TM1914 - C Series II Motor Graders Operation and Test


Transmission Pump Flow Test

Transmission Pump Flow Test

-: Specifications

SPECIFICATIONS
Oil Temperature 43 ± 6°C (110 ± 10°F)
Transmission Pressure 1862 ± 103 kPa (18.6 ± 1.0 bar) (270 ± 15 psi)
Engine Speed 2000 ± 5 rpm
Pump Typical New Flow 98 L/min (26 gpm)
Pump Minimum Allowable Flow 76 L/min (20 gpm)

-: Essential Tools

ESSENTIAL TOOLS
38H1194 (1 5/16 ORB x -12 M ORFS) Adapter (2 used)

-: Service Equipment And Tools

SERVICE EQUIPMENT AND TOOLS


JT05800 Digital Thermometer
JT05801 Electronic Tachometer
Flow Meter

1. Connect thermometer. See Digital Thermometer Installation . (See procedure in this group.)

2. NOTE:

Monitor tachometer in the machine can be used. See Calibration procedure in Group 9015-20.

See JT05801 Clamp-On Electronic Tachometer Installation. (Go to 9010.)

3. Install flow meter between transmission and transmission oil filter.

4. IMPORTANT:

Flow meter loading valve must be open before starting the engine and during the test to prevent damage
to the transmission pump.

Open flow meter loading valve.

5. Check and correct transmission oil level. See Check Transmission Oil Level

(Go to Operators Manual group 60.)

6. Heat transmission oil to test specifications. (See Transmission and Axle Oil Warm-Up Procedure in this group.) Access
Transmission Pump Flow Test SERVICE ADVISOR™ system template for readings.

Item Measurement Specification

Oil Temperature 43 ± 6°C (110 ± 10°F)

file:///C:/ProgramData/Service%20ADVISOR/Temp/TM1914_09001faa8027c588.html 17/08/2024
Page 2 of 2

7. Place transmission control and park brake lever in park “P” position.

8. Check transmission pressure. If pressure is not within specification, adjust pressure. (See Transmission System
Pressure Test in this group).

Item Measurement Specification

Transmission Pressure 1862 ± 103 kPa (18.6 ± 1.0 bar)


(270 ± 15 psi)

9. Run engine at specified speed and record flow.

Item Measurement Specification

Engine Speed 2000 ± 5 rpm

If flow is not within specifications, replace transmission filter, check pump suction tube and end fittings for air leaks,
remove and clean transmission suction screen and test flow again.

Item Measurement Specification

Pump Typical New Flow 98 L/min (26 gpm)

Pump Minimum Allowable Flow 76 L/min (20 gpm)

If still low replace pump.