Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Reusable & Disposable Pencils: A B C DE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

ELECTROSURGERY/ELECTROCIRUGIA

REUSABLE & DISPOSABLE PENCILS F

K
A B C D E
L
CATALOG NO. FIG DESCRIPTION
ESU130316 A Rocker Switch Reusable Hand Control Pencil with disposable blade electrode with 10’ (3.05m)
double insulated silicone cord; Sterile. 10 per case
ESU031615 A Rocker Switch Reusable Hand Control Pencil with disposable blade electrode with
15’ (4.575m) double insulated silicone cord; Sterile. 10 per case
ESU130308 B CONMED® Disposable Hand-controlled Electrosurgical Pencil; with Button Switch, removable
blade electrode and 10’ (3.05m) double insulated cord; Sterile. 40 per case
ESU130309 B CONMED® Disposable Hand-controlled Electrosurgical Pencil; with Button Switch, accessory
Holster, removable blade electrode and 10’ 3.05m) double insulated cord. Sterile. 40 per case

ESU130330 B CONMED® Hand-controlled Disposable Electrosurgical Pencil; with Button Switch, removable
blade electrode and 15’ (4.575m) cord. Sterile. 40 per case
ESU130316 B Push Button Reusable Hand Control Pencil with disposable blade electrode with 10’ (3.05m)
double insulated silicone cord; Sterile. 10 per case
ESU031615 B Push Button Reusable Hand Control Pencil with disposable blade electrode with 15’ (4.575m)
double insulated silicone cord; Sterile. 10 per case

ESU916615 C Tech-Switch Reusable Pencil; Buttonswitch Electrosurgical Pencil with Flat Blade Electrode
and 15’ (4.575m) cable; Sterile. 50 per case, 25 per box
ESU166110 C Tech-Switch Reusable Pencil; Buttonswitch Electrosurgical Pencil with Flat Blade Electrode
and 15’ (4.575m) cable; Non-Sterile. 10 per case
ESU130324 D CONMED® Hand-controlled Disposable Electrosurgical Pencil; with Rocker Switch, safety
holster and 10’ (3.05m) cord; Coined blade. 40 per case

ESU130307 D CONMED® Disposable Hand-controlled Electrosurgical Pencil; with Rocker Switch, Safety
Holster, removable blade electrode and 10 (3.05m) double insulated cord; Sterile. 40 per case

ESU137659 E CONMED® Foot-controlled Disposable Electrosurgical Pencil with removable blade electrode,
safety holster and 10’ (4.575m) cord; Sterile. 40 per case

ESU138100 F CONMED® Disposable Heavy Flat Blade Electrode with Hex Hub, Sterile. 40 per case
ESU138101 G CONMED® Disposable Standard flat Blade Electrode with Hex Hub, SteriIe. 40 per case
ESU138102 H CONMED® Needle Electrode with Hex Hub; Sterile. 40 per case
ESU138103 I CONMED® 3/16” Ball Electrode with Hex Hub; Sterile 40 per case
ESU138104 J CONMED® Flat Blade Electrode; with Extended Insulation; with Hex Hub; Sterile. 40 per case
ESU138105 K CONMED® Needle Electrode; with Extended Insulation; with Hex Hub; Sterile. 40 per case
ESU138107 L CONMED® 6” Flat Blade Electrode with Hex Hub; Sterile. 40 per case
ESU1
07/06
ELECTROSURGERY/ELECTROCIRUGIA
DISPOSABLE DISPERSIVE ELECTRODES
CATALOG NO. FIG DESCRIPTION

A
ESU002349 A Adult Dispersive Dectrode, Single-Use, without Cable,
MACROLYTE Conductive Adhesive. 50 per box

B
ESU252725 B Pediatric Dispersive Electrode, Single-Use, case MACRO-
LYTE Conductive Adhesive. 50 per box

ESU022750 C Adult Dual Dispersive Electrode, Single-Use without Ca-


ble, MACROLYTE Conductive Adhesive, Compatible with
contact quality return monitors. 50 per box
C

ESU252801 D Pediatric Dual Dispersive Electrode, Single-Use without


Cable, MACROLYTE Conductive Adhesive, Compatible
with contact quality return monitors. 50 per box.

