FluoroPV Filter Cartridges

® M aterials of Construction
PVDF Membrane · Sterile Liquid Filter Filter Media
LHPVND: Single-Layer Hydrophilic PVDF Membrane
DLHPVNDR: Double-Layer Hydrophilic PVDF Membrane
Support Polypropylene

® Cage/Core/End Caps Polypropylene


FluoroPV Filter Cartridges are composed of a
unique hydrophilic polyvinylidene fluoride (PVDF) mem-
brane characterized by low extractable and protein
Operating Conditions Flow Rate Characteristics
binding. They are suitable for the sterilized filtration of
Max. Operating Pressure 6.9 bar (100 psi) at 25 °C 150

Differential Pressure (kPa)


pharmaceutical liquids including ophthalmic liquids, 4.0 bar (58 psi) at 60 °C
2210
2222
120
biological and other diluted preservative solutions. 2.4 bar (35 psi) at 80 °C
4522
Max. Differential Pressure Forward 6.9 bar (100 psi) at 25 °C 90
Forward 4.0 bar (58 psi) at 60 °C
60
Forward 2.4 bar (35 psi) at 80 °C
Reverse 3.0 bar (44 psi) at 25 °C 30
Forward 1.0 bar (15 psi) at 80 °C
Features and Benefits
0.58m²/ Φ 69-10 inch
0
Low extractable and protein binding Effective Filtration Area 0 10 20 30 40 50 60 70
Water Flow Rate (L/min)10" @20°C,1.005cP
Broad chemical compatibility and temperature resistance

Excellent durability proven by testing forward/reverse pulse up to 100x


Sterilization

Inline Steam Sterilization Up to 100 forward cycles and 50 reverse cycles


Quality Standards (LHPVND & DLHPVNDR) (135 °C for 30 min < 0.3 bar per cycle)

Bacterial quantitative retention of 107 CFU/cm2 Brevundimonas Autoclave up to 400 cycles (130°C for 30min per cycle)
(LHPVND & DLHPVNDR)
Diminuta (ATCC 19146) according to ASTM F838 methodology .
Sterile Filtration

100% Integrity testing in manufacturing .

Each filter is fully traceable with unique serial number . Integrity Test Data
Manufactured in a facility which adheres to ISO 9001:2015 Practices .
Bubble Point BP : ≥ 0.32 MPa(water), LHPVND (0.22 µm)
Full Regulatory Compliance with following :
Bio-burden Reduction

Diffusion Flow DF : ≤ 20 ml/min/10"@ 0.28 MPa, LHPVND (0.22 µm)


· Bacterial Endotoxin: Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined
by Limulus Amebcyte Lysate (LAL),USP<85>.
· Non-fiber Releasing: Component materials meet the criteria for a “ Non-fiber-releasing filter ” as
defined in 21 CFR 210.3(b)(6).
· Component Material Toxicity: Ordering Information
Meet the requirement of USP <87> In Vitro Cytotoxicity Test ;
Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121°C plastics
· TOC/Conductivity at 25 °C:Autoclaved filter effluent meet the USP<643> for Total Organic
LHPVND Removal Ratings End Cap Nominal Length Seal Material -P
Pre-Filtration

Carbon and USP<645> for Water Conductivity per WFI requirements after a UPW flush of [Single-Layer]
0010 = 0.10μm HSF = 226/Fin (PBT Insert) 05 = 5" S = Silicone
specified volume.
· Particle Shedding: Autoclaved filter effluent meet the USP<788>for large volume Injections . 0022 = 0.22μm HSC = 226/Flat (PBT Insert) 10 = 10" E = EPDM
· Indirect Food Additive: All component materials meet the FDA Indirect Food Additive requirements
cited in 21 CFR 177-182.
0045 = 0.45μm HTF = 222/Fin (PBT Insert) 20 = 20" V = Viton
0065 = 0.65μm HTC = 222/Flat (PBT Insert) 30 = 30" P = PFA/Viton
All-Fluorine Filters

0100 = 1.0μm DOE = Double Open End 40 = 40"

Typical Applications DLHPVNDR 2222 = 0.22+0.22μm


[Double-Layer] 2245 = 0.22+0.45μm
Antibiotics Chemicals
Aggressive Solvents Cold and Hot WFI 6545 = 0.65+0.45μm
Capsule Filters

Biological Agents Ophthalmic Solutions 2210 = 0.22+0.1μm


Blood Products Sanitizing Agents 4545 = 0.45+0.45μm
6522 = 0.65+0.22μm
6510 = 0.65+0.1μm
Pharmaceutical Industry
4510 = 0.45+0.1μm Filtration Solutions 17 - 18