Energies 12 04136
Energies 12 04136
Energies 12 04136
Article
Improving the Energy Efficiency of Petrochemical
Plant Operations: A Measurement and Verification
Case Study Using a Balanced Wave Optimizer
Man Hin Eve Chan 1 , Kar-Kit Chu 2 , Hin-Fung Chow 3 , Chi-Wing Tsang 3,4, * ,
Chi Kuen Danny Ho 5 and Shuk-Kei Ho 3
1 Faculty of Design and Environment, Technological and Higher Education Institute of Hong Kong (THEi),
Hong Kong 999077, China; evechan@vtc.edu.hk
2 Campus Management and Development Office, University of Macau, Taipa, Macau 999078, China;
garychu@um.edu.mo
3 Faculty of Science and Technology, Technological and Higher Education Institute of Hong Kong (THEi),
Hong Kong 999077, China; 160614089@stu.vtc.edu.hk (H.-F.C.); gaye.ho@hotmail.com (S.-K.H.)
4 Research Centre for Waste and Resource Management, Hong Kong 999077, China
5 Department of Supply Chain and Information Management, The Hang Seng University of Hong Kong,
Hong Kong 999077, China; dannyho@hsu.edu.hk
* Correspondence: ctsang@vtc.edu.hk
Received: 10 September 2019; Accepted: 25 October 2019; Published: 30 October 2019
Abstract: The Chinese petrochemical industry is facing pressure to meet strict targets of energy
consumption and carbon emission reductions. Water pumps are the primary equipment used in most
chemical and agrochemical industries sectors since water is commonly used for cooling and heating
purposes, but these pumps also consume a large amount of energy. Other uses of water pumps
in these industries include producing steam for heating, preparing reaction media or absorptive
reagents, rinsing products, and distilling. As for the electrical components of the water pump systems,
current technologies of variable frequency drives and superconducting transmission lines are unable
to increase the energy efficiency of these systems with a fixed load. However, the Balanced Wave
Technology (BWT) is offered as a solution to overcome these limitations. In this report, a case study
using a BWT optimizer is conducted on a closed loop water circulation system. Two BWTs are added
to the individual motor-controlled section of each pump that is being used on the switchboard.
For the first time, a detailed example was provided on how to implement option B of the International
Performance Measurement and Verification Protocol (IPMVP) in China by evaluating the performance
of BWT as an energy conservation measure. The evaluated periods included those of the baseline,
post-installation, and actual performance of the optimizers. An average saving of energy of about
10.46% is recorded in a 5-week reporting period. On this basis, that annual electricity saved is
estimated to be 66,447.18 kWh, which is equivalent to the emission of 68.94 metric tons of CO2 e.
This case study demonstrates in detail how option B of IPMVP can be implemented for BWTs applied
on pumping systems. In addition to petrochemical production plants, other industries like textile
and clothing sections, which are heavy users of water and electrical energy with fixed loads in the
production processes of raw materials, fiber, yarn, and fabric, as well as textile-dyeing and final
treatment, could benefit from applying this new technology.
Keywords: Electrical Energy Reduction; Motor Driven Pump; Compton Effect; Industrial Energy
Audit; IPMVP Option B
1. Introduction
Modern society is very reliant on the different petroleum-derived products for daily life products,
as reflected in global chemical sales, which approximated €3.4 trillion in 2016 and are expected to
reach €6.3 trillion in 2030 [1]. As a rapidly growing economic and industrial powerhouse, China is the
largest global producer of various chemicals and chemical-related commodities. Its share of chemical
production accounted for nearly 40% worldwide in 2016 and is predicted to contribute to half of the
currently expanding market by 2025 [1,2]. Undoubtedly, the petrochemical industry, as one of the most
important industry pillars of the economy of China, will continue to grow. However, the production of
petrochemicals is an intensive process that involves extreme temperatures and pressures, thus resulting
in energy-intensive and capital-intensive manufacturing processes. As the largest energy user, this
sector comprised 28% of the worldwide industrial final energy consumption in 2014, and the process
of energy use accounted for 42% [3]. Hence China is determined to focus on green development in
this industry to meet its target announced at the 2015 Paris Climate Change Conference, which is
a reduction of 60%–65% in carbon intensity based on its 2005 levels by 2030 [4]. The State Council
of the People’s Republic of China established the key targets on 3 August 2016 for an 8% reduction
in energy consumption and 10% reduction in carbon dioxide (CO2 ) per ¥10,000 of industrial added
value based on the levels for the 12th Five-Year Plan (2011–2015) [5]. In addition, China intends
to invest more than 1.2% of the taxation revenues from this industry in innovative research and
development to support energy efficiency [5]. The findings of a report by the International Energy
Agency indicated that an increase in energy efficiency between 2000 and 2016 reduced global energy
use by 12% [6]. Comparatively speaking, global electricity demand in 2017, which increased by 3.1%, is
significantly higher than the 2.1% increase in global energy demand [7]. For such an energy-intensive
industry, the challenge of further carbon emission reductions cannot solely rely on the use of renewable
alternatives to replace fossil feedstocks. Consequently, increasing electrical energy efficiency in the
major energy consumption sources by introducing energy-saving technologies could be the solution to
help reduce the target gap.