D
ESU002100 E Adult Dispersive Electrode, Single-Use, Pre-attached
10’ (3.05m) Cable, MACROLYTE Conductive Adhesive.
25 per box

ESU252200 F Pediatric Dispersive Electrode, Single-Use, Pre-attached


E 10’ (3.05m) Cable, MACROLYTE Conductive Adhesive.
25 per box

ESU502300 G lnfant Dispersive Electrode, Single-Use, Pre-attached


10’ (3.05m) Cable, MACROLYTE Conductive Adhesive.
25 per box
F

ESU402400 H Preemie Dispersive Electrode, Single-Use Pre-attached


10’ (3.05m) Cable, MACROLYTE Conductive Adhesive.
25 per box

H
ESU022204 J Adult Dual Dispersive Electrode, Single-Use Pre-
attached 10’ (3.05m) Cable, MACROLYTE Conductive
Adhesive,
Compatible with contact quality return monitors.
25 per box

I ESU220415 J Adult Dual Dispersive Electrode, Single-Use Pre-


attached 15’ (4.575m) Cable, MACROLYTE Conductive
Adhesive,
Compatible with contact quality return monitors.
25 per box
ESU252508 J Pediatric Dual Dispersive Electrode, Single-Use
Pre-attached 10’ (3.05m) Cable, MACROLYTE Conductive
J Adhesive, Compatible with contact quality return moni-
tors. 25 per box
ESU2
07/06
ELECTROSURGERY/ELECTROCIRUGIA
ESU CABLES AND ADAPTERS
CATALOG NO. FIG DESCRIPTION

ESU00B209– adapter A Patient Plate Cable or Adapter for Bard EMS 101-
B ESU00T209– cable 300, 400, 500, 102, 700, Coagatome; 3M 300

ESU00B210– adapter B Patient Plate Cable or Adapter for Erbe - all models,
ESU00T210– cable Martin-Elmed-Wolf 1708, Birtcher 737XL
C
ESU00B211– adapter C Patient Plate Cable or Adapter for Burdick SU-4
ESU00T211– cable
D
ESU00B212– adapter D Patient Plate Cable or Adapter for ACMI Wappler C-
ESU00T212– cable 263, C263RC, C-264, C350
E

ESU00B214– adapter E Patient Plate Cable or Adapter for Cameron Miller


ESU00T214– cable 10V-0
F
ESU00B216– adapter F Patient Plate Cable or Adapter for Martin-Elmed-Wolf
ESU00T216– cable 170, 170RF, 1 20 (prior to July 1972); Siemens 611
612, 617, 619
G ESU00B220– adapter G Patient Plate Cable or Adapter for Martin-Elmed-Wolf
ESU00T220– cable 600RFF, Teletom 600RF,170RF, 170, 120, 2040U

ESU00B223– adapter H Patient Plate Cable or Adapter for Martin-Elmed-Wolf


H ESU00T223– cable 20834 208300, 2093.00, 2094.00, 2353

ESU00B224– adapter I Patient Plate Cable or Adapter for Radionics - All


I ESU00T224– cable Models

ESU00B227– adapter J Patient Plate Cable or Adapter for Ritter Bovie Spe-
ESU00T227– cable cialist
J
ESU00B260– adapter K Patient Plate Cable or Adapter for Olympus; for use
ESU00T260– cable with Olympus S-P cables retrofit 1 each with CON-
K MED Adapter (red) and CONMED 1 each Single Foil
Dispersive pads.
ESU00B261– adapter L Patient Plate Adapter for Olympus; for use with Olym-
pus S-P cables retrofit 1 each with CONMED Adapter
(red) and CONMED Single Foil Dispersive pads.
L
ESU00B228– adapter M Patient Plate Cable or Adapter for Aspen - All ARM
ESU00T228– cable equipped, Valleylab - Al) REM 1 each equipped; all
Meditron; Birtcher 4400; does NOT 1 each enable
pad-to-patient contact quality monitoring. 1 each

