Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Equinox UM EN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 80

Adam Equipment

EQUINOX
Software revision c18.00.180 102

© Adam Equipment 2018


    Easy Reference:  
    
Model name of the scale:
 
Serial number of the unit:
 
Software revision number 
(Displayed when power is first turned on): 
Date of Purchase and Address:
 
Name and address of the supplier:
 

© Adam Equipment 2018


CONTENTS
PN 3.01.6.6.14277, Rev B, June 2018

1.0  SAFETY INSTRUCTIONS AND WARNINGS ........................................................................ 3 


2.0  STORAGE CONDITIONS ........................................................................................................... 3 
2.1  OVERVIEW AND ACCESSORIES INSTALLATION ............................................................ 4 
2.2  INSTALLATION LOCATION................................................................................................... 6 
2.3  START-UP................................................................................................................................... 6 
3.0  SERIAL INTERFACE CONNECTIONS .................................................................................. 8 
3.1  TOUCH SCREEN DISPLAY OPERATION ............................................................................. 9 
3.1.1  Operating instructions of the numeric and alphanumeric keypads for entering data.........11 
4.0  STANDBY, LOGOUT, SWITCHING OFF FUNCTIONS ...................................................13 
5.0  SIMPLE WEIGHING .................................................................................................................14 
6.0  CUSTOMISED SETTINGS .......................................................................................................16 
6.1  SELECTING THE LANGUAGE .............................................................................................17 
6.2  SETTING DATE AND TIME ...................................................................................................18 
6.3  CREATING, CHANGING AND SELECTING THE USER PROFILE .................................19 
6.3.1  Recovering and removing passwords....................................................................................24 
6.4  PREFERENCES: LANGUAGE, DISPLAY APPEARANCE, BRIGHTNESS AND BEEPER
25 
6.5  SETTING THE WEIGHING PARAMETERS.........................................................................26 
6.6  SELECTING THE UNIT OF MEASUREMENT ....................................................................27 
6.7  SELECTING THE CUSTOM MEASUREMENT UNITS ......................................................28 
6.8  CALIBRATING AND SETTING THE CALIBRATION MODE ..........................................29 
6.9  SETTING THE PERIPHERALS ..............................................................................................32 
6.10  INFO ABOUT THE SOFTWARE ............................................................................................36 
6.11  SERVICE ...................................................................................................................................36 
6.11.1  System data backup and restore ........................................................................................36 
6.11.2  Factory reset ......................................................................................................................38 
6.11.3  Softwareupdate ..................................................................................................................39 
6.11.4  Balance technical service ..................................................................................................39 
7.0  FUNCTIONS MENU...................................................................................................................40 
7.1  USING THE DATABASE ........................................................................................................41 
7.2  PARTS COUNTING FUNCTION............................................................................................42 
7.2.1  Parts count screen with “Statistics” function. ......................................................................44 
7.2.2  Parts count screen with “Check weighing” function. ..........................................................45 
7.3  “CHECK WEIGHING” FUNCTION. ......................................................................................46 
7.3.1  “Check weight” screen function ...........................................................................................47 
7.4  “PERCENTAGE WEIGHT %” FUNCTION ...........................................................................48 
7.4.1  Percentage Weight % with “Statistics” function. .................................................................50 
7.4.2  Screen of Weight % with “Check weighing” function. ........................................................51 
7.5  DENSITY FUNCTION .............................................................................................................52 
7.5.1  “Density of a solid” calculation function screen. ................................................................54 
7.5.2  “Density of a liquid” calculation function screen ................................................................54 

1
7.5.3  “Density index” calculation function screen ........................................................................55 
7.6  “STATISTICS” FUNCTION ....................................................................................................56 
7.6.1  “Simple statistics” function screen .......................................................................................57 
7.6.2  “Database statistics” function screen ..................................................................................58 
7.7  “TEXTILE” FUNCTION ..........................................................................................................60 
7.7.1  “Textile” function screen. .....................................................................................................61 
7.7.2  Textile function database with statistics enabled screen ......................................................62 
7.8  DYNAMIC/ ANIMAL WEIGHING FUNCTION ...................................................................64 
7.9  “PEAK HOLD” FUNCTION ....................................................................................................66 
7.10  “FORMULATION” FUNCTION .............................................................................................67 
7.10.1  Simple formulation function screen. .................................................................................70 
7.10.2  Database formulation function screen ..............................................................................71 
7.11  SETTING THE GLP DATA......................................................................................................73 
8.0  TECHNICAL FEATURES.........................................................................................................75 

2
1.0 SAFETY INSTRUCTIONS AND WARNINGS
CAUTION!
Please read these instructions for installation and operation carefully before
starting your work with the new balance. Using a balance other than the one in
this manual does not guarantee the safety of the product. Carefully store the
instruction manual.

Equinox balances comply with the directives and standards for electrical equipment,
electromagnetic compatibility and safety requirements.
If the installation is not performed in accordance with the instructions given or is improperly
used, all warranty rights will lapse.

 Do not use the balance in areas at risk of explosion.


 Before starting the balance for the first time, check if the power supply unit or
the power cord is damaged and check if the power voltage corresponds to
the mains voltage.
 To disconnect the balance from mains power, unplug the power cord first.

2.0 STORAGE CONDITIONS

 Storage temperature: +5 °C…+40°C

 Storage humidity: 45% - 75%.

 Keep the balance packaging. In the event of return for service; disconnect all cables,
top pans and any accessories to prevent unnecessary damage in transit.

 Do not expose the balance to extremes of temperature and humidity, and avoid violent
shocks.

© Adam Equipment 2018 3


2.1 OVERVIEW AND ACCESSORIES INSTALLATION

EAB & EPB models

Draft shield

Weighing plate/ Top pan

Spirit level
Keypad

RS-232 connection Mains connection

Power button

Sub pan

© Adam Equipment 2018 4


ETB models

Weighing plate/
Power button Top pan

Keypad

RS-232 connection Mains connection

Sub pan

Spirit level

© Adam Equipment 2018 5


2.2 INSTALLATION LOCATION

 Remove the balance and all its accessories, from the packaging and check for visible
damage to the balance.

 Do not install the balance in any room where there are any air currents, strong heat
shifts, and vibrations.

 Do not use the balance in explosive atmospheres.

 The ambient humidity to use the balance should be between 45% and 75%.

2.3 START-UP
For internal calibration models, manually remove the brass screw at
the bottom left-hand of the balance and in its place, insert the chrome
screw.

CAUTION!

EAB & EPB models

1) Level the balance by adjusting the legs on the front of the balance.

Spirit level
Adjustable feet

2) Insert the supplied power supply unit jack into the connector on the back of the balance.

© Adam Equipment 2018 6


3) Then connect the power adapter to the power outlet near the balance. Do not use
cables/extensions that do not comply with applicable regulations.

N.B. Check that the power shown on the balance plate label corresponds to the one in
use in the country of use.

ETB models

1) Level the balance by adjusting the legs on the front of the balance.

Adjustable feet Spirit level

2) Insert the supplied power supply unit jack into the connector on the back of the balance.

3) Fit the top pan onto the 4 prongs located on the sub pan, adjust until stable.

4) Then connect the power adapter to the power outlet near the balance. Do not use
cables/extensions that do not comply with applicable regulations.

© Adam Equipment 2018 7


N.B. Check that the power shown on the balance plate label corresponds to the one in
use in the country of use.