Improving power factors in industrial set-ups is one way to improve energy efficiency [8], which in
turns improve the long-term economic and environmental gains to the society [9]. However, the high
cost of investment in capacitor banks is always an obstacle to their wide-spread use among the
industries [10]. A practical measure to increase energy efficiency is to minimize power loss in current
electric motor-driven systems, such as water pumps. Pumps comprise more than 20% of the total
electricity consumption in China [11]. The petrochemical industry has the highest rate of use of pumps
compared to other industries, which constitutes around 51% of total number of pumps in use [12].
In petrochemical plants, water pumps are often integrated with heat exchangers to increase heat
transfer efficiency. The electricity used by the water pump systems is the fluid power divided by the
product of all components efficiencies due to the energy loss incurred from the electrical input power,
motors, power transmission, and pumps. The energy loss from the motor pumps is assumed to be
about 40% without considering losses from the transmission lines [13]. Although the value seems
to be quite high, the reasons for the pump inefficiencies vary due to various pump subcomponent
inefficiencies. These can be due to the working fluid’s viscosity, vapor pressure and density, operating
temperature and pressure, net positive suction head, motor controller [14], electricity transmission, etc.
Most current practices for improving the efficiency of pumping systems on the electricity consumption
aspects focus on reduction of large energy losses from the mismatch between the output power of fixed
speed motors and the demanded mechanical power of the electromechanical systems. In situations
where fixed speed pumps operate in place but are not fully loaded, the use of variable frequency
drives (VFDs) could reduce energy consumption from 30%–50% [12,15,16]. VFDs can ramp up and
down the frequency and voltage to adjust the speed so that the load of the electric motor can be
met. The generation of power that is not used and is therefore waste can be avoided. Moreover,
the operation of this speed-controlled system would require a considerable amount of energy itself.
If the flow rate cannot be varied nor reduced, this application will, in turn, incur more energy loss and
Energies 2019, 12, 4136 3 of 14
impose higher costs to maintain a constant output system [12,17]. Other methods such as impeller
trimming, replacing with pumps with smaller loads, or switching off extra pumps [18] do not offer a
holistic approach to reducing the overall energy consumption. To address this particular problem,
optimization of the system with alternative technology for electrical input power could be realized by
using Balanced Wave Technology (BWT) which could provide noticeable energy reductions to systems
with both variable and fixed loads It is expected that BWT will be particularly applicable to systems
with fixed loads, such as the water pump system used in petrochemical plants, since it may take a
shorter induction period and reach stable conditions as soon as possible. Therefore, a water pump
system for providing process water to a catalytic reactor is chosen as a demonstration in this case
study. Besides applicability, the more serious problem is the substantial energy losses incurred by the
power distribution network that provides electricity from the substations to the loads. The energy
losses from power lines have been underestimated at around 3%, which is the same as those from
fuel pipes, but the distribution losses from fuel pipes and electricity lines have been reported to be as
high as 10%–40% in the manufacturing and mining sectors in the United States [13]. The electricity
transmission losses are primarily caused by the electrical resistance of the conductor lines, in which
the resistance comes from the friction of electrons that bump into the atoms, which prevents electron
transfer capability. The cables that carry a higher current, sustain more heat through resistive losses
because of the Joule effect which thereby causes higher energy loss. Even though the correct cable size
can minimize the loss, some inherently technical losses in the form of heat and noise occur when the
system is energized. Thus, BWT could provide an energy saving options as a whole, rather than to
each particular parts of the pump system, such as the motors, motor couplers, pump, valves, pipes,
and the control system [19]. Current case study reports are very limited. We are aware of a few
industrial retrofit examples with variable and fixed loads, however, few details have been revealed
including the details of auditing methodology, all parameter measurement [option B of International
Performance Measurement and Verification Protocol (IPMVP), and the system stability after switching
off the optimizer. Indeed, in order to consider BWT as one potentially popular energy conservation
measures (ECM) in future, more details need to be included.