M ESU00B229– adapter N Patient Plate Cable or Adapter for Aspen - All ARM
ESU00T229– cable equipped, VoJ[eylab - All REM 1 each equipped; en-
ables pad-to-patient contact quality 1 each monitoring

N
ESU3
07/06
ELECTROSURGERY/ELECTROCIRUGIA
ESU ADAPTERS & PARTS
CATALOG NO. FIG DESCRIPTION

ESU00B202– adapter A Patient Plate Cable or Adapter for MPI Mon it Sen-
ESU00T202– cable try
A
ESU00B204– adapter B Patient Plate Cable or Adapter for ACMI Pneu-
ESU00T204– cable montome P-i 00, P-i 01 P-200, P-200A; Birt-
cher Blendtome 750, 753, 753E, Hyfrecutter 766
ESU 799; Cameron Miller 80-8010; Meditronic
8010; 3M 600; Ritter Bantam Bovie, Model A; Sie-
B mens 614; Statham Electricator 3771 2- Bipolar
and Monopolar;
Valleylab except REM Equipped and Surgistat
ESUB204SS– C Patient Plate Cable or Adapter for Valleylab Sur-
adapter gistat (Non-REM Equipped)
ESUT204SS– cable
C
ESU00B205– adapter D Patient Plate Cable or Adapter for ACMI Wappler
ESU00T205– cable C-650 C650FO, Acm itrom C-650; all Aspen Lobs;
Birtcher 737, 771 772 773; Burdick SU-7, SU-
8;Cameron-Miller 26-1 290;aH Concept; EMS
Bard 101-2000, System 2000, 3000, 5000;
D Neomed
3000, 3002; Ritter Bovie CSV, CSV11URO Boyle,
Solid State Bovie, Bovie BS, Bovie 400, Flarsheim,
400B, 400SR; Circon ACMI, Bicop 200
ESU00B206– adapter E Patient Plate Cable or Adapter for Ritter Bovie AG,
ESU00T206– cable Bovie 03, 04, Davis Bovie
E ESU00B207– adapter F Patient Plate Cable or Adapter for Cameron-Miller
ESU00T207– cable 26-230, 26-240, 26-250, 26-255, 26-265, 26-275,
26-280N, 26-290, 80-7910, 26-0269, 80-7960, 80-
1765; Codman Shurtleff J-300
ESU381001– adapter G Ritter adapter for standard handswitching pencil
F with Bovie 400SR and 400B solid state ESUs

ESU100011 H RF Output Transistor for Bovie 400SR (Old Bovie


Part No. 114656/New Bovie Part No. 5139100011)

ESU100044 H Regulator Transistor for Bovie 400SR (Old Bovie


Part No. 111045/New Bovie Part No. 5139100044)

ESU100011 H Output Transistor for Bovie 400CT


(Bovie Part No. 139100011)
G
ESU100047 H Transistor MJ15003 for Bovie 400CT
(Bovie Part No. 139100047)

ESU100046 H Voltge Regualtor MC7815 for Bovie 400CT


(Bovie Part No. 139100046)

ESU100044 H Transistor 2N6262 for Bovie 400CT


(Bovie Part No. 139100044)

H ESU2N6341 H RFSTC Transistor for Bovie 400CT


(Bovie Part No. 139100035)
ESU4
07/06
ELECTROSURGERY/ELECTROCIRUGIA
BIPOLAR FORCEPS
E
A
F
L
B I
M

G J
C
K N

D H

CATALOG NO. FIG DESCRIPTION

ESU765001 A Bipolar forceps, foot switching, 7-3/4” (1 9.685cm) Scoville-Greenwood Bayonet (Insulated)
1 .5mm lip

ESU122001 B Bipolar forceps, hand switching, 4” (10.16cm) Jewelers Micro-Tip, Straight (Insulated), 0.4mm
Tip
ESU769001 C Bipolar forceps, foot switching, 7-1 /2” (19.05cm) Cushing, bayonet, Micro-Tip (Insulated),
0.7mm Tip
ESU123001 D Bipolar forceps, hand switching, 5-1/2” (13.97cm) Semkin, Micro-Tip with Stops (Insulated),
0.7mm Tip
ESU773001 E Bipolar forceps, foot switching, 3-1 /2” (8.89cm) Straight Iris (lnsulated), 0.4mm Tip

