Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Split Sistemi

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

60-140V/200/250

PKA-M SERIES
POWER INVERTER
Optional

Wi-Fi
Interface
Optional Optional Optional Optional Optional

Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PKA-M35HA(L) PKA-M50HA(L) PKA-M60KA(L) PKA-M71KA(L) PKA-M100KA(L)
Outdoor Unit PUZ-ZM35VKA PUZ-ZM50VKA PUZ-ZM60VHA PUZ-ZM71VHA PUZ-ZM100VKA PUZ-ZM100YKA
Refrigerant R32* 1

Power Source Outdoor power supply


Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 3.6 4.6 6.1 7.1 9.5 9.5
Min - Max kW 1.6 - 4.5 2.3 - 5.6 2.7 - 6.7 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4
Total Input Rated kW 0.869 1.239 1.560 1.863 2.405 2.405
EER 4.14 3.71 3.91 3.81 3.95 3.95
EEL Rank – – – – – –
Design Load kW 3.6 4.6 6.1 7.1 9.5 9.5
Annual Electricity Consumption*2 kWh/a 200 251 313 364 508 519
SEER 6.3 6.4 6.8 6.8 6.5 6.4
Energy Efficiency Class A++ A++ A++ A++ A++ A++
Heating Capacity Rated kW 4.1 5.0 7.0 8.0 11.2 11.2
(Average Min - Max kW 1.6 - 5.2 2.5 - 7.3 2.8 - 8.2 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0
Season) Total Input Rated kW 1.040 1.347 1.732 2.116 3.102 3.102
COP 3.94 3.71 4.04 3.78 3.61 3.61
EEL Rank – – – – – –
Design Load kW 2.4 3.3 4.4 4.7 7.8 7.8
Declared Capacity at reference design temperature kW 2.4 (–10°C) 3.3 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C)
at bivalent temperature kW 2.4 (–10°C) 3.3 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C)
at operation limit temperature kW 2.2 (–11°C) 3.2 (–11°C) 2.8 (–20°C) 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0
Annual Electricity Consumption*2 kWh/a 839 1115 1460 1523 2472 2472
SCOP 4.0 4.1 4.2 4.3 4.4 4.4
Energy Efficiency Class A+ A+ A+ A+ A+ A+
Operating Current (max) A 13.4 13.4 19.4 19.4 27.1 8.6
Indoor Input Rated kW 0.04 / 0.03 0.04 / 0.03 0.06 / 0.05 0.06 / 0.05 0.08 / 0.07 0.08 / 0.07
Unit Operating Current (max) A 0.40 0.40 0.43 0.43 0.57 0.57
Dimensions <Panel> H × W × D mm 295 - 898 - 249 365 - 1170 - 295
Weight <Panel> kg 13 13 21 21 21 21
Air Volume [Lo-Mid-Hi] m3/min 9 - 10.5 - 12 9 - 10.5 - 12 18 - 20 - 22 18 - 20 - 22 20 - 23 - 26 20 - 23 - 26
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 36 - 40 - 43 36 - 40 - 43 39 - 42 - 45 39 - 42 - 45 41 - 45 - 49 41 - 45 - 49
Sound Level (PWL) dB(A) 60 60 64 64 65 65
Outdoor Dimensions H×W×D mm 630 - 809 - 300 943 - 950 - 330 (+25) 1338 - 1050 - 330 (+40)
Unit Weight kg 46 46 70 70 116 123
Air Volume Cooling m3/min 45 45 55 55 110 110
Heating m3/min 45 45 55 55 110 110
Sound Level (SPL) Cooling dB(A) 44 44 47 47 49 49
Heating dB(A) 46 46 49 49 51 51
Sound Level (PWL) Cooling dB(A) 65 65 67 67 69 69
Operating Current (max) A 13.0 13.0 19.0 19.0 26.5 8.0
Breaker Size A 16 16 25 25 32 16
Ext. Diameter Liquid / Gas mm 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 55 55 100 100
Max. Height Out-In m 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –11 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 550. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 550 times higher than 1 kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. The GWP of R32 is 675 in the IPCC 4th Assessment Report.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

60-140V/200/250

PKA-M SERIES
STANDARD INVERTER
Optional

Wi-Fi
Interface
Optional Optional Optional Optional Optional

Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PKA-M100KA(L)
Outdoor Unit PUZ-M100VKA PUZ-M100YKA
Refrigerant R32*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50 400 / Three /50
Cooling Capacity Rated kW 9.5 9.5
Min - Max kW 4.0 - 10.6 4.0 - 10.6
Total Input Rated kW 2.94 2.94
EER 3.23 3.23
EEL Rank – –
Design Load kW 9.5 9.5
Annual Electricity Consumption*2 kWh/a 572 572
SEER 5.8 5.8
Energy Efficiency Class A+ A+
Heating Capacity Rated kW 11.2 11.2
(Average Min - Max kW 2.8 - 12.5 2.8 - 12.5
Season) Total Input Rated kW 3.28 3.28
COP 3.41 3.41
EEL Rank – –
Design Load kW 8.0 8.0
Declared Capacity at reference design temperature kW 6.0 (–10°C) 6.0 (–10°C)
at bivalent temperature kW 7.0 (–7°C) 7.0 (–7°C)
at operation limit temperature kW 4.5 (–15°C) 4.5 (–15°C)
Back Up Heating Capacity kW 2.0 2.0
Annual Electricity Consumption*2 kWh/a 2797 2797
SCOP 4.0 4.0
Energy Efficiency Class A+ A+
Operating Current (max) A 20.6 12.1
Indoor Input Rated kW 0.08 0.08
Unit Operating Current (max) A 0.57 0.57
Dimensions <Panel> H × W × D mm 365 - 1170 - 295 365 - 1170 - 295
Weight <Panel> kg 21 21
Air Volume [Lo-Mid-Hi] m3/min 20 - 23 - 26 20 - 23 - 26
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 41 - 45 - 49 41 - 45 - 49
Sound Level (PWL) dB(A) 65 65
Outdoor Dimensions H×W×D mm 981 - 1050 - 330 (+40) 981 - 1050 - 330 (+40)
Unit Weight kg 76 78
Air Volume Cooling m3/min 79.0 79.0
Heating m3/min 79.0 79.0
Sound Level (SPL) Cooling dB(A) 51 51
Heating dB(A) 54 54
Sound Level (PWL) Cooling dB(A) 70 70
Operating Current (max) A 20.0 11.5
Breaker Size A 32 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 55 55
Max. Height Out-In m 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 550. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 550 times higher than 1 kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. The GWP of R32 is 675 in the IPCC 4th Assessment Report.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

81

You might also like