Up to now, detailed examples on the use and performance reporting of BWT to improve energy
efficiency have remained very scarce, in particular the details of the auditing procedure and stability
during and after the test based on measurement and verification plan are rarely reported. The utilization
of economic feasible BWT to reduce resistive losses in electricity lines would be invaluable to the
petrochemical industry in China so that it would remain competitive in the global marketplace.
This case study demonstrated an example of using BWT to reduce the energy consumption of a
water pump system at a petrochemical production plant in China without significantly modifying the
existing hardware or affecting the product output. On the other hand, China still faces substantial
challenges in the area of energy saving measurement and verification. Although China has issued
national standards/protocols for energy saving calculation and guidelines for the most commonly used
energy efficiency technologies, these standards and protocols are not sufficiently detailed to provide
operational guidance to the 3rd party verifiers [20]. While the system of measurement and verification
in China is still under development [20,21], for the first time, we provided an example on how to
implement option B of the International Performance Measurement and Verification Protocol (IPMVP)
in China by evaluating the performance of BWT as the energy conservation measures. The full details
on the auditing methodology, parameter measurement, and the system stability after switching off the
optimizer are reported in this paper.
In the following parts of this report, the principle of BWT will first be briefly mentioned. Previous
case studies will then be introduced and the flaws of these reported studies will be briefly mentioned,
which are the data insufficiency and the performance instability. After the methodology is introduced,
the data acquisition process is described followed by data presentations. Finally, a concluding remark
and the future prospects of this application are discussed.
Energies 2019, 12, 4136 4 of 14
2. Methods
failed. Even if the BWTs failed, the device would immediately be isolated by the added circuit breaker,
so normal production would not be affected.
226
227 Figure 1. The
Figure 1. The water circulation system.
water circulation system.
The three main testing periods for assessment were: a baseline development, the introduction
228 2.3. Acquisition of Data
phase, and actual performance of the BWTs. The baseline period was audited for 7 days before the
229 BWTs Theweredata comparison
installed. beforedata
The baseline andwere
afterutilized
energytosaving based
evaluate on the entireof water
the effectiveness circulation
the BWTs in every
230 system.
stage andThese included
to choose the the energy
BWTs withconsumption
suitable loadofcapacity.
the two pumps
During(denoted as P1601/1
the baseline, and P1601/2
load factors of the
231 in Figure
pumps 1), the
P1601/1 andtwo flow meters
P1601/2 were atmeasuring
least 98.9%.theThe
water flow rates
equation (denoted
of load as FIC417
factor (LF) per dayand FI701 in
is expressed
232 inFigure 1), the
Equation (1).pressure meter (denoted as PI411 in Figure 1), the two thermocouples measuring the
233 temperatures of return and influent water (denoted as TI426 and i TI427 in Figure 1). A calibrated
234 meter of three-phase power analyzer Average Active
“Circutor Power (kWh
CVM-NRG96” ) installed in an individual power
was
LF(%) = × 100%, (1)
235 distribution cabinet of each in useMaximum
pump to measure the main
Active Power electrical
(kWh ) parameters. The magnitudes
236 of active power
The high (kW), reactive
LF indicated energypower
use in(kvar), apparent
the water power was
pump system (kVA), power constant.
relatively factor, load
Thefactor (%),
maximum
237 current (A),
apparent voltage
power (V), current
of P1601/1 unbalance
and P1601/2 wererate (%),kVA
52.13 and and
voltage
51.22unbalance rate (%) were
kVA for reference. generated
Then, the two
238 by the meters at 10 second intervals for 24 hours continuously. The recording data were stored at the
239 connected computer. On the same day, the factory installed two power meters of model “DTSD341-
240 Three Phase Static Multi-Function Smart Energy Meter” at the nearly same location for accurate
241 verification. All computerized data of pumps P1601/1 and P1601/2 were taken using a daily and
242 hourly mean separately and were used in the calculation consistently throughout an assessment
Energies 2019, 12, x FOR PEER REVIEW 7 of 15
264
265 Figure 2. A2.wiring
Figure connection
A wiring of BWT
connection andand
of BWT meter.
meter.