All models:

Wait 30 minutes after switching on and calibrate the balance after leveling it. For calibration
procedures, please refer to the "calibration chapter". Perform the balance calibration
whenever it is moved to another place.

Do not drop excess weight objects on the balance weighing plate to prevent damaging it.

Service must be performed by specialized personnel and the spare parts used must be
genuine. To do so, contact the dealer or Adam Equipment at www.adamequipment.com.

3.0 SERIAL INTERFACE CONNECTIONS


The balance is equipped with an RS 232C interface for connection to a serial printer.
To ensure communication between the balance and a printer, the following conditions must
be met:
Connect the printer using a suitable cable matching the position of the pin outputs with the
balance pin outputs shown below.
Set the transmission speed and type of printer correctly according to the parameters of the
printer. See Chapter 6.9.

N.B. It is recommended that you use the Adam ATP printer to ensure proper print operation.
(If you are using different printers, you may not be able to print the chart).

© Adam Equipment 2018 8


3.1 TOUCH SCREEN DISPLAY OPERATION
The balance comes with a 5” colour touch screen display that lets you touch the screen in
active areas to quickly access the various menus and features.

1
Indication area for weighing values
Measuring unit indication, by tapping the symbol, you can access the
g measurement unit menu and select the desired unit.
Stability indicator.

Capacity tracker

Shows the balance maximum capacity and increment.

© Adam Equipment 2018 9


2
The Top Bar displays the date, time, user selection, access to weighing functions, weighing
and balance shutdown parameters setting.

Tap this area to access the available function menu.

Tap this area to access the menus for weighing settings, display
preferences, peripheral units setup, and user customisation.

Tap this area to access the switching on or off menu for the balance
standby parameters.

Tap this area to access the users menu to quickly select


Default
programmed users.

3
Function key display bar.

Touching the keys displayed in this area, operates the corresponding function. Below are all
the keys available in the simple weighing screen. The function key display bar varies
according to the selected applications.

Key bars available in simple weighing screens:

Print: Data printing key.

-0-: Zero key.

-T-: Tare operation key.

Tm: Key for manually entering a tare value.

© Adam Equipment 2018 10


3.1.1 Operating instructions of the numeric and alphanumeric keypads for entering
data
The operation of the alphanumeric keyboard described below works for all data entry
operations in the various operating modes.

Mode 1
Alphanumeric keypad.

Selection key for entering uppercase or


lower case letters

Delete key of the last entered character

Mode 2

Delete key for all entered characters

Back and forward cursor movement key on


the inserted data string

Key to confirm and store the entry


Mode 3

Keyboard character selection key. Tap this


key to rotate the various characters
available for entry:
Mode 1, Mode 2, Mode 3

Cancel key.

© Adam Equipment 2018 11


Numeric keypad.

Delete key of the last entered character

Key to confirm and store the entry

Delete key for all entered characters

Input operation cancellation key.

Key for selecting the unit of measurement.

© Adam Equipment 2018 12


4.0 STANDBY, LOGOUT, SWITCHING OFF FUNCTIONS
After inserting the power cord into the mains socket, the balance will automatically turn on
showing the basic weighing screen.

Tap the area with the symbol below


to access the power off menu.

There are 3 power off modes:

 Display off.
 Logout.
 Power off.

Display off
By selecting the display off mode, the
balance will enter standby mode, the
display will be off and it will remain ON
only in the lower-right command to turn
on the system again.
Touch the symbol to return to the basic
weighing screen.

Logout
Select the logout mode and touch the
“Start” key to open the user login, if the
user is password-protected, you will be
required to enter it.

Touching the key , will let you select


another user and start the balance again.

Switching off
By selecting the power-off command, the
balance will be off. To restart, you will need
to press the on/off button or remove the
power plug and reinsert it.

© Adam Equipment 2018 13


5.0 SIMPLE WEIGHING

Stability symbol

On the entry weighing screen, the area


displaying the weight shows the weight
value on the top of the balance’s
weighing plate/ Top pan.

Use the -0- key to set a new zero point


and reset all tare values.

If working with containers, first zero the


balance. Place the container and
press the “-T-”key.

Or use the Tm key to enter a known


tare value manually.

The Net symbol on the display


indicates the net weight. Press “Net”
to see the gross weight “Lrd”.
“T= “indicates the tare value
captured.

Place the material to be weighed on


the balance and wait for the stability
symbol (see previous image) to light
up before detecting the value.

© Adam Equipment 2018 14


Press “Gro” and “Net” to display the
gross and net weights and vice versa.

To reset the balance, remove all items


from the plate and press the “- 0 -“key.

If you entered a manual tare, press “T-


Man/ Tm” and “C” key to clear the
tare value.

© Adam Equipment 2018 15


6.0 CUSTOMISED SETTINGS

This section explains all the customisation features of the balance. Each function described
below will allow you to set up the balance differently for each user.
N.B. Some settings can only be modified by users with administrator permissions.

 Calibration menu
 Setup
 Users setup
 Preferences
 Info
 Service

To access the settings menu, tap the button in the top bar of the display:

The following screens will be displayed with all the functions of the setup menu.

To scroll through the next and back Return to the Exit from the
pages, tap on the arrows. previous screen menu

Function indicator not available or not enabled for users


without administrator rights.
© Adam Equipment 2018 16
6.1 SELECTING THE LANGUAGE
In the settings menu, select the "Preferences" function.

Tap “Language” in the menu list.

You can select the balance's use language.

Then select the desired language.


Automatically, all screens will be translated into
the selected language.

N.B. The selected language will only be


assigned to the user with whom the selection
was made.

© Adam Equipment 2018 17


6.2 SETTING DATE AND TIME
Select “Setup” in the setup menu.
Enter the new date and time values. You can also select the 24-hour or 12-hour format for the
hour.

N.B. The date and time setting is not customisable for each user, but once defined it will be
changed for all users.

Tap “Date and time” in the menu list.

Tap “Date” in the menu list to change the


date.

Tap “Time” in the menu list to change the


time

Tap “24h – 12h” in the menu list to set the


time format.

A numeric keypad will be displayed for


entering the date and time in
"“dd/mm/yyyy” mode for the date and
“hh:mm:ss” for the time

Tap “OK” to confirm the new settings, “C”


to delete all entered data or tap “X” to exit
without changing the value.

© Adam Equipment 2018 18


6.3 CREATING, CHANGING AND SELECTING THE USER PROFILE

The balance can be customised for multiple users. You can create up to 10 different user
profiles. When first turned on, the “Default” user is enabled and this user cannot be either
deleted or renamed.
Each user can then fully customise all the database settings. Once you've created your profile,
just touch "User Area" on the Home screen and select the user you want. All settings for the
selected user will then be loaded. From this moment on, any changes made to the enabled
user will be stored and made available each time the user is selected.

You can create two types of user:


 Administrator
 Standard

Creating an administrator user allows the user to access all the balance setting features and
changing or deleting other users.
Creating a standard user allows the user to access only some of the balance setting features.
The “No Access” display that appears when you touch a feature that is not available for the
standard user is:

You must log on with an administrator user to change the protected functions. After you have
created an administrator and standard user, you will be able to assign an access password
that will be required each time you select the user and turn on the balance.

Below are all operations related to user modification and deletion.


In the settings menu, select "Setup Users"

This screen allows you to enter the


following functions:

 New user
 Edit user
 Rename user
 Copy users
 Delete user
 User Password

© Adam Equipment 2018 19


 New user
By selecting the "New User" function, you
can define a new user. The maximum
number of users that can be entered is 10.
You will be prompted to select whether the
user you want to create must have
administrator powers or be a standard user.

