12.36m

CIRCUIT QUANTITY VOLTS WATTS AMPERES CONDUCTOR SIZE CONDUIT SIZE


2.82m 2.82m 1.9m 2.41m 2.41m LOAD DESCRIPTION I CKT.
C4
NO. RATING RATING RATING
20mm Ø CORRUGATED
C1 LIGHTING OUTLET 9 230 800 2.09 15A 2 - 3.5mm² THW WIRE
C1 FLEXIBLE PIPE
C2
20mm Ø CORRUGATED
C2 LIGHTING OUTLET 8 230 800 3.48 15A 2 - 3.5mm² THW WIRE
A A FLEXIBLE PIPE
20mm Ø CORRUGATED
C3 LIGHTING OUTLET 9 230 800 3.48 15A 2 - 3.5mm² THW WIRE FLEXIBLE PIPE
20mm Ø CORRUGATED
3.56m

3.56m
C4 LIGHTING OUTLET 14 230 800 3.48 15A 2 - 3.5mm² THW WIRE FLEXIBLE PIPE
20mm Ø CORRUGATED
C5 CONVENIENCE OUTLET 10 230 1,800 7.83 20A 2 - 3.5mm² THW WIRE FLEXIBLE PIPE
20mm Ø CORRUGATED
B B C6 AIR CONDITIONING UNIT OUTLET 0 230 1,500 6.52 20A 2 - 3.5mm² THW WIRE FLEXIBLE PIPE
20mm Ø CORRUGATED
C7 AIR CONDITIONING UNIT OUTLET 0 230 1,500 6.52 20A 2 - 3.5mm² THW WIRE FLEXIBLE PIPE

10.83m
10.83m

3.71m

3.71m
20mm Ø CORRUGATED
C8 SPARE 230 1,000 4.35 20A 2 - 3.5mm² THW WIRE FLEXIBLE PIPE

C3
25mm Ø RIGID STEEL
TOTAL 50 230 7,080 30.79 30A 2 - 8 mm² THW WIRE
C C CONDUIT
3.56m

3.56m
D D NOTES & SPECIFICATIONS :
UP

· ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE


PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST
5.64m 1.9m 2.41m 2.41m EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC) 1 & 2, THE RULES AND
REGULATIONS OF THE LOCAL ENFORCING AUTHORITIES AND THE LOCAL
12.36m POWER COMPANY.

· ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE


1 2 3 4 5 6 SUPERVISION OF A DULY LICENSED AND REGISTERED ELECTRICAL
SE PRACTITIONER.
EN RV
TR ICE
AN 2 - 10 mm² THW STRANDED COPPER
E LIGHTING POWER LAY-OUT CE
WIRE INSIDE 25mm Ø RIGID STEEL · THE ELECTRICAL SERVICE POWER SHALL BE SINGLE PHASE, 2-WIRE , 230
1 SCALE 1:100 CONDUIT (RSC) VAC AND 60 HERTZ.
KILOWATT HOUR METER
M CLASS 100 · ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THW"
LEGEND : UNLESS OTHERWISE INDICATED IN THIS PLAN. THE MINIMUM SIZE OF WIRE
LIGHTING OUTLET
FOR POWER AND LIGHTING CIRCUIT HOMERUN SHALL BE 3.5 mm2 AND
PANEL BOARD
INSULATED FOR 600 VOLTS. THE SMALLEST RACEWAY SHALL BE 15 mm Ø
CONVENIENCE OUTLET
TRADE/NOMINAL.
60A

CIRCUIT HOMERUN C2
· ALL OUTLETS SHALL BE GALVANIZED GAUGE NO. 16 "DEEP-TYPE" WITH
C1 15A 15A
FACTORY KNOCK-OUTS.
PANELBOARD
C3 20A 20A C4 · ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED-TYPE
CIRCUIT BREAKER SPARE FOR PARTICULAR LOCATION AND PURPOSE OF USAGE.
C5 20A C6
· GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER
M KILOWATTHOUR METER
CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE (PEC) REQUIREMENTS.
SE
EN RV
TR ICE
AN · MOUNTING HEIGHTS FROM FINISH FLOOR LEVEL SHALL BE AS FOLLOWS:
CE
SERVICE ENTRANCE GROUND
LIGHTING SWITCHES . . . . . . . 1.37 meters above finish floor line
GROUNDING SYSTEM E SINGLE DIAGRAM CONVENIENCE OUTLETS . . . . . . . 0.30 meters above finish floor line
2 SCALE NTS
PANELBOARD . . . . . . . 1.80 meters above finish floor line
ACU OUTLET KILOWATTMETER . . . . . . . 1.80 meters above finish floor line

STRUCTURAL / CIVIL ENGINEER SEAL PROFESSIONAL ELECTRICAL ENGINEER SEAL PROJECT TITLE: REPUBLIC ACT 9266, SEC. 20 ( 4 ) OWNER: DESIGNED BY:
Drawing and specifications duly signed, stamped or sealed, as instrument of
service, are the intellectual properties and documnets of the architect/designer, RYAN REDOBLADO
E-1
MELMAR JANGERALD SABIO PRC No:
PTR No:
TIN No:
DATE ISSUED:

REGISTERED MASTER PLUMBER SEAL


INSTITUTIONAL BUILDING
whether the object for which they are made is executed or not. It shall be
unlawful to any person, without the written consent of the architect or author of
the said documents, to duplicate or to make copies of said documents for use
in the repetition or and for other projects or buildings, whether executed partly
JEFFREY P. RESOLA PREPARED BY:
RYAN REDOBLADO
CHECKED BY:
7
PRC No: 0173302

PTR No:
TIN No: 760931528000
DATE ISSUED:11 / 25 / 2019 PRC No:
PTR No:
TIN No:
DATE ISSUED:
LOCATION: or in whole without their permission. All drawings are to be return when no
longer in use.