266 2.4.2.4.
DataData Manipulation
Manipulation
267 TheThe comparativeresults
comparative resultswere
were established
establishedfor
forthe stable
the operation
stable of the
operation of water pumps.
the water All adopted
pumps. All
268 data were
adopted datawithin
were 5% disparity
within betweenbetween
5% disparity the highest
the and lowest
highest water
and flow
lowest rates.flow
water The rates.
deviation
The of
269 energy data
deviation sets generated
of energy by the twoby
data sets generated contrasting models of meters
the two contrasting modelswas ±0.1%was
of meters and ±0.1%
is expressed
and is as
270 Equation (2).
expressed as Equation (2).
First set value − Second set value
First set value-Second set value
Difference (%) (%)=
= 100% )/2 × 100% (2)
Difference (First set value + Second set ×value
(First set value+Second set value)/2
(2)
The daily average unit of energy consumption per hour is calculated by Equations (3) and (4).
271 The daily average
It measured the powerunitsupply
of energy consumption
for each tonne of per
fluidhour
flowisin
calculated
the waterby Equations
pipes. (3) and (4). It of
The measurement
272 measured the power supply for each tonne of fluid flow in the water pipes. The measurement
active power was to evaluate the amount of power that the pumps required to perform the work. of
273 active
Thepower was to evaluate
measurement the amount
of reactive power wasof power that thethe
to evaluate pumps required
amount to perform
of power the work.
transferred Thethe
within
274 measurement of reactive power was to evaluate the amount of power transferred within
alternative circuit. By using both power components, the ultimate avoided energy can be computed the
275 alternative circuit. By using both power components, the ultimate avoided energy can be
by Equation (5) [30]. The given equation was abstracted from the standard of SY/T 6422-2008 for computed
specifically counting the energy saving rate after the pumps retrofit.
Average 1−hr kW
Average Active Power kWh/m3 = [Average flow rate (t/h) ÷ Average 1−hr Pressure (MPa)]
× 100%, (3)
Energies 2019, 12, 4136 8 of 14
w1 − w2 + K q ( Q 1 − Q 2 )
" #
ξb = ×100% (5)
w1 + Kq Q1
where ξb = comprehensive energy-saving rate, %;
W1 = active power before BWTs have started, kWh/m3 ;
W2 = active power after BWTs started, kWh/m3 ;
Q1 = reactive power before BWTs have started, kvarh/m3 ;
Q2 = reactive power after BWTs started, kvarh/m3 ;
Kq = reactive economic equivalent, 0.03 kW/kvar for the requirement of GB/T 12947-2006.
The logging intervals of water flow rates and pipeline pressure were 1 to 3 min, which differed
from logging intervals of energy parameters (10 s). The data sets with 1- to 3-minute intervals were
less accurate than those with 10 s intervals, while the margin of error for a sample proportion in the
final energy saving was ±1% and is defined as Equation (6).
r
p̂(1 − p̂)
Margin of error (%) = Z ×
× 100% (6)
n
where EFe = electricity-specific factor (kgCO2/kWh); Activitye = reduction of electricity consumption (kWh).
332
333
334 Figure3.3. An
Figure An overview
overview of of the
thesystem
systemperformance
performanceininthethe
testing period:
testing (a) flowrate
period: of FIC417;
(a) flowrate (b)
of FIC417;
335 flowrate
(b) of of
flowrate FI701; (c)(c)
FI701; pressure
pressureof of
PI411; (d)(d)
PI411; temperature of influent
temperature andand
of influent return water.
return water.
352
352
353
354 Figure 4. Active power of (a) P1601/1 and (b) P1601/2 related to (c) total water flow rate.
355 Instead, the reactive power dropped significantly and sharply as shown in Figure 5, and the
356 power factor reached above 0.95 when the BWTs remained on, as shown in Figure 6. The rise of power
357 factor drew less current at the same time. That was because the reactive power was being diminished.
358 The reactor power continuously bounced back and forth between the source and load causing heat
359 energy within the wire. The reduction of reactive power and improving power factor illustrated that
360 the power was being consumed more effectively. Once the BWT switched off on P1601/1, the power
361 factor slumped immediately, and the reactive power returned to its original level. This was in stark
362
353 contrast to P1601/2, where reactive power had been maintained constantly. These findings indicated
363 that the BWTs had a gradual influence on active power over a period and a consistently immediate
354
364 Figure 4. Active power of (a) P1601/1 and (b) P1601/2
effect on reactive power. P1601/2 related
related to
to (c)
(c) total
total water
water flow
flow rate.
rate.