The keyboard for entering the username


will then be automatically activated.
The maximum number of characters
allowed is 30.

The insertion method distinguishes


between uppercase and lowercase letters,
for example, a user entered as "TEST" will
be different from a user entered as a "test".

After searching for a new user, go back to


the main screen.

Tap the user selection area and select the


user you have just created.
From now on, all changes to the functions,
databases, or analytics results will be
associated with the user, and each time
they are called, they will be automatically
reloaded.

The left-hand symbol of the username


indicates the type of user:

Administrator

Standard

© Adam Equipment 2018 20


 Edit user
In the "Edit user” menu, you can change
the user type ("Standard or Administrator")
and temporarily unlock the standard user
locked settings.

Type
If the user is a standard type in order to
modify the user type, a user's password
with administrator rights will be required.

Select “Standard” to set the user in


standard mode or select “Administrator”
to set the user with administrator rights.

Settings
Selecting this function will prompt you to
enter a user's password with administrator
rights.

Then select the "Enable" function to


temporarily unlock the standard user or
select the "Disable" function to lock the
user again.

After you unlock the user in the base


screen on the left side of the username, an
open padlock will appear.
Unlocking will remain active until it is locked
again through the user editing menu, or
when another user is selected or the
balance is turned off.

© Adam Equipment 2018 21


 Rename users
By selecting the "Rename Users" function,
you can change the name of the selected
user.

Select the user you want to rename.

The name change keyboard will be


displayed.
Tap “X “to cancel the operation or change
the name and confirm with the "Enter" key.

 Copy users
By selecting the "Copy Users" function, you
can create a new user with the same
configuration as an existing user. Existing
databases will not be copied and no new
password protection will be enabled. To
copy the databases of another user, you
need to export and import them to the
desired user.

Select the user you want to duplicate.

Enter the name to assign to the new user


and confirm with the "Enter" key.

 Delete users
By selecting the "Delete Users" function,
you can permanently delete a user and its
databases.

The list of stored users will be displayed,


then select the user to delete.
© Adam Equipment 2018 22
Confirm by tapping the "Yes" key or cancel
the operation by tapping the "No" key.

 User password
By selecting the "User Password" function,
you will be able to assign a "Standard" or
"Administrator" user password.

You will then be asked to re-enter the


password for confirmation.

Enter it and tap the "OK" key.

From this moment on, every time you want


to access the user, you will be required to
enter your password.

N.B. Write down your password and


store it in a safe place.
Warning! In case of loss, you will only
be able to recover the password for the
"Standard" user. The recovery
procedure is described in chapter 6.3.1.

© Adam Equipment 2018 23


6.3.1 Recovering and removing passwords

User password protection is applicable to both "Standard" and "Administrator" users. In the
first case, if the user forgets their password, you can update it from the "User Password"
menu.

After selecting "User Password", you will be


asked to enter the "Old Password".
Enter an administrator password.

Then enter the "New password" to assign


to the user.

Confirm the password you have just


entered.

From now on, the "Standard" user will have


a new login password.

N.B.
To remove the password, upon the
request for entering the new password
and confirmation of the new password,
tap the "OK" key without typing any
value.

CAUTION! If the lost password is that of an administrator, you will need to contact a
Service Center to retrieve it.

© Adam Equipment 2018 24


6.4 PREFERENCES: LANGUAGE, DISPLAY APPEARANCE, BRIGHTNESS AND
BEEPER
For each user, you can set a preference display, the language of use, the activation tone of
the beeper and the brightness of the display. Below are the various options available and their
activation mode.

In the settings menu, select the "Preferences" function.

The parameters that can be set in the


"Preferences" menu are as follows:

 Language (see chapter 6.1)


 Appearance
 Background
 Brightness
 Sound
 Functions

Appearance
You can choose between 5 different colour
combinations and select the desired one by
tapping the corresponding key

Background
You can choose a white or black background.
Select the desired one by tapping the
corresponding key.

Brightness
There are 4 levels of brightness on the display.
Select the desired one by tapping the
corresponding key.

Sound
The sound function enables you to activate or
deactivate the beeper. When activated, whenever
you touch the active parts of the touch screen, a
beep sound is made.

© Adam Equipment 2018 25


6.5 SETTING THE WEIGHING PARAMETERS
For proper use of the balance, it is important to make the correct weighing parameter settings
according to the operating environment.
This section describes the filter parameters, stability, auto-zero and weighing units.

In the settings menu, select the "Setup" function and then select "Weighing parameters".

In the "Weighing parameters" screen, the set


values (in the box to the right of the parameter)
are shown.
By touching the parameter key you want to
change, you can change the value.

 Filter: the filter function allows the user to


speed or slow down the balance’s response
according to weighing requirements and
environmental conditions. By selecting
Level1, the response will be immediate, but
the balance will remain more sensitive to
environmental disturbances such as
ventilation and vibration. By increasing the
level, the response will be slower and the
indication more stable.

 Filter 1: dosage conditions


 Filter 2: stable conditions
 Filter 3: unstable conditions

 Stability: this function allows you to adjust the


balance to the working environment. When
using the balance in a vibration-free
environment, select level 0. The default level
is 2. Use level 3 for very disturbed
environments.

 Stability 0: For stable environments.


 Stability 1: For poorly stable
environments.
 Stability 2: For unstable environments.
 Stability 3: For heavily unstable
environments.

© Adam Equipment 2018 26


 Auto-zero: automatic zero constantly adjusts
the weight value shown to zero. Variations
may be due to dirt, moisture or dust that can
be deposited on the plate. You can disable
this function by selecting "Off" mode.
Autozero 1 is for minor correction until it
reaches level 3E which is the maximum
correction.

6.6 SELECTING THE UNIT OF MEASUREMENT


Weighing operations can be performed with different units of measurement. Below is shown
how to select the desired weighing unit.

In the settings menu, select the "Setup" function and then the "Units selection" function.

On the "Units Selection" screen, all available


weighing units are immediately displayed. Tap
the desired unit to select and enable it.

The last three units of measure, K1, K2, K3, are


customizable units. For reference, refer to the
chapter 6.7 "Selecting the custom
measurement units".

N.B.: The measurement unit selection can


also be made directly from the weighing
screen; by tapping the symbol of the current
unit displayed, you will have access directly
to the list of available units.

© Adam Equipment 2018 27


6.7 SELECTING THE CUSTOM MEASUREMENT UNITS
You can define up to three custom units per user. This allows you to perform calculations
directly from weighing detection (i.e. volume, paper grammage g/m3). The custom weight unit
can be recalled in all fields and menus where the units can be selected.

In the setup menu, select the "Setup" function and then "Custom units setup".

On the “Custom units setup” screen, you can


select one of the three units K1, K2, K3 available
to personalise it.

After the selection, enter the following data:


 Name: enter the unit identifier (max 15
characters).
 Symbol: enter the symbol you want to assign
to the unit of measurement (max. 3
characters). The weight units g, kg, lb and so
on are not allowed.
 Multiplier factor: enter the multiplicative
factor with which the weighing result has to be
calculated
 Decimal point position: enter the position of
the decimal point with which you want to
display the result (i.e. entering 1, the value
123,123 will be displayed as follows: 12312,3)

© Adam Equipment 2018 28


6.8 CALIBRATING AND SETTING THE CALIBRATION MODE
Electronic balances perform mass measurements using gravity (g). Differences in geographic
regions and altitude vary the gravity acceleration (g).
Therefore, in order to obtain accurate measurements, the balance must be adapted to the
place of use and environmental conditions. This adjustment is performed by the calibration
function.

