Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

986AAS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Biotech Engineering Management Co. Ltd.

(UK)
ISO 9001

The Phoenix-986 Atomic Absorption Spectrophotometer is available in the following


configuration:

• Flame Only
• Graphite Furnace
• Combined Flame and Graphite Furnace with the option for up to nine
heating ramps.
The system is fully controlled from a PC with AAWin Software. The main
features of the system are:

1- The flame and graphite furnace is integrated into one instrument.


The change over from one technique to another is carried out by simple
keystrokes within the software.

2- The instruments have a motorised 8 hollow cathode lamp turret


which allows the automatic positioning and optimisation of each
hollow cathode lamp by the software.

3- The control of the gas flows for the fuel gas (C2H2) and the Positioning
of the burner is also carried out directly from the software thus allowing
optimisation of the instruments for the best analytical parameters for a
selected analysis.

4- Two methods of background correction are available. The first utilises


a deuterium lamp and the second is the proven method of self reversal.

5- The location of the wavelength and peak selection is automatic and


controlled from the software.

6- The spectral bandwidth is automated and is available with a choice


of five slit sizes.

7- The ignition of the flame is computer controlled and the various safety interlocks
offer a very safe operating system.

The hollow cathode lamp control panel from the AAWin software is shown below:
ADVANCED GRAPHITE FURNACE:

▪ The unique design of the graphite furnace reduces the chemical interference
effects and memory effects by uniformly heating the graphite electrode.
▪ The computer controlled heating program allows the user to select the best heating
program for the analysis.
▪ The optical temperature during the atomisation stage ensures the rapid heating
and rapid analysis. This helps to extend the life of the graphite tube and enhances
analytical accuracy.

PROVEN SAFETY FEATURES:


▪ The flame conditions are continuously monitored and should the flow rates change
an audible alarm sounds.
▪ The pressure of the support gas (oxidant) is monitored constantly. If the pressure
changes then the flow of the fuel gas will be stopped and the flame will be safely
extinguished.
▪ A sensor monitors the level of liquid in the drain and will prevent ignition if too
low. The flame will also be extinguished of the level of liquid in the drain changes
significantly.
▪ The argon pressure for the graphite furnace is constantly monitored and should it
change the heating cycle for the graphite electrode will immediately cease and the
graphite electrode will be de-energised.
▪ Cooling water flow rates for the graphite furnace are also monitored for changes
and should changes occur the heating program will cease.
▪ If the graphite tube should facture during the heating program the heating will
cease.
Elements that can be analysed with the Phoenix-986:

INNOVATIVE DESIGN OF THE PHOENIX-986:

▪ The user friendly software requires a Windows


platform and operates within Win95, Win98, Win NT,
Win 2000 and WinXP. The system uses a number
of software wizards to guide the operator through
setting up procedures.

▪ The software controls the automatic switch over for


the Hollow Cathode Lamps and automatically
optimises working parameters for the system.
The software also allows manual input of data
to ensure that the operator always stays in control.
The software will automatically complete the
configuration of the system for analysis.

▪ The user has the choice of two methods of background


correction namely the self reversal system OR the
traditional deuterium lamp background correction
system.

▪ During the analysis cycle of both the flame and


graphite furnace the software shows the entire
measurement process. This includes measured
values, temperature steps, time etc. all signal and
temperature data is stored for future re-call and printout.
▪ Detailed reporting and QC control software is included
within AAWin allows printout of spectra, standard
calibration curves, analysis and signal data. Full printout
of operating parameters is also available for user
references.

▪ The following methods of analysis can be carried out


using the Phoenix-986 system Absorption, emission,
graphite furnace analysis, hydride and cold vapour
analysis.

SPECIFICATIONS:

Optic System:
Wavelength Range: 190nm - 900nm
Monochromator: Czerny-Turner configuration
Spectral Bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (5 steps. with
automatic changeover)
Wavelength Accuracy: 0.25nm
Wavelength Repeatability: 0.15nm
Baseline Stability: 0.005A/30 min

Flame analysis:
Sensitivity (Cu): 0.03 µg/ml/1%
Burner Head: Titanium alloy burner
Nebulizer: High-efficiency glass nebulizer
Atomization Chamber: Corrosion-resistant material
Position Adjustment: Automatic changeover of flame and furnace
Automatic setting of optimum height for flame burner
Safety: Automatic ignition and of mixing air-acetylene gas with
safety control

Graphite furnace analysis:


Character Value (Cd): 0.5Pg
Temperature Range: Ambient - 2650
Heating: Voltage feedback control when drying and ashing;
Optical temperature control when atomizing
Heating program: Up to 9 steps with choices of ramp, temperature
increase and full-power heating

Background correction:
Deuterium Lamp Background Correction: Abs
Self-Reversal Background Correction: 3.0 Abs
Data processing:
Analytical method: flame, graphite furnace and hydride
Determination method: calibration curves using 1st , 2nd and 3rd order of fit,
standard addition method
Repetitions: 1-20 with calculations of average , SD and RSD
Result Printout: output of parameters, data, spectra and calibration
curves

Mainframe:
Light Source: 8 hollow cathode lamp turrets with 2 lamps
simultaneously lit ( one lamp pre-heated )
Power Supply: 110V/60Hz or 220V/50Hz three-phase AC
200W (mainframe) 5000W (graphite furnace)
Dimensions: mainframe 110 cm x 50cm x 45cm
graphite furnace 50cm x 50cm x 45cm

Note: Typical response: 2 g/ml Cu gives about 0.38Abs.

ACCESSORIES:

HYDRIDE AND COLD VAPOUR ANALYSIS:


A hydride generator is available for the determination of elements such as Arsenic,
Selenium, Antimony, Tellurium and mercury at ultra low levels. The hydride
generator is supplied with an absorption cell, and electrical absorption cell heater
and controller and all necessary burner fittings.

You might also like