355 Instead, the reactive power dropped significantly and sharply as shown in Figure 5, and the
356 power factor reached above 0.95 when the BWTs remained on, as shown in Figure 6. The rise of power
357 factor drew less current at the same time. That was because the reactive power was being diminished.
358 The reactor power continuously bounced back and forth between the source and load causing heat
359 energy within the wire. The reduction of reactive power and improving power factor illustrated that
360 the power was being consumed more effectively. Once the BWT switched off on P1601/1, the power
361 factor slumped immediately, and the reactive power returned to its original level. This was in stark
362 contrast to P1601/2, where reactive power had been maintained constantly. These findings indicated
363 that the BWTs had a gradual influence on active power over a period and a consistently immediate
364 effect on reactive power.
365
366 Figure5.5. Reactive
Energies 2019, 12, x FOR PEER Figure
REVIEW Reactive power
power of
of (a)
(a) P1601/1
P1601/1 and
and (b)
(b) P1601/2.
P1601/2. 12 of 15
365
366 Figure 5. Reactive power of (a) P1601/1 and (b) P1601/2.
367
368 Figure6.6. Current
Figure Current compared
compared with
with a power factor of (a) P1601/1
P1601/1 and
and (b)
(b) P1601/2.
P1601/2.
369 By using BWTs the electricity consumption was lowered, leading to a decrease in carbon
370 emission. The average baseline electricity use by the pumps was 87 kWh. The annual running time
371 was 24 hours a day, multiply a year minus 45 days’ overhaul. The 5-week avoided active power was
372 9.94% and the kWh saving was calculated using Equation (7) so the total electricity savings in a year
Energies 2019, 12, 4136 12 of 14
By using BWTs the electricity consumption was lowered, leading to a decrease in carbon emission.
The average baseline electricity use by the pumps was 87 kWh. The annual running time was 24 h a day,
multiply a year minus 45 days’ overhaul. The 5-week avoided active power was 9.94% and the kWh
saving was calculated using Equation (7) so the total electricity savings in a year was 66,447.18 kWh.
For a typical average industrial electricity cost of ¥0.6561/kWh in China, the annual potential
saving on this project was ¥43,595.99 [34]. In additon, 68,938.08 kg of CO2 emissions could be reduced
due to lower electricity usage. The emissions were estimated by Equation (8), with an electricity-specific
emission factor of 1.03748694, which accounted for the CO2 emissions per kWh of electricity consumed
in China [35].
4. Conclusions
Our experimental results demonstrated the energy saving potential of BWTs on the continuously
operated fixed speed water pumps. For the first time, we have demonstrated the use of option B
of the IPMVP to perform a comprehensive study on energy saving using BWT technology, and we
monitored all the parameters. The results were evaluated by reliable data from direct measurement
and monitoring, and the procedure was sufficiently detailed to provide operational guidance to the 3rd
party verifiers during the project implementation stage. Since pumps are one of the major sources of
energy consumption in petrochemical plants, improving pump efficiency can yield significant energy
savings, cost savings, and carbon emissions avoidance. Significantly, Balanced Wave Technology was
verified to be an energy-saving approach that was not affected by the water pressure, water flow,
and other working conditions of the petrochemical plant. An average saving of energy of about 10.46%
is recorded in a 5-week reporting period. On that basis, that annual electricity saved is estimated
to be 66,447.18 kWh, which is equivalent to the emission of 68.94 metric tons of CO2 e. In particular,
for pump P1601/2, reactive power had been maintained constantly, even it was switched off.
The technology improved the quality of currents and the conductivity of electrical circuits to
increase motors’ output power without changing operational conditions. The BWTs reduced the
reactive power generated by inductive loads prominently and hence increased the power factor.
According to the working principle and working characteristics of the BWTs, the BWTs should have
good energy saving effects for most equipment in the petrochemical plant, such as air compressors,
fans, and other common equipment driven by electric motors. Therefore, the next step will obviously
be to extend the study to other areas in the petrochemical plant to increase the overall energy savings
of the plants and to identify which operation units work best with BWT. BWTs in the petrochemical
field should be a new green energy saving approach that can help the industry to tap the potential of
energy saving in a new way.