Select the "Calibration menu" function in the settings menu.

In the calibration menu, you can calibrate, display


and print the data for the last calibration and set
the calibration mode.

Before performing the calibration procedure,


check that the pan is empty.

 Calibration: By tapping the calibration key,


the calibration procedure corresponding to the
set calibration mode will be activated.

Load the required calibration weight or tap the


"Cancel" button to cancel the calibration
procedure.

Wait for weight capture.

If the operation is successful, the weighing


screen will display with the calibrated weight
value.

Remove the weight from the plate.

© Adam Equipment 2018 29


 Calibration data: in the calibration data
screen, you can check the date when the last
calibration was performed, the mode with
which it was performed, the weight value
used, and the correction made with respect to
the previous calibration. By tapping the "Print"
button, you can print the displayed data.

 Calibration mode: the balance can be set to


calibrate with two different modes:

External default
By selecting the default calibration mode when
the calibration command is given, the required
weight will be the factory default setting, the value
of which will vary depending on the balance
model.

External custom
By selecting the external custom" calibration
mode, you can set a custom calibration weight
value.

After selecting the "mode of choice", tap the


Weight Setting button to set the desired weight
value.

© Adam Equipment 2018 30


If your balance has internal calibration:

Internal*
By selecting the internal calibration mode when
the calibration command is given, the balance is
automatically calibrated through the motorized
auto-calibration internal system.

Automatic*
By selecting the automatic calibration mode, the
balance automatically calibrates when the
ambient conditions change or within a set time of
60 to 999 minutes. Also with this mode, you can
calibrate each time you want by tapping the
"Calibration" key.

To change the auto-calibration range, tap the


"Calibration Weight" key and set the desired
range between 60 and 999 minutes.

* The internal and automatic calibration mode


is only available for auto-calibration models.

© Adam Equipment 2018 31


6.9 SETTING THE PERIPHERALS
This section describes the features and settings of the RS232 and USB serial outputs that the
balance is equipped with.

In the setup menu, select the "Setup" function and then the "Communication" functions.

In the "Communications" menu screen, you can


immediately check the values of the parameters
set (in the box on the right of the parameter).

Tapping the parameter key to be set will activate


its screen with the list of the various selectable
options.

 Printer: this function allows you to select the


pre-programmed balance connected to the
serial output.
 ATP: command print, by touching the
"Print" button for the Adam ATP printer.

 Adam DU: command print, by touching the


"Print" button for the Adam DU software.

 Generic: command print, by touching the


"Print" button for generic serial type printer.

© Adam Equipment 2018 32


 File on Usb-Key: command print, touching
the "Print" button will print to file. In order to
use this mode, you will need a USB stick to
save the files. (You can use a dedicated
USB stick for that purpose only).
With the "File on Usb_Key enabled" mode
before executing the print command, verify
that the save USB stick is inserted in the
USB port on the left side of the balance.
While saving the file on the screen, you can
scroll through the information that will be
saved in the file.

At the end of the save, the name of the file


assigned automatically will appear on the
screen.
-------------------------------
Liquid density: The USB stick will then contain a
1.0 g/cm3 compressed file with a text file (.txt) showing
the weighing data or the result of the
Air P.: 200.04 g function used.

Liq. P.: 100.02 g Example of printing with density function.

Result (Solid Dens.): 


2.0000 g/cm3
-------------------------------

© Adam Equipment 2018 33


 Baud Rate: serial transmission speed
selection parameter.
Selectable speeds are as follows:

 1200 Baud.
 2400 Baud.
 4800 Baud.
 9600 Baud.
 19200 Baud.
 38400 Baud.

 Stability: check of the stability before data is


transmitted. It is possible to decide whether to
enable or disable stability control before
printing the weight value:

 On. Check enabled.


 Off. Check disabled.

 Print heading: this function allows you to


place a header at the beginning of the receipt.
The function can be:

 On. Heading enabled.


 Off. Heading disabled.
 Print heading Setup: Activation of the
screen for inserting the desired text for the
receipt header.

In the print header screen, tap the rectangles that


indicate the line number to automatically enable
the alphanumeric keypad and enter the desired
text with a maximum number of 40 characters per
line.
Tap the "Ok" key to confirm the entered text.

NB. You can enable and disable the header


function without losing the inserted text, which will
remain stored until the contents of the various
lines are deleted.

© Adam Equipment 2018 34


 Line feed: this function allows you to set a
blank number of lines to add at the end of the
printout to allow the printer to exit from it.
The input numeric keypad will automatically
turn on, so enter the desired number of lines
(between 0 and 9) and tap the "Enter" key to
confirm the entered number.

 GLP: this function allows you to enable or


disable the GLP data printing after user have
entered it

 On. GLP data print enabled.


 Off. GLP data print disabled.

 Time and date: this function enables you to


enable or disable the time and date printing.

 On. Calibration data print enabled.


 Off. Calibration data print disabled.

Time and date printing cannot be deactivated


with the GLP function enabled.

 Balance cal. data: this function enables you


to enable or disable the calibration data
printing of the balance.

 On. Calibration data print enabled.


 Off. Calibration data print disabled.

© Adam Equipment 2018 35


6.10 INFO ABOUT THE SOFTWARE
This section explains how to view information about the software versions of the tool.

In the settings menu, select the "Setup" function then the "Info" one.

The information on the Info screen will be


requested by the technical staff in case of
assistance request.

6.11 SERVICE
This section describes all the functions related to the Service and Backups of the balance
data.

In the settings menu, select the "Setup" function then the "Service" one.

The functions available in the Service


menu are as follows:

 System data backup and restore


 Factory reset
 Software update
 Balance technical service

6.11.1 System data backup and restore

© Adam Equipment 2018 36


You can back up the system completely or restore data and configuration previously saved on
a USB stick.
This section describes the steps to be taken to export or import the data.

N.B. It is recommended to use an empty USB stick that is dedicated to data save and
recovery operations.

 System backup: this command allows


you to save all users and their
configurations stored in the system,
including its drying database and
saved test results.

You must have a USB stick to back up.

Insert the stick into the USB port on the left


side of the balance, and press the "OK"
key.
Tap the "Cancel" button to cancel the
backup operation.

If the USB stick is inserted successfully,


after confirmation, the alphanumeric
keypad will automatically be displayed for
entering the name that you want to assign
to backup.

A screen with the message "Done!" will


confirm that the export operation was
successful.

A backup folder with the assigned name


was then created on the USB stick.

Opening the folder, you will find a set of


files and subfolders that contain all the
data.
N.B: Do not modify or rename any files to
avoid damaging the content. The folder will
be automatically restored to the balance by
using the System Restore command.

 System restore: this command allows


you to restore all users and their
system configurations previously
exported with the backup command on
a USB stick.

© Adam Equipment 2018 37


N.B. You can import the exported data
from another balance, so you can
configure multiple balances with the same
users and the same settings.

Insert the USB stick into the USB port on


the left side of the balance, and press the
"OK" key.
Tap the "Cancel" button to cancel the
system restore operation.

If the USB stick is inserted correctly, after


confirmation, the alphanumeric keypad will
automatically be displayed for entering the
name of the backup you want to restore.

A screen with the message "Done!" will


confirm that the system recovery operation
was successful.

6.11.2 Factory reset


You can perform a total reset of the balance to bring it back to the initial conditions.

