Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Air and Water Solenoid Valves: Features

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Pilot Operated 3/2

4 Air and Water Solenoid Valves


Brass Body • 3/8" to 1" NPT
SERIES
8316

Features

3-WAY
• Diaphragm poppet valves suitable for controlling % )
air, inert gas, and liquids
• Internal piloting controls large orifices to provide
high flows
• Can be used to pilot large actuators to provide quick
closing of large control valves
• Resilient seating for tight shutoff
• Mountable in any position

Construction
Valve Parts in Contact with Fluids
Body Brass
Seals and Disc NBR
A
Diaphragm Assembly NBR
NC
Core Tube 305 Stainless Steel E P

Core and Plugnut 430F Stainless Steel NO


Core Springs 302 Stainless Steel and 17-7PH Stainless Steel
Shading Coil Copper
Pilot Seat Cartridge
CA
and Disc-Holder

Electrical
Watt Rating and Power
Standard Consumption Spare Coil Part Number
Coil and
General Purpose Explosionproof
Class of DC AC VA VA
Insulation Watts Watts Holding Inrush AC DC AC DC
F 10.6 6.1 16 30 238210 238310 238214 238314
F 22.6 17.1 40 70 238610 238710 238614 238714
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). Nominal Ambient Temp. Ranges
6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages AC: 32˚F to 125˚F (0˚C to 52˚C)
available when required.
DC: 32˚F to 104˚F (0˚C to 40˚C)
Refer to Engineering Section for details.
Approvals
Solenoid Enclosures CSA certified. Meets applicable CE directives.
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X. Refer to Engineering Section for details.
Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9. Important
(To order, add prefix “EF” to catalog number.) A minimum operating pressure differential must be
See Optional Features Section for other available options. maintained between the pressure and exhaust ports.
Supply and exhaust piping must be full area, unrestricted.
ASCO flow controls and other similar components must
be installed in the cylinder lines only.
43
3/2
SERIES
8316 4
Specifications (English units)
3-WAY

Operating Pressure Watt Rating/


Differential (psi) Max. Fluid Brass Body Class of Coil
Max. AC Max. DC Temp. ˚F Insulation y
Pipe Orifice Cv
Size Size Flow Air-Inert Air-Inert Const.
(ins.) (ins.) Factor Min. x Gas Water Gas Water AC DC Catalog Number Ref. AC DC
NORMALLY CLOSED (Closed when de-energized)
3/8 5/8 2.5 10 150 125 125 125 180 120 8316G054 1 6.1/F 10.6/F
3/8 5/8 2.5 10 250 250 250 250 180 120 8316G014 2 17.1/F 22.6/F
1/2 5/8 3.2 10 150 125 125 125 180 120 8316G064 1 6.1/F 10.6/F
1/2 5/8 3.2 10 250 250 250 250 180 120 8316G024 2 17.1/F 22.6/F
3/4 11/16 4.8 10 150 125 125 125 180 120 8316G074 3 6.1/F 10.6/F
3/4 11/16 4.8 10 250 250 250 250 180 120 8316G044 4 17.1/F 22.6/F
1 1 12.5 10 150 125 125 125 180 120 8316G034 5 6.1/F 10.6/F
NORMALLY OPEN (Open when de-energized)
3/8 5/8 2.5 10 150 125 125 125 180 120 8316G056 1 6.1/F 10.6/F
3/8 5/8 2.5 10 250 250 250 250 180 120 8316G016 2 17.1/F 22.6/F
1/2 5/8 3.2 10 150 125 125 125 180 120 8316G066 1 6.1/F 10.6/F
1/2 5/8 3.2 10 250 250 250 250 180 120 8316G026 2 17.1/F 22.6/F
3/4 11/16 4.8 10 150 125 125 125 180 120 8316G076 3 6.1/F 10.6/F
3/4 11/16 4.8 10 250 250 250 250 180 120 8316G046 4 17.1/F 22.6/F
1 1 12.5 10 150 125 125 125 180 120 8316G036 5 6.1/F 10.6/F
x 10 psi Minimum Operating Pressure Differential required. Valve vents to "zero" psi.
y On 50 hertz service, the watt rating for 6.1/F solenoid is 8.1 watts.

Specifications (Metric units)


Operating Pressure Watt Rating/
Differential (bar) Max. Fluid Brass Body Class of Coil
Max. AC Max. DC Temp. ˚C Insulation y
Pipe Orifice Kv Flow
Size Size Factor Air-Inert Air-Inert Const.
(ins.) (mm) (m3/h) Min. x Gas Water Gas Water AC DC Catalog Number Ref. AC DC
NORMALLY CLOSED (Closed when de-energized)
3/8 16 2.14 0.7 10 9 9 9 82 49 8316G054 1 6.1/F 10.6/F
3/8 16 2.14 0.7 17 17 17 17 82 49 8316G014 2 17.1/F 22.6/F
1/2 16 2.74 0.7 10 9 9 9 82 49 8316G064 1 6.1/F 10.6/F
1/2 16 2.74 0.7 17 17 17 17 82 49 8316G024 2 17.1/F 22.6/F
3/4 17 4.11 0.7 10 9 9 9 82 49 8316G074 3 6.1/F 10.6/F
3/4 17 4.11 0.7 17 17 17 17 82 49 8316G044 4 17.1/F 22.6/F
1 25 10.17 0.7 10 9 9 9 82 49 8316G034 5 6.1/F 10.6/F
NORMALLY OPEN (Open when de-energized)
3/8 16 2.14 0.7 10 9 9 9 82 49 8316G056 1 6.1/F 10.6/F
3/8 16 2.14 0.7 17 17 17 17 82 49 8316G016 2 17.1/F 22.6/F
1/2 16 2.74 0.7 10 9 9 9 82 49 8316G066 1 6.1/F 10.6/F
1/2 16 2.74 0.7 17 17 17 17 82 49 8316G026 2 17.1/F 22.6/F
3/4 17 4.11 0.7 10 9 9 9 82 49 8316G076 3 6.1/F 10.6/F
3/4 17 4.11 0.7 17 17 17 17 82 49 8316G046 4 17.1/F 22.6/F
1 25 10.71 0.7 10 9 9 9 82 49 8316G036 5 6.1/F 10.6/F
x 1 bar Minimum Operating Pressure Differential required. Valve vents to "zero" bar.
y On 50 hertz service, the watt rating for 6.1/F solenoid is 8.1 watts.

44
3/2
4 SERIES
8316

Dimensions: inches (mm)

3-WAY
Const.
Ref. H K L P
ins. 5.08 3.08 2.76 3.94
1 Const. Ref. 1,2
mm 129 78 70 100
ins. 5.26 3.15 2.76 4.12
2
mm 134 80 70 105

45
3/2
SERIES
8316 4
Dimensions: inches (mm)
3-WAY

Const.
Ref. A B C H K L M N P R W
ins. 1.61 1.41 1.66 6.01 3.46 3.38 2.16 .53 4.32 .50 3.31
3
mm 41 36 42 153 88 86 55 13 110 13 84
ins. 1.61 1.41 1.66 6.19 3.53 3.38 2.16 .53 4.50 .50 3.31
4
mm 41 36 42 157 90 86 55 13 114 13 84
ins. X 1.80 X 6.63 3.71 4.44 2.81 .88 4.57 1.74 5.32
5
mm X 46 X 168 94 113 71 22 116 44 135

Const. Ref. 3, 4, 5

FLOW DIAGRAMS

Normally Closed Normally Open


De-Energized Energized De-Energized Energized

46