Asco 8345 - 4.09R2
Asco 8345 - 4.09R2
Asco 8345 - 4.09R2
4
Pilot Operated
B A
Features
• Compact valves for general service applications.
• Low-cost, 4 way valve when low flow is sufficient.
%
• Mountable in any position.
^
Construction )
Valve Parts in Contact with Fluids
Electrical
Watt Rating and Power
Consumption Spare Coil Part No.
Standard AC
General Explosionproof Explosionproof
Coil and
Purpose (EF) (EV)
Class of DC VA VA Nominal Ambient Temperature Ranges:
Insulation Watts Watts Holding Inrush AC DC AC DC AC DC
AC: 32˚F to 125˚F (0˚C to 52˚C)
F 11.6 10.1 25 50 238610 238710 238614 238714 274614 274714
DC: 32˚F to 104˚F (0˚C to 40˚C)
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). Refer to Engineering Section for details.
6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages are
available when required.
Approvals:
CSA certified. UL listed as General Purpose Valve.
EV8345G81 solenoid only UL approved.
Meets applicable CE directives.
Refer to Engineering Section for details.
4.09 R2
SERIES
8345 4
Specifications (English units)
Orifice Watt Rating/
Size Cv Flow Operating Pressure Differential (psi) Max. Fluid Class of Coil
(ins.) Factor Max. AC Max. DC Temp. ˚F Brass Body 316 Stainless Steel Body Insulation
Pipe Air- Lt. Oil Air- Lt. Oil Constr.
Size Inert @ 50 Inert @ 50 Catalog Catalog Ref.
(ins.) Pressure Exhaust Inlet Exhaust Min. Gas Water SSU Gas Water SSU AC DC Number Number No. AC DC
SINGLE SOLENOID
1/4 1/16 3/32 .09 .09 10 150 150 150 100 100 100 180 104 8345G1 EV8345G81 1 10.1/F 11.6/F
SINGLE SOLENOID AIR-ONLY CONSTRUCTION - Exhaust to Atmosphere
1/4 1/16 3/32 .09 .09 10 150 - - 100 - - 180 104 8345H3 - 2 10.1/F 11.6/F
Constr. Ref. 1, 2
4.10 R2