Tap the "Factory Reset" button, confirm by touching the "Yes" button, or cancel the operation
by tapping the "No" button.

N.B. Be careful as all data of all users including their databases will be lost. If you want
to save them, make a backup before the factory reset.

© Adam Equipment 2018 38


6.11.3 Softwareupdate
You can make any software updates provided by AE Adam via the USB port.

Below are the steps to be taken to upgrade.

Selecting the "Software Update" function


will display the screen with the confirmation
request.
Select "No" to cancel the operation, or
"Yes" to continue.

Before you insert the USB stick into the


port on the left side of the balance, check
that the stick is loaded with the upgrade
program supplied by AE Adam and confirm
with the "Ok" key.

If the selected file is correct, the upgrade


operation will be enabled and a displayed
counter will indicate the progress status.

N.B. Once the software upgrade


operation has begun, do not power off
the balance until the operation
completes.
During the upgrade, the balance will
turn off and restart automatically; do not
press any key, but wait for the operation
finished successfully indication.

6.11.4 Balance technical service


The technical service function of the balance can only be accessed by password only to the
authorised technical service personnel.

© Adam Equipment 2018 39


7.0 FUNCTIONS MENU
This section describes all the functions available for weighing. All of the features described
below are customisable in their databases for each user; they can be enabled, disabled, and
sequenced according to its usage needs. (See section on preferences in the functions
section.)
So each time you change the user, its function settings will vary.

Tap the button to access the functions menu.

Use the keys , to scroll through the displayed, back and next pages.

Tap the icon corresponding to the function, you want to access the relevant settings.

To exit the functions menu, tap the button or located at the top of the screen.

© Adam Equipment 2018 40


7.1 USING THE DATABASE

All functions can be customised for each user by storing the desired modes and items through
the relevant database.
The following are the search, save, delete, and editing functions for all databases. For
entering data in the database, refer to the paragraph corresponding to the desired function.

After selecting the desired function, tap the "Database" key to access the database menu for
the desired function.

 Every time a new user is created, the


database will be completely empty.
The following describes all the
functions available to all databases:
 Selection by name: by tapping this
key you can call up a program by
entering the corresponding name.
 Selection list: by tapping this button
you can call up a program by selecting
it from a list.
 New: insert new record (refer to the
paragraph corresponding to the
desired function).
 Edit: by tapping this button, you can
access the editable parameters of the
function.
 Delete: tap this button to delete one or
more previously stored records.
 Print: by tapping this button, you can
select a record and print it.
 Export (Usb): by tapping this button
you can export the database to the
USB stick.
 Import (Usb): by tapping this key, you
can import a previously predefined
database from a USB stick.

Use the keyboard to enter the name to


assign to the new record.
The maximum number of characters that
can be entered is 30.

Tap the "Enter" key to confirm.

© Adam Equipment 2018 41


7.2 PARTS COUNTING FUNCTION

The parts counting function allows you to count parts through sampling with a certain number
of parts or by entering entry the average weight value of the number of parts to be counted.

To access the function from the "Functions" menu, tap the "Parts Counting" icon.

Parameters entry:
Mode:
By tapping this key, you can select the
count mode:
 Weigh samples.
Counting by sampling a certain number of
pieces. Enter the number of samples you
want to use for the count by tapping the
"Number of samples" key.
 Unit mean weight.
Count by entering the weight value of the
single piece to be counted. Enter the
weight value by tapping the button "Unit
mean weight"

Start:
After selecting the count mode, tap the
"Start" button to perform the count of the
pieces.

© Adam Equipment 2018 42


If the user wishes to tare out a container,
before sample counting, they will be
required to load the number of pieces
chosen (for sampling) on the plate, while in
average unit weight mode you can count
pieces directly.

Database:
By tapping the "Database" key, you can
create a custom counting database of
different items and methodologies.
Using the database in addition to piece
counting, you can perform statistical count
control and use up to two threshold levels
for packing control.
Tap the "New" key and enter the name of
the new record to be stored.

 Description: enter a description of the


item.
 Mode: select the count mode.
 Samples number/ Unit mean weight:
enter the number of samples or the
average unit weight of the pieces.
 Options: you can select the statistical
control by activating the "Statistics"
function or by controlling the pieces by
activating the "Control of value"
function.

Statistics:
 To enable this function, you need to
include:
 Nominal value: enter the nominal
value of the number of pieces to be
controlled.
 T2+, T2-, T1+, T1-: enter the error
tolerance threshold values. (Optional
entry).
 Save: tap the "Save" button to store
the recorded record.

© Adam Equipment 2018 43


To enable this function, you need to enter:
 Lower limit: enter the minimum
number of acceptable pieces.
 Upper limit: enter the maximum
acceptable number of pieces.
 Sound: you can activate or deactivate
the beep function when the number of
pieces is within the set range.
 Save: tap the "Save" button to store
the recorded value.

7.2.1 Parts count screen with “Statistics” function.


The following describes the pieces counting functions with statistical calculation.

Statistics
Parameters used for
counting

Weights performed

Last weighing
delete key.

Tap the "Ok" key to capture a new weight and tap the "End" key to end the capture and
perform the final statistical calculation.
© Adam Equipment 2018 44
7.2.2 Parts count screen with “Check weighing” function.
The following describes the parts counting functions with check weighing.

By tapping the "i" key you can see the parameters used for counting the parts.

The parts number control bar is yellow when the number of parts loaded is lower than the Lo
limit. It is green when the parts are within the set range (with the beep indication when
activated) and red when the number of parts exceeds the upper limit set.

© Adam Equipment 2018 45


7.3 “CHECK WEIGHING” FUNCTION.

This function allows you to define three different weight check methods:
 Weight check with High limit.
 Weight control with Low limit
 Weight control within the OK limit.

To access the function from the "Functions" menu, tap the "Checkweighing" icon.

To activate the function, enter the values for


the "lower limit" or "upper limit" or both,
according to the method you want.

Lower Limit, Upper Limit:


In the Limit Input screen, you can select the
unit of measurement to be used for testing by
tapping the "Unit" key.
To deactivate the limit, enter the value "0" or
tap the "C" key and then tap the "enter" key.

Alarm: enable or disable the beeper. In case


of enabling when the weight value is within the
set range, a beep is release.

Start:
After entering the required data, tap the "Start"
button to activate the weight check function.

Database:
By tapping the "database" button, you can
create a custom weight check database with
different items and methods.
Tap the "New" key and enter the name of the
new record to be stored.
Enter the required data:
 Description: enter a description of the
item.
 Lower limit
 Upper limit
 Alarm

Then tap the "Save" button to save the record.

© Adam Equipment 2018 46


7.3.1 “Check weight” screen function
The Check weight function screen is described below.

By tapping the "i" key, you can see the parameters used for counting the parts.

The Check weighing bar is yellow when the loaded weight is lower than the low limit and
green when the weight is within the set range (with the beep indication when activated) and
red when the weight is greater than the high limit.

© Adam Equipment 2018 47


7.4 “PERCENTAGE WEIGHT %” FUNCTION

This function allows you to determine the weight percentage of a sample based on a
reference weight.
The value of the reference weight can be obtained by a sample weight or by manually
entering the weight value.

To access the function from the "Functions" menu, tap the "Weight %" icon.

Select the mode:

Automatic reference:
Selecting this mode upon startup will
require you to load the reference sample
weight (100%) onto the weighing plate.