ESU120001 F Bipolar forceps, hand switching, 7-1 /2” (19.05cm) Cushing, bayonet, Micro-Tip (Insulated),
0.7mm Tip
ESU771001 G Bipolar forceps, foot switching, 5-1/2” (13.97cm) Semkin, Straight (Uninsulated), 0.7mm Tip

ESU770001 H Bipolar forceps, foot switching, 8-1/4” (20.955cm) Hardy, bayonet, Micro-Tip with Stops
(Uninsulated), 0.5mm Tip
ESU766001 I Bipolar forceps, foot switching, 4” (10.16cm) Jeweler’s Micro-Tip Curved (Insulated), 0.4mm
Tip
ESU774001 J Bipolar forceps, foot switching, 3-1/2” (8.89cm) Curved Iris (Insulated), 0.5mm Tip

ESU121001 K Bipolar forceps, hand switching, Scoville-Greenwood bayonet, 7-3/4”, (19.685cm) (Insulated),
1 .5mm lip
ESU767001 L Bipolar forceps, hand switching, Jewelers Micro Straight tips, 4” (10.16cm), (Insulated),
0.4mm Tip
ESU772001 M Bipolar forceps, foot switching, 6” (15.24cm) Semkin, Straight (Insulated), 1.5mm Tip

ESU768001 N Bipolar forceps, foot switching, 5” (12.7cm) Adson, Straight (lnsulated),1.0mm Tip

ESU136000 — Bipolar forceps, foot switching, Omni Straight Tips with Stops, Diamond Pattern, round han-
dle, 6” (15.24cm) (Non-insulated), 0.7mm Tip

ESU136001 — Bipolar forceps, foot switching, Omni Curved Tips with Stops, Diamond Pattern, round han-
dle, 6” (1 5.24cm), (Non-insulated), 0.7mm Tip
ESU5
07/06
ELECTROSURGERY/ELECTROCIRUGIA
BIPOLAR FORCEP CABLES
A B C

D E F

CATALOG NO. FIG DESCRIPTION

ESU102002 A Disposable Bipolar Cord, 10’ (3.05m) lengths. Sterile 10/BX

ESU845001 B Bipolar Forceps Cable, Reusable, 12’ (3.66m)

ESU130001 C Bipolar Forceps Cable for Hand-switching Bipolar Forceps use with the BISTAT™ and EX-
CALIBUR Units, Reusable, 12’ (3.66m)

ESU131001 D Bipolar Forceps Cable for Hand-switching Bipolar Forceps use with Aspen MR 450 and As-
pen MR 3B0 Units, Reusable, 12’ (3.66m)

ESU132001 E Bipolar Forceps Cable for use with most Valleylab Units, Reusable, 12’ (3.66m)

ESU135001 F BISTAT™ Power Control Cable for use with BISTAT Bipolar Unit and Hand– or Foot
Switched Forceps, Reusable, 12’ (3.66m)

ESU135166 — Sterile cord for foot switching bipolar forceps, with 12’ (3.66m) length. Used with most
standardized electrosurgical generators. 40 per case.

ESUQS2101 — Reusable Bipolar Cable; for use with old type Storz forceps; twin banana plug machine con-
nectors; 10’ long.

ESUQW2201 — Reusable Bipolar Cable; for rise with Wolf forceps; Wolf type machine connector; 10’ long.

ESUQI2301 — Reusable Bipolar Cable; for rise with Wolf forceps; twin banana plug machine connectors; 10’
long.

ESU816001 — TUR Cable with standard (Bovie #12) Plug. Reusable, Monopolar

ESU824001 — Cable for Reusable Monopolar Forceps and Suction Coagulator, 10’ (3.05m)

ESU121001 — Single Use TUR/Endoscopic Cable for ACMI, 10’(3.05m), Sterile, Monopolar. 50 per case
ESU6
07/06

You might also like