DC Inverter

Izuru ECO II

YAC1FB9

IZURU ECO II Unit TRN/TRG-2128ZR TRN/TRG-2135ZR TRN/TRG-2156ZR TRN/TRG-2171ZR


Indoor unit reference TRN-2128ZR TRN-2135ZR TRN-2156ZR TRN-2171ZR
Outdoor unit reference TRG-2128ZR TRG-2135ZR TRG-2156ZR TRG-2171ZR
EAN code indoor unit 5205022019527 5205022019534 5205022019541 5205022019558
EAN code outdoor unit 5205022019626 5250022019633 5205022019640 5205022019657
Pdesignc kW 2.7 3.5 5.3 7.1
Pdesignh (average zone) kW 2.7 3.2 4.3 5.6
Pdesignh (warmer zone) kW 3.0 3.3 4.7 5.7
Btu/h 9212 (2730-12966) 11976 (3071-15013) 18084 (4299-22519) 24225 (6800-30200)
Cooling capacity
kW 2.70 (0.80-3.80) 3.51 (0.90-4.40) 5.30 (1.26-6.60) 7.10 (1.99-8.85)
Btu/h 10236 (3071-14501) 13000 (3071-16036) 19107 (4777-25590) 26614 (6150-32200)
Heating capacity
kW 3.00 (0.90-4.25) 3.81 (0.90-4.70) 5.60 (1.40-7.50) 7.80 (1.80-9.44)
SEER 7.5 7.1 7.6 7.0
Cooling
Cooling energy class A++ A++ A++ A++
SCOP average zone 4.2 4.1 4.3 4.2
Energy class average zone A+ A+ A+ A+
Heating
SCOP warmer zone 5.3 5.2 5.7 5.4
Energy class warmer zone A+++ A+++ A+++ A+++
Rated voltage / rated frequency / phase* V/Hz/PH 220-240/50/1 220-240/50/1 220-240/50/1 220-240/50/1
Annual electricity consumption (QCE) kWh/a 126 173 244 355
Cooling Power input** kW 0.70 0.96 1.58 2.03
Current A 3.10 4.30 7.10 9.00
Annual electricity consumption average zone (QHE) kWh/a 900 1093 1400 1867
Annual electricity consumption warmer zone (QHE) kWh/a 792 888 1154 1478
Heating
Power input** kW 0.70 0.95 1.44 2.00
Current A 3.20 4.60 6.30 9.30
Dehumidification L/h 0.80 1.40 1.90 2.40
Air flow volume (SL/L/ML/M/MH/H/SH) m3/h 390/420/440/470/540/570/610 360/420/480/540/600/650/700 460/520/570/610/680/750/850 800/850/900/950/1000/1100/1250
Sound power level of indoor unit (SL/L/ML/M/MH/H/SH) dB(A) 37/39/41/43/46/48/54 37/38/41/44/47/50/57 46/50/52/54/55/57/60 48/51/53/55/56/59/64
Sound pressure level of indoor unit (SL/L/ML/M/MH/H/SH)*** dB(A) 25/27/29/31/34/36/38 25/26/29/32/35/38/42 31/32/35/37/39/41/43 33/36/38/40/41/44/48
Sound power level of outdoor unit (HI) dB(A) 61 63 64 70
Sound pressure level of outdoor unit (HI)*** dB(A) 50 52 57 59
Unit dimensions (WxHxD) mm 845x289x209 845x289x209 970x300x224 1078x325x246
Package dimensions (WxHxD) mm 918x364x278 918x364x278 1038x305x380 1145x335x410
Indoor unit
Net/gross weight kg 10.5/12.5 11/13 13/15.5 16/19
Shielded communication cable (between IDU & ODU) qty x mm 3x1.5+T 3x1.5+T 3x1.5+T 3x1.5+T
Unit dimensions (WxHxD) mm 732x555x330 732x555x330 958x660x402 958x660x402
Package dimensions (WxHxD) mm 791x590x373 791x590x373 1029x715x453 1029x715x453
Outdoor unit
Net/gross weight kg 23.5/26 24.5/27 40.5/45 41.5/46
Power cable qty x mm 2x2.5+T 2x2.5+T 2x2.5+T 2x2.5+T
Liquid mm (inch) 6.35 (1/4'') 6.35 (1/4'') 6.35 (1/4'') 6.35 (1/4'')
Gas mm (inch) 9.53 (3/8'') 9.53 (3/8'') 12.70 (1/2'') 15.88 (5/8'')
Pipe Maximum pipe length without adding refrigerant m 5 5 5 5
Maximum pipe length with adding refrigerant m 15 15 25 25
Maximum pipe height m 10 10 10 10
Refrigerant charge (R32) g 530 570 1000 1500
Refrigerant additional charge g/m 16 16 16 40
Filter Hi density pre filter - Triple action filter (HEPA/silverion/biology sterillization) - photocatlytic
Operation temperature Cooling °C - 15 ~ 50 - 15 ~ 50 - 15 ~ 50 - 15 ~ 50
limit Heating °C - 15 ~ 30 - 15 ~ 30 - 15 ~ 30 - 15 ~ 30
Harmonised standard: EN 14511 : 2007, EN 12102 - Global Warming Potential (GWP)
Note: *The power supply is on the outdoor unit ** The technical data comply with the UNI EN 14511/2004 standard *** Measured in free field

Toyotomi Europe Sales B.V.


Huygensweg 10, 5466 AN Veghel
The Netherlands
Tel: +31 (0)413 82 02 95
www.toyotomi.eu • info@toyotomi.eu
DC Inverter
Izuru ECO II

YAC1FB9

The smartest air conditioner


eco II Combining high performance, elegant design and a host of features
IZURU ECO II DC Inverter will become your air conditioner.
Thanks to its high energy yields, it guarantees ideal temperatures
in winter or summer, with the lowest possible consumption.

Energy efficiency class A+++ Smooth start function Timer function

Ecological, non-toxic and safe Quiet mode


Turbo function
ozone-free R32 refrigerant

Save energy 'operating mode' Auto restart mode Wired controller*

Heating mode at 8°C Dehumidifaction function High density pre-filter

Remote controller
Command lock function Triple action filter
with hotel function*

Door control card* Light function Ionizer

Automatic horizontal Silver ion filter


I-SENSE function
oscillation movement

Automatic vertical Auto clean function


Wi-Fi pre-installed
oscillation movement

Anti-corrosion protection
Intelligent preheating 'SP' Self-diagnosis system 'blue fins'

Smart defrost Toyotomi Voice Control Self Clean

* Optional