New 271-8590 Analyzer GP (24-Volt) Quickly Identifies Starting and Charging System Problems (0709, 1406)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

988F Series II Wheel Loader 3408E Engine 2ZR00001-UP (MACHINE)(SEBP2413 - 10...

Page 1 of 3

Shutdown SIS

Previous Screen

Product:  WHEEL LOADER 
Model:  988F II WHEEL LOADER 2ZR 
Configuration: 988F Series II Wheel Loader 3408E Engine 2ZR00001-UP (MACHINE) 

Service Magazine
2006/10/02
Media Number -SEBD9415-00 Publication Date -02/10/2006 Date Updated -02/10/2006

i02586442

New 271-8590 Analyzer Gp (24-Volt) Quickly Identifies


Starting and Charging System Problems {0709, 1406}
SMCS - 0709; 1406

Caterpillar Products:
All

Illustration 1 g01294971

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe... 2023-03-09
988F Series II Wheel Loader 3408E Engine 2ZR00001-UP (MACHINE)(SEBP2413 - 10... Page 2 of 3

Illustration 2 g01294973

The 271-8590 Analyzer Group (24-Volt) performs battery tests, electrical system tests, and diode tests
on 12- and 24-Volt electrical systems for any Caterpillar Products.

The rugged diagnostic tool tests both flooded lead acid (FLA) and absorbed glass mat (AGM) battery
types. Through an algorithm design and internal resistance loading, the tool will test the following
battery pack configurations:

• single battery, 6- or 12-Volt

• two batteries in series, 24-Volt

• two, three, or four batteries in parallel, 12-Volt

• two banks in parallel with each bank in series, 24-Volt

The analyzer features a wide cold cranking ampere (CCA) range of 50 to 4000 CCA at 24 Volts. A
long, 4.6 m (15 ft) test cable assembly allows the technician to work in the cab while the analyzer is
connected to the engine. Amp clamp connections allow the analyzer to use optional amp clamp cables
for current drain tests and for starting and charging tests.

Digital circuitry accurately controls the testing. Minimal interaction from the technician is required.
The analyzer accepts CCA, CA, AHR, MCA, JIS, and DIN units. The large, 4 X 20 character display
requires less scrolling in order to display information. The display is backlit for easy viewing in all
conditions.

The analyzer uses soft-touch keys with an over-molded surround for easy operation while wearing
gloves during cold weather. A security cable connection allows the technician to tether the tool in
order to prevent drops or for security purposes.

The tool has infrared communications capability for use with an optional wireless printer. The printer
features user-defined headers and footers for customized print-outs. A PC interface port allows the
technician to download updates to the analyzer.

The 271-8590 Analyzer Gp (24-Volt) includes the following components: the 24-Volt analyzer, a 4.6
m (15. ft) test cable assembly, side-post terminal adapters, a molded carrying case with a foam insert
and a tool operating manual.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe... 2023-03-09
988F Series II Wheel Loader 3408E Engine 2ZR00001-UP (MACHINE)(SEBP2413 - 10... Page 3 of 3

The available options include the following products: 271-8587 Test Cable As (4.6 m (15 ft)), 225-
8266 Clamp-on Ammeter Gp and 271-8585 Wireless Printer Gp (Infrared).

ReferenceTool Operating Manual, NEHS0973, "24-Volt Analyzer Group".