8040 NC Pilot
8040 NC Pilot
8040 NC Pilot
Features
• 2-way normally closed operation ^ #
• For gas pilot control of commercial and industrial
gas burners
• Direct lift with resilient soft seating for tight shut-off
• Valves provided with 1/8" NPT downstream pipe tap
with plug for routine testing
• Mountable in any position
Construction
Valve Parts in Contact with Fluids
Body Aluminum
Seals and Disc NBR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel NC
Springs 17-7 PH
Shading Coil Copper
Pipe Plug Zinc Plated Steel
Electrical
Watt Rating and
Power Consumption Spare Coil Family
Standard
Coil and AC General Purpose Explosionproof
Class of VA VA Ambient
Insulation Watts Holding Inrush Temp.°F AC AC
F 6.1 16 40 -40 to 125 238210 238214
Standard Voltages: 24, 120, 240 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).
COMBUSTION
287
2/2
SERIES
8040 4
Specifications (English units)
Approx.
Gas Operating Pressure
Pipe Orifice Cv Max. Shipping
Capacity Differential (psi) Agency
Size Size Flow Fluid Const. Weight
(ins.) (ins.) Factor Btu/hr. Min. Max. Temp.°F Catalog Number Ref. UL FM CSA Wattage (lbs)
COMBUSTION (Fuel Gas)- NORMALLY CLOSED
1/8 5/16 1 53,700 0 15 125 8040H006 1 6.1 1.8
1/4 5/16 1.1 59,000 0 15 125 8040H007 1 6.1 1.8
3/8 5/16 1.2 64,400 0 15 125 8040H008 1 6.1 1.8
= Safety Shutoff Valve; 1" W.C. Drop @ 2" W.C. Inlet Pressure, 1,000 Btu/cu.ft. or more, 0.64 Specific Gravity Gas.
On 50 Hz service watt rating is 8.1; EF option approved to UL and CSA only.
Capabilities Chart
Solenoid Options Base Catalog Number Resilient Materials Standard Rebuild Kit
NEMA Type 3-9 High Temp. Junction Box Wiring Box Screw Terminal Aluminum NBR AC
EF HT - JKF 8040H006 318247
EF HT JB JKF 8040H007 318247
EF HT JB JKF 8040H008 318247
= Standard. Other options may be available. All option combinations may not be available.
COMBUSTION
288
2/2
4 SERIES
8040
Const. Ref. 1
2.92 (74)
2.30
(58)
2.74
1.44
(70) 1/2 NPT
(37)
PIPE PLUG
1 PLACE
NPT
BOTH ENDS
COMBUSTION
289
290
COMBUSTION