This study demonstrates the economic and environmental benefits of BWTs with a case study
of its application in a petrochemical plant. It can be envisioned that the full potential of BWTs can
be attained in manufacturing processes that heavily rely on extensive water pump systems with
high electricity consumption. In addition to petrochemicals, other industrial sectors like textiles and
clothing, which is a heavy user of water and electrical energy in the production of raw materials,
fiber, yarn, and fabric as well as textile-dyeing and treatment processes, could benefit from applying
this new technology. Without the need for changing existing hardware and output and significant
investments, BWTs present a quick and handy way to pursue sustainable production through reduced
energy consumption. This kind of energy-saving technology is particularly relevant for developing
countries like China, which lag behind in the development of renewable energy sources, to attain
carbon reduction target in the short run without slowing down economic development.
Author Contributions: Conceptualization, K.-K.C. and C.-W.T.; Funding acquisition, C.-W.T.; Methodology,
M.H.E.C. and K.-K.C.; Supervision, K.-K.C. and C.-W.T.; Validation, H.-F.C.; Visualization, C.K.D.H.;
Writing–original draft, S.-K.H.; Review & editing, C.-W.T.
Energies 2019, 12, 4136 13 of 14
Funding: This work was fully supported by Research Grants Council (RGC) of the Hong Kong Special
Administrative Region, China (Project No.: UGC/IDS25/15) and the Research Centre of Waste and
Resource Management.
Acknowledgments: The authors acknowledge the Research Centre of Waste and Resource Management at
Technological and Higher Education Institute of Hong Kong (THEi) for administrative and technical support.
Conflicts of Interest: The authors declare no conflict of interest.
Appendix A
References
1. Hadhri, M. Facts & Figures 2017 of the European Chemical Industry; Cefic’s Facts & Figures Publications:
Brussels, Belgium, 2017; pp. 6–7.
2. Graham, L. Chinese Petchem Exports upset World Markets; ChinaOil: Hong Kong, China, 2017; pp. 1–18.
3. International Energy Agency. Tracking Clean Energy Progress 2017; International Energy Agency: Paris, France,
2017; pp. 1–116.
4. NRDC. The Road from Paris: China’s Progress toward Its Climate Pledge; NRDC: New York, NY, USA, 2017;
pp. 1–5.
5. China Government. China to Improve Petrochemical Industry; China Government: Beijing, China, 2016.
6. International Energy Agency. Energy Efficiency 2017; International Energy Agency: Paris, France, 2017;
pp. 1–143.
7. International Energy Agency. Global Energy & CO2 Status Report 2017; International Energy Agency: Paris,
France, 2018; pp. 1–15.
8. Lotsu, S.; Yoshida, Y.; Fukuda, K.; He, B. Effectiveness of a Power Factor Correction Policy in Improving the
Energy Efficiency of Large-Scale Electricity Users in Ghana. Energies 2019, 12, 2582. [CrossRef]
9. Costantini, V.; Crespi, F.; Paglialunga, E. The employment impact of private and public actions for energy
efficiency: Evidence from European industries. Energy Policy 2018, 119, 250–267. [CrossRef]
10. Adefarati, T.; Oluwole, A.S.; Olusuyi, O.; Sanusi, M.A. Economic and industrial application of power factor
improvement. Int. J. Eng. Res. Technol. 2013, 2, 1945–1955.
11. No leakage pump into the mainstream of petrochemical pumps. In Enterprise News; Ningbo Zhenguan
Electrical Co. Ltd.: Ningbo, China, 2015.
12. Fleiter, T.; Eichhammer, W. Energy Efficiency in Electric Motor Systems: Technology, Saving Potentials and Policy
Options for Developing Countries; United Nations Industrial Development Organization: Vienna, Austria,
2012; pp. 1–49.
13. U.S. Department of Energy. Energy Use, Loss and Opportunities Analysis: U.S. Manufacturing & Mining;
U.S. Department of Energy, E3M Incorporated: Washington, DC, USA, 2004; pp. 1–169.
14. United States Department of Energy. Improving Pumping System Performance—A Sourcebook for Industry;
United States Department of Energy: Washington, DC, USA, 2006.