Manual reference:
When selecting this mode, you are required
to enter the reference weight value (100%).
Tap the "Reference Weight" key and enter
the weight value in the input screen and
select the desired unit of measurement.

Start:
After selecting the desired mode and
entering the required data, tap the "Start"
button to run the "Weight%" function.

Database:
By tapping the "Database" button, you can
create a custom database to perform
percent weighing with different
methodologies.
Using the database in addition to the
simple percentage weighing, will allow you
to perform statistical weighing checks or set
up to two levels of weight check thresholds.
Tap the "New" key and enter the name of
the new record to be stored.

 Description: enter a description of the


item.
 Mode: select the weight reference
mode.

© Adam Equipment 2018 48


 Reference weight: enter the reference
weight value in manual weight mode.
 Options: you can select the statistical
control by activating the "Statistics"
function or the weight check by
activating the "Value check" function.

Statistics:
To enable this function, you need to enter:
 Nominal value: Enter the nominal
weight value to be checked.
 T2+, T2-, T1+, T1-: enter the error
tolerance threshold values. (Optional
entry).
 Save: tap the "Save" button to store
the recorded record

Check weighing:
To enable this function, you need to enter:
 Lower limit: enter the minimum
acceptable weight value.
 Upper limit: enter the maximum
acceptable weight value.
 Sound: you can activate or deactivate
the beeper function when the weight is
within the set range.
 Save: tap the "Save" button to store
the recorded value.

© Adam Equipment 2018 49


7.4.1 Percentage Weight % with “Statistics” function.
The following are the functions of the weighing% with statistical calculation.

Weighting statistics

Parameters used for


the weight %

Weighting performed

Last weighing
delete key.

Tap the "Ok" key to capture a new weight and tap the "END" key to end the capture and
perform the final statistical calculation.

© Adam Equipment 2018 50


7.4.2 Screen of Weight % with “Check weighing” function.
The following are the functions of the weight% with checkweighing.

By tapping the "i" key, you can see the parameters used for weight check.

The percentage weight check bar is yellow when the loaded weight is lower than the low limit,
green when the weight is within the set range (with the beep indication when activated) and
red when the weight is greater than the high limit.

© Adam Equipment 2018 51


7.5 DENSITY FUNCTION

The density function allows the user to determine the density value of solid or liquid
substances. The determination is based on Archimedes’ principle that a body immersed in a
liquid receives an upward thrust equal to the weight of the volume of the displaced fluid. For
the determination, you can use a below balance weighing balance (if present in the scale or
the "optimal density weighing kit" to place on the weighing plate.

To access the function from the "Functions" menu, tap the "Density" icon.

Select the mode:


Liquid density: when selecting this type of
measure, you will be required to enter the
solid density value (g/cm3) to be used to
determine the density of the liquid.
Then tap the "Start" button to proceed with
the measurement.

Solid density: when selecting this type of


measure, you will be required to enter the
liquid density value (g/cm3). If using
distilled water or ethanol, select the
relevant item below and enter only the
liquid temperature value. The density of the
selected liquid at the entered temperature
will automatically be entered. (The
reference tables are stored inside the
balance).
Tap the "Start" button to proceed with the
measurement.

Density index: by selecting this type of


measurement, you can determine the
difference in density as a percentage
between two solid samples. (One solidified
at room temperature and the other under
vacuum).
The density index can be determined by
measuring the density value for both
samples, or by using the "theoretical
density" value for the sample solidified at
room temperature and measuring the
density value only for the vacuum sample.
In this case, you need to tap the
"Theoretical density" key to enter the
value.
Then tap the "Start" button to proceed with
the measurement.

© Adam Equipment 2018 52


Optional information about the
measurement to be performed will be
required.

Tap the "Enter" key to confirm.

Now perform the steps shown on the


display to determine the density index.

Database:
By tapping the "database" key, you can
create a custom database to determine the
different density types.
Tap the "New" key and enter the name of
the new record to be stored.

 Description: enter a description of the


item.

 Measurement type: Select the type of


density to be determined.

After entering all required data, tap the


"Save" key to save the new record.

© Adam Equipment 2018 53


7.5.1 “Density of a solid” calculation function screen.
Below are the functions for calculating the density of a solid.

Detected values for density determination

Information about the database


used:
Record name
Test description

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement, and the
"Print" key to print the measurement result.

7.5.2 “Density of a liquid” calculation function screen


Below are the functions for calculating the density of a liquid.

Detected values for density determination

Information about the database


used:
Record name
Test description

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement, and the
"Print" key to print the measurement result.

© Adam Equipment 2018 54


7.5.3 “Density index” calculation function screen
Below are the functions for calculating the density index.

Detected values for density determination

Information about the database


used:
Record name
Test description

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement, and the
"Print" key to print the measurement result.

© Adam Equipment 2018 55


7.6 “STATISTICS” FUNCTION

This function allows you to perform weighing statistics in simple mode, without defining the
nominal weight and tolerance value, or, using database statistics, you can define the relative
nominal weight and tolerance values. At the end of the procedures in both cases, it is possible
to print the statistical result of the weights.

To access the function from the functions menu, tap the "Statistics" icon.

Select the mode:


Simple statistics: by selecting the simple
function, you can perform the statistics up
to 500 consecutive weights.
Tap the "Simple Statistics" button and
immediately the screen will be activated to
perform the weighing.

Database: by selecting the statistical mode


from the database, you can store and then
recall a custom statistics method.

By tapping the "database" key, you can


create a custom database to determine the
different density types.
Tap the "New" key and enter the name of
the new record to be stored.

 Description: enter a description of the


item.

 Nominal weight: enter the nominal


weight value and select the desired
unit of measurement.

 Enter values for tolerance check


(Optional Data).

 T2+ : 2nd positive tolerance


 T2- : 2nd negative tolerance
 T1+ : 1st positive tolerance
 T1- : 1st negative tolerance

After entering all required data, tap the


"Save" key to save the new record. Before
performing the save, a check of the entered
data is performed. An error will be reported
to make the necessary corrections if
necessary. After, press the save key.

© Adam Equipment 2018 56


7.6.1 “Simple statistics” function screen
Below are the simple statistical functions.

Tap the “Ok" key to capture a new weight.


Tap the “Tm" key to enter a manual tare value
Tap the “-T-“key to run a manual tare
Touch the “- 0 “key to reset the plate.
Tap the "End" key to end the weighing acquisition and follow the statistical calculation

List of the values captured

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

© Adam Equipment 2018 57


7.6.2 “Database statistics” function screen

Below are the functions related to the database statistics


function. Delete last captured weight

Display weights captured

Tap the “Ok" key to capture a new weight.


Tap the “Tm" key to enter a manual tare value
Tap the “-T-“key to run a manual tare
Touch the “- 0 “key to reset the plate.
Tap the "End" key to end the weighing acquisition and follow the statistical calculation

Tap the key to display the parameters set for statistical calculation

After tapping the "End" key, the screen with the result of the weighing statistics is displayed.

© Adam Equipment 2018 58


Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

© Adam Equipment 2018 59


7.7 “TEXTILE” FUNCTION

This function determines the number of the yarns by weighing a known length bundle. Using
the database function, you can also perform a weighing statistics.

To access this function from the "Functions" menu, tap the "Textile" icon.

Length:
Enter the value of the bundle length; the
value can be expressed in meters or yards.
To select the desired unit on the Length
Input Screen, tap the "Units" key and make
the selection.

Units:
Select the unit with which you want to view
the result. (Tex, Td, Nm, Nc). However, the
selected unit can still be modified during
weighing by tapping the symbol displayed
to the left of the weight.

