TM11583 - XCG210LC-8B Excavator Operation and Test


Pump Control Pilot Pressure Signal Test

Pump Control Pilot Pressure Signal Test

-: Specifications

SPECIFICATIONS
Hydraulic Oil Temperature 45—55° C
110—130° F
Engine Speed (approximate) 1800 rpm
Power Mode Switch Position S (standard)
Auto Idle Switch Position Off
Pump 1 or Pump 2 Control Pressure in Neutral State Pressure (approximate) 2.8 MPa
2 800 kPa
28.0 bar
406 psi
Pump 1 or Pump 2 Control Pressure in Full Stroke Pressure .55 MPa
551.6 kPa
5.5 bar
80 psi

-: Service Equipment and Tools

SERVICE EQUIPMENT AND TOOLS


JT02156A Digital Pressure and Temperature Analyzer
JT02162 Transducer 35 000 kPa (350 bar) (5000 psi)
Gauge 7000 kPa (70 bar) (1000 psi)

The function of the pump 1 and pump 2 regulators is to change pump flow in response to the actuation of pilot control valves
to shift the control valve spools.

The purpose of this test is to check that the regulated pump control pilot pressure signal from the flow rate pilot valves to the
remote control spool in pump 1 and pump 2 regulators decreases as a function is actuated and increases when function is
returned to neutral.

1. Release hydraulic oil tank pressure. See Hydraulic Oil Tank Pressure Release Procedure . (Group 9025-25.)

2.
TX1071663A-UN: Pump Control Pilot Pressure Signal Test

LEGEND:

1 - Transducer
2 - Pilot Pressure Hose
3 - Adapter Tee Fitting
4 - Pump Pressure Regulator

Disconnect pilot pressure hose (2) and install adapter tee fitting (3) for testing.

file:///C:/ProgramData/Service%20ADVISOR/Temp/TM11583_09001faa811419c8.ht... 19/04/2020
Page 2 of 2

3. Install JT02156A Digital Pressure/Temperature Analyzer and JT02162 Transducer or 7 000 kPa (70 bar) (1000 psi)
gauge to tee fitting. See JT02156A Digital Pressure/Temperature Analyzer Installation . (Group 9025-25.)

4. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure . (Group 9025-25.)

Item Measurement Specification

Hydraulic Oil Temperature 45—55° C


110—130° F

5. Run machine at specifications.

Item Measurement Specification

Engine Speed (approximate) 1800 rpm

Power Mode Switch Position S (standard)

Auto Idle Switch Position Off

6. Return all controls to neutral and record pump control pressure.

Item Measurement Specification

Pump 1 or Pump 2 Control Pressure Pressure (approximate) 2.8 MPa


in Neutral State 2 800 kPa
28.0 bar
406 psi

7.

CAUTION:

Prevent possible injury from machine movement. Ensure that area is clear of bystanders and
large enough to operate all machine functions.

Actuate boom up control lever to full stroke. Pressure reading should decrease as lever moves. Operate function to full
stroke and record pump control pressure.

Item Measurement Specification

Pump 1 or Pump 2 Control Pressure Pressure .55 MPa


in Full Stroke 551.6 kPa
5.5 bar
80 psi

TP97644,000013C-19-20100311