Energies 2019, 12, 4136 14 of 14
15. Hebri, S. Variable frequency drive importance in an LPG plant: Case study. Electr. Electron. Syst. 2012, 1, 1–4.
[CrossRef]
16. Variable Speed Pumping—A Guide to Successful Applications, Executive Summary; Hydraulic Institute, Europump,
U.S. Department of Energy: Washington, DC, USA, 2004; pp. 1–22.
17. Murray, M. Total System Efficiency. In Power Transmission Engineering; Randall Publications LLC: Elk Grove
Village, IL, USA, 2010; pp. 16–23.
18. Punwassi, V. Energy Savings through Pipe Header Optimization on a Cooling Tower Pumping Station.
Energy Eng. 2016, 114, 63–76. [CrossRef]
19. Bredin, M.S. Optimization of Building and Agricultural Pumping System Energy Efficiency for Maximum
Return on Investment. Energy Eng. 2017, 114, 11–32. [CrossRef]
20. Johnson, T.M. Developing Market-Based Energy Efficiency Program in China; World Bank: Washington, DC, USA,
2017.
21. Energy Efficiency Measurement and Verification Issues and Options—An Overview of International Measurement
and Verification Experience; World Bank: Washington, DC, USA, 2013.
22. Kwon, Y.-D. Electric Power Saving Apparatus Comprising Semi-Conductor Device to Pass Energy of Infrared
Ray Synthetic Wavelength into Electric Cable Using Output Pulse Signal, Electric Circuit Board Structure for
Implementing the Apparatus, and Electric Power Saving Method. US Patent 7,373,535 B2, 13 May 2008.
23. Cho, S.-H.; Choi, M.-H.; Kwon, Y.-D.; Kim, C.-D. A study on improving electric energy result by using
composition wavelength. In Proceedings of the 3rd IEEE International Conference on Industral Informatics
(INDIN’05), Perth, WA, Australia, 19 December 2005; pp. 566–571.
24. Lee, F.Y.; Jo, H.R.; Lynch, C.S.; Pilon, L. Pyroelectric energy conversion using PLZT ceramics and the
ferroelectric–ergodic relaxor phase transition. Smart Mater. Struct. 2013, 22, 1–16. [CrossRef]
25. Yuan, H.T. Application of Energy Optimizer in Motor Energy Saving, China. 2013. Available online:
www.chinaqking.com (accessed on 5 September 2019).
26. Power Optimizer Case Study in Montreal, Canada. Power Optimizer. Available online: http://www.
poweroptimizer.com (accessed on 5 September 2019).
27. Power Optimizer Case Study in the Siam Center, Thailand. Power Optimizer. Available online: http:
//www.poweroptimizer.com (accessed on 5 September 2019).
28. Anumaka, M.C. Analysis of technical losses in electrical power system (nigerian 330 kv network as a case
study). IJRRAS 2012, 12, 320–327.
29. Comparison between E-Clean Energy Saver and Conventional Energy Controller Installation Method; One Energy
Holdings Pte Ltd.: Singapore, 2013.
30. National Energy Administration. The measuring for energy conservation effect of energy conservation
products in petroleum enterprise. In Oil and Gas Industry Standard of the People’s Republic of China; National
Development and Reform Commission: Beijing, China, 2008; pp. 1–7.
31. International Performance Measurement and Verification Protocol, Concepts and Options for Determining Energy and
Water Savings; U.S. Department of Energy Office of Scientific and Technical Information: Oak Ridge, TN,
USA, 2016; Volume 1.
32. Overview of Different Measurement and Verification (M&V) Protocols; Natural Resources Canada’s
CanmetENERGY: Québec, Canada, March 2018; pp. 1–20.
33. Harding, A.C.; Nutter, D.W. Measurement and verification of industrial equipment: Sampling interval and
data logger considerations. Energy Eng. 2016, 113, 7–33. [CrossRef]
34. Pollitt, M.G.; Yang, C.H.; Chen, H. Reforming the Chinese Electricity Supply Sector: Lessons from International
Experience; Energy Policy Research Group, University of Cambridge: Cambridge, UK, 2017; pp. 1–70.
35. Brander, M.; Sood, A.; Wylie, C.; Haughton, A.; Lovel, J. Electricity-Specific Emission Factors for Grid Electricity;
Ecometrica: Edinburgh, UK, 2011; pp. 1–22.
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access
article distributed under the terms and conditions of the Creative Commons Attribution
(CC BY) license (http://creativecommons.org/licenses/by/4.0/).