Start:
After entering the required data, tap the
"Start" button to execute the "Textile"
function.

Database:
By touching the "database" key, you can
create a custom database for "Textile"
weighing.
Using the database in addition to the
simple "textile" weighing, you can perform
the statistical check of the weights.
Tap the "New" key and enter the name of
the new record to be stored.

 Description: enter a description of the


item.
 Length: select the desired
measurement unit and enter the length
of the bundle.

© Adam Equipment 2018 60


 Unit: select the unit with which you
want to view the result. (Tex, Td, Nm,
Nc). However, the selected unit can
still be modified during weighing by
tapping the symbol displayed to the left
of the weight
 Statistics: you can activate the
statistical check of the weights.
Activating this function, you must enter
the following data:

 Nominal value: select the unit of


measurement and enter the nominal
weight value to be checked.
 T2+, T2-, T1+, T1-: enter the error
tolerance threshold values. (Optional
entry).
 Save: tap the "Save" button to save
the entered record

7.7.1 “Textile” function screen.


Below are the functions in the "Textile" screen.

Bundle length information and Exit the function


weight value in g

Measured unit
Tap the "Ok" key to acquire a new weight selection key
Tap the “Tm” key to enter a manual tare value displayed
Tap the “-T-“key to run a manual tare
Touch the “- 0 -“key to reset the plate.

© Adam Equipment 2018 61


7.7.2 Textile function database with statistics enabled screen
Below are the functions related to the statistical database textile function.

Tap the "Ok" key to acquire a new weight.


Tap the "Tm" key to enter a manual tare value
Tap the "-T-" key to run a manual tare
Touch the "- 0 -" key to reset the plate.
Tap the "End" key to end the weighing acquisition and follow the statistical calculation

Tap the key to delete the last weight acquired.

Tap the key to view the weights acquired

Tap the key to display the parameters set for statistical calculation

© Adam Equipment 2018 62


Tap the key to display the temporary statistical report

After tapping the "End" key, the screen with the result of the weighing statistics is displayed.

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

© Adam Equipment 2018 63


7.8 DYNAMIC/ ANIMAL WEIGHING FUNCTION

This function allows you to measure the weight of unstable samples (i.e. animals) or samples
that are in very unstable environments. The weight is determined in the form of an average
value based on multiple weight measurement cycles within the set time interval.

To access the function from the "Functions" menu, tap the "Animal Dynamic" icon.

Time setting:
Enter the express measurement time in
seconds. (Minimum value 5 seconds,
maximum 90 seconds)

Start:
After entering the required data, tap the
"Start" button to perform the “Animal
weighing " function.

If necessary, reset the indication or load


any tare.
Load the sample to be analyzed and tap
the "Ok" key.

© Adam Equipment 2018 64


Information during weight capture

Countdown indication

Tap the "Cancel" button to cancel the measurement


Tap the "Stop" button to stop the countdown and display the result

Information at the end of weight capture

The average value of


the weights captured
in the set time
interval

Indication of the time


used for the
measurement

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.
.

© Adam Equipment 2018 65


7.9 “PEAK HOLD” FUNCTION

This function allows to measure the peak hold level.

To access the function from the "Functions" menu, tap the "Peak hold" icon.

Selecting the function immediately displays


the measurement screen.
 Prepare the sample to be tested on
the weighing plate.
 Perform tare or zero reset if
necessary.
 Tap the "Ok" key to start the test.

Once the tested peak level is reached, the


maximum weight will be displayed.

Weight detected on the plate

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

© Adam Equipment 2018 66


7.10 “FORMULATION” FUNCTION

This function allows you to prepare a compound by dosing a set of components in manual
mode "Simple formulation" or by calling a formula with ingredients and tolerances previously
entered in the formulations database.

To access the function from the "Functions" menu, tap the "formulation" icon.

Simple formulation:
This mode allows you to carry out a series
of consecutive weights and finally get the
total weight of the dosed components and
the relative list with the value of the
individual weights.

Tapping the "Simple formulation" button


immediately displays the measurement
screen.

 Load any container and run the tare.


Or, if necessary, reset the indication
with the "0" key.
 Now dose the first component and
tap the "Ok" key to confirm the
capture.
 Then repeat the operation for all the
components of the formulation.
 To finish the dosing operation of the
components, tap the "End" key.

© Adam Equipment 2018 67


Database formulation:
By tapping the "database" key, you can
create a custom database for the
"formulation" function.
Using the database, you can store custom
formulations with a set of components and
their tolerances.
Tap the "New" key and enter the name of
the new record to be stored.

 Description: enter the items


description.
 Add: tap the add button to insert a
component.

 Name: enter the name of the


component.
 Quantity: select the desired unit of
measurement and enter the nominal
quantity of the component.
 Toll T+: enter positive percentage
tolerance.
 Toll T-: enter negative percentage
tolerance.
 Confirmation: tap the confirmation
key to accept the entered values.
Verification of the correctness of the
data entered in case of error signal will
be performed; check that all
parameters entered are congruent.

After confirming, proceed with the "add"


button to enter all the desired components.

 Save: after entering all the desired


components, tap the "Save" button to
store the formulation.

© Adam Equipment 2018 68


To recall the formulation entered in the
database, use the "Select From List"
command, select the formulation you want
and proceed as shown below.

After selecting the desired formulation, a


summary screen will be displayed showing
all the components and their amount
needed to make the formulation.

Tap the "Ok" key to confirm and proceed


by entering the multiplication factor needed
to determine the total amount of the
formulation.
(i.e. if the formulation has been stored to
produce 10g of product and you want to
produce 100g insert a "K" factor of 10). If
the entered value does not allow the dosing
of one of the components because its
quantity exceeds the scale capacity, it will
not be accepted.

If the total weight of the formulation instead


exceeds the scale capacity, but the
individual components are lower, the user
will be asked whether to proceed with the
"separate formulation".
 Yes: to proceed with the separate
formulation.
 No: to change the value of the
multiplier factor "K" and reduce the
quantities.

The formulation screen shows the type of


formulation you are using by displaying two
symbols as described below:

Symbol displayed in case of "unique


formulation".

Symbol displayed in case of "separate


formulation ".

© Adam Equipment 2018 69


7.10.1 Simple formulation function screen.

Tap the "Ok" key to acquire a new weight.


Tap the "End" key to end the weighing capture and follow the statistical calculation

Tap the key to clear the last weight acquired.

Tap the key to view the weight acquired.

After tapping the "End" key, the screen appears with the result for the sum of the weights.

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.
© Adam Equipment 2018 70
7.10.2 Database formulation function screen

Tap the "Ok" key to acquire a new weight.


Tap the “T” key to reset the weight indication.

Tap the key to view the list of the formulation components and the components
already entered:

Dosing bar:

The dosing bar works with automatic graduated enlargement. When the dosed quantity
approaches the two levels of tolerance, the center zone is automatically enlarged to allow
dosing with a greater sensitivity.

The bar takes on different colours:


Yellow when the loaded weight is lower than the low limit.
Green when the weight is within the set range.
Red when the weight is higher than the high limit.

© Adam Equipment 2018 71


When the correct dosage of all components is completed, the actual dosed amount will be
displayed:

Tap the key to view the complete list of components and their dosed quantities.

Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

© Adam Equipment 2018 72


7.11 SETTING THE GLP DATA
This function allows you to customise and create a database with GLP parameters.
To access the function from the "Functions" menu, tap the "GLP" icon.

