986AAS
986AAS
986AAS
(UK)
ISO 9001
• Flame Only
• Graphite Furnace
• Combined Flame and Graphite Furnace with the option for up to nine
heating ramps.
The system is fully controlled from a PC with AAWin Software. The main
features of the system are:
3- The control of the gas flows for the fuel gas (C2H2) and the Positioning
of the burner is also carried out directly from the software thus allowing
optimisation of the instruments for the best analytical parameters for a
selected analysis.
7- The ignition of the flame is computer controlled and the various safety interlocks
offer a very safe operating system.
The hollow cathode lamp control panel from the AAWin software is shown below:
ADVANCED GRAPHITE FURNACE:
▪ The unique design of the graphite furnace reduces the chemical interference
effects and memory effects by uniformly heating the graphite electrode.
▪ The computer controlled heating program allows the user to select the best heating
program for the analysis.
▪ The optical temperature during the atomisation stage ensures the rapid heating
and rapid analysis. This helps to extend the life of the graphite tube and enhances
analytical accuracy.
SPECIFICATIONS:
Optic System:
Wavelength Range: 190nm - 900nm
Monochromator: Czerny-Turner configuration
Spectral Bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (5 steps. with
automatic changeover)
Wavelength Accuracy: 0.25nm
Wavelength Repeatability: 0.15nm
Baseline Stability: 0.005A/30 min
Flame analysis:
Sensitivity (Cu): 0.03 µg/ml/1%
Burner Head: Titanium alloy burner
Nebulizer: High-efficiency glass nebulizer
Atomization Chamber: Corrosion-resistant material
Position Adjustment: Automatic changeover of flame and furnace
Automatic setting of optimum height for flame burner
Safety: Automatic ignition and of mixing air-acetylene gas with
safety control
Background correction:
Deuterium Lamp Background Correction: Abs
Self-Reversal Background Correction: 3.0 Abs
Data processing:
Analytical method: flame, graphite furnace and hydride
Determination method: calibration curves using 1st , 2nd and 3rd order of fit,
standard addition method
Repetitions: 1-20 with calculations of average , SD and RSD
Result Printout: output of parameters, data, spectra and calibration
curves
Mainframe:
Light Source: 8 hollow cathode lamp turrets with 2 lamps
simultaneously lit ( one lamp pre-heated )
Power Supply: 110V/60Hz or 220V/50Hz three-phase AC
200W (mainframe) 5000W (graphite furnace)
Dimensions: mainframe 110 cm x 50cm x 45cm
graphite furnace 50cm x 50cm x 45cm