ = ( × 𝟏𝟎𝟎
𝒙×𝒇𝒖𝒍𝒍−𝒍𝒐𝒂𝒅 𝑲𝑽𝑨×𝒑𝒇)+𝑾𝒊 +𝒙𝟐 [𝑾𝒄𝒖 ]
(𝟏×𝟐𝟎×𝟎.𝟖)
= × 𝟏𝟎𝟎 = 92.21%
(𝟏×𝟐𝟎×𝟎.𝟖)+𝟎.𝟒𝟓+𝟏𝟐 ×𝟎.𝟗
(𝟎.𝟓×𝟐𝟎×𝟎.𝟖)
%ɳ = × 𝟏𝟎𝟎 = 83.33%
(𝟎.𝟓×𝟐𝟎×𝟎.𝟖)+𝟎.𝟒𝟓+𝟎.𝟓𝟐 ×𝟎.𝟗
MUQuestionPapers.com
Q.P Code: 58654
(C) Briefly explain the principle of operation of three phase induction motor.
What are the types of three phase induction motor? (5)
SOLUTION:
The stator and rotor are two essential parts of the motor. The stator is the stationary
part, and it carries the overlapping windings while the rotor carries the main or
field winding. The windings of the stator are equally displaced from each other by
an angle of 120°.
The induction motor is the single excited motor, i.e., the supply is applied only to
the one part, i.e., stator. The term excitation means the process of inducing the
magnetic field on the parts of the motor.
When the three phase supply is given to the stator, the rotating magnetic field
produced on it. The figure below shows the rotating magnetic field set up in the
stator.
MUQuestionPapers.com
Q.P Code: 58654
Consider that the rotating magnetic field induces in the anticlockwise direction.
The rotating magnetic field has the moving polarities. The polarities of the
magnetic field vary by concerning the positive and negative half cycle of the
supply. The change in polarities makes the magnetic field rotates.
The conductors of the rotor are stationary. This stationary conductor cut the
rotating magnetic field of the stator, and because of the electromagnetic induction,
the EMF induces in the rotor. This EMF is known as the rotor induced EMF, and
it is because of the electromagnetic induction phenomenon.
The conductors of the rotor are short-circuited either by the end rings or by the
help of the external resistance. The relative motion between the rotating magnetic
field and the rotor conductor induces the current in the rotor conductors. As the
current flows through the conductor, the flux induces on it. The direction of rotor
flux is same as that of the rotor current. Now we have two fluxes one because of
the rotor and another because of the stator. These fluxes interact each other. On
one end of the conductor the fluxes cancel each other, and on the other end, the
density of the flux is very high. Thus, the high-density flux tries to push the
conductor of rotor towards the low-density flux region. This phenomenon induces
the torque on the conductor, and this torque is known as the electromagnetic
torque.
MUQuestionPapers.com
Q.P Code: 58654
The direction of electromagnetic torque and rotating magnetic field is same. Thus,
the rotor starts rotating in the same direction as that of the rotating magnetic field.
MUQuestionPapers.com