GLP Setup: use this command to enter


GLP parameters when you do not want to
save them to the database.

The data entry screen will be displayed.


Tap the corresponding parameter to enter
the desired data.

 Balance ID
 Project ID
 User ID

After entering the data, press the “Ok” key


to confirm.
Note that the maximum number of
characters allowed per parameter is 20.

GLP Database: by tapping this command,


you can access the GLP parameter
database management menu

Below are all the available functions


 Select by name: by tapping this
key, you can call up a program by
entering the corresponding name.
 List all: by tapping this button, you
can call up a program by selecting
it from a list.
 New: by tapping this button, you
can enter a new record.
 Edit: by tapping this button, you
can access the GLP parameters
that can be changed.
 Delete: tap this button to delete
one or more previously stored
records.
 Print: by tapping this button you
can select a GLP record and print
it.
 Export (Usb): by tapping this
button, you can export the
database to the USB stick.

© Adam Equipment 2018 73


 Import (Usb): by tapping this key,
you can import from a USB stick a
predefined database previously

The selection, edit, delete, print, export and


import commands are the same as
described in chapter 7.1

New: this command allows you to enter a


new record.

Enter the name you want to assign to the


record and confirm with the "Enter" key.

The data entry screen will be displayed.


Tap the corresponding parameter to enter
the desired data.

 Balance ID
 Project ID
 User ID

After entering the data, press the "Save"


key to confirm.

In order to save data, at least one of the


three fields must be filled in, otherwise an
incomplete data screen will be displayed.

After entering the record, use the "Select


from list" or "Select by name" command
to select it. 

Tap the desired record and confirm with the


"Ok" key.

N.B. By entering the "GLP" command in


the print setup menu or in the save file,
the data set in the "Balance id, Project
id, User id" fields will be reported.

© Adam Equipment 2018 74


8.0 TECHNICAL FEATURES
The Equinox series of balances are all intended for indoor use. Maximum height of use: 4000m; Degree of Pollution: 2; Overvoltage
category: II

For M models:

Power supply unit INPUT: Switching 100-240Vac~ 50/ 60Hz, OUTPUT: 24V DC 550mA, Potential Max overload power
supplied: 13.2VA
Adaptation to
Selectable filters
environmental
conditions:
Autozero: Selectable from menu
Serial output: RS232C
Working temperature: +5°C - +35°C

© Adam Equipment 2018 75


WARRANTY INFORMATION
Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed
due to defects in materials or workmanship. Warranty starts from the date of delivery.

During the warranty period, should any repairs be necessary, the purchaser must inform
its supplier or Adam Equipment Company. The company or its authorised Technician
reserves the right to repair or replace the components at any of its workshops depending
on the severity of the problems. However, any freight involved in sending the faulty units
or parts to the service centre should be borne by the purchaser.

The warranty will cease to operate if the equipment is not returned in the original
packaging and with correct documentation for a claim to be processed. All claims are at
the sole discretion of Adam Equipment.

This warranty does not cover equipment where defects or poor performance is due to
misuse, accidental damage, exposure to radioactive or corrosive materials, negligence,
faulty installation, unauthorised modifications or attempted repair or failure to observe the
requirements and recommendations as given in this User Manual. Additionally
rechargeable batteries (where supplied) are not covered under warranty.

Repairs carried out under the warranty does not extend the warranty period. Components
removed during the warranty repairs become the company property.

The statutory right of the purchaser is not affected by this warranty. The terms of this
warranty is governed by the UK law. For complete details on Warranty Information, see
the terms and conditions of sale available on our web-site.

WEEE 2012/19/EU

© Adam Equipment 2018 76


This balance may not be disposed of in domestic waste. This also applies to countries outside the EU,
per their specific requirements. Disposal of batteries (if fitted) must conform to local laws and
restrictions.
Cet appareil ne peut être éliminé avec les déchets ménagers. L’élimination de la batterie doit être
effectuée conformément aux lois et restrictions locales.
Dieses Gerät nicht mit dem Hausmüll entsorgt.
Dispositivo no puede ser desechado junto con los residuos domésticos
Dispositivo non può essere smaltito nei rifiuti domestici.

FCC / IC CLASS A DIGITAL BALANCE EMC VERIFICATION STATEMENT


NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
balance, pursuant to Part 15 of the FCC rules and Canadian ICES-003/NMB-003 regulation. These
limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference at his
own expense.

Adam Equipment products have been tested with, and are always supplied with
mains power adaptors which meet all legal requirements for the intended country
or region of operation, including electrical safety, interference and energy
efficiency. As we often update adaptor products to meet changing legislation it is
not possible to refer to the exact model in this manual. Please contact us if you
need specifications or safety information for your particular item. Do not attempt to
connect or use an adaptor not supplied by us.

© Adam Equipment 2018 77


ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 40 years’ experience in the
production and sale of electronic weighing equipment.

Adam products are predominantly designed for the Laboratory, Educational, Health and Fitness, Retail and Industrial
Segments. The product range can be described as follows:

-Analytical and Precision Laboratory Balances


-Compact and Portable Balances
-High Capacity Balances
-Moisture analysers / balances
-Mechanical Scales
-Counting Scales
-Digital Weighing/Check-weighing Scales
-High performance Platform Scales
-Crane scales
-Mechanical and Digital Electronic Health and Fitness Scales
-Retail Scales for Price computing

For a complete listing of all Adam products visit our website at www.adamequipment.com

Adam Equipment Co. Ltd. Adam Equipment Inc. AE Adam GmbH.


Maidstone Road, Kingston 1, Fox Hollow Rd. Instenkamp 4
Milton Keynes Oxford, CT D-24242 Felde
MK10 0BD 06478
UK Germany
Phone:+44 (0)1908 274545 USA Phone +49 (0)4340 40300 0
Fax: +44 (0)1908 641339 Phone: +1 203 790 4774 Fax: +49 (0)4340 40300 20
e-mail: Fax: +1 203 792 3406 e-mail:
e-mail:
sales@adamequipment.co.uk sales@adamequipment.com vertrieb@aeadam.de

Adam Equipment S.A. (Pty) Ltd. Adam Equipment (S.E. ASIA) PTY Ltd Adam Equipment (Wuhan) Co. Ltd.
7 Megawatt Road, 70 Miguel Road A Building East Jianhua
Spartan EXT 22 Bibra Lake Private Industrial Park
Kempton Park, Perth Zhuanyang Avenue
Johannesburg, 6163 Wuhan Economic & Technological
Republic of South Africa Western Australia Development Zone
430056 Wuhan
P.R.China
Phone +27 (0)11 974 9745 Phone: +61 (0) 8 6461 6236
Fax: +27 (0)11 392 2587 Fax +61 (0) 8 9456 4462 Phone: + 86 (27) 59420391
e-mail: e-mail: Fax + 86 (27) 59420388
e-mail:

sales@adamequipment.co.za sales@adamequipment.com.au info@adamequipment.com.cn

© Copyright by Adam Equipment Co. All rights reserved. No part of this publication may be reprinted or translated
in any form or by any means without the prior permission of Adam Equipment.

Adam Equipment reserves the right to make changes to the technology, features, specifications and design
of the equipment without notice.

All information contained within this publication is to the best of our knowledge timely, complete and accurate
when issued. However, we are not responsible for misinterpretations which may result from the reading of this
material.

The latest version of this publication can be found on our Website.

www.adamequipment.com

© Adam Equipment 2018 78

You might also like